The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair And Maintenance Of Lt Oh Line Lt Panels Ug Cables With Other Connected Items Under Ge Nagrota in Jammu, Jammu & Kashmir, with an estimated contract value of Rs. 45,00,000. The bid opening date for this tender is 09-05-2025 and the last date for bid submission is 09-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date9 May 2025
Closing Soon9 Jun 2025
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_707421_1Tender No
CANO GEN-17/2025-2026Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M & L for Sand cushioning to under ground cable laid in trenches for laying of LT UG cable 8 cm depth before laying the cable and 15 Cm after laying and punned down to depth of 10 cm as per MES SSR Part -I ( 2009) complete all as specified & directed.
95
-
-
... More
M & L for Brick covering abutting each other with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat all as directed.
6784
-
-
... More
M & L for Old Brick covering abutting each other with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ obtained from excavation complete all as specified & directed.
10176
-
-
... More
Supply and fix DWC pipe for cable protection with outer dia 50 mm and inner dia 38 mm including suitable size of coupler for connection of pipe complete all as specfied and directed. Note : Pipe are manufactured as per IS 16205 ( Part-24) have a smooth internal surface and corrugated external surface for cable protection
890
-
-
... More
Supply and fix DWC pipe for cable protection with outer dia 40 mm and inner dia 32 mm including suitable size of coupler for connection of pipe complete all as specfied and directed. Note : Pipe are manufactured as per IS 16205 ( Part-24) have a smooth internal surface and corrugated external surface for cable protection
1250
-
-
... More
Supply and fix DWC pipe for cable protection with outer dia 77 mm and inner dia 63 mm including suitable size of Coupler for connection of pipe complete all as specfied and directed. Note : Pipe are manufactured as per IS 16205 ( Part-24) have a smooth internal surface and corrugated external surface for cable protection
550
-
-
... More
Supply, laying, jointing and testing XLPE cable insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified and directed.
50
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 240 Sqmm 3.5core, complete all as specified and directed
350
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 185 Sqmm 3.5 core, complete all as specified and directed
200
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 150 Sqmm 3.5 core, complete all as specified and directed
100
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 120 Sqmm 3.5 core, complete all as specified and directed
100
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 95 Sqmm 3.5 core, complete all as specified and directed
500
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 70 Sqmm 3.5 core, complete all as specified and directed
500
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 50 Sqmm 3.5 core, complete all as specified and directed
500
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 35 Sqmm 3.5 core, complete all as specified and directed
500
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 25 Sqmm 4 core, complete all as specified and directed
1000
-
-
... More
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 16 Sqmm 4 core, complete all as specified and directed
1500
-
-
... More
Supply, laying, jointing and testing XLPE cable insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 10 Sqmm 4 core complete all as specified and directed .
500
-
-
... More
Supply, laying, jointing and testing XLPE cable insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified and directed .
500
-
-
... More
Supply, laying, jointing and testing XLPE cable insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 6 Sqmm 2 core complete all as specified and directed .
200
-
-
... More
M & L for Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor heat shrinkable cable termination type joint complete with jointing material and acessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm. complete all as specified & directed.
4
-
-
... More
M & L for Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor heat shrinkable cable termination type joint complete with jointing material and acessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm. complete all as specified & directed.
4
-
-
... More
M & L for Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor heat shrinkable cable termination type joint complete with jointing material and acessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified & directed.
3
-
-
... More
S & F in Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed.
1200
-
-
... More
S & F in Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed.
1400
-
-
... More
S & F in Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 16 Sqmm complete all as specified and directed.
800
-
-
... More
M & L for Steel tubing galvanized(Light grade) 100 mm bore conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete all as specified and directed..
20
-
-
... More
M & L for Steel tubing galvanized(Light grade)50mm bore conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete all as specified and directed..
20
-
-
... More
M & L for Steel tubing galvanized(Light grade)40mm bore conforming to IS -1239 for passing cable under road /floor or fixing to poles for protection of underground cable complete all as specified and directed..
