Power Development Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date21 Nov 2023
Closing Date13 Dec 2023
Tender Amount₹ 41,10,000 
Notes
Download

Costs

Summary

Survey, Design, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 100kva Sub Station Each At Zero Stage Involving 2 Sites And Ist Stage At Wss Theru Sujanpur Along With Laying Of 11kv Ht Line For Stages 0 And Ist

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
GI Channel/Angle Iron including clamps and braces

156

-

-

... More
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type

3

-

-

... More
ACSR Weasel Conductor

0.05

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

18

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

9

-

-

... More
Galvanized Nuts and Bolts

6

-

-

... More
Danger Plates with Clamps

6

-

-

... More
Anti-Climbing Device with Clamps

6

-

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip (25x3)mm. (for 6 No ST Poles and 3 No GO Switch)

9

-

-

... More
Aluminium Paint of reputed make

6

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole

6

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

6

-

-

... More
Supply, Transportation, Carriage, Erection, Testing and Commissioning for Laying of 11KV HT Line for stages 0 and Ist

-

-

-

... More
9 mtr long Pole ST-410, SP33

48

-

-

... More
GI V cross-arm with top Bracket including clamp

578

-

-

... More
GI Channel X-arm including clamps and braces

620

-

-

... More
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type

2

-

-

... More
ACSR Weasel Conductor

7.81

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

123

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

42

-

-

... More
Galvinized Nuts and Bolts

48

-

-

... More
Danger Plates with Clamps

48

-

-

... More
Anti-Climbing Device with Clamps

48

-

-

... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.

48

-

-

... More
Aluminium Paint

48

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole

48

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

12

-

-

... More
Supply, Fabrication,Erection, Testing and commissioning of 100KVA Distribution substation for stage 0 (2 sites) and Stage 1st

-

-

-

... More
11/0.433KV;50Hz, 100KVA Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings.

3

-

-

... More
9 mtr long Pole ST-410, SP33

6

-

-

... More
Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type

3

-

-

... More
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type

3

-

-

... More
11kV Horn Gap Fuse set 3-phase, 200 Amp

3

-

-

... More
185sqmm cable 1.1kv grade, PVC insulated stranded conductor FRLS type

132

-

-

... More
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

9

-

-

... More
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm

9

-

-

... More
GI Channel/Angle/Flat of different sizes including clamps

900

-

-

... More
Galvanised Nuts & Bolts

24

-

-

... More
Earthing of substation - Excavation of earthing pit of dia 650mm & depth 3000mm, installation of Earthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm x 3mm for connection of transformer body, GO set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover

9

-

-

... More
LT distribution box for 100KVA DTR with MCCB for incomer & SFU's for outgoing circuits

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete

6

-

-

... More
Wedge connection/PG Clamps

18

-

-

... More
Danger Plates with clamps

3

-

-

... More
G.I Barbed Wire for anti climbing

45

-

-

... More
Prodigy meter of reputed make

3

-

-

... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/Pole

6

-

-

... More
Painting of Poles Aluminium Paint

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.