Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Works
Eprocure
Opening Date6 Dec 2024
Closing Date28 Dec 2024
Tender Amount₹ 85,18,000 
Notes
Download

Costs

Summary

Ked/97 Of 2024-25 Dated 03.12.2024 For Shifting Of Electric Utilities From Bani To Basohli-bani Road 70.00 To 89.00km In Respect Of Jpdcl Electric Division Kathua On Turnkey Basis

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
GI Channel x-arm includingclaps and braces

91.32

-

-

... More
30 mm² ACSR Weasel Conductor

1.8

-

-

... More
PG Clamps for ACSR weasel conductor

6

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

36

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

9

-

-

... More
Galvanized Nuts and Bolts

10

-

-

... More
Danger Plates with Clamp

10

-

-

... More
Anti Climbing Devices with clamps

10

-

-

... More
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip

10

-

-

... More
Redoxide Paint

10

-

-

... More
Aluminium Paints

10

-

-

... More
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole

10

-

-

... More
Aluminium Jointing Sleeves

6

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

3

-

-

... More
Dismantling of old HT Line along with allied material & write back of material at Division Store

0.6

-

-

... More
Erection of 11 KV Tapping point Dhadi Morh to Forest Check Post for re-alignment of line in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long Pole(ST-410 SP-33 )

2

-

-

... More
GI V cross-arm/Horizontal with top Bracket including clamp

34

-

-

... More
GI Channel/ angle iron including Clamps

52

-

-

... More
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type

1

-

-

... More
30 mm² ACSR Weasel Conductor

15

-

-

... More
PG Clamps for 30mm2 ACSR conductor

3

-

-

... More
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm

6

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm

3

-

-

... More
Galvanized Nuts and Bolts

1

-

-

... More
Danger Plates with Clamps

2

-

-

... More
Anti-Climbing Device with Clamps

2

-

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Cement bottoming 1:2:4 Mix as per REC Standars

2

-

-

... More
Aluminium Paint

2

-

-

... More
Red oxide paint

2

-

-

... More
Supply, Installation, Testing & Commissioning of 250 KVA Sub Station alongwith allied material at Bani-I in respect of JPDCL Electric Sub Division Basohli (Existing 250KVA Transformer to be shifted at new Sub Station site)

-

-

-

... More
Shifting of existing 250 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer at new Sub Station Site

1

-

-

... More
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type

1

-

-

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

-

-

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

1

-

-

... More
185 mm² (2 Ckt) Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type.

44

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

2

-

-

... More
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
GI Channel/Angle/Flat of sizes including clamps.

300

-

-

... More
Galvinized Nuts and Bolts.

8

-

-

... More
Earthing of substation -Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Wedege connectors /PG clamps

6

-

-

... More
Danger plate with clamps

1

-

-

... More
GI Barbed wire for ani Clambing

15

-

-

... More
3 Ph 4 Wire Trivector meter with CT

1

-

-

... More
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole

2

-

-

... More
Painting of poles Red oxide

2

-

-

... More
Painting of poles Aluminum Paint

2

-

-

... More
Sundary items like Aluminium Lugs, Jumpers , binding tape

1

-

-

... More
Dismantling of old Sub Station along with allied material & write back of material at Division Store

1

-

-

... More
Erection of LT line on 8 Mtrs. ST poles with ACSR Weasel Conductor on 3 Phase 4 wire at Sira in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

10

-

-

... More
GI U-Clamp for Shackle insulators

40

-

-

... More
16 KN Shackle insulators

40

-

-

... More
30 mm² ACSR Weasel Conductor

2

-

-

... More
Galvanized Nuts and Bolts

10

-

-

... More
Danger Plates with Clamp

10

-

-

... More
Anti climbing Devices with Clamp

10

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

10

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

10

-

-

... More
Red Oxide Paint

10

-

-

... More
Al Paint

10

-

-

... More
Aluminium Jointing Sleeves

10

-

-

... More
LT line Spacers

4

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Dismantling of old LT Line along with allied material & write back of material at Division Store

0.5

-

-

... More
Erection of HT line on 11 Mtrs. ST poles with ACSR Weasel Conductor from Check Post to Bus Stand Bani in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
11 Mtr. Long pole (ST-410 SP 56)

