The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Improvement/ Maintenance Of External Electric Supply Including Lt Poles/ Ab Cables And Allied Services At Damana Under Ge Jammu in Jammu, Jammu & Kashmir, with an estimated contract value of Rs. 50,00,000. The bid opening date for this tender is 08-05-2025 and the last date for bid submission is 04-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 May 2025
Closing Date4 Jun 2025
Tender Amount₹ 50,00,000
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_707236_1Bid Award Id
ViewTender No
GEJC-20/2025-26Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, laying and fixing of DWC HDPE pipe for protection for power cable (orange in colour) of size 75 mm dia complete with joint fittings and including cutting, jointing and clamping complete all as specified and as directed.
2000
1
2500
... More
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
3.24
1
4.050000000000001
... More
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, stay pits etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and as directed.
35.64
1
44.55
... More
Material and labour for PCC (1:2:4) type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, coping, stay pits etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and as directed.
6.48
1
8.100000000000001
... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
305.81
1
382.2625
... More
Removal of excavated material not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
269.83
1
337.28749999999997
... More
Dismantling and taking down old unserviceable steel poles any type after disconnecting all electrical connection including clearance of site complete all as specified and as per the directions of Engineer-in-Charge.
30
1
37.5
... More
Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, 9 meter long including providing synthetic enamel aluminium paint over one coat of red oxide and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed at site.
30
1
37.5
... More
Supply and fixing in repair indoor/ outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/ 4.0 x 10-50 Sqmm complete all as specified and as directed by Engineer-in-Charge.
40
1
50
... More
Supply and fixing in repair indoor/ outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm ccomplete all as specified and as directed by Engineer-in-Charge.
60
1
75
... More
Supply and fixing in repair indoor/ outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as specified and as directed by Engineer-in-Charge.
50
1
62.5
... More
Supply and fixing in repair indoor/ outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 400 Sqmm complete all as specified and as directed by Engineer-in-Charge.
20
1
25
... More
Supply and fixing in repair straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/ 4 x 25-50 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Note: - Earth work will be measured and paid separately.
10
1
12.5
... More
Supply and fixing in repair straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Note: - Earth work will be measured and paid separately.
10
1
12.5
... More
Supply and fixing in repair straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-400 Sqmm complete all as specified and as directed by Engineer-in-Charge.
Note: - Earth work will be measured and paid separately.
10
1
12.5
... More
Disconnecting and taking out defective underground cable in any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and as directed.
3400
1
4250
... More
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/ new pipe under road crossing, clamping on wall etc. complete all as specified and as directed.
Notes: - (i) Earth work, sand, bricks, removing, returning filling aluminium thimbles/ lugs will be paid separately.
(ii) Cost of laying electrical cable through new/ existing pipe under road, buildings, railway tracks, highways are included in the quoted rates.
(iii) All equipments, machinery or tools if required for laying electrical cable through new/ existing pipes are provided by the contractor without any extra cost.
700
1
875
... More
Description all as per Ser item No 20.00 here-in-before but for 3.5 core 25 Sqmm complete all as specified and as directed.
600
1
750
... More
Description all as per Ser Item No 20.00 here-in-before but for 3.5 core 35 Sqmm complete all as specified and as directed.
600
1
750
... More
Description all as per Ser item No 20.00 here-in-before but for 3.5 core 50 Sqmm complete all as specified and as directed.
400
1
500
... More
Description all as per Ser item No 20.00 here-in-before but for 3.5 core 70 Sqmm complete all as specified and as directed.
400
1
500
... More
Description all as per Ser item No 20.00 here-in-before but for 3.5 core 95 Sqmm complete all as specified and as directed.
200
1
250
... More
Description all as per Ser item No 20.00 here-in-before but for 3.5 core 120 Sqmm complete all as specified and as directed.
200
1
250
... More
Description all as per Ser Item No 20.00 here-in-before but for 3.5 core 150 Sqmm complete all as specified and as directed.
170
1
212.5
... More
Description all as per Ser Item No 20.00 here-in-before but for 3.5 core 185 Sqmm complete all as specified and as directed.
130
1
162.5
... More
Disconnecting and taking out defective underground cable any size and any type from roof, pole, pipe, floor, wall etc complete all as specified and as directed.
1800
1
2250
... More
Description all as per Ser Item No 20.00 here-in-before but for 2 core 10 Sqmm complete all as specified and as directed.
600
1
750
... More
Description all as per Ser Item No 20.00 here-in-before but for 4 core 10 Sqmm complete all as specified and as directed.