20
-
-
... More
Labour only for re-stringing restraching ACSR conductor laid over, over head LT line on steel / PCC poles after removing binding from insulator and rewinding the conductor with insulator including providing spacer and new binding wire jumpering provide with after restraining and removing unavoidable sags in the line and Trimming of tree and branches on LT line for min clearance ccomplete all as specified & directed.
40
-
-
... More
Supply, Fixing , Commissioning and testing of CPRI approved outdoor factory made cubical type LT Feeder Pillar box powder coated suitable for 415 V, 3 Phase , 4 wire 50 Hz , AC Supply system fabricated from MS sheet totally encloused ,dust, weather & vermin proof , 3.00 mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick having TPN aluminium busbar of capacity 500 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement, with MCCB 4P 400 Amp, 36 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables with glands including control wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer on supporting angle iron frame incl. taking out old unserviceable pillar box complete all as specified and directed Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
3
-
-
... More
M & L for Feeder pillar box out door type ‘factory made’CPRI approved duly powder coated made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement, with MCCB FP 250 Amp, 25 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, on supporting angle iron frame incl. taking out old unserviceable pillar box complete all as specified and directed Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
2
-
-
... More
M & L for Feeder pillar box CPRI approved out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 250 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement, with MCCB FP 200 Amp, 25 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer on supporting angle iron frame incl. taking out old unserviceable pillar box, complete all as specified and directed Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
6
-
-
... More
S&F in repair/replacement commissioning and testing of outdoor cubical type factory made LT Feeder piller box as per CPRI approved duly powder coated, IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.0 mm thick for outer shell having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, with following accessories complete all as specified and directed Note:- Feeder piller box shall be mounted on 50x50x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm gradewd stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel. angle iron shall be painted with two coat of synthetic enameled paint over one coat of red oxide primer) on supporting angle iron frame incl. taking out old unserviceable pillar box
(a) Onload Change over switch 315 Amp 4 Pole - 01 No (b) MCCB 250 Amp 4 pole 35/36 KA Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 01 No. (c) Alum bus bar 400 Amp TPN - 01 Set (d) Digital Multifuntional meter Showing V,I, PF , HZ etc with suitable CT ratio (e) Indicator lamp LED type (RYB) complete - 01 set (f) MCCB 4 Pole, 200 Amp, 35/36 KA,Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 03 No. (g) MCCB 3 Pole, 100 Amp, 25 KA,Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 01 No.
2
-
-
... More
S&F in repair/replacement commissioning and testing of outdoor cubical type factory made LT Feeder pillar box as per CPRI approved duly powder coated , IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.0 mm thick for outer shell having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, with following accessories complete all as specified and directed by Engrineer-in-Charge.
Note:- Feeder piller box shall be mounted on 50x50x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm gradewd stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel. angle iron shall be painted with two coat of synthetic enameled smoke grey paint over a coat of red oxide primer)
(a) Onload Change over switch 400 Amp 4 Pole - 01 No.
(b) MCCB 250 Amp 4 pole 35/36 KA Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 01 No. (c) Alum bus bar 500 Amp TPN - 01 Set (d) Digital Multifuntional meter Showing V,I, PF , HZ etc with suitable CT ratio (e) Indicator lamp LED type (RYB) complete - 01 set (f) MCCB 4 Pole, 250 Amp, 35/36 KA,Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 03 Nos. (g) MCCB 3 Pole, 160 Amp, 25 KA,Adjustable Thermal & Adjustable Magnetic setting Ics = 100% of Icu - 01 No.
