Military Engineer Services Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Machinery and Tools
Eprocure
Opening Date21 Nov 2024
Closing Soon5 Dec 2024
Tender Amount₹ 45,58,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of cross arms of MS channel or angle sections etc complete all as specified and as directed.

1

-

-

... More
Dismantling LT OH line from the insulators complete all as specified and directed.

3

-

-

... More
Dismantling and taking down the existing LT insulators of any type from any description, complete all as specified and as directed.

48

-

-

... More
Dismantling & Taking out the existing old service cables off sizes, complete all as specified and as directed.

2000

-

-

... More
Dismantling old UNSV existing LT panel with switch gears, complete all as specified and as directed.

1

-

-

... More
Dismantling & Taking out old UNSV earthing, complete all as specified and as directed.

2

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core, complete all as specified and as directed.

300

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core, complete all as specified and as directed.

260

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified and as directed.

350

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core, complete all as specified and as directed.

330

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core, complete all as specified and as directed.

400

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as specified and as directed.

50

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 2 core, complete all as specified and as directed.

540

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete all as specified and as directed.

3000

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified and as directed.

600

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core, complete all as specified and as directed.

200

-

-

... More
S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :-

-

-

-

... More
(a) 50 mm dia

24

-

-

... More
(b) 80 mm dia

24

-

-

... More
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Mandir) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 650 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-

1

-

-

... More
(a) INCOMING

-

-

-

... More
(i) MCCB 4 Pole 415 volts grade 400 Amps rating and 36 KA rupturing capacity - 01 No

-

-

-

... More
(ii) Voltmeter Digital Type 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No

-

-

-

... More
(iii) Ammeter Digital type size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No

-

-

-

... More
(iv) CTs ratio 400/5A class ISI marked sets of three each

-

-

-

... More
(v) Indicating lamp-01 set of three

-

-

-

... More
(b) OUTGOING

-

-

-

... More
(i) MCCB 4 Pole, 415 volts grade 320 Amps rating and 25 KA rupturing capacity -01 Nos

-

-

-

... More
(ii) MCCB 4 Pole, 415 volts grade 160 Amps rating and 25 KA rupturing capacity -02 Nos

-

-

-

... More
(iii) MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity -02 Nos

-

-

-

... More
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH front side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-

1

-

-

... More
(a) INCOMING

-

-

-

... More
(i) MCCB 4 Pole 415 volts grade 320 Amps rating and 25 KA rupturing capacity - 01 No

-

-

-

... More
(ii) Voltmeter Digital Type 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No

-

-

-

... More
(iii) Ammeter Digital type size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No

-

-

-

... More
(iv) CTs ratio 100/5A class ISI marked sets of three each

-

-

-

... More
(v) Indicating lamp-01 set of three

-

-

-

... More
(b) OUTGOING

-

-

-

... More
(i) MCCB 4 Pole, 415 volts grade 200 Amps rating and 25 KA rupturing capacity -01 Nos

-

-

-

... More
(ii) MCCB 4 Pole, 415 volts grade 100 Amps rating and 25 KA rupturing capacity -04 Nos

-

-

-

... More
(iii) MCCB 4 Pole, 415 volts grade 63 Amps rating and 25 KA rupturing capacity -02 Nos( spare )

-

-

-

... More
(iv) On load change over switch 415 volts ,50 Hz, 200 Amps capacity complete . -01

-

-

-

... More
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (PH Back side) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-

1

-

-

... More
(a) INCOMING

-

-

-

... More
(i) MCCB 4 Pole 415 volts grade 200 Amps rating and 25 KA rupturing capacity - 01 No

-

-

-

... More
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No

-

-

-

... More
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No

-

-

-

... More
(iv) CTs ratio 160/5A class ISI marked sets of three each

-

-

-

... More
(v) Indicating lamp-01 set of three

-

-

-

... More
(b) OUTGOING

-

-

-

... More
(i) MCB DP 10 TO 32 AMP - 19 Nos

-

-

-

... More
(i) MCB DP 63 AMP - 02 Nos

-

-

-

... More
Supply, Installing & testing and commissioning factory made and tested (incl CPRI type test certified) LT panel board (Adm Block) out door type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated copper bus bar 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof. IP 65 class protection and made of 3.15mm CRCA MS sheet and 50 x 50 x 6 mm thick angle iron frame work, powder coated finish over one coat of red oxide primer out side and two coats of red oxide primer inside, front opening type with aprons for cable entry with double door shutter and locking arrangement (including provn of 65mm Godrej Freedom) lock with 2 keys, internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked of adequate size but not less than 4 Sqmm. The scope of work includes the following :-

3

-

-

... More
(a) INCOMING

-

-

-

... More
(i) MCCB 4 Pole 415 volts grade 100 Amps rating and 25 KA rupturing capacity - 01 No