600
1
750
... More
Description all as per Ser Item No 20.00 here-in-before but for 2 core 16 Sqmm complete all as specified and as directed.
600
1
750
... More
Repair/ maint of existing burnt defective underground XLPE cable 1100 volt grade cable of any size complete with charges for tracing out the fault, cutting/ repair and jointing complete with using insulation tape, aluminium thimble, lugs, fitment of jointing kit, thimbles, necessary earth work complete all as specified and as directed.
50
1
62.5
... More
Supply and fixing stay assembly complete with all accessories, such as stay plate 230 X 230 X 6 mm3, stay rod 215 cm long and 16 mm dia with nuts including GI bow turn buckle, GI stay wire, loop type insulator etc. all as per electrical plate No 1 on SSR part 1 and as directed including taking down old unserviceable complete all as specified.
Note: - Only excavation and PCC work will be measured and paid separately.
30
1
37.5
... More
Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge.
900
1
1125
... More
Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge.
700
1
875
... More
Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge.
600
1
750
... More
Dismantling and taking down unserviceable earthing and material and labour for earthing complete with galvanized steel earth electrode plate of size 60 x 60 x 6mm thick buried directly in ground/ earth pit not less than 2.25 metre deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25 x 4mm by means of nut, bolts, washers etc to equipment/ machinery all as shown in electric plate No 3 of SSR Part - I including PCC (1:3:6) pit, pit cover 50mm thick RCC (1:2:4) type B-1 using 8mm for steel bars @10cm centre to centre both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge.
40
1
50
... More
Material and labour for fixing in repair GI tubing 50 mm bore light grade, on poles, on walls, under floors, road crossing, as required at site complete all as specified and as directed by Engineer-in-Charge.
Note: - Clamps, Nut bolts, saddle etc will be measured and paid separately.
40
1
50
... More
Description all as per Ser item No 39.00 here-in-before but for 80 mm complete all as specified and as directed.
25
1
31.25
... More
Supply and fixing in repair MCCB TPN 400 Amps, 415 Volts, 50 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection complete all as specified and all as per directions of Engineer-in-Charge.
3
1
3.75
... More
Supply and fixing in repair MCCB TPN 250 Amps, 415 Volts, 40 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection complete all as specified and all as per directions of Engineer-in-Charge.
3
1
3.75
... More
Supply and fixing in repair MCCB TPN 200 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection complete all as specified and all as per directions of Engineer-in-Charge.
3
1
3.75
... More
Supply and fixing in repair MCCB TPN 160 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection complete all as specified and all as per directions of Engineer-in-Charge.
3
1
3.75
... More
Supply and fixing in repair MCCB TPN 100 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection complete all as specified and all as per directions of Engineer-in-Charge.
3
1
3.75
... More
Supply and fixing in repair of PVC fibre separator for LT line 1100 volt overhead conductor 3 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and as directed.
200
1
250
... More
Supply and fixing in repair of PVC fibre separator for LT line 1100 volt overhead conductor 4 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and as directed.
200
1
250
... More
Supply and fixing in repair of PVC fibre separator for LT line 1100 volt overhead conductor 5 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete all as specified and as directed.
200
1
250
... More
Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 Sqmm including dismantling old thimbles of any type complete all as specified and as directed.
300
1
375
... More
Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 Sqmm including dismantling old thimbles of any type complete all as specified and as directed.
300
1
375
... More
Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 Sqmm including dismantling old thimbles of any type complete all as specified and as directed.
200
1
250
... More
Material and labour for surface cleaning of steel tubular poles LT 9 mtrs long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black and white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints including repairing and painting on coping with cement based white paint complete all as specified and as directed.
350
1
437.5
... More
Supply and fixing in repair Onload change over switch with sheet steel enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and as directed by Engineer-in-Charge.
2
1
2.5
... More
Supply and fixing in repair Onload change over switch with sheet steel enclosure 415 V, 4 pole, 200 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and as directed by Engineer-in-Charge.
2
1
2.5
... More
Supply and fixing in repair Onload change over switch with sheet steel enclosure 415 V, 4 pole, 315 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and as directed by Engineer-in-Charge.
2
1
2.5
... More
Supply and fixing and fabrication street light bracket made out of GI tubing suitable for 45/ 60/ 90 watt LED light grade upto 1.2 mtr length, bend to shape suitable for security light fitting with necessary mild steel clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
200
1
250
... More
Labour for repair/ maint to old/ unserviceable LED security/ street/ flood light of any capacity including taking down existing fitting from pole/ building for repair of driver, cable terminal block and connection wire and refixing the same in position after repair including testing complete all as specified and as directed by Engineer-in-Charge.
