Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Eprocure
Opening Date19 Oct 2018
Closing Date25 Oct 2018
Tender Amount₹ 40,89,000
Costs
EMD
₹ 82,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Rural Electrification Works Of Ganderbal District In The State Of Jammu And Kashmir Under Saubhagya.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_PDD_63668_1Bid Award Id
ViewTender No
EDGV/E-NIT No 66 of 2018-19Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for 11 mtr Long ST Poles (540, SP-56) for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)
NOTE: Please refer Pole drawings for details 11 KV Line
12
-
-
Supplying and erection of GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. NOTE: Please refer Pole drawings for details (11 KV Line)
1765
-
-
Supplying and erection of GI channel (75x40x6 mm) cross arms for H-frames, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm angle support for guard netting including clamps as per REC standard. (11 KV Line)
977
-
-
Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN)
348
-
-
Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (11 KV Line)
73
-
-
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard. (11 KV Line)
30
-
-
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (11 KV Line)
128
-
-
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language (11 KV Line)
128
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (11 KV Line)
128
-
-
Supplying and fixing of Galvanized Nuts and Bolts of sizes. (11 KV Line)
128
-
-
Supply and fixing of Parallel Grove (PG) clamps, binding wire etc (11 KV Line)
6
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size (Note conductor to be provided by the Department) 50 mm2 ACSR ( Rabbit) (11 KV Line)
18
-
-
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) (11 KV Line)
128
-
-
Supply and Fixing of Aluminium Jointing Sleeves
18
-
-
Supply and Fixing of Guard Netting complete with earthing connection on both sides using Cradle guard wire 8 SWG GI wire and lashing of 10 SWG GI wire including GI x-arms with clamps and braces, threaded eye bolts, turn buckles and binding wire, nut bolts etc., (11 KV Line)
12
-
-
Supply and Installation of 11 KV, 400 Amp Double break Isolator with Earthing Blade complete with base Channels, operating handle etc. at Source - R/Stn. (11 KV Line)
6
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 25kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (Note: The transformer to be provided by JKPDD). (Distribution Sub Station)
5
-
-
Supply and installation of LT bi-metalic connectors for making connection from DT bush rod to aluminium cables (Distribution Sub Station)
20
-
-
Supply and fixing of LT Distribution Box for 25KVA DTR with TPN MCCBs short ckt rating 16 KA for incomer 40 Amp ( 25 KVA)/100 Amp(63KVA)/160 Amp (100 KVA) and suitable MCCBs for outgoing circuits with terminal extensions. (Distribution Sub Station)
5
-
-
Supply and installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (Distribution Sub Station)
15
-
-
Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (Distribution Sub Station)
5
-
-
Supply and installation of 11 kV, G.O AB Switch , 3-phase, 200A (Distribution Sub Station)
5
-
-
Supply and installation of 11 kV Horn, Gap Fuse 3-phase 100A
5
-
-
Supply and fixing of Un Armoured Single Core XPLE, FRLS Cable (50 mm2 for 25kVA,) (Distribution Sub Station)
220
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (540 SP 33) with pit excavation
(Note: The poles shall be provided by JKPDD) (Distribution Sub Station)
10
-
-
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level plaster and curing of concrete in size of 600x600x1700mm for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)
NOTE: Please refer Pole drawings for details (Distribution Sub Station)
10
-
-
Supplying and erection of GI channel/angle cross arms including fixing GI channels ( 100x50x6mm) / (75x40x6 mm) / angles(50x50x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles. (Distribution Sub Station)
1500
-
-
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.
10
-
-
Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth). Note: For LA Earth 1 pipe shall be kept separate (Distribution Sub Station)
15
-
-
Supplying and erection of 11kV Danger Plates with clamps with writing in English and Regional Language (Distribution Sub Station)
5
-
-
Supplying and fixing of Galvanized Nuts and Bolts of sizes. (Distribution Sub Station)
40
-
-
Supply and fixing of Parallel Grove (PG) clamps, Aluminum lugs for fixing cable to MCCB – 8 nos including crimping of the lugs, jumpering of DT accessories through ACSR (Note conductor to be provided by the Department) (Distribution Sub Station)
5
-
-
Supply and painting 1 coat red oxide paint and 2 coats of al (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) (Distribution Sub Station)
10
-
-
Supply and Fixing of Wedge Connectors/PG Clamps (Distribution Sub Station)
30
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (Distribution Sub Station)
10
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site , and erection of 8 Mtr. Long ST Poles (540 SP15) with pit excavation
(Note: The poles shall be provided by JKPDD) (1-Ph , LT AB Cable)
39
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (540 SP 33) for road/line crossings, with pit excavation
(Note: The poles shall be provided by JKPDD) (1-Ph , LT AB Cable)
4
-
-
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level plaster and curing of concrete in size of 600x600x1700mm for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)
NOTE: Please refer Pole drawings for details (1-Ph , LT AB Cable)
43
-
-
Supplying and fixing of Suspension/Tension clamps with eye hooks (1-Ph , LT AB Cable)
43
-
-
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard. (1-Ph , LT AB Cable)
8
-
-
Supplying and fixing of pole Earthing Complete by GI Spiral Earthing, 8 SWG 115 turn coil earthing as per REC J-1 drawing (1-Ph , LT AB Cable)
43
-
-
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language (1-Ph , LT AB Cable)
43
-
-
Supplying and fixing of Galvanized Nuts and Bolts of sizes. (1-Ph , LT AB Cable)
22
-
-
Supply and fixing of straight through Jointing Kit complete (1-Ph , LT AB Cable)
2
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site ,Laying, stringing and binding LT AB Cable of required size (Note AB Cable to be provided by the Department)
1x16+1x25+1x16 - AB (LT) Cable (1-Ph , LT AB Cable)
1
-
-
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) (1-Ph , LT AB Cable)
43
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (1-Ph , LT AB Cable)
43
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site , and erection of 8 Mtr. Long ST Poles (540 SP15) with pit excavation
(Note: The poles shall be provided by JKPDD) (3-Ph, LT AB Cable)
73
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (540 SP 33) for road/line crossings, with pit excavation
(Note: The poles shall be provided by JKPDD) (3-Ph, LT AB Cable)
8
-
-
Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level plaster and curing of concrete in size of 600x600x1700mm for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)
NOTE: Please refer Pole drawings for details (3-Ph, LT AB Cable)
81
-
-
Supplying and fixing of Suspension/Tension clamps with eye hooks (3-Ph, LT AB Cable)
81
-
-
Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard. (3-Ph, LT AB Cable)
16
-
-
Supplying and fixing of pole Earthing Complete by GI Spiral Earthing, 8 SWG 115 turn coil earthing as per REC J-1 drawing (3-Ph, LT AB Cable)
81
-
-
Supplying and erection of Danger Plates with clamps with writing in English and Regional Language (3-Ph, LT AB Cable)
81
-
-
Supplying and fixing of Galvanized Nuts and Bolts of sizes. (3-Ph, LT AB Cable)
41
-
-
Supply and fixing of straight through Jointing Kit complete (3-Ph, LT AB Cable)
4
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site ,Laying, stringing and binding LT AB Cable of required size (Note AB Cable to be provided by the Department)
3x50+1x35+1x16 - AB (LT) Cable (3-Ph, LT AB Cable)
3
-
-
Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) (3-Ph, LT AB Cable)
81
-
-
Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (3-Ph, LT AB Cable)
81
-
-
Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of Single Phase smart/pre-paid Energy Meter 5-30 Amp / 10-60 Amp, DLMS Compliant of accuracy class 1.0 in meter box with GI clamps on poles. (Note: The meters with meter box shall be provided by JKPDD) 1 in 1 Meter Box - For Single Consumer (Service Connection
(LT on AB Cable)
29
-
-
Supply and Installation of Main Service Distribution box with 2 no's of 40x4 mm Aluminium Bus Bars mounted on insulators. (High rating Bus Bars will be utilised for future consumers) (Service Connection
(LT on AB Cable)
29
-
-
Supplying and fixing of Earthing Complete by GI Spiral Earthing, 12 SWG 115 turn coil earthing as per REC J-1 drawing for meter box. (Service Connection
(LT on AB Cable)
29
-
-
Supply and fixing of Piercing Connectors (Service Connection
(LT on AB Cable)
1160
-
-
Installation of 16 Sq mm, 2 Core PVC Cable from AB Cable tapping point through piercing connector to MSDB
(For Single User)
(Note: Cable to be Provided by PDD) (Service Connection
(LT on AB Cable)
87
-
-
Fixing of 10 mm²/16 mm² Al Cable (2C) from MSDB to meter, 1.1K V Grade, Unarmoured, PVC Insulated Stranded Conductor FRLS type. 1 in 1 Meter Box - For Single Consumer
(Note: Cable to be Provided by PDD) (Service Connection
(LT on AB Cable)
116
-
-
Fixing of 10 mm²/16 mm² Al Cable (2C) from meter to consumer cut out, 1.1K V Grade, Unarmoured, PVC Insulated Stranded Conductor FRLS type along with GI wire(12 SWG) for Service Line Support/ Consumer Earthing. 1 in 1 Meter Box - For Single Consumer
(Note: Cable to be Provided by PDD) (Service Connection
(LT on AB Cable)
580
-
-
Providing and Laying of Single Point wiring, LED Lamp and associate acessories as per Construction Standards/Technical Specification for unelectrified Households (for Single House Hold) (Service Connection (LT on AB Cable)
29
-
-
Misc items like PVC pipe, insulation tape, binding wire, screws, thimbles etc., as required (Service Connection (LT on AB Cable)