Jammu And Kashmir Cable Car Corporation Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Jammu And Kashmir Cable Car Corporation - JKCCC Tender
Electrical Generators And Transformers
Eprocure
Opening Date6 Mar 2020
Closing Date24 Mar 2020
Tender Amount₹ 28,00,000
Costs
EMD
₹ 56,000Document Cost
₹ 1,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_JKSCC_94525_1Bid Award Id
ViewTender No
ENIT NO 03 of 2020Tender Authority
Jammu And Kashmir Cable Car Corporation ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply Installation Testing and Commissioning of 62.5 KVA (50 KW) DG Set at Tral Shikargah.
BOQ Items
... More
P/I of earthing station comprising of company fabricated earthing electrode copper to copper as per IS 3043. The job includes auguring of bore of reqd. dia / depth for instt. of electrode along with back fill compound mixed with soil and all other items reqd. thereof for achieving the best result.
Safe earth electrode size 80mm dia. Length-3.5 mtr Back fill compound-60 Kg
Model/ make- JVM-398, Ashlok, Recons / Equivalent
4
-
-
... More
S/L and commissioning of PVC aluminium un-armoured cable 1100 volt grade of havell/ Eq.standard make including the cost of trench work excavation hard soil for cable trench, 2 ft deep with an average breadth of 1 ft incl. refilling of trench with excavated earth after laying of cable and ramming it properly incl. sand cushioning . The job also includes necessary road cuts and cement work for laying of cable and making the surface good as before.
-
-
-
... More
a. 120 Sq mm 3.5 Core
860
-
-
... More
b. 70 sqmm 3.5 core
860
-
-
... More
c. 35 sqmm 3.5 core
525
-
-
... More
d. 16 sqmm 2 core
1090
-
-
... More
Supply, installation, testing and commissioning of pre-approved duly painted front and rear operated double door Cubical panel wall/ floor mounting ,with front access made 2mm thick pressed sheet steel enclosure standing dust and vermin proof paint with hinged gasketed and lockable doors complete with interconnections. All live accessible shall be shrouded and all equipment shall be finger touch proof, complete set of phase to phase indicators, 1-No Voltmeter and 1-No Ammeter complete with 1 sets of CT coils and selector switch and 4 strip buss-bar 400 A covered with heat shrinkable colour coaded sleeves and mounted on DMC bus bar supports,, also the panel shall have rear doors for cable terminations. The panel shall be suitable for installation of following accessories:1)250 AmpMCCB 4 pole 1No 2) 160 AmpMCCB 4 pole Amp.3) 100 AmpMCCB 4 pole Havell make/ L&T. The job also includes all mechanical carriage, loading unloading, dragging to the site.
1
-
-
... More
Supply installation testing and commissioning 160 Amp MCCB of Havell /L&T / ABB/ eq. standard make. With 35 KA breaking capacity, having thermal over load and magnetic short circuit protection in existing main panel.
2
-
-
... More
Supply installation testing and commissioning 100 Amp MCCB TPN of Havell/ ABB/ legrand /eq. standard make.
1
-
-
... More
Supply, installation, testing and commissioning of pre-approved duly painted front and rear operated double door Cubical panel of suitable size with for outdoor mounting having angle iron stand to be grouted by drilling bolts in the floor, with front access made 2mm thick pressed sheet steel enclosure standing dust and vermin proof paint with hinged gasketted and lockable doors complete with interconnections. All live accessible shall be shrouded and all equipment shall be finger touch proof, complete set of phase to phase indicators, 1-No Voltmeter and 1-No Ammeter complete with 1 sets of CT coils and selector switch and 4 strip buss-bar 100 A covered with heat shrinkable colour coaded sleeves and mounted on DMC bus bar supports,, also the panel shall have rear doors for cable terminations with following accessories:1)40 Amp. TPN MCB 9 No. Havell make. The job also includes all mechanical carriage, loading unloading, dragging to the site.
3
-
-
... More
Construction of Generator shed for housing of generator with flowing specification. Overall size of shed 12’x16’
a. Foundation of 2ft depth
b. Laying of PCC 1:4:8
c. Laying of RCC raft in M-20 concrete with nominal reinforcement -6’’ thick
d. Plinth upto 2ft height from the ground level
e. Super structure in 9 inch brick wall upto height of 10ft with plaster on the both sides.
f. Chowkats in devdar timber including shutters in kail wood at appropriates spacing
g. Truss work in angel iron inbuilt trusses to cater to snow load of 6ft as per the design including covering of top surface with coated G1 sheets of 0.63mm thickness.
h. Ceiling to be provided in 12mm thick ply board including painting.
i. The structure to be painted as per the approved shade.
j. One side to be provided with roiling shutter of 6ft width.
k. Partition wall to be created inside shed for operator
l. Ramp to be created on one side (shutter side)