Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Eprocure
Opening Date30 May 2019
Closing Date18 Jun 2019
Tender Amount₹ 45,00,000
Costs
EMD
₹ 25,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_PDD_75514_1Bid Award Id
ViewTender No
STDS/11 of 2019-20Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Replacement of damaged 11 KV Espout bushing for 11 KV OCB/VCB Panels of Vijai/Alind/ABB/ Joti/Electricfield/Easun Reyrolle/Cropmton & Greaves/ S&S/ Alsthom/Sudhir make.
1
-
-
... More
Replacement of damaged 11 KV Panel bush rods (Copper alloys) for 11 KV OCB/VCB Panels of Vijai/Alind/ABB/ Joti/Electricfield/Easun Reyrolle/Cropmton & Greaves/ S&S/ Alsthom/Sudhir make.
1
-
-
... More
Supply,fixing,installing,commissioning,testing of fresh 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in panel
1
-
-
... More
Fixing,installing,commissioning,testing of fresh 11KV Vacuum Interruptor by way of Replacement of Damaged/Burnt Out 11KV Vacuum Interruptor of same composition,type,make already installed in panel
1
-
-
... More
Supply,fixing,installing,commissioning,testing of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards
1
-
-
... More
Fixing,installing,commissioning,testing of fresh 11KV C.T by way of Replacement of Damaged/Burnt Out 11 KV C.T of same ratio,type,make and class already installed in panel
1
-
-
... More
Supply,fixing,installing,commissioning,testing of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel confirming to IEC 60044-1-2000 standards
1
-
-
... More
Fixing,installing,commissioning,testing of fresh 11KV P.T by way of Replacement of Damaged/Burnt Out 11 KV P.T of same ratio,type,make and class already installed in panel
1
-
-
... More
Replacement of damaged clamps (A.A) confirming to IS:617 standards
1
-
-
... More
Replacement of damaged clamps (Bi-Metallic) confirming to IS: 1285 standards
1
-
-
... More
Replacement of damaged equipments (33KV Post Insulators) confirming to IEC 61109/92-93 with latest amendments
1
-
-
... More
Replacement of damaged equipments (33K VCB Bushes complete assembly) confirming to IS:2099 standard
1
-
-
... More
Supply,fixing,installing,commissioning,testing of fresh Replacement of damaged 33KV C.T(3-core) of (300-150/5-5A) confirming to IEC:185 and IS:2705 (part-1 to 4) standards
1
-
-
... More
Fixing,installing,commissioning,testing of fresh Replacement of damaged 33KV C.T(3-core) of (300-150/5-5A) confirming to IEC:185 and IS:2705 (part-1 to 4) standards
1
-
-
... More
Supply,fixing,installing,commissioning,testing of fresh Replacement of damaged 33KV P.T of (110V/√3) confirming to IS:3156 (part-I to Part-III)
1
-
-
... More
Fixing,installing,commissioning,testing of fresh Replacement of damaged 33KV P.T of (110V/√3) confirming to IS:3156 (part-I to Part-III)
1
-
-
... More
Rectification,Re-Alignment,setting right the mechnical section /electrical section of 11KV Oil circuit Breakers which includes replacement of damaged parts
1
-
-
... More
Rectification,Re-Alignment,setting right the mechnical section /electrical section of 11KV VCB's which includes replacement of damaged parts :- a) Tripping Mechanism
1
-
-
... More
b) Modification of Mechanism
1
-
-
... More
c) Re- Setting links
1
-
-
... More
d) Replacement of operating shaft
1
-
-
... More
e) Shower contact
1
-
-
... More
f) Spring charging motor
1
-
-
... More
g) interuptor housing 3 bus Scheme
1
-
-
... More
h) interuptor housing Single Bus Scheme
1
-
-
... More
i) Isolating sockets
1
-
-
... More
j) Closing Mechanism (Replacement)
1
-
-
... More
Supply,fixing,installing,commissioning,testing of fresh 11 KV Panels Spares for Replacement:- a) Volt Meter / KV meter 11 Kv /110 V
1
-
-
... More
b) Ampere meter
1
-
-
... More
c) Selector Switch 16 amps
1
-
-
... More
d) Indication Indicators (LED type)
1
-
-
... More
e) Press Push button
1
-
-
... More
f) Master Tripping Relay
1
-
-
... More
g) HRC base with fuse 16 Amps
1
-
-
... More
h) Panel control re wiring including 2.5 Sq mm flexible wire
1
-
-
... More
i) Connecting Ribs
1
-
-
... More
j) Auxiliary switch
1
-
-
... More
k) Auxiliary Relay - 30 A
1
-
-
... More
l) Trip Circuit Supervision Relay
1
-
-
... More
m) Tripping / Closing Coils 36 V DC (Relacement with former)
1
-
-
... More
n) Breaker close /open switch (TNC)
1
-
-
... More
Repairing of 33 KV C&R Panel by way of replacement of:- a) Replacement of Bucholz , winding temperature, Oil Temperature, Alarm Relay
1
-
-
... More
b) Replacement of Master Tripping Relay
1
-
-
... More
c) Replacement of Closing Trip Switch (TNC)
1
-
-
... More
d) Panel Control re wiring along with 2.5 Sq mm flexible wire, Connecting ribs , bunching wire, Ferruling, thimbling etc.