16

-

-

... More
GI V cross-arm with top Bracket including clamp

220.16

-

-

... More
GI Channel x-arm includingclaps and braces

121.76

-

-

... More
30 mm² ACSR Weasel Conductor

2.4

-

-

... More
PG Clamps for ACSR weasel conductor

9

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

48

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

6

-

-

... More
Galvanized Nuts and Bolts

16

-

-

... More
Danger Plates with Clamp

16

-

-

... More
Anti Climbing Devices with clamps

16

-

-

... More
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip

16

-

-

... More
Redoxide Paint

16

-

-

... More
Aluminium Paints

16

-

-

... More
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole

16

-

-

... More
Aluminium Jointing Sleeves

6

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

4

-

-

... More
Dismantling of old HT Line along with allied material & write back of material at Division Store

0.8

-

-

... More
Erection of LT line on 9 Mtrs. ST poles with ACSR Weasel Conductor on 2 Phase 3 wire in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

10

-

-

... More
GI U-Clamp for Shackle insulators

30

-

-

... More
16 KN Shackle insulators

30

-

-

... More
30 mm² ACSR Weasel Conductor

2

-

-

... More
Galvanized Nuts and Bolts

10

-

-

... More
Danger Plates with Clamp

10

-

-

... More
Anti climbing Devices with Clamp

10

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

10

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

10

-

-

... More
Red Oxide Paint

10

-

-

... More
Al Paint

10

-

-

... More
Aluminium Jointing Sleeves

4

-

-

... More
LT line Spacers

9

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

3

-

-

... More
Dismantling of old LT Line along with allied material & write back of material at Division Store

0.5

-

-

... More
Supply, Installation, Testing & Commissioning of 250 KVA Sub Station alongwith allied material at Bani-II in respect of JPDCL Electric Sub Division Basohli (Existing 250KVA Transformer to be shifted at new Sub Station site)

-

-

-

... More
Shifting of existing 250 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer at new Sub Station Site

1

-

-

... More
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type

1

-

-

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

-

-

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

1

-

-

... More
185 mm² (2 Ckt) Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type.

44

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

2

-

-

... More
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
GI Channel/Angle/Flat of sizes including clamps.

300

-

-

... More
Galvinized Nuts and Bolts.

8

-

-

... More
Earthing of substation -Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Wedege connectors /PG clamps

6

-

-

... More
Danger plate with clamps

1

-

-

... More
GI Barbed wire for ani Clambing

15

-

-

... More
3 Ph 4 Wire Trivector meter with CT

1

-

-

... More
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole

2

-

-

... More
Painting of poles Red oxide

2

-

-

... More
Painting of poles Aluminum Paint

2

-

-

... More
Sundary items like Aluminium Lugs, Jumpers , binding tape

1

-

-

... More
Dismantling of old Sub Station along with allied material & write back of material at Division Store

1

-

-

... More
Erection of LT line on 9 Mtrs. ST poles with ACSR Weasel Conductor on 2 Phase 3 wire st Bani -II in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

7

-

-

... More
GI U-Clamp for Shackle insulators

28

-

-

... More
16 KN Shackle insulators

28

-

-

... More
30 mm² ACSR Weasel Conductor

1.4

-

-

... More
Galvanized Nuts and Bolts

7

-

-

... More
Danger Plates with Clamp

7

-

-

... More
Anti climbing Devices with Clamp

7

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

7

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

7

-

-

... More
Red Oxide Paint

7

-

-

... More
Al Paint

7

-

-

... More
Aluminium Jointing Sleeves

4

-

-

... More
LT line Spacers

5

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Dismantling of old LT Line along with allied material & write back of material at Division Store

0.4

-

-

... More
Supply, Installation, Testing & Commissioning of 250 KVA Sub Station alongwith allied material at Bani-III in respect of JPDCL Electric Sub Division Basohli (Existing 250KVA Transformer to be shifted at new Sub Station site)

-

-

-

... More
Shifting of existing 250 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer at new Sub Station Site

1

-

-

... More
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type

1

-

-

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

-

-

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

1

-

-

... More
185 mm² (2 Ckt) Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type.

44

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

2

-

-

... More
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
GI Channel/Angle/Flat of sizes including clamps.

300

-

-

... More
Galvinized Nuts and Bolts.

