Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Islamic University Of Science And Technology - IUST Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Feb 2025
Closing Date24 Feb 2025
Tender Amount₹ 21,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Fixing of Array junction box & Main junction box with IP 65 protection and proper termination arrangement for incoming and outgoing cable along with glands, with required size lugs with colour coded pvc heat shrinkable seleeves and other accessories etc. as required.

-

-

-

... More
Lightning (copper) and surge voltage protections with all arrangements and accessories as approved by the Coordinator CREST.

-

-

-

... More
Proper Copper Plate earthings for Inverter as approved by the Coordinator CREST with copper strip of size 25mmx3mm with test joints from earthing plate to the ground inverter with watering arrangements by way of providing & fixing of GI pipe from grpund to earthing plate with main hole cover.

-

-

-

... More
Copper coated G.I chemical earthigs for Mounting structure from roof to building with bobin inulators, GI strip 25mmx5mm with test joints, complete in all respects.

-

-

-

... More
MPPTs (Maximum Power Point Trackers): Number of MPPTs: 3-4, which allows for better energy capture, especially beneficial for varied sunlight conditions like in Jammu and Kashmir. String Inputs per MPPT: Multiple inputs per MPPT (usually 2-4), allowing greater flexibility in panel layout and reducing shading effects.

-

-

-

... More
Providing and wiring with 1x 4.00 Sq.mm Copper solar wire including 2mm thick heavy duty PVC Conuit and bends for 308 PV Modules of commulative capacity of 100.10Kwp including dismanteling the existing wiring and making the connections as per MNRE guidelines and as approved by the Coordinator CREST.

800

95

76000

... More
Supply, fabrications, installation, testing and commissioning of DC DB made out of 2mm thick CRCA coated MS Sheets, CRCA coated MS angle iron with following switchgear, meetring, indication, cable end terimations, glands, etc as required, complete in all respetcs. 01. 1 No. of Digital energy Meter with LED indications for status, fault and revers polarity and alarm system for critical faults. 02. 2 No's of Double Pole DC Isolator Switch of volatge rating ≥ sytem volatge, current rating ≥ 1.25x maximum array current manually operating with the locable handle for maintenance safety. 04. 2 No's of Double Pole thermal magnetic DC MCCB of rating 100A, 36KA braking capacity designed to handle maxiumum short circuit current, overload tripping. 05. 04 No's of PV-specific DC fuses to handle high DC currents and prevent arcing with voltage rating: ≥ system voltage, Current Rating: Slightly above the maximum PV string current. 06. Class II or III DC SPDs with voltage rating: ≥ system voltage, response time 25 ns for thermal disconnection for safe operation. 07. Electrolytic grade copper with Heat-shrinkable sleeves or epoxy coated Busbar and current capacity rated for peak current with 25% safety margin.

2

20000

40000

... More
Providing and Installation of Smart Three NET Bidirectional Energy Meter for 50Kw PV plant with AMR Compatability for remote data monitoring, including connections, modem (if required) complete in all resoects

3

19000

57000

... More
Proper testing and commissioning of whole 2x50Kw Hybrid Pv plant including making the arrangement for its proper commissioning by way requirement of any modifications for earthing tests, lightening protection, proper battery bank size and connection, proper end terminations, cleaning of all PV Modules, cleaning and proper dressing with leveling of PV module yard through manual means.

1

19500

19500

... More
Supply, installation, testing and commissioning of Battery less Solar Hybrid Inverter/PCU of capacity 50Kw (AC) with 1000 V DC max. Input voltage and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with better efficiency ,total harmonic distortion less than 5% and suitable for ambient temperature from -20degree to 50 degree C, forced air cooling to maintain optimal performance. The Inverter /PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency and shall exite from minimum 160V(Ac). The Inverter /PCU must have Anti-islanding, short circuit, over-temperature, and overload protection. The Inverter /PCU must be IP65 rated for outdoor installation (dustproof and waterproof) and should compliance to IEC 61727, IEC 62116, and IEC 62109 or BIS standards for grid safety and protection. The Inverter /PCU must have Communication Interface: RS485, Modbus, Wi-Fi, Ethernet for remote monitoring. Note: detailed specifications are mentioned in Tender Document.

1

637500

637500

... More
Rewiring of existing PV Modules for 50.4Kwp ongrid rooftop PV plant with 1x4.00 Sq.mm Solar copper wires with 2mm thick PVC conduits, reintsallation of damaged PV Modules with proper base on roof and full waterproofing, proviidng and installation of MC4 Connectors, Copper coated G.I chemical earthigs for Mounting structure from roof to building with bobin inulators, GI strip 25mmx5mm with test joints, complete in all respects, Lightning (copper) and surge voltage protections with all arrangements and accessories as approved by the Coordinator CREST, reconnection of AC DB's , AJB Boxes with minor repair if any in the whole PV plant, connection of LT power cable with proper termination, icluding testing and commisiong of 50Kw Rooftop Ongrid Plant, complete in all respects.

1

50000

50000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.