Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provn Of 125 Kva Generator Set For Otm Accn Under Ge 969 Ews Job No- Lbcw/02/2024-25/rr Bn in Baramulla, Jammu & Kashmir, with an estimated contract value of Rs. 20,80,000. The bid opening date for this tender is 23-05-2025 and the last date for bid submission is 12-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date23 May 2025
Closing Soon12 Jun 2025
Tender Amount₹ 20,80,000 
Notes
Download

Costs

Summary

Provn Of 125 Kva Generator Set For Otm Accn Under Ge 969 Ews Job No- Lbcw/02/2024-25/rr Bn

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sq mm 3.5 core, all as specified.

100

-

-

... More
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 core, all as specified.

150

-

-

... More
Supply, Installing & testing and commissioning factory made and tested (including CPR. type: test certified) LT feeder pillar box out door type, platform mounted, suitable for 41 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom lock with 2 keys), internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :- (a) INCOMING (i) MCCB 4 Pole, 415 volts grade 250 Amps rating and 25 KA rupturing capacity-01 No (ii) Voltmeter 0-500 volts, Square 96 mm, finsh pattern with 3 way rotary selector switch-01 No (iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No (iv) CTs ratio 400/5 class ISI marked sets of three each (v) Indicating lamp-01 set of three (vi) Off load change over switch 250 Amps 4 pole complete -1 (b) OUTGOING (i) MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity-02 Nos (ii) MCCB 4 Pole, 415 volts grade 63 Amps rating and 25 KA rupturing capacity -03 Nos (iii) MCB DP 40 to 63 Amp, 50 Hz, 230 V with rupturing capacity 10KA. - 11 Nos

1

-

-

... More
M & L for earthing complete with galvanized Steel earth late electrode 60cm x 60cm x 6mm thick, pouried directly in ground (earth pit not less than 2.25 M deep below ground level, with top edge of the plate not less than 1.5 M below normal ground level, connected to and including Gl iron strip of size 32x6 mm flat by means of Gl bolts, nuts, and washers, protected by 40mm bore Gi light grade ISI marked pipe upto and including test points. Earthing plate shall be surrounded by alternate layers 15cm thick of charcoal or coke and common salt all around bottom and top, 20mm dia Gl medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceed ing 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggregate) including TMT reinforcement 80 mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embedded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as shown in electrical plate No-3 of SSR Part-1 and all as specified and directed.

8

-

-

... More
Excavation in trenches not exceeding 1,5 metre wide and not exceeding 1.5 metre in depth, for foundations, laying of pipes etc not exceeding 10sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in soft and loose soil, complete all as specified and directed.

19

-

-

... More
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm.in hard/dense soil, all as specified.

11

-

-

... More
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, all as specified.

8

-

-

... More
Supply and laying of burnt clay building bricks, sub-class B (old size) Designation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and directed

1

-

-

... More
M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second. yer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-I Note:-Sand shall be fine sand as specified for plastering.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.