Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Nov 2024
Closing Soon23 Dec 2024
Tender Amount₹ 12,08,000
Costs
EMD
₹ 24,160Document Cost
₹ 600Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_265397_1Tender No
TLMD-IV/e-NIT/05 0F 2024-25Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://PowerDevelopmentDepartment
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
220KV SF6 Breaker
3
8830
26490
... More
132KV SF6 Breaker
3
7947
23841
... More
33KV VCB
3
6622
19866
... More
Current Transformers :- Checking of bellow expansion, Checking of oil leakage in terminal box, Checking of primary connection strips, Checking of healthiness of gaskets,Checking the tightness of all connections including earthing of PF terminal, Cleaning of marshalling box and junction box, Checking cleanliness / tightness of all electrical connections including earthing of all marshalling boxes, CT secondary terminal, space heater and illumination, healthiness of secondary terminal bushing, checking of oil level, measurement of IR value tightening of jumpers, CT anylises with the help of CTA etc.
-
-
-
... More
220KV CT
4
1816
7264
... More
132KV CT
7
1362
9534
... More
33KV CT
6
545
3270
... More
CVT's / PT's :- Visual checking of earthing HF point (in case it is not being used for PLCC,Checking of any breakage or cracks in cementing joint, Cleaning of CVT capacitor stacks and tightness of terminal connections, Checking of space heater and illumination,Checking and tightness of all connections including earth connections Cleaning of marshalling box and junction box, Checking of healthiness of gaskets, Checking of neutral earthing in CVT, healthiness of all gaskets and oil level. Measurement of IR value and tightening of all connections and droppers.
-
-
-
... More
220KV
6
2299
13794
... More
132KV
11
1724
18964
... More
33KV
8
690
5520
... More
Surge Arrestors :- Checking of leakage current(third harmonic resistive current), Testing of counters and leakage current meters, Cleaning of insulators, Checking of earth connections between surge arrester,surge monitor and earth, Checking of leakage current after cleaning of porcelain surface, cleaning of LA insulators. Measurement of IR value and tightening of droppers and testing of counter and leakage of current meters,
-
-
-
... More
220kV
4
2299
9196
... More
132kV
6
1724
10344
... More
33kV
4
431
1724
... More
Isolators :- Maintenance of linkages including transmission gears, stopper bolts. Cleaning of auxiliary switch contacts and greasing with silca grease, cleaning of support insulators, termination contacts, checking of elecctrical / mechanical interlocks with E/S and CB, mounting bolts, alignment, nuts, pins, space heater, illumination, healthiness of gaskets, auxiliary contacts, alignment of earthing blades, operation of earth switch, almunium / copper flexible conductor, earth connections of structures and MB. lubrication of operating mechanism, hinges lock joints, levers, bearings, main contacts, cleaning of post insulators, tightening of clamps.
-
-
-
... More
220kV
15
1683
25245
... More
132kV
14
1346
18844
... More
33kV
6
673
4038
... More
Bus Bar:- Replacement of damaged/burnt drapers or jumpers (Emergency work)
7
2749
19243
... More
BUS BARS:REPLACEMENT OF BUSBARS OF SINGLE CONDUCTOR WITH SIZE 0.4/0.5 ACSR INCLUDING REPLACEMENT OF DISC INSULATORS IF REQUIRED/TIGHTENING OF CLAMPS ETC
5
5854
29270
... More
Bus Bar:- Replacement of damaged Disc insulators
3
2127
6381
... More
Gantry Columns and Beams :- Tightening of all nuts / bolts and providing of missing nuts / bolts and damaged members
-
-
-
... More
220kV
8
3010
24080
... More
132kV
10
2408
24080
... More
33kV
2
1505
3010
... More
Illumination System :- Checking of healthiness of fittings in station buildings, outdoor switch yard, repairing and replacement if required, lighting of panels. Tightening of terminals etc.
15
7040
105600
... More
Battery Bank: Checking and cleaning of battery cell terminals, application of patrolum gelly, if required, conduction of battery impendence test and discharge test checking voltage temperature, current, sp. Gravity of individual cells as well as terminals voltage.
4
1400
5600
... More
Battery Charger :- Checking of control cards, measurement of test point voltage values, testing of DC earthfault and U/V relays, IR measurement of charger transformer, checking of earthing etc. Checking of charger panel / DCDB for electrical connections, cleanliness etc.
4
2083
8332
... More
Protection System :- Checking of relays and application of CCl4 for cleaning, replacement of worn out / defunct relays, checking and replacement of control wiring, if required, primery & secondery injection testing etc.
20
2695
53900
... More
DG Sets:- Maintenance of DG Sets including cleaining of oil and air filters, checking of exhauste system of DG sets, tightening of all mechanical equipments and allelectrical connections etc
3
19500
58500
... More
Maintenance of ATS Switches,Fire Alarm Systems etc
3
5000
15000
... More
Maintenance of dewatering Motors/Pumps including replacement of burntout coils etc
16
6000
96000
... More
Auxillary Transformers:- Checking of local and remote operation of accessories, Inspection and testing of transformer including drying/ replacement of silica gel,checking of buchhloz relay,surge relay,conservator oil level indicator, temp. sensors, topping of oil, cooling system, alarm / trip circuit. Measurement of IR Values, dielectric strength of transformer oil and BDV of oil, checking of marshalling box of OLTC, reactor, NGR, T.B of PDR, Bucholz relay, surge relay. External cleaning of radiators, bushings etc.
5
2734
13670
... More
Maintenance of High Mast Lights including replacement of old Lights with LED's ( Cost of material included)
3
25000
75000
... More
Earthing Mat :- Measurment of earth resistivity, checking of electrical continuity of equipment earthings, tightening of earthing connectors, removal of rust from bolted earth connectors and tightening.
6
5449
32694
... More
DC Distribution Board :- Checking of connections, wiring, replacement of wiring if needed and checking of healthiness of all D/C lights.
6
3532
21192
... More
Fire Protection System:- Refilling of fire fighting CO2 and dry chemical powder gas cylinders, providing of sand baskets.
6
423
2541
... More
Deweeding of switch yards at the Grid stations (Half yearly)
8217
12
100000.89
... More
Dismentling of equipment CTs/PTs/LAs/CVTs
10
5000
50000
... More
Shifting/stacking / Reaarrangement of old tower material/ galvanised/ bend material in the divisional store yard in order to facilitate the easy movement of men and material and to keep the store materials in arranged way. (Average lead 200M)
142.69
350
49997.15
... More
Shifting/stacking of old material (Serviceable / un serviceable) in the divisional store yard including conductor,TMT, Angle and Channels, scrapes etc. in order to facilitate the easy movement of men and material and to keep the store materials in arranged way.(Average lead 200M)
142.69
350
49997.15
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%