1
-
-
... More
e) Deco Spray Painting
1
-
-
... More
f) MW Meter (Replacement)
1
-
-
... More
g) Energy Meter (Replacement)
1
-
-
... More
h) Electronic Hooter (Replacement)
1
-
-
... More
Repairing of 33 KV VCB by way of replacement of:- a) 33 KV Vacuum Interrupter (Replacement)
1
-
-
... More
b) 33KV Porcelain Insulator (Replacement)
1
-
-
... More
c) Operating Rods(Replacement)
1
-
-
... More
d) Closing Coils with Housing (Replacement)
1
-
-
... More
e) Tripping Coil with Housing (Replacement) Crampton / Megavin / Slinider / Alaston / ABB Make
1
-
-
... More
f) Motor charging 240V, 1-ȸ,0.1KV
1
-
-
... More
g) Contactor (Replacement)
1
-
-
... More
Replacement of damaged equipments (33K VCB Bushes complete assembly) confirming to IS:2099 standard
1
-
-
... More
Providing, fixing and installation of 33KV Isoltaors 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (with earthing blade)
1
-
-
... More
Fixing and installation of 33KV Isoltaors 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (with earthing blade)
1
-
-
... More
Providing, fixing and installation of 33KV Isoltaors 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (without earthing blade)
1
-
-
... More
Fixing and installation of 33KV Isoltaors 1250 Amps heavy duty confirming to IS:9921 / IEC-62271-102 standards (without earthing blade)
1
-
-
... More
Supply,installation,testing,commissioning of 11KV ,3 core heat shrinkable cable jointing straight kits (outdoor Type) suitable for already installed 11KV Xlpe Power Cable confirming to IS:13573/1993 with latest ammendments if any (3M or equivalent) 400mm²/300mm²/240mm²/185mm²,3-core
1
-
-
... More
Providing,fixing,testing,commissioning of 11KV cable end kits (outdoor Type) 3M or equivalent 400mm²/300mm²/240mm²/185mm²,3-core
1
-
-
... More
Fixing,testing,commissioning of 11KV cable end kits (outdoor Type) 3M or equivalent 400mm²/300mm²/240mm²/185mm²,3-core
1
-
-
... More
Providing,fixing,testing,commissioning of 11KV cable end kits (Indoor Type) 400mm²/300mm²/240mm²/185mm²,3-core
1
-
-
... More
Supply, Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 400 sqmm with Heat shrink cable termination kits (outdoor as well as indoor ).
1
-
-
... More
Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 400 sqmm with Heat shrink cable termination kits (outdoor as well as indoor ).
1
-
-
... More
Supply, Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 300 sqmm with Heat shrink cable termination kits (outdoor as well as indoor ).
1
-
-
... More
Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 300 sqmm with Heat shrink cable termination kits (outdoor as well as indoor ).
1
-
-
... More
Supply, Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 240 sqmm with Heat shrink cable termination kits (outdoor as well as indoor ).
1
-
-
... More
Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 240 sqmm with Heat shrink cable termination kits (outdoor as well as indoor ).
1
-
-
... More
Supply, Installation, Testing & Commissioning of 11 KV XLPE Aluminum Power Cables, armoured 3C 185 sqmm with Heat shrink cable termination kits (outdoor as well as indoor ).
1
-
-
... More
Supply, Installation, Testing & Commissioning of Surge Arrestors Station Type,30KV Grade, Non Linear Resistor Type, as per specification.
1
-
-
... More
Replacment of damaged PCB of 36 V DC Battery Charger
1
-
-
... More
Replacment of Damaged Servo cell of 36 V DC battery Charger
1
-
-
... More
Replacment of Damaged 2V 200AH Batteries Exide /Amron/Amaraja/Sukam make
1
-
-
... More
Replacment of damaged 12V 200AH batteries Exide/Amron/Amaraja/Sukam
1
-
-
... More
Replacment of Damaged 12V 63AH batteries Exide/Amron/Amaraja/Sukam
1
-
-
... More
Repair of damaged Voltage stablizer 5KVA
1
-
-
... More
Supply of 2HP Water motor with fettings sutiable for 1" dia pipes with 200feet 1" long rubber pipe
1
-
-
... More
Repair /replacment of LT wiring of Receiving Satations
1
-
-
... More
Replacement of damaged LED Light with 50W LED with Fittings Complete
1
-
-
... More
Supply, Installation, Testing & Commissioning of 11 KV isolator ,600 Amp Gang operated Operated Switch, horizontal type with Earthing Blade, Terminal Box & Auxiliary Switch, as per specifications.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements