Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Special Repair Of Existing Filtration Plant And Other Connected Items Under Ge Nagrota in Jammu, Jammu & Kashmir, with an estimated contract value of Rs. 47,50,000. The bid opening date for this tender is 22-04-2025 and the last date for bid submission is 19-05-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Apr 2025
Closing Date19 May 2025
Tender Amount₹ 47,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M& L for repair to Alum mixing system including dismantling of reduction gears having ratio 1:50 Make Radicon with replacement of agitator system, gear oil,complete all as specified and directed. Note - The rate quoted by Contractor cost of all electrical/mechanical work/materials complete required to make the lime mixing system fully functional.

1

-

-

... More
M & L for Run lead joint to spigot & socketed pipe of 300 mm bore dia complete all as specified and directed.

5

-

-

... More
Supply and fix Round three core PVC insulated & PVC sheathed copper armoured cable of size 10 Sqmm for Centrigugal motors incl. taking out of old unserviceable cable from existing position complete all as specified and directed.

500

-

-

... More
All as per ser Item No 5 here-in-before but of capacity 2 HP complete all as specified and directed.

3

-

-

... More
M & L for Plain cement concrete (1:2:4) type B-1, using crushed stone aggregate as in foundation and pillars including necessary form work, complete all as specified and directed.

10

-

-

... More
Supply and fix Clean Net Spa Leaf Rake Wire Mesh Frame With 10 feet Aluminum Pole all as specified and directed by Engr-in-Charge

2

-

-

... More
M &L for Dismantling of old one and supply & fixing new flash mixer system including dismentling of reduction gears coupled to electric motor type V-400 gear ratio 1:50 make radicon with replacement of V-belts, gear oil, repair to gear, gear shaft etc complete all as specified and directed. Note :- (i) T&P required for lifting and lowering for clarifloculator tank compartment shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor. (iii) The cost of transportation to workshop and back is deemed to be included in the quoted rate. (iv) T&P required such as Hydra Crane shall be provided by the contractor and rate for the same be included in the quoted rates. (v) Maintenance of 2 year AMC will be providede by contactor rate for the same be included in the quoted rates.

1

-

-

... More
M & L for Repair & maint Electric operated chain pulley block capacity 1 ton alongwith carriage made out of angle iron & MS sheet 4mm thick for placing alum slabs. The chain pulley block should be able to lift the alum from ground level to Ist floor vertically and then horizentally upto alum dozing tank complete all as specified and directed. Note:-The rate quoted by the contractor include dismantling of old chain pully block complete, incl PCC work and cost of necessary cable,Pendent Contol Remote of crane including incoming isolator switch as reqd at site.

1

-

-

... More
Supply, laying,testing and commissioning of GI tubing medium grade ISI Marked with all fittings such as elbow, bends, sockets, nipples,Tee, and union etc complete laid in trenches for the 50 mm bore complete all as specified and directed.

90

-

-

... More
Material and labour for Replacement of heavy duty sluice valve 300mm bore complete with iron wheel conforming to IS 1538,PN 1.6 of double flanged and drilled end provided with high tensile steel spindle including GI flanged Bolts/Nuts/washers gasket etc complete all as specified and directed.

6

-

-

... More
Incoming (a) MCCB 63 Amp 4 pole 36 KA I415 volts AC, Fixed Thermal and Fixed Magnetic with Ics = 100 % og Icu - 01 Nos (b) Alum bus bar 100 Amp TPN - 01 Set (c) Digital voltmeter 0-400 volts with selector switch - 01 No (d) Digital Amp meter 0-400 Amp with selector switch & CT - 01 No (e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 Set Outgoing (a) MCB 3 pole, 32 Amp, 10 KA, 415 volts Fixed Thermal and Fixed Magnetic with Ics = 100 % og Icu - 04 No (b) MCB 3 pole, 25 Amp, 10 KA, 415 volts AC- 1 No (c) DOL Starter for 2 HP Motors ,1.5 KW 415 V 50 HZ,3.5 Amps, cubical MK1/ML0 - 04 No (d) Single phase prevertor (Relay scale 2.5-4.0 Amps), -04 No

-

-

-

... More
M& L for repair to lime mixing system including dismantling of reduction gears coupled to electric motor type V-400 make Radicon with replacement of agitator system, gear oil, scrapping of lime tank preparation of surface and painting the tank with two coats of anticorrosion paint complete all as specified and directed. Note - The rate quoted by Contractor cost of all electrical/mechanical work/materials complete required to make the lime mixing system fully functional.

