Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Eprocure
Opening Date20 Jun 2024
Closing Date27 Jul 2024
Tender Amount₹ 4,97,000
Costs
EMD
₹ 10,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ked 31 Of 2024 25 Dated 19 06 2024 For Creation Of 100 Kva Sub Station Alongwith Ht Line At Hatli In Respect Jpdcl Electric Sub Division Kathua Of Electric Division Kathua Underjjm Scheme
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_250703_1Tender No
KED 31 of 2024 25 Dated 19 06 2024Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://http://www.jkpdd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
... More
11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
... More
185 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
40
-
-
... More
9 Mtr. Long Pole(WL-300 Kg )
2
-
-
... More
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
3
-
-
... More
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
300
-
-
... More
Galvinized Nuts and Bolts.
8
-
-
... More
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
3
-
-
... More
Pre fabricated LT Distribution box
1
-
-
... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
... More
Wedege connectors /PG clamps
6
-
-
... More
Danger plate with clamps
1
-
-
... More
GI Barbed wire for ani Clambing
15
-
-
... More
3 Ph 4 Wire Trivector meter with CT
1
-
-
... More
Cemetn bottoming 1:2:4 mix as per REC standerds .5 Cum/pole
2
-
-
... More
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor at Hatli in respect JPDCL Electric Sub Division Kathua of Electric Division Kathua underJJM Scheme on Turnkey Basis by way of supply Erection/ Installation,Testing Commissioning of following Material:
-
-
-
... More
9 Mtr. Long Pole(WL-300 Kg )
2
-
-
... More
GI V cross-arm/Horizontal with top Bracket including clamp
28
-
-
... More
GI Channel x-arm includingclaps and braces
15
-
-
... More
30 mm² ACSR Weasel Conductor
0.22
-
-
... More
PG Clamps for ACSR weasel conductor
3
-
-
... More
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
6
-
-
... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
3
-
-
... More
Galvanized Nuts and Bolts
2
-
-
... More
Danger Plates with Clamp
2
-
-
... More
Anti Climbing Devices with clamps
2
-
-
... More
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
2
-
-
... More
Stone Pad (300mmx300 mmx75mm)
2
-
-
... More
Aluminium Jointing Sleeves
3
-
-
... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
1
-
-
... More
Erection of 11 KV Tapping point at Hatli in respect JPDCL Electric Sub Division Kathua of Electric Division Kathua underJJM Scheme on Turnkey Basis by way of supply Erection/ Installation,Testing Commissioning of following Material:
-
-
-
... More
9 Mtr. Long Pole(WL-300 Kg )
2
-
-
... More
GI V cross-arm/Horizontal with top Bracket including clamp
34
-
-
... More
GI Channel/ angle iron including Clamps
52
-
-
... More
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
1
-
-
... More
30 mm² ACSR Weasel Conductor
15
-
-
... More
PG Clamps for 30mm2 ACSR conductor
3
-
-
... More
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
6
-
-
... More
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
3
-
-
... More
Galvanized Nuts and Bolts
1
-
-
... More
Danger Plates with Clamps
2
-
-
... More
Anti-Climbing Device with Clamps
2
-
-
... More
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
3
-
-
... More
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
... More
Ston pad(300mmx300mmx75mm)
2
-
-