-

-

-

... More
(ii) Voltmeter 0-500 volts, Square 96 mm, flnsh pattern with 3 way rotary selector switch-01 No

-

-

-

... More
(iii) Ammeter size 96 mm, square dial flush pattern having dual range 0-600 Amps with three way rotary selector switch -01 No

-

-

-

... More
(iv) CTs ratio 160/5A class ISI marked sets of three each

-

-

-

... More
(v) Indicating lamp-01 set of three

-

-

-

... More
(b) OUTGOING

-

-

-

... More
(i) MCB DP 10 TO 32 AMP - 15 Nos

-

-

-

... More
(ii) MCB DP 40 AMP - 2 Nos

-

-

-

... More
S&F loopin loopout fuse junction box of made out of thermo plastic Polycarbonate with IP 66/67 weather proof for outdoor installation (with knockouts of cable entry) protection with terminals and locking screw fitted with 3 phase with neutral copper Bus Bar 400 Amps , 415 Volts, 50Hz and 32 A MCB SPN, suitable for cables off sizes and fixing on wall/surface with the help of clamps two nos of F1 20 x 3 mm and suitable nuts and bolts, complete all as specified and as directed.

6

-

-

... More
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick buried directly in to the ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth strip 32 x 6 mm by means of bolts, nuts thimble check nuts and washers of galvanised iron or steel using GI including PCC (concrete chamber) 1:3:6 Type C-1 using 20 mm graded stone aggregate with fair finish of internal surface concrete, 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68 mm) 8 mesh per inner inch, 80mm thick RCC Pit cover 320mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM and charcole dust and common salt all as shown in electrical plate No-3 MES SSR Part-I and specified including provision of earth wire/ strip protected by 40 mm dia medium grade GI pipe including all excavation and earth work & connecting the earth earthing to an earthing test point/ transformer neutral/ body LT panel etc and testing on complete, complete all as specified and directed Note :- Quoted rate of earthing shall be deemed to included cost of 7.5 M long galvanised iron strip 32X6 mm and protection pipe of 40mm bore medium grade, GI light grade 20mm bore watering pipe.

8

-

-

... More
Supply and fixing RCC cable route marker for LT, complete all as specified and as directed.

100

-

-

... More
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth,for foundations,laying of pipes etc not exceeding 10sqm on plan for mamholes etc and not exceeding 1.5 metre in depth and getting out in Soft/loose soil, complete all as specified and directed.

750

-

-

... More
Supply and laying of burnt clay building bricks, sub-classB (old size) Designnation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and directed.

15

-

-

... More
M & L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 Note:-Sand shall be fine sand as specified for plastering.

100

-

-

... More
S&F PVC heavy duty conduit pipe 25 mm including connecting fittings complete all as specified and directed.

200

-

-

... More
Removing excavated material of any type of soil/soft rock from site to a distance not exceeding 50mtr away and depositing where directed not exceeding 1.5mtr above the starting point complete all as specified and directed.

430

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil all as specified.

320

-

-

... More
Taking up or down old unserviceable GI/MS tubing and connetions including all fittings from the trenches,wall,floor etc complete all as specified and directed.

-

-

-

... More
(a) 20 mm bore size

200

-

-

... More
(b) 25 mm bore size

150

-

-

... More
(d) 40 mm bore size to 50 mm bore size

500

-

-

... More
(e) 80 mm bore size

50

-

-

... More
(f) 100 mm bore size

45

-

-

... More
(g)150 mm bore size

45

-

-

... More
Taking out sluice valves refacing, regrinding and refixing complete all as specified and directed.

-

-

-

... More
(a) 80 mm bore size

2

-

-

... More
(b) 100 mm bore size

2

-

-

... More
Supply only DI specials fittings such as bends (any type, radius and angle), tapers any type (straight, bends, increasing, decreasing or double socket etc.), tee pieces, single branch, Y junction, double branch, cross (all sockets or spigot & socket), collars, caps and plugs & flanges conforming to IS: 9523/2000 with inside cement mortar lining and outside zinc followed by Black Bitumen coating for DI pipes upto 200 mm bore, complete all as specified and directed.

20

-

-

... More
Supply, laying of GI tubes 'medium grade', ISI marked with and including all tube fitings ( flanges , union, tee, bend reducer etc.) laid in trenches complete all as specified. (a) size 150 mm bore

150

-

-

... More
(b) size 100 mm bore

180

-

-

... More
(c) size 80 mm bore

50

-

-

... More
(d) size 50 mm bore

300

-

-

... More
(e) size 40 mm bore

200

-

-

... More
(f) size 25 mm bore

150

-

-

... More
(g) Size 20 mm bore

200

-

-

... More
S&F cast iron body Foot valve for pipe bore 100 mm, ISI marked with IS 4038 with neoprene rubber gasket joint and nuts bolts (high tensile) washers etc complete including testing all as specified.