1

-

-

... More
S&F GI Strip of size 25 x 4 mm for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed

200

-

-

... More
M & L for Dismantling of 3 phase Air Blowers of adequate capacity (not less than 250 cfm) coupled with electric driven AC induction Motor of cap 20 HP three phase including carrying out maintenace check along with following repairs electric motor coupled to taking out old UNSV/burnt winding were carefully including taking out old UNSV bearings, preparing the stator for rewinding with super enamelled copper wire of appropriate guage and thickness with allied insulating material, varnish, heat treatment of reqd, replacement of bearings , replacement of coupling with key and scrapping old paint preparation of surface and painting the motor with synthetic enamel paint of capacity 20 HP. Dismantling of Twin lobe commpressor in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts and assembling the same after filling compressor oil No 320 or as existing, upto indicated level. (b)Heating, varnishing to stator, rotor with super quality varnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Assembling of motor with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load complete..complete all as directed. Note:- Any repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers, Gear oil of compressor etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor shall be measured and paid to be included in the quoted rates

2

-

-

... More
M & L for chlorine testing kit Digital type Complete all as directed by Engr-In-Charge.

2

-

-

... More
S & F Cast Iron fittings such as bends, connection piece, collers straight or tapered etc of any size 200 mm to 300mm dia conforming to IS 14846 / 2000 for spigot and socket pipe/flanged pipe complete all as specified and directed. Note :- The rate quoted by Contractor cost of all fitting and dismentaling work complete required to make the system fully functional.

100

-

-

... More
M & L for iron test kit Digital type Complete all as directed by Engr-In-Charge.

1

-

-

... More
M& L for for opening covers of existing size of clear water sump , filter bed clear water in let point cover and alum mixing chamber by MS Sheet thickness 25x25x4mm thick MS Angle iron frame and 3.0 mm thick MS plate cover with hinges and necessary locking arrangements painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. Note :- The rate quoted by the contractor include necessary Brick and PCC work deemed to be included in the quoted rates.

6

-

-

... More
M& L for repair/ Replacement of RATE OF FLOW/LOSS OF HEAD METER FOR RAPID GRAVITY SAND FILTER PLAN .The instrument is a float operated direct reading meter. The pressure of water beyond the filter outlet valve and the pressure of water above the sand bed are directly transmitted to float chamber where two different floats correspond to the two different levels. The dial and the indicator pointer move in the same direction and the difference between two levels in two float tanks is obtained directly from the gauge calibrated accordingly complete all as specified and directed. Note - The rate quoted by Contractor cost of all electrical/mechanical work/materials complete required to make the system fully functional.

4

-

-

... More
All as per item No 25 above but 100 mm bore pipe complete all as specified and directed.

4

-

-

... More
Supply, installation and commissioning and testing of LT panel cubical type CPRI Approved certified suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed

1

-

-

... More
M&L for Dismantling of old one and supply & fixing new reduction gear for flocculators/pre sedimentation tank type V-400 ratio 1:60 make Radicon with replacement of V-belts, gear oil, repair to gears, gear shaft, repair to rail and wheel of the floculator, alignment complete all as specified and directed. Note :- (i) T&P required for lifting and lowering for clarifloculator tank compartment shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor. (iii) The cost of transportation to workshop and back is deemed to be included in the quoted rate. (iv) T&P required such as Hydra Crane shall be provided by the contractor and rate for the same be included in the quoted rates. (v) Maintenance of 2 year AMC will be providede by contactor rate for the same be included in the quoted rates.