8

-

-

... More
Earthing of substation -Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Wedege connectors /PG clamps

6

-

-

... More
Danger plate with clamps

1

-

-

... More
GI Barbed wire for ani Clambing

15

-

-

... More
3 Ph 4 Wire Trivector meter with CT

1

-

-

... More
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole

2

-

-

... More
Painting of poles Red oxide

2

-

-

... More
Painting of poles Aluminum Paint

2

-

-

... More
Sundary items like Aluminium Lugs, Jumpers , binding tape

1

-

-

... More
Dismantling of Sub Station along with allied material & write back of material at Division Store

1

-

-

... More
Erection of HT line on 9 Mtrs. ST poles with ACSR Weasel Conductor on 2 Phase 3 wire at Bani -III in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

8

-

-

... More
GI U-Clamp for Shackle insulators

32

-

-

... More
16 KN Shackle insulators

32

-

-

... More
30 mm² ACSR Weasel Conductor

1.6

-

-

... More
Galvanized Nuts and Bolts

8

-

-

... More
Danger Plates with Clamp

8

-

-

... More
Anti climbing Devices with Clamp

8

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

8

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

8

-

-

... More
Red Oxide Paint

8

-

-

... More
Al Paint

8

-

-

... More
Aluminium Jointing Sleeves

4

-

-

... More
LT line Spacers

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Dismantling of old HT Line along with allied material & write back of material at Division Store

0.4

-

-

... More
Erection of HT line on 9 Mtrs. ST poles with ACSR Weasel Conductor Bani -II feeder near Dhaggar Bridge in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

10

-

-

... More
GI V cross-arm with top Bracket including clamp

137.6

-

-

... More
GI Channel x-arm includingclaps and braces

76.1

-

-

... More
30 mm² ACSR Weasel Conductor

1.5

-

-

... More
PG Clamps for ACSR weasel conductor

6

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

30

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

6

-

-

... More
Galvanized Nuts and Bolts

10

-

-

... More
Danger Plates with Clamp

10

-

-

... More
Anti Climbing Devices with clamps

10

-

-

... More
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip

10

-

-

... More
Redoxide Paint

10

-

-

... More
Aluminium Paints

10

-

-

... More
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole

10

-

-

... More
Aluminium Jointing Sleeves

6

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Dismantling of old HT Line along with allied material & write back of material at Division Store

0.5

-

-

... More
SITC of 100 KVA Sub Station at Sira Basohli in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
100 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.)

1

-

-

... More
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type

1

-

-

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

-

-

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

1

-

-

... More
185 mm² (2 Ckt) Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type.

44

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

2

-

-

... More
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
GI Channel/Angle/Flat of sizes including clamps.

300

-

-

... More
Galvinized Nuts and Bolts.

8

-

-

... More
Earthing of substation -Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Wedege connectors /PG clamps

6

-

-

... More
Danger plate with clamps

1

-

-

... More
GI Barbed wire for ani Clambing

15

-

-

... More
3 Ph 4 Wire Trivector meter with CT

1

-

-

... More
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole

2

-

-

... More
Painting of poles Red oxide

2

-

-

... More
Painting of poles Aluminum Paint

2

-

-

... More
Sundary items like Aluminium Lugs, Jumpers , binding tape

1

-

-

... More
Dismantling of Sub Station along with 100KVA Transforme and allied material & write back of material at Division Store

1

-

-

... More
Erection of LT line on 9 Mtrs. ST poles with ACSR Weasel Conductor on 3 Phase 4 wire at Sira in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

8

-

-

... More
GI U-Clamp for Shackle insulators

32

-

-

... More
16 KN Shackle insulators

32

-

-

... More
30 mm² ACSR Weasel Conductor

1.6

-

-

... More
Galvanized Nuts and Bolts

8

-

-

... More
Danger Plates with Clamp

8

-

-

... More
Anti climbing Devices with Clamp

8

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

8

-

-

... More
Red Oxide Paint

8

-

-

... More
Al Paint

8

-

-

... More
Aluminium Jointing Sleeves

4

-

-

... More
LT line Spacers

5

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Dismantling of old LT Line along with allied material & write back of material at Division Store

0.4

-

-

... More
Erection of HT line on 9 Mtrs. ST poles with ACSR Weasel Conductor from Receiving Station Sarthali to Backon and from realignment of line in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

6

-

-

... More
GI V cross-arm with top Bracket including clamp

82.56

-

-

... More
GI Channel x-arm includingclaps and braces

45.66

-

-

... More
30 mm² ACSR Weasel Conductor

0.9

-

-

... More
PG Clamps for ACSR weasel conductor

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

18

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanized Nuts and Bolts

6

-

-

... More
Danger Plates with Clamp

6

-

-

... More
Anti Climbing Devices with clamps

6

-

-

... More
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip

6

-

-

... More
Redoxide Paint

6

-

-

... More
Aluminium Paints

6

-

-

... More
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole

6

-

-

... More
Aluminium Jointing Sleeves

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

1

-

-

... More
Dismantling of old HT Line along with allied material & write back of material at Division Store