2
-
-
... More
Supply, installation and commissioning and testing of LT panel cubical type factory made CPRI approved duly powder coated suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge
Incoming:-
(a) MCCB 4 pole, 250 Amp, 36 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 Nos
(b) Aluminium bus bar 400 Amp TPN - 04 Nos
(c) Digital voltmeter 0-500 volts with selector switch - 01 No
(d) Digital Amp meter 0-300 Amp with selector switch & CT - 01 No
(e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 Set
Outgoing:-
(a) MCCB 4 pole, 160 Amp, 25 KA, 415 volts AC- 02 Nos
(b) MCCB 4 pole, 125 Amp, 25 KA, 415 volts AC- 01 Nos (c) MCCB 4 pole, 100 Amp, 16 KA, 415 volts AC- 02 Nos
2
-
-
... More
Supply, installation and commissioning and testing of LT panel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge
Incoming:-
(a) MCCB 4 pole, 250 Amp, 36 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 Nos
(b) Aluminium bus bar 400 Amp TPN - 04 Nos
(c) Digital voltmeter 0-500 volts with selector switch - 01 No
(d) Digital Amp meter 0-300 Amp with selector switch & CT - 01 No
(e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 Set
Outgoing:-
(a) MCCB 4 pole, 160 Amp, 25 KA, 415 volts AC- 01 Nos
(b) MCCB 4 pole, 100 Amp, 25 KA, 415 volts AC- 01 Nos (c) MCCB 4 pole, 63 Amp, 16 KA, 415 volts AC- 01 Nos
1
-
-
... More
S&F commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following incluidng taking out the old unserviceable panel complete all as specified and directed Note:- Feeder piller box shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. Incoming :-
(a) MCCB 630 Amp 4 pole 45 KA Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 01 Nos
(b) Alum bus bar 800 Amp TPN - 01 Set
(c) Digital voltmeter 0-500 volts with suitable PT and selector switch - 01 No (d) Digital Amp meter 0-1000 Amp with selector switch & suitable CT - 01 N o (e) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 set
Outgoing :-
(a) MCCB 4 Pole, 400 Amp, 20 KA,Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 01 Nos
(b) MCCB 3 Pole, 250 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 02 Nos
(c) MCCB 3 Pole, 160 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 02 Nos
1
-
-
... More
S&F commissioning and testing of CPRI approved outdoor cubical type LT Feeder piller box out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge
Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
23
-
-
... More
S&F in replacement of fabrication and installation of feeder pillar box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket and with MCB TPN 63 Amp for incoming and outgoing cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm, 400 mm long as per sample including taking down complete all as specified and as directed.
5
-
-
... More
S&F in replacement of fabrication and installation of feeder pillar box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket suitable for upto 120 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm, 400 mm long as per sample including taking down complete all as specified and as directed.
20
-
-
... More
M & L for servicing of feeder pillar box/ LT Cubical Panel, LT pannel after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and welding the hinges of Pannel door and fixing the door in original positions also checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, etc will be measured and paid under respective item in the schedule, (ii) Labour for fixing charges of the spare parts deemed to be included in the quoted rate for the respective items.
40
-
-
... More
Supply and fix wall mounted Busbar chambers 415 V, 3 phase, 4 wire 50 Hz AC supply system fabricated from stainless steel with 3 mm thick for outer cell TPN aluminium busbar of cap 63 Amp 4 pole 6 way connected with proper Nut and bolt complete all as specfied and directed
2
-
-
... More
Supply and fix wall mounted Busbar chambers 415 V, 3 phase, 4 wire 50 Hz AC supply system fabricated from stainless steel with 3 mm thick for outer cell TPN aluminium busbar of cap 100 Amp 4 pole 8 way connected with proper Nut and bolt complete all as specfied and directed
4
-
-
... More
Labour and tools for trimming tree branches up to 100 mm grith of any location around existing HT/LT OH lins giving clearance of 1.5 m on all sides after arranging shut down and taking all precaution while working on lines incl all T&P required for the purpose complete all as specified and diected by Engineer-in- charge. Note : The contractor shall arrange the tree cutting machine and vehicle mounted telescopic ladder for the same.
90
-
-
... More
S & F in Switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground levelconfirming of IS 1818 of 1972 and contineous current rating upto 200 amp and volt 11 KV complete in repairs all as specified & directed.
4
-
-
... More
M & L for taking down , Refixing existing Aluminium strip of any size from building,Store house, Bunkers with porcelain insulator and tightly fix around the building in same or other positions complete all as specified and directed. Note : Necessary Saddles and Nails required for fixing the strip on wall shall be deemed including in quored rate.