2

-

-

... More
S&F cast iron body Foot valve for pipe bore 150 mm, ISI marked with IS 4038 with neoprene rubber gasket joint and nuts bolts (high tensile) washers etc complete including testing all as specified.

1

-

-

... More
S&F Non return (reflux) valve of size 100 mm bore, PN 1.6, cast iron body, ISI marked, as per IS 5312 part-I, heavy duty, gunmetal seat, flanged ends and drilled, including nuts, bolts, washers and gasket etc, complete all as specified and as directed.

2

-

-

... More
S&F Non return (reflux) valve of size 150 mm bore, PN 1.6, cast iron body, ISI marked, as per IS 5312 part-I, heavy duty, gunmetal seat, flanged ends and drilled, including nuts, bolts, washers and gasket etc complete all as specified and as directed.

2

-

-

... More
S&F Sluice valve of size 100 mm bore, PN 1.6, cast iron body, ISI marked, as per IS 5312 part-I, heavy duty, gunmetal seat, flanged ends and drilled, including nuts, bolts, washers and gasket etc complete all as specified and as directed.

2

-

-

... More
S&F Sluice valve of size 150 mm bore, PN 1.6, cast iron body, ISI marked, as per IS 5312 part-I, heavy duty, gunmetal seat, flanged ends and drilled, including nuts, bolts, washers and gasket etc complete all as specified and as directed.

2

-

-

... More
M&L for Construction of brick masonry valve pit of internal size 110cm x 110cm x 90cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock , complete . Note :-(i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B-1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Two coats of white wash to internal surfaces of valve pit. (vi) Depth of wall pit shall be reckoned from the top of PCC in foundation.

2

-

-

... More
M&L for construction of brick masonry valve pit of internal size 150cm x 150cm x 110cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock, complete all as specified and directed by Engr-in- Charge Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B-1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Two coats of white wash to internal surfaces of valve pit. (vi) Depth of wall pit shall be reckoned from the top of PCC in foundation.

2

-

-

... More
M&L for earthing complete with copper earth plate electrode 60cm×60cm×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip 20x3 mm means of bolts, nuts, check nuts and washers of brass/copper all as shown in electrical plate No. 3 connected to earthing test point and including one test point all as specified or indicated including testing on completion.

6

-

-

... More
M&L for water connection by cutting existing CI/DI pipe line of 150 mm and inserting DI /GI fittings, collar / tail piece, Tee reducer flanged type including any addition/ alteration required for connection and including required earth work, excavation, returning filling, spreading/ leveling complete . Note: Rate includes the DI Tee fittings and any other material required for connection.

2

-

-

... More
S&F cast iron Air valve with two air outlets of size 100 mm dia bore and fixing up in DI maines including all fittings :-

3

-

-

... More
Material and labour for fixing Gun metal, globe or gate valve with iron wheel head, Screwed both end for iron pipe conform to IS 778-1984 complete all as specified and of the following sizes :-

-

-

-

... More
(a) 25 mm dia

20

-

-

... More
(b) 20 mm dia

20

-

-

... More
(c) 40 mm dia

5

-

-

... More
(d) 50 mm dia

5

-

-

... More
Lagging to pipes used in internal water supply or plumbing all around 25 mm thick bended mineral weel preformed "SNAPON" pipe section of density 144 Kg/sqmm on confirming to IS-9042 of 50 mm dia, provided with chicken mesh wire netting 25 gauge, 20mm mesh and with 0.01mm aluminium foil complete all as specified and as directed.

40

-

-

... More
Lagging to pipes used in inernal water supply or plumbing all around 25 mm thick bended mineral weel preformed "SNAPON" pipe section of density 144 Kg/sqmm on confirming to IS-9042 of 40 mm dia provided with chicken mesh wire netting 25 gauge, 20mm mesh and with 0.01mm aluminium foil complete all as specified and as directed.

40

-

-

... More
Lagging to pipes used in internal water supply or plumbing all around 25 mm thick bended mineral weel preformed "SNAPON" pipe section of density 144 Kg/sqmm on confirming to IS-9042 of 25 mm dia provided with chicken mesh wire netting 25 gauge, 20mm mesh and with 0.01mm aluminium foil complete all as specified and as directed.

60

-

-

... More
Lagging to pipes used in internal water supply or plumbing all around 25 mm thick bended mineral weel preformed "SNAPON" pipe section of density 144 Kg/sqmm on confirming to IS-9042 of 20 mm dia provided with chicken mesh wire netting 25 gauge, 20mm mesh and with 0.01mm aluminium foil complete all as specified and as directed.

60

-

-

... More
Supply installation testing and commissioning Pumping sets,40 HP 50 Hzs centrifugal, electric driven suitable for 100 mtr head including fully automatic starter neccessary fittings , foot valve cables , and necceaasry PCC foundation complete all as specified as directed.

2

-

-

... More
Note:- Schedule of credit Rs 74,647.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.