0.3

-

-

... More
Erection of 11 KV Tapping point in respect JPDCL Electric Division Kathua

-

-

-

... More
9 Mtr. Long Pole(ST-410 SP-33 )

2

-

-

... More
GI V cross-arm/Horizontal with top Bracket including clamp

34

-

-

... More
GI Channel/ angle iron including Clamps

52

-

-

... More
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type

1

-

-

... More
30 mm² ACSR Weasel Conductor

15

-

-

... More
PG Clamps for 30mm2 ACSR conductor

3

-

-

... More
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm

6

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm

3

-

-

... More
Galvanized Nuts and Bolts

1

-

-

... More
Danger Plates with Clamps

2

-

-

... More
Anti-Climbing Device with Clamps

2

-

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Cement bottoming 1:2:4 Mix as per REC Standars

2

-

-

... More
Aluminium Paint

2

-

-

... More
Red oxide paint

2

-

-

... More
Erection of LT line on 8 Mtrs. ST poles with ACSR Weasel Conductor on 3 Phase 4 wire at Sarthali Approx. 0.2Km in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

4

-

-

... More
GI U-Clamp for Shackle insulators

16

-

-

... More
16 KN Shackle insulators

16

-

-

... More
30 mm² ACSR Weasel Conductor

0.8

-

-

... More
Galvanized Nuts and Bolts

4

-

-

... More
Danger Plates with Clamp

4

-

-

... More
Anti climbing Devices with Clamp

4

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

4

-

-

... More
Red Oxide Paint

4

-

-

... More
Al Paint

4

-

-

... More
Aluminium Jointing Sleeves

4

-

-

... More
LT line Spacers

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

1

-

-

... More
Dismantling of old LT Line along with allied material & write back of material at Division Store

0.2

-

-

... More
Erection of HT line on 9 Mtrs. ST poles with ACSR Weasel Conductor from Backon to Tath Gowar and from realignment of line in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

4

-

-

... More
GI V cross-arm with top Bracket including clamp

55.04

-

-

... More
GI Channel x-arm includingclaps and braces

30.44

-

-

... More
30 mm² ACSR Weasel Conductor

0.6

-

-

... More
PG Clamps for ACSR weasel conductor

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

12

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanized Nuts and Bolts

4

-

-

... More
Danger Plates with Clamp

4

-

-

... More
Anti Climbing Devices with clamps

4

-

-

... More
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip

4

-

-

... More
Redoxide Paint

4

-

-

... More
Aluminium Paints

4

-

-

... More
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole

4

-

-

... More
Aluminium Jointing Sleeves

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

1

-

-

... More
Dismantling of old HT Line along with allied material & write back of material at Division Store

0.2

-

-

... More
Supply, Installation, Testing and Commissioning of 100KVA Sub Station on ST Poles Backon to road side to other side in respect of JPDCL, Electric Sub Division Basohli

-

-

-

... More
100 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2 ( new), IS1180 part -1, 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 mtrs. Suitable cable of ratings.(Aluminium Wound upto 200 KVA, Copper Wound for 250 KVA or Higher KVA rattings.)

1

-

-

... More
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type

1

-

-

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

-

-

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

1

-

-

... More
185 mm² (2 Ckt) Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type.

44

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

2

-

-

... More
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
GI Channel/Angle/Flat of sizes including clamps.

300

-

-

... More
Galvinized Nuts and Bolts.

8

-

-

... More
Earthing of substation -Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Wedege connectors /PG clamps

6

-

-

... More
Danger plate with clamps

1

-

-

... More
GI Barbed wire for ani Clambing

15

-

-

... More
3 Ph 4 Wire Trivector meter with CT

1

-

-

... More
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole

2

-

-

... More
Painting of poles Red oxide

2

-

-

... More
Painting of poles Aluminum Paint

2

-

-

... More
Sundary items like Aluminium Lugs, Jumpers , binding tape

1

-

-

... More
Dismantling of Sub Station along with 100KVA Transforme and allied material & write back of material at Division Store

1

-

-

... More
Supply, Installation, Testing & Commissioning of 25 KVA Sub Station on ST poles at Salari (Ludera) Backon in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
25 KVA, 11/0.433-0.250kV;50 Hz, Al wound Distribution Transformer of latest Energy efficiency level-2( new), IS1180 part -1, 2014 as per latest upto date amendment

1

-

-

... More
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type

1

-

-

... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

1

-

-

... More
11 kV Horn Gap Fuse Set 3 Phase 200A

1

-

-

... More
25 mm² Single core cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type.

