Military Engineer Services Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Machinery and Tools
Eprocure
Opening Date3 Mar 2025
Closing Date2 Apr 2025
Tender Amount₹ 69,00,000
Costs
EMD
₹ 1,28,500Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699960_1Tender No
CWE/P-64/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F fibre glass 2mm thick reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc including taking down old sheet, complete all as specified and directed.
452
-
-
... More
Taking down eaves gutters and rain water pipe (any size pattern) including all fittings, heads, shoes bends, swan-necks etc including cleaning and refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories including using ladders on is own arrangement), complete all as specified and directed.
200
-
-
... More
S&F in repair steel rolling shutters, thickness of laths 1.25 mm with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, including taking down old unserviceable shutters complete: push pull or manual type incl two coats of synthetic enamel Paint over a coat of red oxide primer etc complete all as specified and directed.
265
-
-
... More
S&F in repair Ball bearing for rolling shutters, complete all as specified and directed.
12
-
-
... More
M&L for cleaning, breaking, loose concrete, cleaning of reinforcement and filling plain cement concrete 1:1 1/2 :3 type B0 using 12.5mm graded aggregate at places as per direction by Engg-in-Charge (the cost of scafoldings, formworks deemed to be included in the item), complete all as specified and directed.
2
-
-
... More
S&F in rolled mild steel Fe-410-W(Gde-E-250) quality -B roof trusses (framed) trussed,purlins,crane gantries,rails and fastening and heavy bracket framing (Beam,tee,angle,channel or flat sections) including distance pieces cleats etc incl dismantling of structural steel work etc, complete all as specified and directed.
600
-
-
... More
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
20
-
-
... More
S&F PVC(SWR) pipes 110mm bore, single socketd , in any length with rubber ring joints , in any length fixed to walls, complete all as specified and directed.
200
-
-
... More
Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames), complete all as specified and directed.
32
-
-
... More
S&F steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay,complete with glazing bars dovetailed or welded and painting two coats of synthetic enamel paints over one shop coat of zinc chromate primer, complete all as specified and directed.
57.6
-
-
... More
S&F sheet glass selected quality and glazing with oil putty, 3mm thick, in area n.exc 0.5 Sqm in each pane , etc, complete all as specified and directed.
28.8
-
-
... More
S&F sheet glass selected quality and glazing with oil putty, 4mm thick, in area n.exc 0.5 Sqm in each pane , upto 15m height, incl hacking out old broken glass, complete all as specified and directed.
55.8
-
-
... More
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed.
75
-
-
... More
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
3180
-
-
... More
M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
1500
-
-
... More
M&L rendering 05 mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling finished even and fair without using extra cement all as specified and directed.
100
-
-
... More
M&L Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) in two layers (5mm finishing layer over 10mm base layer) finished even and smooth without using extra cement with WPC over finishing layer complete all as specified and directed (Note WPC shall be measured and paid seperately)
1500
-
-
... More
Supply only liquid water proofing compound
16.62
-
-
... More
M&L for rendering or plastering work 10mm thick in CM 1:3 in fascia/ edging/ ceiling of Chajjas, roof projections etc, including taking out peeled off plaster/ concrete and making the line in true shape and finishing the surface without using extra cement.
80
-
-
... More
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of requires shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90 litre/10 sqm over new surfaces etc all as specified and directed.
1500
-
-
... More
M&L Preparing new wall surface including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and applying two coats of acrylic , antifungal emulsion exterior weather proof paint on external surfaces, complete all as specified.
80
-
-
... More
M&L Preparation of new plastered surface of wall by Lime colour wash two coats of colour wash over a coat of white wash of new surfaces complete all as specified and directed
1500
-
-
... More
M&L three coats of white wash on ceiling surface including preparation of new plastered surface, complete all as specified and directed.
100
-
-
... More
M&L for preparation of old surface and applying two coats weather proof exterior emulsion paint, complete all as specified and directed.
1000
-
-
... More
M&L Preparation of old plastered surface of wall by Lime colour wash two coats of colour wash on surfaces complete all as specified and directed
1700
-
-
... More
M&L two coats of white wash on ceiling surface including preparation of Old plastered surface complete all as spd and directed.
70
-
-
... More
M&L for 75mm thick cement concrete type B-2,1:2:4 (40mm graded aggregate ) as in floor finishes or paving complete in alternate bay etc, complete all as specified and directed.
1000
-
-
... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
70
-
-
... More
Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable in and incl rigid PVC conduit concealed medium grade with pressed mild steel terminal boxes(sheet not less than 1.6 mm thick) duly painted with a coat of red oxide primer with suitable thickness plastic laminated sheet cover 3mm thick of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge. Note: a) Rate for cutting chases for conduits and sinking for boxes and making good to wall, floors deemed to be included in each point etc
(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for any necessary pointwith proper fixing clips and no extra cost shall be paid for the job etc all as directed.
45
-
-
... More
All as per item No 32 above but for one 3 pin 5 Amp socket outlet on independent board.
10
-
-
... More
All as per item No 32 above but for one 3 pin 5 Amp socket outlet on same board.
5
-
-
... More
Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes(sheet not less than 1.6mm thick) of adequate size with suitable thickness plastic laminated sheet cover 3mm thick for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, complete all as specified.
10
-
-
... More
S&F switch piano flush button single pole one way 5 amps 230 volts,complete all as specified and directed by Engr-in-Charge.
60
-
-
... More
S&F socket outlet 5 amps 5 pin flush type, 230 volts, complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
S&F switch piano flush button single pole one way 15 amps 230 Volts, complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F socket out let, 6 pin, 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts, complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F ceiling rose surface bakelite two to three terminal isolated body fixed on PVC round block complete all as specified.
15
-
-
... More
S&F LED high way light fitting 150 watt, 230v, including SPD with polycarbonate diffuser complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size. complete all as specified.
28
-
-
... More
S&F in replacement of 100 watt LED 6000K energy saving, enviromental friendly, long life, exclusive innovative die- cast aluminium IP 65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces complete all as specified and directed by engineer-in-charge.
13
-
-
... More
S&F in replacement sheet metal powder coated VTPN DB double door 4 way with MCCB 100 amps, 415 Volts, 50 Hz AC 16 KA 4 pole with copper bus bar rated 200 amps neutral link, earth bar and din rail for fixing the MCB,s complete all as specified . Note :-MCCB Shall be measured and paid seperately in relevant item.
3
-
-
... More
S&F in replacement MCCB four pole 100 Amps with 16 KA breaking capacity adjustable thermal & fixed magnetic in distribution boards all as specified and directed.
3
-
-
... More
S&F in replacement sheet metal powder enclosure powder coated versatile double door 8 way (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutral link , earth bar complete all as specified.
4
-
-
... More
S&F MCBs single pole and neutral (SPN) 40 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified and directed.
4
-
-
... More
S&F in replacement MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified.
40
-
-
... More
S&F in Replacement of sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 2.5 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 2.5 Sqmm as a earth continuity conductor(green colour) in and including existing conduit complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 1.5 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 1.5 sqmm copper conductor cable (FRLS) as an earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
250
-
-
... More
S&F in Replacement of sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor(green colour) in and including existing conduit complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS) as an earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
106
-
-
... More
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. Note - 1.Earth Returning filling should be with vegitable soil only free from stones and gravels 2. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in the unit rate quoted.
3. Earth filling shall be done by vegitable soil.
4. Soil shall be free from stone, boulders, aggregate, gravels etc. 5.On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
8
-
-
... More
S&F wall mounting fan heavy duty 450 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
16
-
-
... More
Supply, installation, testing and commissioning of Minimum 8.5 TR capacity Air cooled packaged Air conditioners comprrising of Hermetic/Semi - Hermetically sealed Reciprocating or Hermetically sealed scroll compressors with Microprocessor based control, including copper refrigerant piping,electrical interconnection between indoor and outdoor units , suitable for operation on 410a refrigerants complete all as specified and directed by Engr-in- charge. Note:- Design, supply, installation, testing and commissioning of Package AC plant with the following parmeters under specification complete mention in ser item No. 52 to 67 here in after all as specified and directed.( Temperature maintain 22º C± 2º C and humidity 55%± 5%).
1
-
-
... More
M&L for lifting, shifting of indoor and out door unit of AC
1
-
-
... More
Installation testing & commissioning of ductable package type air- conditioning system Ductable package unit of cap 8.5 TR to be installed from unit to required location complete all as specified and directed by Engr-in- charge
1
-
-
... More
Supply, installation, inter connecting refrigerant pipe work of indoor & outdoor units as per specifications, all piping in side the rooms hall be properly supported with MS hanger for ductable package AC of size19.1 mm & 12.7 MM complete all as specified and directed.
30
-
-
... More
S&F GI Perforated cable tray 16G in a size(150x40mm with necessary hardware & rubbergasket & clamps for copper piping & v cable etc as reqd complete all as specified and directed by Engr-in- charge.
30
-
-
... More
Supply & laying drain piping Rigid PVC piping 25 mm dia complete with fittings, support sasper specifications and duly insulated with 6mm thick closed cell, complete all as specified and directed.
10
-
-
... More
S&F control cum transmission wiring of 3 core x 1.5 sqmm copper insuitable conduits between indoor and out door unit.complete all as specified and directed.
35
-
-
... More
Supply, Installation, testing & commissioning of sheet metal leak proof ducting of size 24 gauge complete with necessary angle /channel supports, hangers ,nuts, bolts, anchor astners, washers, rubber gaskets etc., GI body heavy guage manual volume control dampers, vanes, etc. as per specifications and drawings. All ducting of any size should be flanged type and no slip joints will be allowed .All joints, corners of the ducting to be applied with silicon seal and for leak proof joints.Cost of smoke testing of the ducting as per specification/site instruction is to be included complete all as specified and directed.
50
-
-
... More
M&L for duct insulation Closed cell, Fire retardant, class 'O' insulation of 13 mm thick complete all as specified and directed by Engr-in- charge
60
-
-
... More
M&L Aucostic insulation Open cell, Fire retardant, class 'O' insulation of 15 mm thickcomplete all as specified and directed by Engr-in- charge
5
-
-
... More
Supply,installation,testing and commissioning supply and return air grilles /diffusers as per specifications and drawings including fixing frame of G.I./wooden in false ceiling/walls.Aluminium supply /return air grill without damper complete all as specified and directed by Engr-in- charge
3
-
-
... More
Supply, installation, testing and commissioning of fire retardant non porous double layer flexible connection between each duct type indoor unit and ducting complete all as specified and directed by Engr-in- charge
1
-
-
... More
S&F MS outdoor unit stand as per manufacturer design and specification complete all as specified and directed by Engr-in- charge
1
-
-
... More
Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type, platform mounted suitable for 3phase 4 wire, 50 Hz, AC supply system base bus bar chamber with insulated busbar 200 amps (3 Nos) phase and 100 amps for neutral rating installed on porcelain insulator. The panel shall be dust and vermin proof IP 65 class protection and made out of 2 mm thick CRCA MS sheet and 40 mm x 40 mm x 6 mm thick angle iron frame works, powder coated finish over one coat of red oxide primer outside two coats of red oxide primer inside, front opening type with approns for cable ending with double door shutter and locking arrangement (Including provn of 65 mm Godrej (freedom) lock with 2 keys, insulated copper conductor FRLS IS-699 marked 1100 volt grade but seathed cable adequate size but not less than 4 mm size including incomming MCCB -1 No and out going MCCB -2 Nos (suitable capacity of MCCB for 8.5 TR Package AC ) including Digital Volt meter and ammeter with selector switch Digital Ammeter ratio type 0 to 100 amps with 3 way CTs 100/5 with selector switch - 01 No and RYB LED Indicator lamp- 03 Nos including suitable size starter /contactor as desired capacity by manufacturer etc complete all as specified and directed.
1
-
-
... More
Supply, installation, commissioning & testing of motorized combination fire and smoke damper (spring return type) of atleast 120 minute fire rating and all as specified. The fire damper shall be complete with electronic temperature sensor, electrically operated actuator, control panel & wiring.The fire dampers shall be located in the supply/return air ducts, at all fire rated crossovers (shafts/walls etc.) The control panel will be such located that the reset can be easily done, including Electrical spring type actuator,remote indication of the fire damper position complete all as specified and directed by Engr-in- charge.
1
-
-
... More
M&L for civil work like Masonry foundation for package AC plant indoor and outdoor unit electric panel, and AHU shall be as per manufacturer’s instruction/recommendation and making opening in brick wall/other type of walls and making good for ducts, pipes cable and fresh air intake- 01 Job.
(ii) Removing carefully false ceiling for dismantling AC duct and refixing after installation or new AC ducts including making good to damaged false ceiling all as directed- 01 Job.
1
-
-
... More
Repair & Maintenance of electric operated crane of cap 2.0 Ton and making fully functioning by rectify any type of defects including servicing, gressing, top up gear box oil & carrying out routine maintenance before and after repair the functional, testing/checking of long travell motion, cross travel motion, hoisting motion (electrically and mechnically) to be done in the presence of user and MES rep.as directed by engineer-in-charge.
Note :- (i) any accessories found unserviceable that shall be replaced under respective items of this Sch. (ii) Labour for lowering, mounting arrangement such as ladder , pulley block, rope system, T&P , any type nut, bolt, washers and other connected mechanism shall be contractor arrangement and rates are deemed to be included in this Job. No extra payment will be made to the contract against lowering/lifting the spare etc at a height of 20' to 30'.
2
-
-
... More
Dismantling the main driving shaft of forward/reverse drive of EOT crane after unscrewing nuts, bolts, washers including other connected accessories with shaft such as braking assembly, coupling, bearings rings, gear box lowering down the smaller portion of shaft from up to 30' approximate height for removing and threading, repairing manufacturing cutting teeth keys one Nos bearing housing cabinet and replacement of one Nos tapper bearing welding of foundation rest pad making drills holes in rest pads matching with main foundation of trolly, cleaning, greasing and oiling of all the bearing, bearing housing, gear box etc complete for smooth functioning including providing nut, bolts with locking arrangement & washers of any type/ size as site requirement complete including re-assembly with connected accessories after repair including carrying out necessary alignment of all the parts connected with shaft all as specified and directed by Engineer-in-charge (Capacity of crane - 2.0 Ton )
2
-
-
... More
Dismantling/strip opening gear of micro main shaft drive for replacement of 2 Nos gun metal bushes having internal lining for oiling arrangement, replacement of all the nuts/bolts of bush side plate with L-key, bolts of size as per sample oiling/greasing of gear box including necessary cast iron repair to broken foundation which includes welding lathing and grinding complete all as specified and directed. (Crane capacity 2.0 Ton )
2
-
-
... More
Dismantling/strip opening micro drive box complete with rectifier transformer arrangement, magnetic disc both side coupling for remotting both the side ends of driving shaft (Gear box coupling side and braking arrangement coupling side) making multi key arrangement on both the shaft and couplings (teeth system ) to avoid any kind of play in coupling and shaft including replacement of 4 Nos carbon bushes, replacement of 02 Nos gun metal bushes including making oiling arrangement in bushes and side covers of bushes/housing of micro drive re-assembling/testing complete (crane capacity 2.0 Ton) all as specified and directed.
2
-
-
... More
Dismantling/strip opening of up/down micro electric braking arrangement after un-screwing nuts, bolts washers, re-adjustment of braking springs, replacement of brake leathers, replacement of two Nos 440 volts any make brake coils, replacement of both gun metal bushes of shaft housing in brake box making oiling/ greasing arrangement complete re-assembling and testing complete all as specified and directed.(Crane capacity 2.0 Ton )
4
-
-
... More
M&L for replacement coupling as per sample or approved by GE suitable for perfect alignment between flameproof motor and driven machine all as directed.
6
-
-
... More
M&L for replacement of L Key bolts 1" x 10mm as per sample or approved by GE including applying moose threads found worn out and taking out broken bolts from body/housing of machine for 2.0 Ton capacity flameproof EOT Crane complete all as specified and directed.