2

-

-

... More
Material and labour for Replacement of Non Return Valve for 150 mm dia including GI flanged Bolts/Nuts/washers gasket etc all complete all as specified and directed

2

-

-

... More
All as per item No 25 above but 150 mm bore pipe complete all as specified and directed.

4

-

-

... More
All as per item No 25 above but 200 mm bore pipe complete all as specified and directed.

6

-

-

... More
Supply and fix Flat three core PVC insulated & PVC sheathed copper unarmoured cable of size 25 Sqmm for Centrigugal motors incl. taking out of old unserviceable cable from existing position complete all as specified and directed.

400

-

-

... More
M & L for Dismantling of 3 phase electric motor coupled to reduction gears, taking out old UNSV/burnt winding were carefully including taking out old UNSV bearings, preparing the stator for rewinding with super enamelled copper wire of appropriate guage and thickness with allied insulating material, varnish, heat treatment of reqd, replacement of bearings , replacement of coupling with key and scrapping old paint preparation of surface and painting the motor with synthetic enamel paint of capacity 3 HP.complete all as directed. Note :- (i) Min. 9 month warranty of motor winding . (ii) The cost of transportation to workshop and back is deemed to be included in the quoted rate. (iii) The rate quoted by Contractor cost of all fitting and fixing complete required to make the system fully functional.

6

-

-

... More
M & L for PH test kit Digital type Complete all as directed by Engr-In-Charge.

2

-

-

... More
Supply, installation and commissioning and testing of LT panel cubical type CPRI Approved certified suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed

1

-

-

... More
Material and labour for Dismantling of 3 phase motor and rewinding of centrifugal motor and pump of any description, dismantling and strip opening of the motor, removing the old existing burnt windings, cleaning the slots and rewinding of the electric motor of 3 phase, 415 Volts, 50 Hz AC supply with existing gauge copper wire including insulating material such as illumines paper, etherized paper, cotton waste, glass sleeves insulating varnish etc, refixing on existing platform and connected all the electric connections and mechanical connections and testing the complete pumping set up to the entire satisfaction of the Engr-in-Charge for Upto 20HP capacity complete all as specified and directed. Note :- (i) Min. 9 month warranty of motor winding . (ii) The cost of transportation to workshop and back is deemed to be included in the quoted rate. (iii) The rate quoted by Contractor cost of all fitting and fixing complete required to make the system fully functional.

2

-

-

... More
Supply, installation and commissioning and testing of LT panel cubical type CPRI Approved certified suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 not less than 60cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and directed

1

-

-

... More
M& L for repair / Replacement of PRESSURE GAUGE WITH ISOLATING VALVE AND SIPHON in pipe line system including dismantling of old complete all as specified and directed. Note - The rate quoted by Contractor cost of all fitting and fixing complete required to make the system fully functional.

4

-

-

... More
M & L for Replacement of bleaching dozing tank with replacement of mechanical stirer and handle system complete, cleaning the tank and making tank leak proof using suitable material incl making the connection of dozing tank with out going water water channel of filter plant with 20mm dia PVC pipe 10 RM laid in floor with PVC stop valve-02 Nos complete all as specified and directed. Note: The rate quoted incl cost of breaking the floor to accomodate the PVC pipe 20mm and making good the floor with PCC etc cleaning and white washing the dozing tank

2

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 40 mm bore pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion. connected to earthing test point complete all as specified & directed. Note : GI strip and protection pipe 40mm bore upto 7.5 RM lenghth included the quoted rate.

10

-

-

... More
M&L for Repair & maint of Removing the MS scraper mechenism from clarifloculator tank compartment by opening nuts & bolts, cutting the welded parts and dismentling the parts (Approx weight 2500 Kgs) and refixing the same after required repair complete all as specified and directed. Note:- (i) T&P required for lifting and lowering for clarifloculator tank compartment shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor. (iii) The cost of transportation to workshop and back is deemed to be included in the quoted rate. (iv) T&P required such as Hydra Crane shall be provided by the contractor and rate for the same be included in the quoted rates. (v) Repair / replacement of parts shall be measured & paid for seperately

3

-

-

... More
M & L Replacement of CENTRAL BEARING ASSEMBLY complete with CI Housing, Shaft, bearing, grouting bolt, Current Collector Box etc.01 No, replacement of carbon brush assembly 01 No, replacement of MS chains 01 Nos, FLOCULATOR DRIVING ARRANGEMENT replacement of floculator/ reddle and shaft complete with Bearing Housing, Coupling, Bevel Gear, Motor, Gear Box, flexible coupling etc.r, CLARRIFIER END CARRIAGE DRIVE ASSEMBLY complete with idle shaft driving wheel, plummer bearing, chain sproket, motor, suitable gear box, Flexible Coupling etc., repair to reduction gear by replacement of gears, Gear shaft for end carriage type U-400 ratio 1:50 make - Redicon.complete all as specified and directed. Note :- (i) T&P required for lifting and lowering for clarifloculator tank compartment shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor. (iii) The cost of transportation to workshop and back is deemed to be included in the quoted rate. (iv) T&P required such as Hydra Crane shall be provided by the contractor and rate for the same be included in the quoted rates. (v) Maintenance of 2 year AMC will be provided by contactor rate for the same be included in the quoted rates.

3

-

-

... More
Incoming (a) MCCB 160 Amp 4 pole 36 KA I415 volts AC, Fixed Thermal and Fixed Magnetic with Ics = 100 % og Icu - 01 Nos (b) Alum bus bar 250 Amp TPN - 01 Set (c) Digital voltmeter 0-400 volts with selector switch - 01 No (d) Digital Amp meter 0-400 Amp with selector switch & CT - 01 No (e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 Set Outgoing (a) MCCB 3 pole, 100 Amp, 36 KA, 415 volts Fixed Thermal and Fixed Magnetic with Ics = 100 % og Icu - 05 No (b) MCCB 3 pole, 63 Amp, 36 KA, 415 volts AC- 02 No (c) Star Delta Starter for 20 HP Motors ,15 KW 415 V 50 HZ,28 Amps, cubical ML-2 - 05 No, (d) Single phase prevertor (Relay scale 20-32 Amps), -05 No

-

-

-

... More
M & L for Replacement of MS scraping arms by dismantling old one and supply & fixing new blades made out of MS Sheet 3.15mm thick and size as per existing sample with SS but bolts and with rubber strip of neoprene rubber to clear the tapered floor of clarifier and fixing blade assembly with revolving arm complete all as specified and directed. Note: (i) T&P required such as Hydra Crane shall be provided by the contractor and rate for the same be included in the quoted rates. (ii) Maintenance of 2 year AMC will be provided by contactor rate for the same be included in the quoted rates.

12

-

-

... More
Supply, laying,testing and commissioning of GI tubing medium grade ISI Marked with all fittings such as elbow, bends, sockets, nipples,Tee, and union etc complete laid in trenches for the 25 mm bore complete all as specified and directed.

30

-

-

... More
Incoming (a) MCCB 160 Amp 4 pole 36 KA I415 volts AC, Fixed Thermal and Fixed Magnetic with Ics = 100 % og Icu - 01 Nos (b) Alum bus bar 250 Amp TPN - 01 Set (c) Digital voltmeter 0-400 volts with selector switch - 01 No (d) Digital Amp meter 0-400 Amp with selector switch & CT - 01 No (e) Indicator lamp LED type (R, Y, B) complete with bakalite fuse fitting - 01 Set Outgoing (a) MCB 3 pole, 32 Amp, 10 KA, 415 volts AC- 10 No (b) MCB 3 pole, 16 Amp, 10 KA, 415 volts AC- 4 No (c) DOL Starter for 3 HP Motors ,2.25 KW 415 V 50 HZ,5 Amps, MK1/MLO- ,10 No (d) Single phase prevertor (Relay scale 4-6.5 Amps), -10 No

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.