44

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

2

-

-

... More
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

3

-

-

... More
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap

250

-

-

... More
Galvinized Nuts and Bolts.

8

-

-

... More
32/63 Amps TPN switch Disconnector fuse unit

1

-

-

... More
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole

2

-

-

... More
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.

3

-

-

... More
LT Distribution Box for 16 KV DTR with MCCB for incommer and SFU's for out going Circuits

1

-

-

... More
Dismantling of old transformer along with allied material & write back of material at Division Store

1

-

-

... More
Erection of HT line on 9 Mtrs. ST poles with ACSR Weasel Conductor from Salari (Ludera) Backon in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

8

-

-

... More
GI V cross-arm with top Bracket including clamp

110.08

-

-

... More
GI Channel x-arm includingclaps and braces

60.88

-

-

... More
30 mm² ACSR Weasel Conductor

1.2

-

-

... More
PG Clamps for ACSR weasel conductor

3

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

24

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

6

-

-

... More
Galvanized Nuts and Bolts

8

-

-

... More
Danger Plates with Clamp

8

-

-

... More
Anti Climbing Devices with clamps

8

-

-

... More
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip

8

-

-

... More
Red oxcide Paint

8

-

-

... More
Aluminium Paints

8

-

-

... More
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole

8

-

-

... More
Aluminium Jointing Sleeves

8

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Dismantling of old HT Line along with allied material & write back of material at Division Store

0.4

-

-

... More
Erection of LT line on 8 Mtrs. ST poles with ACSR Weasel Conductor on 3 Phase 4 wire at Salari (Ludera) Backon in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
8Mtr. Long pole (ST-410 SP 15)

8

-

-

... More
GI U-Clamp for Shackle insulators

32

-

-

... More
16 KN Shackle insulators

32

-

-

... More
30 mm² ACSR Weasel Conductor

1.6

-

-

... More
Galvanized Nuts and Bolts

8

-

-

... More
Danger Plates with Clamp

8

-

-

... More
Anti climbing Devices with Clamp

8

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

8

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

8

-

-

... More
Red Oxide Paint

8

-

-

... More
Al Paint

8

-

-

... More
Aluminium Jointing Sleeves

8

-

-

... More
LT line Spacers

7

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

2

-

-

... More
Dismantling of old LT Line along with allied material & write back of material at Division Store

0.4

-

-

... More
Conversion of LT line on 8 Mtrs. ST poles with ACSR Weasel Conductor 1 phase to 3 Phase 4 wire at Thati Gowar in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
GI U-Clamp for Shackle insulators

20

-

-

... More
16 KN Shackle insulators

20

-

-

... More
50 mm² ACSR Rabbit Conductor

1

-

-

... More
Galvanized Nuts and Bolts

10

-

-

... More
LT line Spacers

10

-

-

... More
Erection of LT line on 9 Mtrs. ST poles with ACSR Weasel Conductor on 2 Phase 3 wire in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
9 Mtr. Long pole (ST-410 SP 33)

2

-

-

... More
GI U-Clamp for Shackle insulators

4

-

-

... More
16 KN Shackle insulators

4

-

-

... More
30 mm² ACSR Weasel Conductor

0.4

-

-

... More
Galvanized Nuts and Bolts

2

-

-

... More
Danger Plates with Clamp

2

-

-

... More
Anti climbing Devices with Clamp

2

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

2

-

-

... More
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip

2

-

-

... More
Red Oxide Paint

2

-

-

... More
Al Paint

2

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

1

-

-

... More
Dismantling of old LT Line along with allied material & write back of material at Division Store

0.1

-

-

... More
Guart Netting of Single Span for Distribution line in respect of JPDCL Electric Sub Division Basohli

-

-

-

... More
GI Channel X arms including clamps and braces

660

-

-

... More
Nuts and bolts

60

-

-

... More
GI Wire 6 SWG & 8 SWG

320

-

-

... More
Eye Bolts

80

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.