Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date12 Jul 2024
Closing Date12 Aug 2024
Tender Amount₹ 4,43,50,000
Costs
EMD
₹ 8,87,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_252887_1Bid Award Id
ViewTender No
TLMD-III/UDH/ 05 of 2024-25 Dated-11-07-2024Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Single phase, 50 c/s 145KV Current Transformers (900-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic
current 100KA(peak), Class A insulation, Burden 20 VA
3
-
-
132 kv Neutral Current Transformer with Current Rating 1A/5A and VA Burden
15VA
1
-
-
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated
accessories, auxiliaries.
3
-
-
132KV Control and Relay Panel for Transformer bay completely wired including Substation automation supporting IEDs/numerical relays including Differential relay, Directional 3 O/C 1 E/F protection and numerical
communicable REF protection relay. (Iec 61850 PROTOCOL SCADA COMPATIBLE)
1
-
-
132KV Post Insulators Solid Core Type, Power Frequency Withstand
Voltage 275KVP Dry lightning impulse withstand voltage ± 650 (KVP)
6
-
-
33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec)
outdoor type with all accessories and auxiliaries
2
-
-
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
2
-
-
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing
Blades
3
-
-
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with Two Earthing Blades
1
-
-
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current
25KA(peak), Class A insulation, Burden 20 VA
6
-
-
Single phase, 50 c/s outdoor 33KV PT (33/√3) KV/ (110/√3)V with Highest
System Voltage36KV, One min power freq withstand 70KVrms
4
-
-
Single Phase 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated
accessories, auxiliaries.
6
-
-
33KV Control and Relay Panel for Transformer Bay completely wired including Substation automation supporting IEDs/numerical relays Iec 61850 SCADA COMPATIBLE.
1
-
-
33KV Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95KVP Dry lightning impulse withstand voltage ± 170 (KVP)
12
-
-
33KV Control and Relay Panel for Line/Feeder completely wired including Substation automation supporting IEDs/numerical relays ec 61850 SCADA COMPATIBLE.
1
-
-
Galvanised Structures
4
-
-
Galvanised Nuts and Bolts
1.9
-
-
3.5 Core, 25 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
200
-
-
2 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
920
-
-
5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
6650
-
-
8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
795
-
-
10 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
1000
-
-
14 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
275
-
-
16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
1290
-
-
19 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
680
-
-
2 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
285
-
-
4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
660
-
-
4 Core, 16 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
135
-
-
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self- supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns. (132 KV Bay
2
-
-
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self- supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns. (33kv bay)
2
-
-
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
2.25
-
-
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm.
Minimum Ultimate strength (Tensile strength) shall be 70 KN.
54
-
-
Single Suspension Fittings For Single 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
42
-
-
Single Tension Fittings For Twin 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
18
-
-
Single Suspension Fittings For Twin 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
12
-
-
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia.
Creepage total 430 mm and 260 mm protected.
540
-
-
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia.
Creepage total 430 mm and 260 mm protected.
330
-
-
T Clamps 500mm2 /500mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
42
-
-
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
48
-
-
Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162
21
-
-
P I Clamps made of Alluminium Alloy and shall comply in all respects with
IS:5561-1970 (latest edition)
21
-
-
P G Clamps made of Alluminium Alloy and shall comply in all respects with
IS:5561-1970 (latest edition)
81
-
-
Earth Wire 7/3.15mm
450
-
-
Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS
ground wire
18
-
-
Cable Trays of size 400mm x 3000mm made of M.S angles 40x40x6mm,40x6 Flat.
540
-
-
Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm,40x6 Flat.
