Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date8 Aug 2019
Closing Date19 Aug 2019
Tender Amount₹ 54,42,000
Costs
EMD
₹ 1,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_PDD_78576_2Bid Award Id
ViewTender No
STD-II/Rangoor-07Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
11 KV 630 mm² Single Core XLPE Power Cable (with one spare length) armoured FRLS alongwith repair / renovation / extemnsion of XLPE cable trench and allied civil works.
240
-
-
11 KV 3-Core XLPE 300 mm² armoured FRLS
60
-
-
11 KV 3- Core XLPE 185 mm² armoured FRLS(spare)
60
-
-
11 KV heat shrinkable Cable Termination Kit for incoming Cable
-
-
-
11 kV Cable Kits ‐ indoor for 630 mm2 single core incoming cable
4
-
-
11 kV Cable Kits ‐ outdoor for 630 mm2 single core incoming cable
4
-
-
11 KV heat shrinkable Cable Termination Kit for outgoing Cable
-
-
-
11 kV Cable Kits ‐ indoor for 300/185 mm2 single core outgoing cable
2
-
-
11 kV Cable Kits ‐ outdoor for 300/185 mm2 single core outgoing cable
2
-
-
11 kV Isolator, Double Break , 3-Pole,600 Amps,Horizontal Mounting Type with Earth Switch.
4
-
-
Galvanized Iron of sorts
100
-
-
Earthing of equipments Complete by GI Pipe 40 mm ,2.5 mtr long by GI Strip(25mm x4mm).
22
-
-
a) Supply, Erection, Testing and Commissioning of Battery Bank 30 V,100 AH of 15 No. cells of 2 V each, sealed maintance free VRLA type, High Polyprophelene copolymer container, flame retardant. b) 30V ,100 AH,Float cum Boost Charger with full wave rectifier for 220 V, 1Phase 50 HZ AC Input Supply including dismantling, dismantled material write back to divisional store (Complete Job).
1
-
-
Supply, Erection, Testing and Commissioning of Distribution Panel (30 V,DC ) made of CRCA thickness not less than 2mm.Powder Coated, degree of protection IP43 for 2 No. Battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double bus-bar of adequate size ,12 no. DP DC MCB (0-32 A) including indication lamps and cable and other accessories.including dismantling, dismantled material write back to divisional store (Complete Job).
1
-
-
Supply, Erection, Testing and Commissioning of Distribution Panel (415,AC ) made of CRCA thickness not less than 2mm.Powder Coated, degree of protection IP43.200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps) and 5 No DP MCBs (0-32 A),rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories including dismantling, dismantled material write back to divisional store (Complete Job).
1
-
-
Rubber Mat 1m x 2m 19 mm thick
2
-
-
Fire Extinguisher Co2 Type of 4.5 Kg capacity for control room
2
-
-
Rubber Gloves for 33 KV Level
2
-
-
Rubber Gloves for 11 KV Level
2
-
-
Earthing Rod (set of three rods)
2
-
-
High Voltage detector all voltages
1
-
-
Supply, Erection, Testing and Commissioning of 33 kV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) reputed make preferably CG, Scheneider, Seimens, Megawin, ABB or any other reputed equivalent make.
1
-
-
Supply, Erection, Testing and Commissioning of 33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA)
2
-
-
Supply, Erection, Testing and Commissioning of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
3
-
-
Supply, Erection, Testing and Commissioning of 30 kV Lightening Arrestors (30 kV, 10KA, Station class, ZnO, Polymer) gap less along with Civil works
2
-
-
Supply, Erection, Testing and Commissioning of 33 kV C&R Panel along with O/C,E/F and diffrential relays(IEC61850), mimic diagram,voltmeter,Ammeter,Annuniciation reputed make preferably CG, GEC, Stelmac, Electricfeld, Power Control, L&T, ABB or any other reputed equivalent make.
1
-
-
33 kV Post Insulator Polymer (36KV, 235kv Impulse,Creepage distance 1224m)
3
-
-
Galvanised Steel Structures
1.04
-
-
Galvanised Nuts & Bolts of sorts
0.15
-
-
12 Core 2.5 mm2 Control cable copper Armoured , 1.1 KV Grade, ISI, FRLS.
80
-
-
6 Core 2.5 mm2 Control cable copper Armoured , 1.1 KV Grade, ISI, FRLS.
300
-
-
2 Core 2.5 mm2 Control cable copper Armoured , 1.1 KV Grade, ISI, FRLS.
250
-
-
Lugs, Ferrules etc.
20
-
-
ACSR Conductor Panther
100
-
-
T Clamps
3
-
-
Evaluation Notes How It Works ?