100
-
-
... More
Supply and fixing in repair of aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
50
-
-
... More
S & F in GI strip of size 25 x 4 mm for earth continuity conductor or main earthing lead fixed to wall burried in ground fixed alongwith poles complete all as specified & directed.
30
-
-
... More
M & L for preparation of old painted steel surface by cleaning, removing rust, grease and apply one coat of synthetic enamel paint of approved shade (Spray painting outside/inside surface) of the feeder pillar box / LT Panels Outdoor / Indoor type of approximate size 900 x 600 x 500 mm complete with prior permission of Engineer in Charge. Base frame with Black enamel paint (Rate quoted shall deem to be included of Numbering of Panel/ Feeder pillar) complete all as specified.and directed
40
-
-
... More
Supply and fixing in replacement of adjustable type thermal & Adjustable magnetic setting MCCB 630 amps capacity FP 415 volt with breaking cap 50 KA, complete all as specified & directed.
1
-
-
... More
Supply and fixing in replacement of adjustable type thermal & Adjustable magnetic setting MCCB 400 amps cap 4P 415 volt with breaking cap 36 KA , complete all as specified & directed.
2
-
-
... More
Supply and fixing in replacement of adjustable type thermal & Adjustable magnetic setting MCCB 3 phase 415 volt FP 250 amps with breaking cap 36 KA, complete all as specified & directed.
4
-
-
... More
Supply and fixing in replacement of adjustable type thermal & Adjustable magnetic setting MCCB 3 phase 415 volt FP 200 amps with breaking cap 36 KA, complete all as specified & directed.
4
-
-
... More
Supply and fixing in replacement of adjustable thermal and fixed magnetic setting MCCB 3 phase 415 volt FP 160 amps with breaking cap 36 KA, complete all as specified & directed.
3
-
-
... More
Supply and fixing in replacement of adjustable thermal and fixed magnetic setting MCCB 3 phase 415 volt 4P 125 amps with breaking cap 36 KA, complete all as specified & directed.
3
-
-
... More
Supply and fixing in replacement of adjustable thermal and fixed magnetic setting MCCB 3 phase 415 volt 4P 100 amps with breaking cap 36 KA, complete all as specified & directed.
5
-
-
... More
Supply and fixing in replacement of adjustable type and fixed magnetic setting MCCB 3 phase 415 volt 3 pole 250 amps with breaking cap 36 KA, complete all as specified & directed.
2
-
-
... More
Supply and fixing in replacement of adjustable type and fixed magnetic setting MCCB 3 phase 415 volt 3 pole 200 amps with breaking cap 36 KA, complete all as specified & directed.
2
-
-
... More
Supply and fixing in replacement of adjustable type and fixed magnetic setting MCCB 3 phase 415 volt 3 pole 160 amps with breaking cap 36 KA. complete all as specified & directed.
2
-
-
... More
S & F Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 100/125 amps, including taking out old unserviceable one, complete all as specified and directed
2
-
-
... More
Supply and fix aluminium lugs of any type / shape of capacity from 10 Sqmm to 25 Sqmm complete all as specified & directed.
400
-
-
... More
Supply and fix aluminium lugs of any type / shape of capacity from 35 Sqmm to 95 Sqmm complete all as specified & directed.
650
-
-
... More
Supply and fix aluminium lugs of any type / shape of capacity from 120 Sqmm to 300 Sqmm complete all as specified & directed.
430
-
-
... More
S&F Extension link four set for MCCB of cap 125/160 Amp complete all as specified & directed..
8
-
-
... More
S&F Extension four link set for MCCB of cap 250 Amp.complete all as specified & directed.
8
-
-
... More
S&F Extension four link set for MCCB of cap 400 / 630 Amp complete all as specified & directed.
4
-
-
... More
M & L for Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, complete all as specified and testing on completion all as directed. Note: The work under subject BoQ (item No. 1.00 to 71.00 ) are meant for maint of External Electric in Nagrota Mil Stn ( Including Katra, Sanjhi Chat, Charli Hill ). The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply at Station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%