Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Power Development Department - PDD Tender

Civil And Construction
Eprocure
Opening Date7 Jan 2023
Closing Date6 Feb 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection 8 No 63kva Ss Alongwith 11 Kv On 9 Mtr Stp, Acsr Weasel And Lt At Wss Mahani(sia Dabber, Filter At Kattal) Including Tapping Point Under Jjm On Turnkey Basis

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
GI Channel X-arm including clamps and Angle for braces

340

-

-

... More
30mm² ACSR conductor

6.4

-

-

... More
PG Clamps for 30mm² ACSR conductor

25

-

-

... More
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.

110

-

-

... More
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting.

24

-

-

... More
Galvanized Nuts and Bolts

48

-

-

... More
Danger Plates with Clamps

24

-

-

... More
Anti climbing device with clamps

24

-

-

... More
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm

48

-

-

... More
Painting of 9 mtr ST poles with two coat of Aluminium Paint.

48

-

-

... More
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole

24

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete

10

-

-

... More
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT 3 phase 4 wire LT 30mm² line on 8 mtr. ST pole at WSS Mahani (Sia Dabber)

-

-

-

... More
8 mtr. Long poles (ST-410 SP15)

3

-

-

... More
GI M Clamps for shackle insulator

13

-

-

... More
30mm² ACSR Conductor

0.85

-

-

... More
Shackle insualtor

13

-

-

... More
Galvinized Nuts and Bolts.

3

-

-

... More
Danger Plates with Clamps

3

-

-

... More
Anti climbing device with clamps

3

-

-

... More
Earthing complete by GI Rod 40 mm or GI Rod 20mm 2.5 mtr. Long through GI Strip

3

-

-

... More
Painting of 8 mtr ST poles with red oxide

3

-

-

... More
Painting of 8 mtr ST poles with two coat of Aluminium Paint.

3

-

-

... More
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole

1.5

-

-

... More
AL. Jointing sleeves

1

-

-

... More
LT Line spacers

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete

1

-

-

... More
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 63 KVA Filter at WSS Mahani (Sia Dabber)

-

-

-

... More
11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Al. Wound, & with LV Cable box having detachable Aluminium Gland plate

2

-

-

... More
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type

2

-

-

... More
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical

2

-

-

... More
11 KV Horn gap fuse set 3 phase 200 A

2

-

-

... More
120mm² , 1.1 KV Grade, PVC insulated stranded conductor FRLS Type

88

-

-

... More
9 mtr. Long pole (ST-410 SP33)

4

-

-

... More
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm

6

-

-

... More
GI Channel /Angle/flat of sizes including clamps

600

-

-

... More
Galvinized Nuts and Bolts.

16

-

-

... More
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover

6

-

-

... More
11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm

6

-

-

... More
LT distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits

2

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete

4

-

-

... More
PG Clmaps

12

-

-

... More
Danger Plates with Clamps

2

-

-

... More
GI Barbed wire for Anticlimbing

30

-

-

... More
3-phase 4 wire LT Prodigy meter with box

2

-

-

... More
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole

2

-

-

... More
Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 1 coat of Red oxide

4

-

-

... More
Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 2 coat of Aluminium paint

4

-

-

... More
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at WSS Mahani (Filter at Kattal).

-

-

-

... More
9 mtr. Long ST Pole (ST-410 SP-33)

24

-

-

... More
GI V Cross -arm with top Bracket including clamps

310

-

-

... More
GI Channel X-arm including clamps and Angle for braces

175

-

-

... More
30mm² ACSR conductor

3.78

-

-

... More
PG Clamps for 30mm² ACSR conductor

14

-

-

... More
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.

57

-

-

... More
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting.

12

-

-

... More
Galvanized Nuts and Bolts

24

-

-

... More
Danger Plates with Clamps

24

-

-

... More
Anti climbing device with clamps

24

-

-

... More
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm

24

-

-

... More
Painting of 9 mtr ST poles with red oxide

24

-

-

... More
Painting of 9 mtr ST poles with two coat of Aluminium Paint.

24

-

-

... More
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole

12

-

-

... More
AL. Jointing sleeves

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete

6

-

-

... More
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT 3 phase 4 wire LT 30mm² line on 8 mtr. ST pole at WSS Mahani (Filter at Kattal).

-

-

-

... More
8 mtr. Long poles (ST-410 SP15)

3

-

-

... More
GI M Clamps for shackle insulator

13

-

-

... More
30mm² ACSR Conductor

0.85

-

-

... More
Shackle insualtor

13

-

-

... More
Galvinized Nuts and Bolts.

3

-

-

... More
Danger Plates with Clamps

3

-

-

... More
Anti climbing device with clamps

3

-

-

... More
Earthing complete by GI Rod 40 mm or GI Rod 20mm 2.5 mtr. Long through GI Strip

3

-

-

... More
Painting of 8 mtr ST poles with red oxide

3

-

-

... More
Painting of 8 mtr ST poles with two coat of Aluminium Paint.

3

-

-

... More
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole

1.5

-

-

... More
AL. Jointing sleeves

1

-

-

... More
LT Line spacers

3

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete

1

-

-

... More
Survey,Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 6 No 63 KVA Filter at WSS Mahani (Filter at Kattal).

-

-

-

... More
11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2, Al. Wound, & with LV Cable box having detachable Aluminium Gland plate

6

-

-

... More
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type

6

-

-

... More
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical

6

-

-

... More
11 KV Horn gap fuse set 3 phase 200 A

6

-

-

... More
120mm² (1ckt) 1.1 KV Grade, PVC insulated stranded conductor FRLS Type

264

-

-

... More
9 mtr. Long pole (ST-410 SP33)

12

-

-

... More
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm

18

-

-

... More
GI Channel /Angle/flat of sizes including clamps

1800

-

-

... More
Galvinized Nuts and Bolts.

48

-

-

... More
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover

18

-

-

... More
11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm

18

-

-

... More
LT distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits

6

-

-

... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete

12

-

-

... More
PG Clmaps

36

-

-

... More
Danger Plates with Clamps

6

-

-

... More
GI Barbed wire for Anticlimbing

90

-

-

... More
3-phase 4 wireLT prodigy meter with Box

6

-

-

... More
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole

6

-

-

... More
Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 1 coat of Red oxide

12

-

-

... More
Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 2 coat of Aluminium paint

12

-

-

... More
Supply of 11KV Earthing /Discharge Rod (as per relevant IS ) for earthing of line at site (Set of 3)

6

-

-

... More
Supply of Al ladder 20 feet long Heavy Duty

2

-

-

... More
Supply of 11kV GO, Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type

8

-

-

... More
Supply of Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.