Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Eprocure
Opening Date21 Jun 2018
Closing Date2 Jul 2018
Tender Amount₹ 1
Costs
EMD
₹ 25,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_PDD_56415_1Bid Award Id
ViewTender No
TLMD-IV/e-NIT/1 of 2018-19Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Reparing of cooloing fans of transformers including replacement of damaged winding, bearing etc.
1
-
-
... More
Lifting of top lid of power transformer for complete physical inspection & replacement of gaskets.
1
-
-
... More
Replacement of damaged core bolts/Earthning strip etc.
1
-
-
... More
Overhualling of Circuit Breaker :- Checking of oil pressure drop during duty cycle operation check, Checking of auto-starting / stopping of oil pump,pressure switch setting,etc, Checking of healthiness of accumulator by checking the pre-charging pressure when building up pressure from zero, Checking of operation of safety valve, Cleaning of breaker units, checking of protection equipmentsand replacement of defective ones, i.e., complete inspection and testing of SF6 type circuit breakers inclusive of operating mechanism. Maintaning gas levels, venting of circuit breakers, replacement of o-rings , gas kits including circuit breaker anylises by CBA etc.
-
-
-
... More
220KV SF6 Breaker
1
-
-
... More
132KV SF6 Breaker
1
-
-
... More
33KV VCB
1
-
-
... More
Current Transformers :- Checking of bellow expansion, Checking of oil leakage in terminal box, Checking of primary connection strips, Checking of healthiness of gaskets,Checking the tightness of all connections including earthing of PF terminal, Cleaning of marshalling box and junction box, Checking cleanliness / tightness of all electrical connections including earthing of all marshalling boxes, CT secondary terminal, space heater and illumination, healthiness of secondary terminal bushing, checking of oil level, measurement of IR value tightening of jumpers, CT anylises with the help of CTA etc.
-
-
-
... More
220KV CT
1
-
-
... More
132KV CT
1
-
-
... More
33KV CT
1
-
-
... More
CVT's / PT's :- Visual checking of earthing HF point (in case it is not being used for PLCC,Checking of any breakage or cracks in cementing joint, Cleaning of CVT capacitor stacks and tightness of terminal connections, Checking of space heater and illumination,Checking and tightness of all connections including earth connections Cleaning of marshalling box and junction box, Checking of healthiness of gaskets, Checking of neutral earthing in CVT, healthiness of all gaskets and oil level. Measurement of IR value and tightening of all connections and droppers.
-
-
-
... More
220KV
1
-
-
... More
132KV
1
-
-
... More
33KV
1
-
-
... More
Surge Arrestors :- Checking of leakage current(third harmonic resistive current), Testing of counters and leakage current meters, Cleaning of insulators, Checking of earth connections between surge arrester,surge monitor and earth, Checking of leakage current after cleaning of porcelain surface, cleaning of LA insulators. Measurement of IR value and tightening of droppers and testing of counter and leakage of current meters, Cleaning of insulators, Checking of earth cennections between surge arrester, Surge moniter and Earth.
-
-
-
... More
220kV
1
-
-
... More
132kV
1
-
-
... More
33kV
1
-
-
... More
Isolators :- Maintenance of linkages including transmission gears, stopper bolts. Cleaning of auxiliary switch contacts and greasing with silca grease, cleaning of support insulators, termination contacts, checking of elecctrical / mechanical interlocks with E/S and CB, mounting bolts, alignment, nuts, pins, space heater, illumination, healthiness of gaskets, auxiliary contacts, alignment of earthing blades, operation of earth switch, almunium / copper flexible conductor, earth connections of structures and MB. lubrication of operating mechanism, hinges lock joints, levers, bearings, main contacts, cleaning of post insulators, tightening of clamps.
-
-
-
... More
220kV
1
-
-
... More
132kV
1
-
-
... More
33kV
1
-
-
... More
Reparing of Three phase motors of isolators including replacement of damaged winding and bearing.
1
-
-
... More
:Replacment of damage 220kV/132kV CT/PT/LA including dismentiling.
1
-
-
... More
DROPERS/JUMPERS/Clamps :- Replacement of damaged / burnt droppers or jumpers or Clamps of isolators/ breakers/transformers /CT/PT etc.
220/132/33kV Yard
1
-
-
... More
Post Insulators :- Checking of insulators for cracks and cleaning of insulators.
-
-
-
... More
220kV
1
-
-
... More
132kV
1
-
-
... More
33kV
1
-
-
... More
Gantry Columns and Beams :- Tightening of all nuts / bolts and providing of missing nuts / bolts and damaged members
-
-
-
... More
220kV
1
-
-
... More
132kV
1
-
-
... More
33kV
1
-
-
... More
Illumination System :- Checking of healthiness of fittings in station buildings, outdoor switch yard, repairing and replacement if required, lighting of panels. Tightening of terminals etc.
1
-
-
... More
Battery Bank: Checking and cleaning of battery cell terminals, application of patrolum gelly, if required, conduction of battery impendence test and discharge test checking voltage temperature, current, sp. Gravity of individual cells as well as terminals voltage, battery dischrge testing etc.
1
-
-
... More
Battery Charger :- Checking of control cards, measurement of test point voltage values, testing of DC earthfault and U/V relays, IR measurement of charger transformer, checking of earthing etc. Checking of charger panel / DCDB for electrical connections, cleanliness etc.
1
-
-
... More
Protection System :- Checking of relays and application of CCl4 for cleaning, replacement of worn out / defunct relays, checking and replacement of control wiring, if required, primery & secondery injection testing etc.
1
-
-
... More
Cleaning of cable trenches including of dressing of cables, trays, racks etc
1
-
-
... More
L.T. Transformer :- Testing of oil BDV, IR measurement, Testing /checking of OTI,WTI and Buchholz (if provided, Checking of healthiness of Pressure relief diaphragm, Checking healthiness of Buchholz relay, Checking tightness of earthing connections
L.T Pannel:
Cleaning of panels,bus bar insulators etc. Relays Testing, Tightning of all electrical connections,Checking of indicating meters ,Check for change-over facility, if provided,Check operation /indications in OFF Load condition of MCCB,
1
-
-
... More
Earthing Mat :- Measurment of earth resistivity, checking of electrical continuity of equipment earthings, tightening of earthing connectors, removal of rust from bolted earth connectors and tightening.
220/132kV
1
-
-
... More
DC Distribution Board :- Checking of connections, wiring, replacement of wiring if needed and checking of healthiness of all D/C lights.
1
-
-
... More
Fire Protection System:- Refilling of fire fighting CO2 and dry chemical powder gas cylinders, providing of Nosels etc.
1
-
-
... More
Deweeding of switch yard
1
-
-
... More
General inspection, cleaning, tightening of electrical connections of C &R pannels, D C /AC Diatrbution pannels etc
1
-
-
... More
Painting of outdoor equipments (Transformers, MK's, CT/PT/CVT, Protection wall, Circuit breaker, isolatores, poles etc.
1
-
-
... More
Store handling:
1.Unloading / Loading of C&R Panels, in divisional store Pampore Including manual Carriage within store yard).
1
-
-
... More
Unloading / Loading of ,angle iron, Tor steel , tower material in divisional store Pampore Including manual Carriage within store yard).
1
-
-
... More
Unloading / Loading of CT/CVT/PT/CB etc in divisional store Pampore Including manual Carriage within store yard).
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements