Islamic University Of Science And Technology Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Islamic University Of Science And Technology - IUST Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date16 May 2023
Closing Date23 May 2023
Tender Amount₹ 8,80,000
Costs
EMD
₹ 17,600Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_IUST_201972_2Bid Award Id
ViewTender No
IUST/EW/ELE/TEND/BH/22/04-BTender Authority
Islamic University Of Science And Technology ViewPurchaser Address
-Website
http://https://www.iustlive.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
1 No's of 320A 4P, MCCB Adjustable thermal and fixed magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. (OUTGOINGS)
-
-
-
... More
1 No's of 160A 4P, MCCB Adjustable thermal and fixed magnetic release of fault breaking capacity 36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. (OUTGOINGS)
-
-
-
... More
1 No. of 160A Onload Changeover switch.
-
-
-
... More
1 Set of 320 Amps 4P, 36kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires. b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Approved IS Standaed or as per CPWD standards) {OUTGOING BUSBAR}
-
-
-
... More
(a). 1 No. of Dgital Multifunction Meter Three Phase Class 1.0 Elmeasure Make with required CT.
(b).3 set of Phase Indication lamps (R,Y,B) 22.5mm 220 Vac.
-
-
-
... More
Design, fabrication, Assembling of supply, installation, testing and commissioning of LT Floor Power Panel of cubical main type panel board from high quality 14 SWG 2mm wall thickness CRCA sheet angle/flat iron mounted with hinged lockable front double door for each meter compartment to accomadate with fixing arrangement of energy meter, Multi function meter (MFM),MCCB, Bus bar ways in separate compartments painted with powder coated conforming to CPWD specification IP-55 .The LT Distribution panel must be free standing ,floor mounting and front execution type suitable for 415 V +/- 3% , 3 phase and neutral ,50 Hz system conforming I.E rules with necessary provision to connect cables of various sizes from the rear bottom side., 50 Hz, 4 wire power supply system.The assembly comprising of chassis ,famework, and fixed parts of metal casing of the switchgear shallbe provided with separte earthing terminal.The formation must be compartmentalised in form 3b construction and must be supplied and installed.The Single Floor Panel is comprising of the following items from S.No. 2 to S.No. 2.09 :
Note: The following items of this panel are required for one Panel Set, total number of such panels along with following items required are 4.
4
674000
168500
... More
1 No. of 250A 4P, MCCB Adjustable thermal and fixed magnetic release of fault breaking capacity 25KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as Note: (1 No. to be installed in each panel set) {INCOMMER-I}
-
-
-
... More
1 No. of 100A 4P, MCCB Adjustable thermal and fixed magnetic release of fault breaking capacity 25KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as Note: (1 No. to be installed in each panel set) {INCOMMER-II}
-
-
-
... More
1 Set of 200 Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Approved IS Standaed or as per CPWD standards)
Note: (1 No. to be installed in each panel set) {BUSBAR-I}
-
-
-
... More
1 Set of 100 Amps 4P, 25kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar.(Approved IS Standaed or as per CPWD standards)
Note: (1 No. to be installed in each panel set) {BUSBAR-II}
-
-
-
... More
4 No's of 63A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. Note: ( 4 No.'s to be installed in each Floor panel)
-
-
-
... More
4 No's of 40A 4P, MCCB fixed thermal and fixed magnetic release of fault breaking capacity 16KA (Ics=75%Icu) with Phase spreader & Phase Barriers at both sides. MCCB shall conforming to IS-1397-2 1993 as amended. Note: ( 4 No.'s to be installed in each Floor panel)
-
-
-
... More
2 No's of 63A, TPN C CURVE MCB.
Note: (2 No's to be installed in each Floor panel)
-
-
-
... More
1 No. of 32A, DP C CURVE MCB.
Note: (2 No's to be installed in each Floor panel)
-
-
-
... More
1 Set of Digital Multifunction Meter Three Phase Class 1.0 (Elmeasure or equivqlent Make) with Ph. Indication Lamps & C.T.’s Note: ( 1Set to be installed in each Floor panel)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements