Islamic University Of Science And Technology Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Islamic University Of Science And Technology - IUST Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Feb 2025
Closing Date22 Feb 2025
Tender Amount₹ 44,00,000
Costs
EMD
₹ 88,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_IUST_272194_1Tender No
IUST/EW/25/TEND/ELE/ADMINSS/12Tender Authority
Islamic University Of Science And Technology ViewPurchaser Address
-Website
http://https://www.iustlive.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and Installation of 11 kV Horn Gap Fuse Set 3 Phase 200A as per REC standard F6.
1
6479
6479
... More
Supply and Installation of 9 Metre. long steel tubular pole ST-410 (SP33) IS 2713(part-II )1980 as per REC/KPDCL standards.(approximate weight of 154 Kg)
2
19800
39600
... More
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole. (As per Drawing Approved by Engineer Incharge)
4
4681
18724
... More
Supply and Installation of GI Channel/Angle/Flat of sizes including clamps.for L.A Set/G.O Set/Horn Gap, Transformer Bed etc as required on site.
500
154
77000
... More
Supply and Installation of Galvinized Nuts and Bolts and washers of sorts. (Galvanised as per IS-2633/1986)
15
154
2310
... More
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, supply and installation of Earthing pipe of 40 mm nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip (25mm x 5mm) for neutral earthing of size 25 mm x 3 mm for connection of transformer body,DTR structure, Transformer neutral, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. (As per Drawing In Tender Document or Should get drawing before doing Earthing )
3
10584
31752
... More
Supply and Installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5Metre long through GI Strip. As per REC Standard for Earthing.
6
2762
16572
... More
Supply and Installation of Earthing insulating boots.
30
23
690
... More
Supplying & laying of 300 Sq.mm Single Core of Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part -1) 1988 with upto date amendments,including thimbling with 300 Sq mm Al lugs, 30mm dia or required sizes of cable Glands, Colour coded heat shrinkable seleeved tags for phase indications, complete in all repects.
150
1004
150600
... More
Supplying & laying of 240 Sq.mm 3.5 Core Armoured Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part -1) 1988 with upto date amendments,including thimbling with 240 Sq mm Al lugs, Heat shrinkable end termination Kits, 63 mm dia or required sizes of cable Glands, Colour coded heat shrinkable seleeved tags for phase indications, complete in all repects.
200
2089
417800
... More
Supplying & laying of 185 Sq.mm 3.5 Core Armoured Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part -1) 1988 with upto date amendments,including thimbling with 185 Sq mm Al lugs, Heat shrinkable end termination Kits, 50 mm dia or required sizes of cable Glands, Colour coded heat shrinkable seleeved tags for phase indications, complete in all repects.
200
1745
349000
... More
Supplying and Laying of LT 120 mm² AB Cable with insulated neutal cum messanger (3X120+1x16+1X95) including the required sizes of heat shrinkable end termination kits, pvc insulated lugs and glands. The Cable Shall be in accordance with the technical specification of KPDCL standards.
400
834
333600
... More
Providing & fixing of LT Aluminium lugs with PVC heat shrinkable seleeves of sizes 70Sq.mm to 300Sq.mm including crimping, etc as required, complete in all respects.
24
350
8400
... More
Providing, design and fabrication of outdoor type feeder pillar made out of 2mm thick CRCA coated MS sheets, water and weather prooof including the copper basbar of current rating of 300A, with provision of atleast 4nos of 4core cables including G.I nuts, bolts and washers with 4 sets of phase indications. the feeder pillah should have legs and mounting structure of made out of G.I angle iron and the feeder pillar must be fixed in the concrete cement.
2
15000
30000
... More
Providing, design and fabrication of outdoor type feeder pillar made out of 2mm thick CRCA coated MS sheets, water and weather prooof including the copper basbar of current rating of 200A, with provision of atleast 4nos of 4core cables including G.I nuts, bolts and washers with 4 sets of phase indications. the feeder pillah should have legs and mounting structure of made out of G.I angle iron and the feeder pillar must be fixed in the concrete cement.
1
12500
12500
... More
Supply and Installation of Insulated Suspension/Tension Clamp with complete fittings for LT AB Cable.
50
278
13900
... More
Supply and Installation of Suspension Fitting (2 Bolt) for LT Line.
20
354
7080
... More
Supplying and laying of ACSR Rabbit (100Sqmm) Conductor.
100
110
11000
... More
Supplying and laying of ACSR to Cable Connector/Insulating Piercing Connectors
24
271
6504
... More
Supply and Installation of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm.
9
728
6552
... More
Supply and Installation of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
12
264
3168
... More
Providing & fixing of 16kN Polymer Shackle Insulators with G.I mukhi Clamps (50x6mm) fixed with lockable G.I nuts, bolts and washers, etc as required.
8
316
2528
... More
Supply and Installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete. (As per CPWD and REC Standards)
2
4092
8184
... More
Supply and Installation of Wedge Connectors / PG Clamps.
18
1560
28080
... More
Supply and Installation of Danger Plates with Clamps.
4
161
644
... More
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of Transformer Bed including form work etc as required as per the approved drawings of Incharge Engineer.
4
5500
22000
... More
Supply and Painting of Poles with Red Oxide.
6
321
1926
... More
Supply and Painting of Poles with Aluminium Paint and 2 Coats of orange paint.
6
538
3228
... More
Supply and Installation of Sundry items like aluminium lugs, Jumpers, binding Tape, etc.
1
1128
1128
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, bolted with the Angle Iron base Including G.I. bolts & nuts, etc. as required.
300 mm width X 50 mm depth X 1.6 mm thickness.
30
1325
39750
... More
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials (Heat shrinkable PVC Seleeves and Aluminium Lugs) of sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
16
450
7200
... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
300 mm dia.
170
1108
188360
... More
Design, fabrication, Assembling of supply, installation, testing and commissioning of LT Main Power Panel for for 400KVA Substaion of cubical main type panel board from high quality 14 SWG 2mm wall thickness CRCA sheet angle/flat iron mounted with hinged lockable front double door for each meter compartment to accomadate with fixing arrangement of energy meter, Multi function meter (MFM),MCCB, Bus bar ways in separate compartments painted with powder coated conforming to CPWD specification IP-55 .The LT Distribution panel must be free standing ,floor mounting and front execution type suitable for 415 V +/- 3% , 3 phase and neutral ,50 Hz system conforming I.E rules with necessary provision to connect cables of various sizes from the rear bottom side., 50 Hz, 4 wire power supply system.The assembly comprising of chassis ,famework, and fixed parts of metal casing of the switchgear shallbe provided with separte earthing terminal.The formation must be compartmentalised in form 3b construction and must be supplied and installed.
1
1090359
1090359
... More
The Bus bars will be Copper purity 99.9% / electrolytic grade E91 Aluminium. Panels will be powder coating (60-80micron as per IS:13871 for indoor and 90-100 micron for outdoor), include one size higher terminal block in cable alley and interconnecting wires between bus bars and terminals via MCB. All Bus-Bar alley and relay compartments shall be provide fully automtic control thermotate with strip heater.
-
-
-
... More
1 No. 800Amps 4P EDO type Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 4NO + 4NC Auxiliary contacts, ACB conforming to IS-1397-2 (1993) and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for Bus duct connections on incomer side and bus bar connection at output sides. (Incommer-I)
-
-
-
... More
Metering, INDICATOR AND RELAYs
Provide 3 Nos. Resin cast CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements covering A,V,Hz, PF, kW,VAr,VA, kVA, kVAR, kWH, kVAH, kVARH,MDI, Harmonics,Run Hours, RS-485 Port, LCD display with class-0.5 accuracy for all incomer feeder.
-
-
-
... More
E-Series R,Y,B phase indication lamps with 4Nos. SP HRC fuses as per fault requirement for each Incomer.
-
-
-
... More
Provide 3Nos indicating lamps for status indication "ON","OFF" , Tripped due to earth fault on each incomer and outgoing MCCB
-
-
-
... More
TVSS AND BUS BARS FOR EACH SECTION
-
-
-
... More
1000 Amps 4P, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.
-
-
-
... More
1 No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. Make & Model: Argos-AG-230-40T2-E or eq. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by TUV,CE,ROHS,UL94V-O..
-
-
-
... More
Outgoings:
-
-
-
... More
1 Nos. 400A 4P, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 50KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.(OG-I)
-
-
-
... More
1 Nos. 320A 4P, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 50KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.(OG-II)
-
-
-
... More
6 Nos. 250A 4P, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 50KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.(OG-III to OG-VII)
-
-
-
... More
1 Nos. 320A 4P, MCCB built in microprocessor based release (adjustable O/L & S/C) of fault breaking capacity 50KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides & Aux. Ccontacts for BMS connections. MCCBs neutral shall be protected & adjustable as a Neutral unprotected / Neutral protected at 0.5 In/ Neutral protected at In. MCCB shall conforming to IS-1397-2 1993 as amended.(OG-VII)
-
-
-
... More
2 Nos. 125A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.(OG-VIII)
-
-
-
... More
1 Nos. 63A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended.(OG-IX)
-
-
-
... More
4 Nos. of 4 Pole, 415V, 250A onload panel mounted centre handle changeover switch including connections , etc as required, complete in all respects with ph indication lamps on either supplies.
-
-
-
... More
1 No. of 4 Pole, 415V, 400A onload panel mounted centre handle changeover switch including connections , etc as required, complete in all respects with ph indication lamps on either supplies.
-
-
-
... More
1 No. of 4 Pole, 415V, 320A onload panel mounted centre handle changeover switch including connections , etc as required, complete in all respects with ph indication lamps on either supplies.
-
-
-
... More
1 No. of 4 Pole, 415V, 125A onload panel mounted centre handle changeover switch including connections , etc as required, complete in all respects with ph indication lamps on either supplies.
-
-
-
... More
12 Nos. of Digital Voltmeter for each outgoing, with all connections, etc as required.
-
-
-
... More
33 kV HT Metering CT AND PT Operated for Receiving Station, IUST.
-
-
-
... More
33kV CT/PT Combined Unit, 3-phase, 50 Hz, ONAN cooled, outdoor type. The combined unit, CTs and PTs shall be as per below specifications.The CT ratio shall be 60/5 for 1.5, 2 and 3.15 MVA, 33/11kV Transformers.
The rated burden of CT shall be 7VAThe PT shall be 33 kV/110 volts / √3, Three phase PT with rated burden 20VA per phase with proper colour coded identification. PTs shall be of uniform insulating and One minute power frequency dry withstand voltage 70kV.
1
200000
200000
... More
Metering cubicle for 3phase 4 wire metering system suitable for 3 phase, HT, tri-vector bidirectional Net Energy meter with sealing and locking facility made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement.The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening dooriIncluding supply and fixing of 75mm GI pipe between CT/PT combined unit and metering cubicle for CT/PT wiring to tri-vector meter.The Meter shall have data monitorium system by using Check Meter.
-
-
-
... More
MS Channels for mounting CT PT Combined Units with nuts and bolts of size (100 x 50 x 5 mm)
-
-
-
... More
3Ph4 Wire HT CT/PT operated Fully static Smart Net Tri-Vector Energymeters DLMS Compliant Category 'C' with RS232 port . 33kV/√3 /110V/√3, Ph-N (3P, 4W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc.
-
-
-
... More
PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB).
-
-
-
... More
Copper Lugs preferably ring type duly crimped for termination of wires and tapes
-
-
-
... More
ACSR Jumpers with hardware fittings like ACSR to CT/PT unit bush clamp, other hardwares as per site requirement
-
-
-
... More
Earthing by way of 40 mm GI Pipe earthing . Job includes , excavation, enhancement materail and Main Hole Chamber (500x450x600)mm with frame and cover.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%