Power Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Power Development Department - PDD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Date23 Nov 2024
Tender Amount₹ 47,58,600
Costs
EMD
₹ 95,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDD_263921_1Bid Award Id
ViewTender No
eNIT No. TLM-VI/10 OF 2024-25 DTD 08-11-2024Tender Authority
Power Development Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
technical specification of nit 10 ofTwining of 132kV Main and Reserve Bus Bars, Quadrupling of main and reserve 33kV bus at Grid Station Kulgam and Replacement of two numbers 33kV VCB 1250A by 1600A breaker and Replacement of 06 Number 33kV CTs by
sbd of nit 10 of Twining of 132kV Main and Reserve Bus Bars, Quadrupling of main and reserve 33kV bus at Grid Station Kulgam and Replacement of two numbers 33kV VCB 1250A by 1600A breaker and Replacement of 06 Number 33kV CTs by 800-1200-1600-1A
NIT 10 OF Twining of 132kV Main and Reserve Bus Bars, Quadrupling of main and reserve 33kV bus at Grid Station Kulgam and Replacement of two numbers 33kV VCB 1250A by 1600A breaker and Replacement of 06 Number 33kV CTs by 800-1200-1600-1A
bill of quantities of nit 10 for Twining of 132kV Main and Reserve Bus Bars, Quadrupling of main and reserve 33kV bus at Grid Station Kulgam and Replacement of two numbers 33kV VCB 1250A by 1600A breaker and Replacement of 06 Number 33kV CTs by 800
BOQ Items
... More
Tension Fittings suitable For Quad 500mm2 shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors.
60
-
-
... More
Single Suspension Fittings suitable For Quad 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.
18
-
-
... More
Disc Insulator 120 KN, PType Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
120
-
-
... More
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
160
-
-
... More
T Clamps Quad 500mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
40
-
-
... More
P I Clamps suitable for 750mmsq made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
20
-
-
... More
PG Clamps suitable for 500mmsq made of Alluminium Alloy and shall comply in all respects withIS:5561-1970 (latest edition)
30
-
-
... More
33KV VCB (36 KV, 1600 Amps of 3 phase, 50 c/s and 25KA for 3 sec) out door Circuit Breaker , including all accessories,auxiliaries and marshalling boxes/Kiosks, ( Make crompton Greaves / Hitachi /ABB/ Siemens)
2
-
-
... More
33 KV Isolator Twin Pad Clamps ( BI-Metalic )
65
-
-
... More
500 Sq mm Quad Moose to Twin Moose clamps for Bus bar to dropper
70
-
-
... More
Single phase, 50 c/s 36KV Current Transformers (1600-1200-800-400 /1-1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA including Clamps, all accessories, auxiliaries & Ancillary items . (Make ABB, SIEMENS, Mehru)
9
-
-
... More
Part B:laying & Stringing ,Testing & Commissioning of conductor and , fixing / Installation of conductor accessories viz Fittings, spacers , Disc insulators etc , and ,Pad clamps Complete in all respects inclusive of all taxes, carriages, loading & unloading and arrangments for all material, T&P etc complete in all respects.
-
-
-
... More
Laying & Strtinging of Conductor 500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN including Jumpering complete in all respects.
1.9
-
-
... More
Installation / Fixing of Spacers For Quad 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162(rate given is 1.6xrate of(spacer for twin conductor),or it can vary)
80
-
-
... More
Installation / Fixing of Tension Fittings/ Suspension fittings suitable For Quad 500mm2 shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors.
78
-
-
... More
Installation / Fixing of Disc Insulator string 120 KN, P Type Ball/ & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected. & 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
280
-
-
... More
Installation / Fixing of T Clamps Quad 500mm2, made of Alluminium Alloy /P I Clamps /P G Clamps/ Twin Moose clamps for Bus bar to dropper/ 33 KV Isolator Twin Pad Clamps ( BI-Metalic ) complete in all respects
225
-
-
... More
Part C: ERECTION: Installation Testing & Commissioning of Switch gears & modification of foudations if required, Current Transformers inclusive of all taxes, carriage, loading, unloading upto site, handling, freight, insurance T&P etc complete in all respects.
-
-
-
... More
Installation, Testing & Commissioning of 33KV VCB (36 KV, 1600 Amps of 3 phase, 50 c/s and 25KA for 3 sec) out door Circuit Breaker, including all accessories,auxiliaries and marshalling boxes / Kiosks and modification of existing foundation if required , complete in all respects.
2
-
-
... More
Installation ,Testing & Commissioning of Single phase, 50 c/s 36KV Current Transformers (1600-1200-800-400 /1-1-1-1 A or as per site specifications), 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA including Clamps, all accessories,auxiliaries & Ancillary items.
9
-
-
... More
Part D:- Dismantling of Coductor / Equipments inclusive of all, taxes carriage, loading, unloading, handling, freight, insurance T&P etc complete in all respects.
-
-
-
... More
Dismantaling of existing twin bus bars main and transfer bus by bringing down including opening of connectors, jumpers, droppers, tiers , beams etc for facilitation of conversion(twin Moose into Quad Moose System And after dismantling of conductor the surplus material shall be rolled and packed properly along with all associated hardwares and same shall be returned back to Divisional store or shall be placed properly as per the direction of in charge Engineer
0.9
-
-
... More
Dismantling of existing VCBs including returning it to the Divisional Store or Shall be Placed as per the direction of in charge Engineer
2
-
-
... More
Dismantling of existing CTs ncluding returning it to the Divisional Store or Shall be Placed as per the direction of in charge Engineer
9
-
-
... More
Part E:- CCTV
Supply, Installation, Testing & commissioning (SITC) of Survelance Cameras of approved brands along with all accessories , equipments, ancillary items inclusive of all taxes, loading, freight, T&P etc complete in all respects.
-
-
-
... More
i) CAT-6 Cable -- 500 Meter
ii) RJ 45 Connectors -- 8 No
iii) HDD - 3 TB
iv) 8 Port PoE Switch -- 01 No
v) PVC Box -- 01 No
vi) IP Bullet camera 4mp --- 07 No vii) IP Dom camera 4mp --- 01 No
(make for item No. vi & vii HICK Visionm, Godrej, Philips or equivelent brand
viii) Net work video recorder -- 01 No
ix) PVC conduits including bends & Elbow as per site requirement.
x) 36inch smart TV Make Sony, LG, Samgsung)
xi) Computer Mouse --- 01 No
xii) Rack 4U --- 01 No
xiii) All other necessary and auxillary items to complete the job.
1
-
-