330
-
-
Main Duct of Size 900mm x 600mm with 6 mm M.S Chequered Trench Covers of size 500 x 1000 mm
12
-
-
Main Duct of Size 900mm x 600mm with concrete grade M15 of size 500 x 1000 mm
60
-
-
Sub Main Duct of Size 600mm x 450mm with concrete grade M15 of size 700x500 mm
60
-
-
Tee off Duct: 150mm sand filled HDPE pipes from Sub main to Equipments in the outdoor area
40
-
-
Main Duct of Size 1200mm x 1200mm with 6 mm M.S Chequered Trench Covers of size 1300x500 mm
6
-
-
Main Duct of Size 1200mm x 1200mm with 75mm Concrete Covers grade M15 of size 1300x500 mm
30
-
-
Sub Main Duct of Size 600mm x 600mm with 75mm Concrete Covers grade M15 of size 700x500 mm
50
-
-
Tee off Duct: 150mm sand filled HDPE pipes from Sub main to Equipments in the outdoor area
30
-
-
Earth Mat (40mm dia steel bars) as per approved design, Galavanised Iron (75mm x 12mm/ 50mm x 6 mm) risers for Equipment and Structural
Earthing
1800
-
-
Concreting of yard & Laying Of Gravel
2300
-
-
Rail Track
70
-
-
Fire protection Walls
2
-
-
Laying of Transformer foundations for Three phase 20 MVA Transformer (as per Drawing)
1
-
-
Construction of Oil sump & Tank for three phase 20 MVA Transformer
1
-
-
Laying of 132KV SF6 foundations (as per Drawing)
1
-
-
Laying of 132 KV Isolator foundations (as per Drawing)
4
-
-
Laying of 132 KV Post Insulator foundations (as per Drawing)
6
-
-
Laying of 132 KV CT foundations (as per Drawing)
3
-
-
Laying of 132KV L.A foundations (as per Drawing)
3
-
-
Laying of 33KV Isolator foundations (as per Drawing)
6
-
-
Laying of 33KV VCB foundations (as per Drawing)
2
-
-
Laying of 33KV CT foundations (as per Drawing)
7
-
-
Laying of 33KV LA foundations (as per Drawing)
6
-
-
Laying of 33KV PI foundations (as per Drawing)
3
-
-
Laying of 33KV PT foundations (as per Drawing)
4
-
-
Draining of transformer oil in drums (empty drums to be arranged by contractior)
1
-
-
Unloading of transformer from foundation, dragging upto loading site(20mtr) loading of transformer for transportation to GSS Kishtwar
1
-
-
Transportation of power transformer including all associated accessories i. e transformer oil,panel,transforner parts, neutral CT etc. from GSS Khellani to GSS Kishtwar (including insurance etc.)
1
-
-
Unloading of transformer, dragging upto foundation(50mtr), loading there of on foundation at GSS Kishtwar
1
-
-
Dehydration,Desludging and filtration of transformer oil including replacement of gaskets, painting etc. at GSS Kishtwar
1
-
-
Construcion of approach road from exiting 20 MVA Xmer No. 2 to Ratle bay
200
-
-
Construction of drain 0.60 mtr. X 0.60 mtr. In 1 :3:6 concrete with 10 mm plaster
120
-
-
Construction of R/wall in 1:6 masonary
80
-
-
ITEMS TO BE SUPPLIED AT DIVISIONAL STORES
-
-
-
SAFETY BELTS ISI MARK
10
-
-
SAFETY SHOES SI MARK
10
-
-
SAFETY HELMET ISI MARK
10
-
-
RUBBER SAFETY GLOVES ISI MARK 33 KV
10
-
-
Primary injection set, INPUT VOLTAGE 230 v ac, CURRENT SOURCE 10A-2000A, output power 6.0 V upto 15 KVA
1
-
-
Steel pulley 5 ton Heavy duty
3
-
-
Thermo vision Device for Grid station & Transmission lines (night vision with range upto 50 mtr)
1
-
-
Sf6 Gas filling kit for 132 KV & 220 Kv SF6 Breakers
2
-
-
Aliminium ladder Double extension 8 mtr long
2
-
-
VACCUM CLEANER FOR PANELS
3
-
-
3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 1250 Amps of 3 phase, 50 c/s and 31.5KA for 1 second).
1
-
-
33KV VCB (36 KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 3 sec) outdoor type with all accessories and auxiliaries
1
-
-
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current
25KA(peak), Class A insulation, Burden 20 VA
3
-
-
Single phase, 50 c/s 145KV Current Transformers (900-600-300/1-1-1-1-1 A or as per site specifications), 31.5KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA
3
-
-
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated
accessories, auxiliaries.
3
-
-
Single phase, 50 c/s outdoor 33KV PT (33/√3) KV/ (110/√3)V with Highest System Voltage36KV, One min power freq withstand 70KVrms
3
-
-
Single Phase 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated
accessories, auxiliaries.
6
-
-