60
-
-
... More
Dismantling/ lowering of burnt weather proof three phase 440 volts, 50 Hz, 960 RPM, class F, 5 HP induction motor from platform complete including strip opening the same and rewinding with super enameled copper winding wire of same size /gauge as existing earlier complete including all backing material , insulation material and re- installation the same at original site complete all as specified and directed.
6
-
-
... More
M&L for of Power contactor 3 pole 16 Amp , 110 Volt as per sample or approved by GE complete all as specified and directed.
4
-
-
... More
M&L for of Power contactor 3 pole 40 Amp , 110 Volt as per sample or approved by GE complete all as specified and directed.
4
-
-
... More
M&L for of Over load relay 1.7 to 2.4 Amp as per sample or approved by GE complete all as specified and directed.
4
-
-
... More
M&L for of main bearing as per site requirment suitable for 2 Ton cap crane all as specified and directed.
4
-
-
... More
M&L for brake oil suitable for EOT crane up to 2 Ton cap as per manufacture recommendation or directed.
100
-
-
... More
M&L for grease suitable for EOT crane up to 2 Ton cap as per manufacture recommendation or directed.
80
-
-
... More
Replacement of old UNSV 4 Nos Bare copper conductor of size 5 SWG (standard wire gauge ) as Long as travel with the latest. Colour coded RYBG,finger surge design down shop lead of shrouded Bus Bar system for the LT motion complete with current collectors of copper graphite and MS supports brackets, complete all as specified and directed.
150
-
-
... More
S&F suitable size Access ladder of 450-mm width and suitable length at one on each out of the bay, of 65X 65X 6mm for side section and 40mm Square/ Rectangular pipe for rings/steps, complete all as specified and directed.
4
-
-
... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of pipe, cable, foundation of electric pole etc and getting out in any type of soil, complete all as specified and directed.
27
-
-
... More
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
24.3
-
-
... More
Removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
2.7
-
-
... More
Sand cushioning for underground cable 8cm before laying the cable and 15cm after laying and stretching the cable complete all as specified and as directed. (Note:- Punned thickness of 18cm shall be considered for measurement purpose).
8
-
-
... More
M& L Brick tiles; common burnt clay building bricks sub-class ‘B’ Designation 75 for laying of underground cable, complete all as specified and directed.
880
-
-
... More
M&L for tubes 'light grade' galvanised with all fittins laid in trenches/fixing on pole/panel/road /drain etc for cable protection of size 50 mm bore, complete all as specified and directed.
20
-
-
... More
Supply and laying in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 16 sq mm X 4 core stranded conductor, complete all as specified and directed.
150
-
-
... More
Supply and laying in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 35 sq mm X 3.5 core stranded conductor, complete all as specified and directed.
100
-
-
... More
Supply, installing, testing and commissioning factory made and tested LT Panel out door type, platform mounted suitable for 3phase 4 wire, 50 Hz, AC supply system base bus bar chamber with insulated busbar 400 amps (3 Nos) phase and 200 amps for neutral rating installed on porcelain insulator. The panel shall be dust and vermin proof IP 65 class protection and made out of 3.15 mm thick CRCA MS sheet and 40 mm x 40 mm x 6 mm thick angle iron frame works, powder coated finish over one coat of red oxide primer outside two coats of red oxide prmer inside, front opening type with approns for cable ending with double door shutter and locking arrangement (Including provn of 65 mm Godrej (freedom) lock with 2 keys, insulated copper conductor FRLS IS-699 marked 1100 volt grade but seathed cable adequate size but not less than 4 mm size complete all as specified and directed by engineer - in - charge. (a) MCCB 250 Amps, 4 Pole, 415 Volts 36 KA - 01 Nos (Incoming) (b) MCCB 63 Amps TP 16 KA 415 Volts 25 KA-05 Nos (Outgoing) (c) On load Changeover FP 63 amps -1 No (d) RYB LED Indicator lamp- 03 Nos (e) Digital Ammeter ratio type 2 to 200 amps with 3 way CTs 200/5 with selector switch - 01 No (f) Digital Volt meter and ammeter with selector switch 0-500 Volts - 01 No
1
-
-
... More
M&L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
2
-
-
... More
Notes: The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%