Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Feb 2025
Closing Date20 Mar 2025
Tender Amount₹ 30,41,000 
Notes
Download

Costs

Summary

Sitc For Creation Of 400kva Distributions With Htlt Line For Bus Stand At Thandi Khui Jakh Under The Jurisdiction Of Executive Engineer Electric Division Vijaypur On Turnkey Basis

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, GI Cross arms, GI Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminum paint coated including all necessary Nut & Bolts & Washers etc.

330

10

-

... More
Supply, Installation, Testing & Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

10

-

... More
Supply, Installation, Testing & Commissioning of 11 KV Horn Gap Fuse Set 3 Phase 200 A .

1

10

-

... More
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type

1

10

-

... More
Providing & Fixing of 300 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type

88

10

-

... More
Providing & Fixing of Distribution Box for 400 kVA DTR with MCCB for incomer (630 AMP) & SFU's for Outgoing Circuits.

2

10

-

... More
Providing of Earthing of substation --Excavation of earth pit of dia. 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GIStrip for neutral earthing of size 25 mm x 3 mm for connection of transformer body ,G.O Set &lightening arrestor as per IS 2629/85, GI nuts &bolts ,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

3

10

-

... More
Painting the steel tubular pole with 1 coat of red oxide and 1 coat of aluminium paint.

2

10

-

... More
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

10

-

... More
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

10

-

... More
Providing & Fixing of Anti Climbing device with Clamps

2

10

-

... More
Providing & Fixing of Danger Plates with Clamps

2

-

-

... More
Providing & Fixing of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia. GI stranded wire complete

2

10

-

... More
Providing and fixing of P G Clamps

6

10

-

... More
SCOPE OF WORK FOR LAYING OF HT LINE ON 9 MTR ST POLES USING ACSR WEASEL CONDUCTOR .

-

-

-

... More
Supply, Transportation, Erection of 9 Mtr Long ST Pole (SP-33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.

6

10

-

... More
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, GI V-Cross arms, GI Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.

115

10

-

... More
Supply, Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire

0.78

10

-

... More
Supply Installation, Testing & Commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm

18

10

-

... More
Supply Installation, Testing & Commissioning of 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm

12

10

-

... More
Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete

4

10

-

... More
Providing & Fixing of Danger Plates with Clamps

6

10

-

... More
Providing & Fixing of Anti Climbing device with Clamps

6

10

-

... More
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip

6

10

-

... More
Supply erection testing and commissioning of 11 KV XLPE insulated armoured cable 3c Al conductor of size 120 sqmm to be laid under ground in HDPE pipe of 150 mm diameter. (2 Ckts.)

250

10

-

... More
Red oxide for steel tubular poles one coat

6

-

-

... More
Aluminium paint for steel tubular poles one coat each

6

10

-

... More
Providing and fixing of Aluminium Jointing sleeves

2

10

-

... More
Providing and fixing of P G Clamps

4

10

-

... More
Cement bottoming of steel poles as per REC norms

6

10

-

... More
SCOPE OF WORK FOR LAYING OF LT LINE ON 8 MTR STEEL TUBULAR POLES USING LT AB Cable

-

-

-

... More
Supply, Transportation, Erection of 8 Mtr Long ST Pole (SP-15) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.

21

10

-

... More
120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x 70 mm²) XLPE (1.1kV, 3+1 C, Al)

0.8

10

-

... More
Suspension/Tension Clamp with eye hook

21

10

-

... More
Straigh Through Cable Jointing Kit

1

10

-

... More
Galvanized Nuts and Bolts.

12

10

-

... More
Providing & Fixing of Danger Plates with Clamps

21

10

-

... More
Providing & Fixing of Anti Climbing device with Clamps

21

10

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

21

10

-

... More
Pole Disribution boxes with Aluminium bus bar for 3 phase load along with all the fittings

10

-

-

... More
PG Clamps

15

10

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

6

10

-

... More
SCOPE OF WORK FOR ERECTION OF ISOLATION POINTS .

-

-

-

... More
Supply, Transportation, Erection of 9 Mtr Long ST Pole (SP-33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.

2

10

-

... More
GI V cross-arm with top Bracket including clamp

30

10

-

... More
GI Channel/Angle Iron including clamps

50

10

-

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

10

-

... More
30 mm² ACSR Conductor

15

10

-

... More
PG Clamps for 30 mm² ACSR Conductor

3

10

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

6

10

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanized Nuts and Bolts

1

10

-

... More
Danger Plates with Clamps

2

-

-

... More
Anti-Climbing Device with Clamps

2

-

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. (for 2 No ST poles and 1 No GO Switch)

2

-

-

... More
Red Oxide

2

-

-

... More
Aluminium Paint

2

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole

2

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.