Note: - Spares shall be measured and paid separately under respective item.
200
1
250
... More
Taking down unserviceable street/ security light fitting of any type from the pole/ building after disconnecting electric connection carefully for replacement of drivers complete all as specified and as directed.
Note: - Repair/ replacement of spares shall be measured separately.
220
1
275
... More
Supply and fixing in repair of electronic driver of capacity 45 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
50
1
62.5
... More
Supply and fixing in repair of electronic driver of capacity 60 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
50
1
62.5
... More
Supply and fixing in repair of electronic driver of capacity 90 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
70
1
87.5
... More
Supply and fixing in repair of electronic driver of capacity 120 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
40
1
50
... More
Supply and fixing in repair of electronic driver of capacity 200 watt of existing make for LED flood light fitting complete all as specified and as directed by Engineer-in-Charge.
10
1
12.5
... More
Dismantling and taking down old unserviceable street/ security lights and material and labour for new LED street light fittings of 30 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
50
1
62.5
... More
Dismantling and taking down old unserviceable street/ security lights and material and labour for new LED street light fittings of 45 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
50
1
62.5
... More
Dismantling and taking down old unserviceable street/ security lights and material and labour for new LED street light fittings of 60 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, TOP opening separate driver compartment with frame, suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
80
1
100
... More
Dismantling and taking down old unserviceable street/ security lights and material and labour for new LED street light fittings of 90 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, TOP opening separate driver compartment with frame, suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
50
1
62.5
... More
Dismantling and taking down old unserviceable street/ security lights and material and labour for new LED street light fittings of 120 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, TOP opening separate driver compartment with frame suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
30
1
37.5
... More
Dismantling and taking down old unserviceable street/ security lights and material and labour for new LED flood light fittings of 120 watt, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
20
1
25
... More
Dismantling and taking down old unserviceable street/ security lights and material and labour for new LED flood light fittings of 200 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, power factor >0.95, working temperature range - 20º C to 60º C, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
20
1
25
... More
Taking down old unserviceable timer switches and supply and fixing of automatic street light control with infrared sensor based NATURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) single phase load of 8 KW for automation of street lights. Nature switch operation should be based on natural light Lux level. Required illuminance level for switching ON is <30 Lux and for switching OFF >30 Lux. The sensor should also have part night operation facility of minimum 4 hours to maximum 12 hours. VMS should have adjustable over and under voltage trip level and protection against phase loss, neutral loss and phase reverse including power contactors (1 no's of capacity 63 amps per phase each) and incoming (1 nos of capacity 63 amps each) - outgoing MCB (1 nos of capacity 63 amps each) and main load circuit wiring (copper) of minimum 16 Sqmm. The sensor, VMS, Power contactor, MCBs including connected items should be enclosed in a Pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54 complete all as specified and as directed.
6
1
7.5
... More
Supply and fixing SMC pole mounted box of size 10" x 8" x 4" with hinged door including clamp, nuts, bolts and washers complete all as specified and as directed and including taking down of old unserviceable junction boxes. The Box includes: -
(a) MCB single pole 10 Amp, 10 KA 'C' series mounted on din rail - 1 No.
(b) Connector block suitable for 3 phase, 4 wire minimum 16 Sqmm cable - 1 No.
120
1
150
... More
Material and labour in repair of PVC insulated and sheathed cable of size 1.5 Sqmm 3 core copper conductor multistranded 1100 volt grade 230 volts running through PVC conduit of dia 20 mm with strip clamping on poles at 3 places complete all as specified and as directed by Engineer-in-Charge.
1300
1
1625
... More
Supply and fixing in repair of 1100 Volt Arial bunched cable having 4 core conductor equal size of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 4 x 50 Sqmm + 1 x 35 Sqmm ACSR messenger conductor complete with dead end clamp, suspension clamp, Eye Hook, welding and cable jointing kit as per site requirement with the existing LT distribution system complete all as specified and as directed.
600
1
750
... More
Description all as per Ser item No 74.00 here-in-before but size 4 x 70 Sqmm + 1 x 50 Sqmm complete all as specified and as directed.
600
1
750
... More
Description all as per Ser item No 74.00 here-in-before but size 4 x 95 Sqmm + 1 x 70 Sqmm complete all as specified and as directed.
600
1
750
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements