Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Civil And Construction
Eprocure
Opening Date20 Oct 2023
Closing Date20 Nov 2023
Tender AmountRefer Documents
Costs
EMD
₹ 1,52,400Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 400 Kva, 250 Kva Sub Stations Alongwith Erection Of 11 Kv Line On 9 Mtr. St Poles, Lt Line On 8 Mtr. St Pole At Wss Brarian Under Jjm Scheme
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PDD_234034_1Bid Award Id
ViewTender No
ED/UDH/99OF 2023-24 dt 18-10-2023Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
GI Channel X-arm including clamps and Angle for braces
605
-
-
30mm² ACSR conductor
10.1
-
-
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
2
-
-
PG Clamps for 50mm sq ACSR Conductor
37
-
-
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
195
-
-
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
66
-
-
Galvanized Nuts and Bolts
65
-
-
Danger Plates with Clamps
65
-
-
Anti climbing device with clamps
65
-
-
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
65
-
-
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
65
-
-
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
32.5
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
16
-
-
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 400 KVA Sub stn. at WSS Brarian Intake (Stage First Parlakh)
-
-
-
11/0.433 KV, 3-phase distribution Transformer 400 KVA with Bimetallic Terminal Connectors Energy Level-2 Copper Wound, & with LV Cable box having detachable Aluminium Gland plate
1
-
-
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
1
-
-
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
1
-
-
11 KV Horn gap fuse set 3 phase 200 A
1
-
-
400mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
88
-
-
9 mtr. Long ST poles (ST-410 SP33)
2
-
-
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
3
-
-
GI Channel /Angle/flat of sizes including clamps
150
-
-
Galvanized Nuts and Bolts.
15
-
-
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
4
-
-
Transformer Pad/G.I Channel Bedding
300
-
-
11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
3
-
-
LT distribution box for 250 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
2
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
PG Clamps
6
-
-
Danger Plates with Clamps
1
-
-
GI Barbed wire for Anticlimbing
15
-
-
HT Trivector Meter with CT PT Unit
1
-
-
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
1
-
-
Painting of ST poles 9 mtr. Long with 1 coat of Red oxide & 2 coat of Aluminum paint.
2
-
-
RCC Foundation for Transformer as per Drg.
1
-
-
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Brarian Intake (Stage First Parlakh)
-
-
-
8 mtr. Long ST poles (ST-410 SP15)
6
-
-
GI M Clamps for shackle insulator
24
-
-
100mm² ACSR Dog Conductor
1.3
-
-
Shackle insulator
24
-
-
Galvanized Nuts and Bolts.
6
-
-
Danger Plates with Clamps
6
-
-
Anti climbing device with clamps
6
-
-
Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip
6
-
-
Painting of 8 mtr ST poles with two coat of Aluminium Paint
6
-
-
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
3
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
1
-
-
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at WSS Brarian Intake (Stage Second).
-
-
-
9 mtr. Long ST Pole (ST-410 SP-33)
27
-
-
GI V Cross -arm with top Bracket including clamps
385
-
-
GI Channel X-arm including clamps and Angle for braces
310
-
-
30mm² ACSR Weasel conductor
4.1
-
-
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
2
-
-
PG Clamps for 30mm Sq. ACSR Conductor
16
-
-
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
81
-
-
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
27
-
-
Galvanized Nuts and Bolts
27
-
-
Danger Plates with Clamps
27
-
-
Anti climbing device with clamps
27
-
-
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
27
-
-
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
27
-
-
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
13.5
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
7
-
-
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 250 KVA Sub stn. at WSS Brarian (Stage Second)
-
-
-
11/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 Copper Wound, & with LV Cable box having detachable Aluminium Gland plate
1
-
-
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
1
-
-
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
1
-
-
11 KV Horn gap fuse set 3 phase 200 A
1
-
-
300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
44
-
-
9 mtr. Long ST poles (ST-410 SP33)
2
-
-
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
3
-
-
GI Channel /Angle/flat of sizes including clamps
300
-
-
Galvanized Nuts and Bolts.
15
-
-
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
4
-
-
11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
3
-
-
LT distribution box for 250 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
1
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
PG Clamps
6
-
-
Danger Plates with Clamps
1
-
-
GI Barbed wire for Anticlimbing
15
-
-
HTTrivector Meter with CT PT Unit
1
-
-
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
1
-
-
Painting of ST poles 9 mtr. Long with 1 coat of Red oxide & 2 coat of Aluminum paint.
2
-
-
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Brarian (Stage Second)
-
-
-
8 mtr. Long ST poles (ST-410 SP15)
4
-
-
GI M Clamps for shackle insulator
16
-
-
50mm² ACSR Rabbit Conductor
0.82
-
-
LT Shackle insulator
16
-
-
Galvanized Nuts and Bolts.
4
-
-
Danger Plates with Clamps
4
-
-
Anti climbing device with clamps
4
-
-
Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip
4
-
-
Painting of 8 mtr ST poles with two coat of Aluminium Paint
4
-
-
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
2
-
-
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete