Islamic University Of Science And Technology Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Islamic University Of Science And Technology - IUST Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Feb 2025
Closing Date22 Feb 2025
Tender Amount₹ 31,99,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduit with wall chasing in case of recessed conduits including filling the same with plaster and finished wall putty, etc as required.

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

50

233

11650

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

50

275

13750

... More
2 X 4 sq. mm +1 X 4 sq. mm earth wire

50

334

16700

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in exisitng surface/ recessed medium class PVC conduit , inclusding clearing the existing conduits (if any blockage) etc as required.

-

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

100

560

56000

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

100

1280

128000

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

100

80

8000

45

92

4140

... More
Providing and Wiring for single phase and neutral power plug points with 2 No's of 6A Switch Socket outlet with FRLS 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible wires in concealed or surface mounted 25 mm dia 2 mm thick PVC conduit/channel, including the cost SITC of switch socket accessories of approved make and design in 1.6 mm thick GI boxes in case of Recess and PVC Surface Box in case of Surface fitting with facecover plates and earthing the 5 pin of socket outlet with 2.5 Sq. mm green colour PVC insulated copper conductor stranded flexible FRLS wire etc. as required. No jointing of wires is alloweded from DB to Power Plug points.

25

3000

75000

... More
Providing and Wiring for single phase and neutral power plug points with 2 No's of 6A Switch Socket outlet with FRLS 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible wires in existing concealed or surface mounted PVC conduit, including the cost of SITC of 2 nos. 6 amps switched & socket of approved make and design in 1.6 mm thick GI boxes in case of Recess and PVC Surface Box in case of Surface fitting with facecover plates and earthing the 5 pin of socket outlet with 2.5 Sq. mm green colour PVC insulated copper conductor stranded flexible FRLS wire etc. as required. No jointing of wires is alloweded from DB to Power Plug points.

10

2270

22700

... More
Providing and Wiring for two single phase and neutral power plug points (looped) at distinct positions with 2 No's of 6A Switch Socket outlet with FRLS 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible wires in concealed or surface mounted 25 mm dia 2 mm thick PVC conduit/channel, including the cost of SITC of switch socket accessories of approved make and design in 1.6 mm thick GI boxes in case of Recess and PVC Surface Box in case of Surface fitting with facecover plates and earthing the 5 pin of socket outlet with 2.5 Sq. mm green colour PVC insulated copper conductor stranded flexible FRLS wire etc. as required. No jointing of wires is alloweded from DB to Power Plug points.

8

4000

32000

... More
Providing and Wiring for single phase and neutral heating power plug points with 1 No's of 6A Switch Socket outlet and 1No. of 16A Switch Socket (6 Module) with FRLS 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible wires in concealed or surface mounted 25 mm dia 2 mm thick PVC conduit/channel, including the cost of SITC of SITC of switch socket accessories of approved make and design in 1.6 mm thick GI boxes in case of Recess and PVC Surface Box in case of Surface fitting with facecover plates and earthing the 5 pin of socket outlet with 2.5 Sq. mm green colour PVC insulated copper conductor stranded flexible FRLS wire etc. as required. No jointing of wires is alloweded from DB to Power Plug points.

15

4000

60000

... More
Providing and Wiring for single phase and neutral heating power plug points with 1 No. of 6A Switch Socket outlet and 1No. of 16A Switch Socket (6 Module) with FRLS 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible wires in existing PVC conduit/channel, including the cost of SITC of switch socket accessories of approved make and design in 1.6 mm thick GI boxes in case of Recess and PVC Surface Box in case of Surface fitting with facecover plates and earthing the 5 pin of socket outlet with 2.5 Sq. mm green colour PVC insulated copper conductor stranded flexible FRLS wire etc. as required. No jointing of wires is alloweded from DB to Power Plug points.

5

2800

14000

... More
Providing and Wiring for single phase and neutral AC power plug points with 1 No. of DP Modular Socket outlet and 1No. of DP 25/32A Switch with combined /seperate 2M plate with FRLS 4 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible wires in concealed or surface mounted 25 mm dia 2 mm thick PVC conduit/channel, including the cost of SITC of switched & socket accessories of approved make and design in 1.6 mm thick GI boxes in case of Recess and PVC Surface Box in case of Surface fitting with facecover plates and earthing the 5 pin of socket outlet with 4.0 Sq. mm green colour PVC insulated copper conductor stranded flexible FRLS wire etc. as required. No jointing of wires is alloweded from DB to Power Plug points.

30

5480

164400

... More
Providing and Wiring for 30/32 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30/32 amps "C" curve, TP/TPNMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let with FRLS 4x4.0 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible wires in concealed or surface mounted 25 mm dia 2 mm thick PVC conduit/channel, including the cost of all required accessories of approved make and design and earthing the socket outlet with 4.0 Sq. mm green colour PVC insulated copper conductor stranded flexible FRLS wire etc. as required. No jointing of wires is alloweded from DB to Power Plug points.

6

8500

51000

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

5

369

1845

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 amps switch

28

103

2884

... More
15/16 amp switch

10

156

1560

... More
3 pin 5/6 amp socket outlet

20

122

2440

... More
6 pin 15/16 amp socket outlet

10

197

1970

... More
Bell push (2Module)

4

140

560

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
1 or 2 Module (75mmX75mm)

3

298

894

... More
3 Module (100mmX75mm)

5

327

1635

... More
6 Module (200mmX75mm)

5

402

2010

... More
8 Module (125mmX125mm)

5

454

2270

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

3

133

399

... More
3 Module

5

151

755

... More
6 Module

5

182

910

... More
8 Module

5

211

1055

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 32 A modular socket outlet and 25/32 A modular switch including connections, painting etc. as required.

3

827

2481

... More
Supplying and fixing call bell/ buzzer suitable for single phase,230 V, including connections, etc complete as required.

4

136

544

... More
SUB-HEAD-II: DISTRIBUTION BOARDS

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way, Double door with Glass Door

2

2950

5900

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

30

256

7680

... More
Double pole

4

656

2624

... More
Supplying and fixing 63A rating, DP 240 V, 10 kA, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.

2

829

1658

... More
Supplying and fixing 63A rating, TPN 415 V, 10 kA, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.

2

1512

3024

... More
Supplying and fixing 40A rating, TPN 415 V, 10 kA, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.

2

1512

3024

... More
SUB-HEAD-III: EARTHING SYSTEM

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.

2

17538

35076

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

25

1551

38775

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

30

1362

40860

... More
SUB-HEAD-IV: CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

150

980

147000

... More
SUB-HEAD-V:SUPPLY OF LIGHT FIXTURES AND FANS

-

-

-

... More
Supply of indoor type Slim surface mounted downlighter white CRCA powder coated LED light fixture with total system wattage 18W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflector, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED fixture should have minimum efficacy =100 lm/W and minimum system lumens 1800.

45

1689

76005

... More
Supply of Motion Sensor based surface/recess mounted downlighter white CRCA powder coated LED light fixture with total system wattage 15W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflector, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED fixture should have minimum efficacy =100 lm/W and minimum system lumens 1200.

16

2289

36624

... More
Supply of 2x2 36 Watt surface/recess mounted downlighter LED light fixture with total system wattage 36W covered by PMMA acrylic diffuser, die cast aluminium housing, high efficiency reflector, prewired electronic driver complete with all accessories suitable for operation on single phase 240V 50Hz AC supply as required. LED fixture should have minimum efficacy =100 lm/W and minimum system lumens 3600.

16

2500

40000

... More
Supply of 5 star rated 1200mm sweep ceiling fan, ISI marked, along with copper wound stator, blades, capacitor, downrod etc. but without regulator complete as required.

5

3500

17500

... More
SUB-HEAD-VI: INSTALLATIONS OF LIGHT FIXTURES AND FANS

-

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

77

206

15862

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

5

339

1695

... More
SUB-HEAD-VII: LT POWER PANELS

-

-

-

... More
Supplying, installation, testing & commissioning of Totally Type Tested Panels complying IEC 61439 -1/2 cubical with Internal arc withstand and impact resistance IK10 as per ICE62262. The panel shall be tested for an internal arc of 50kA for minimum 0.4 seconds. The degree of protection of minimum IP 42 for indoor and IP 65 for outdoor use. Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of minimum 2 mm thick for load bearing member and 1.6mm for Non load bearing member, 3mm thick for gland, plates i/c cleaning & finishing complete, having extensible type aluminium bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 50kA for 1 Sec., bottom frame shall be 100mm Height as per OEM standard, fabrication shall be done in transportable sections, Entire panel shall have a common aluminium earth bar of size 32mm x 6mm or as specified below at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al with form-4B construction. bus bars and control wiring with suitable size of PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- (S.No 39.01-S.No. 39.07)

1

300000

300000

... More
1 No of 320A 4P MCCB Microprocessor based release Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole) of fault breaking capacity 35/36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides and 1 Set of Phase indocations. MCCB shall conforming to IS-1397-2 1993 as amended.(I/C-I)

-

-

-

... More
1 No of 250A 4P MCCB Microprocessor based release of fault breaking capacity 35/36KA (Ics=Icu=100%) with Phase spreader & Phase Barriers at both sides and 1 Set of Phase indocations. MCCB shall conforming to IS-1397-2 1993 as amended.(I/C-II)

-

-

-

... More
2 Sets of 320 Amps 4P, 50kA, 500volts grade busbar chamber of suitable length with Aluminium busbars mount on SMC supports. All interconnections shall be as follows; a). Upto 63A, FRLS PVC insulated copper flexible colour coded wires b). 64Amp to 200Amp Copper Bus-bars and above Aluminium, current density of bus-bars shall not be less than 0.8Amps/sq.mm for Aluminium and 1.6Amps/sq.mm for copper cross sectional area of Bus Bar with phase indications.(Busbar)

-

-

-

... More
1 No. of 250A, Automatic Transfer Switch with controller, panel mounted, including connections, etc as required. The transfer switch shall function on low input. (Changeover)

-

-

-

... More
4 Nos. 63A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides including phase indication lamps on each outgoing. MCCB shall conforming to IS-1397-2 1993 as amended. (O/G-I)

-

-

-

... More
4 Nos. 40A 4P MCCB built in thermal magnetic based release (adjustable O/L, adjustable S/C) of fault breaking capacity 35KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides including phase indication lamps on each outgoing. MCCB shall conforming to IS-1397-2 1993 as amended.(O/G-II)

-

-

-

... More
Provide 3 Nos. Resin cast CTs, Class-1.0 and MFM True RMS type digital with min. features of measurements covering A,V,Hz, PF, kW,VAr,VA, kVA, kVAR, kWH, kVAH, kVARH,MDI, Harmonics,Run Hours, RS-485 Port, LCD display with class-0.5 accuracy for all incomers.

-

-

-

... More
SUB-HEAD-VIII: L.T. POWER CABLES

-

-

-

... More
Supply of 4 x 185 sq.mm. Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments.

40

2004

80160

... More
Supply of 4 x 120 sq.mm. Power Cables multi stranded Aluminium conductor, XLPE Insulated, cores laid up PVC tape / Extruded Inner sheath , Armour, FRLS at outer sheath,1100V grade as per IS 7098(Part 1) 1988 with upto date amendments.

40

1789

71560

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

80

77

6160

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required

-

-

-

... More
4 X 185 sq. mm (57mm)

2

670

1340

... More
Redistribution of exiitng Wirings, DB, by way of dismanteling the exisitng submain wiring, reinstallation of same after redistributing the load, etc as reqired.

1

8251

8251

... More
SUB-HEAD-IX: DIESEL GENERATOR WITH CABLING & FOUNDATION AND LT 3PHASE ENERGY METER.

-

-

-

... More
Providing,Installation,Testing & Commissioning of 3 Phase, CPCB-IV Compliance, 125 KVA Acoustic proof Diesel Generator set with microprocessor based AMF Panel including Minimum 30M copper Control Cable with suitable copper lugs, P/L of Minimum 30M Aluminium Cable of size 3.5x 120Sq.mm XLPE Armoued with suitable heat shrinkable Lugs, connections, 3 No's of 3M long Chemical Copper-G.I Pipe earthings with 5x25mm G.I Strips, nuts,bolts,washers, etc as required, complete in all respects as per CPWD Manual for DG sets with minimum 5 year warrenty including providing and laying of suitable concrete foundation as per CPWD standards/ approved drawings of Incharge Engineer.

1

1552200

1552200

... More
Providing,Installation,Testing of LV CT-operatrd 3-phase 4 wire energy meter, complete in all respects with load bearing capacity of minimum 150KVA.

1

9800

9800



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.