Islamic University Of Science And Technology Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Islamic University Of Science And Technology - IUST Tender
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date20 Feb 2024
Closing Date27 Feb 2024
Tender Amount₹ 22,68,780
Costs
EMD
₹ 45,376Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IUST_245394_1Bid Award Id
ViewTender No
IUST/EW/24/TEND/ELE/LTPCMB/03Tender Authority
Islamic University Of Science And Technology ViewPurchaser Address
-Website
http://https://www.iustlive.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1 Set of 600 Amps 4P, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar. (Busbar-I)
-
-
-
... More
1 Set of 400 Amps 4P, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Busbar-II)
-
-
-
... More
3 No's of 320A 4P, MCCB Adjustable thermal and fixed magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
2 No's of 250A 4P, MCCB Adjustable thermal and fixed magnetic release of fault breaking capacity 25KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
5 No's of 200A 4P, MCCB Adjustable thermal and fixed magnetic release of fault breaking capacity 25KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
1 No of 320A Onload Changeover.
-
-
-
... More
METERING & INDICATION:
(a). 2 No. of Dgital Multifunction Meter Three Phase Class 1.0 Elmeasure Make.
(b).12 sets of Phase Indication lamps (R,Y,B) 22.5mm 220 Vac.including connection through PVC try, complete in all respects.
(c). 10 No's of Digital Voltmeter, Ammeter.
(d). CT 's and other panel accessories as required for measuring purposes.
-
-
-
... More
Design, Fabrication, Assembling of Supply, Installation, Testing and Commissioning of LT Floor Power Panel (Type -I) from high quality 2mm wall thickness CRCA sheet angle/flat iron mounted with hinged lockable front double door for each meter compartment to accomadate with fixing arrangement of Multi function meter (MFM), MCCB, other switchgears with bus bar ways in separate compartments painted with powder coated conforming to CPWD specification IP-55 .The LT Distribution panel must be free standing with 600mm height from floor ,floor mounting and front execution type suitable for 415 V +/- 3% , 3 phase and neutral ,50 Hz system conforming I.E rules with necessary provision to connect cables of various sizes from the rear bottom side., 50 Hz, 4 wire power supply system.The assembly comprising of chassis ,famework, and fixed parts of metal casing of the switchgear shallbe provided with separte earthing. terminal.The formation must be compartmentalised in form 3b construction and must be supplied and installed. The Panel is comprising of the following items: (S.No. 2.01 - S.No. 2.07)
2
500000
250000
... More
1 No. of 320A 4P, MCCB Adjustable Thermal & Adjustable magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Incommer-I).
-
-
-
... More
1 No. of 200A 4P, MCCB Adjustable Thermal & Adjustable magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Incommer-II).
-
-
-
... More
1 Set of 350 Amps 4P, 36kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Busbar-I)
-
-
-
... More
1 Set of 250 Amps 4P, 36kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Busbar-II)
-
-
-
... More
9 No's of 100A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
5 No's of 63A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
2 Sets of Dgital Multifunction Meter Three Phase Class 1.0 Elmeasure Make with CT's and Phase indication lamps (R,Y,B) 22.5mm 220Vac.
14 sets of Phase Indication Lamps including connection through PVC try, complete in all respects.
-
-
-
... More
Design, Fabrication, Assembling of Supply, Installation, Testing and Commissioning of LT Floor Power Panel (Type -II) from high quality 2mm wall thickness CRCA sheet angle/flat iron mounted with hinged lockable front double door for each meter compartment to accomadate with fixing arrangement of Multi function meter (MFM), MCCB, other switchgears with bus bar ways in separate compartments painted with powder coated conforming to CPWD specification IP-55 .The LT Distribution panel must be free standing with 600mm height from floor,floor mounting and front execution type suitable for 415 V +/- 3% , 3 phase and neutral ,50 Hz system conforming I.E rules with necessary provision to connect cables of various sizes from the rear bottom side., 50 Hz, 4 wire power supply system.The assembly comprising of chassis ,famework, and fixed parts of metal casing of the switchgear shallbe provided with separte earthing. terminal.The formation must be compartmentalised in form 3b construction and must be supplied and installed. The Panel is comprising of the following items: (S.No. 3.01 - S.No. 3.07)
1
143000
143000
... More
1 No. of 200/250A 4P, MCCB Adjustable Thermal & Adjustable magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Incommer-I).
-
-
-
... More
1 No. of 160/200A 4P, MCCB Adjustable Thermal & Adjustable magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Incommer-II).
-
-
-
... More
1 Set of 300 Amps 4P, 36kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Busbar-I)
-
-
-
... More
1 Set of 250 Amps 4P, 36kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Busbar-II)
-
-
-
... More
5 No's of 63-100A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
5 No's of 40-63A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
2 Sets of Dgital Multifunction Meter Three Phase Class 1.0 Elmeasure Make with CT's and Phase indication lamps (R,Y,B) 22.5mm 220Vac.
10 Sets of Phase Indication Lamps, including connection through PVC try, complete in all respects.
-
-
-
... More
Design, Fabrication, Assembling of Supply, Installation, Testing and Commissioning of LT Floor Power Panel (Type -III) from high quality 2mm wall thickness CRCA sheet angle/flat iron mounted with hinged lockable front double door for each meter compartment to accomadate with fixing arrangement of Multi function meter (MFM), MCCB, other switchgears with bus bar ways in separate compartments painted with powder coated conforming to CPWD specification IP-55 .The LT Distribution panel must be free standing with 600mm height from floor ,floor mounting and front execution type suitable for 415 V +/- 3% , 3 phase and neutral ,50 Hz system conforming I.E rules with necessary provision to connect cables of various sizes from the rear bottom side., 50 Hz, 4 wire power supply system.The assembly comprising of chassis ,famework, and fixed parts of metal casing of the switchgear shallbe provided with separte earthing. terminal.The formation must be compartmentalised in form 3b construction and must be supplied and installed. The Panel is comprising of the following items: (S.No. 4.01 - S.No. 4.07)
1
150100
150100
... More
1 No. of 200/250A 4P, MCCB Adjustable Thermal & Adjustable magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Incommer-I).
-
-
-
... More
1 No. of 160/200A 4P, MCCB Adjustable Thermal & Adjustable magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Incommer-II).
-
-
-
... More
1 Set of 300 Amps 4P, 36kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Busbar-I)
-
-
-
... More
1 Set of 250 Amps 4P, 36kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Busbar-II)
-
-
-
... More
6 No's of 63-100A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
5 No's of 40-63A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended (Outgoing).
-
-
-
... More
2 Sets of Dgital Multifunction Meter Three Phase Class 1.0 Elmeasure Make with CT's and 11 Sets of Phase indication lamps (R,Y,B) 22.5mm 220Vac.
-
-
-
... More
SITC of 100A 4 Way Busbar Box type including fixing, cutting the wall and making good the same including finishing the wall with wall puty and paint, etc as required (Complete in all respects including required sizes of copper thimbles for each circuit/submain with colour coded PVC seleeves and connecting the existing Submain/ Circuit Wiring with the Busbar .
30
462000
15400
... More
Proviidng & laying of 4 core, 240 Sq.mm XPLE Insulated Armoured Aluminium Cable in DWC HDPE Pipe at a depth of 600mm including making end terminations on both side with heat shrinkable kits, complete in all respects.
80
200000
2500
... More
Proviidng & laying of 4 core, 120 Sq.mm XPLE Insulated Armoured Aluminium Cable on surface /walls with MS Clamps including making 8 no's of end terminations on both side with heat shrinkable kits, complete in all respects.
80
113680
1421