Irrigation And Flood Control Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Irrigation And Flood Control Department - IFC Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date18 Dec 2024
Closing Soon24 Dec 2024
Tender Amount₹ 8,32,75,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m

456.96

218

99800.06

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

116.18

12

1451.09

... More
Demolishing stone rubble masonary manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of engineer in charge (in cement motar)

103.5

1740

180136.58

... More
Providing & Laying of dry stone soling (nallah) (Incl. Supply)

261.04

937

244829.42

... More
Centering and shuttering incl. strutting, propping etc and removal of form work for;

-

-

-

... More
Foundations, footings, bases of columns etc. for mass concrete

1960.3

286

561331.91

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc

2026.24

628

1274403.65

... More
Suspended floors, roofs, landings, balconies and access platforms

364.34

718

261668.99

... More
Edges of slabs and breaks in floors and walls (under 20 cm vide)

16.8

262

4404.96

... More
Providing & laying in position, cement conc. of specified grade excl. the cost of centering & Shuttering. All work upto plinth level ,1:4:8 (1 Cement: 4 Coarse Sand: 8 Graded stone agg) 40 mm Nominal size (Crushed)

226.06

5202

1176167.57

... More
Providing & laying in position, cement conc. of specified grade excl. the cost of centering & Shuttering. All work upto plinth level ,1:3:6 (1 Cement: 3 Coarse Sand: 6 Graded stone agg) 20 mm Nominal size (Crushed)

528.36

5733

3029404.9

... More
Providing & laying in position, cement conc. of specified grade excl. the cost of centering & Shuttering. All work upto plinth level ,1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded stone agg) 20 mm Nominal size (Crushed)

150.94

6591

994883.28

... More
Providing & laying in position, Reinforced cement conc. of specified grade excl. the cost of centering & Shuttering. All work upto plinth level ,1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded stone agg) 20 mm Nominal size (Crushed)

253

7104

1797400.55

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level, 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

52.92

7788

412162.13

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size)

9.18

7564

69444.86

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.

-

-

-

... More
All works upto plinth level

163.78

8021

1313695.76

... More
Above P/Level & upto floor V level

38.87

9412

365846.38

... More
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span up to floor five level, including setting in position in cement mortar 1:3 (1 cement :3 coarse sand) including the cost of required centering, shuttering and curing but excluding the cost of reinforcement with: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)230mm wide and 250mm deep

0.67

12624

8458.45

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Mild steel and medium tensile steel bars

22774.3

115

2627015.51

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.

31659.71

123

3900476.27

... More
Providing and fixing of steel bolts with clipping arragement (Size as per requirement) Comp. Job

780

200

156000

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)

91.7

7877

722357.58

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

67.69

1455

98532.95

... More
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand) Nallah Stones

26.48

5402

143068.79

... More
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with:Cement mortar 1:6 (1 Cement : 6 coarse sand) Quarry Stones

288

7677

2211076.8

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc complete.50 mm thick with 20mm nominal size stone aggregate.

616

562

346284.4

... More
12mm thick plaster (1: Cement 4: Coarse Sand) mix

2011.02

283

570727.48

... More
15 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:4 (1 cement : 4 coarse sand) finished with a top layer 6 mm thick cement plaster 1:4 (1 cement : 4 fine sand).

295.06

327

96735.42

... More
Neat Cement Punning

167.91

71

11955.19

... More
Providing & fixing hexagonal chicken mesh having opening 20mmx20mm of 26 gauge at juncitons of concrete & brick work or between different material etc. as approved by architect and complete in all respect.

18.71

105

1964.55

... More
Providing and applying white cement based putty of specified thickness , of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick

295.06

181

53420.61

... More
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats

295.06

86

25566.95

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

8.64

3234

27943.49

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.fixed to steel window by welding. Window M. S grill is used @20kg/sqm

180

212

38160

... More
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125mm long

4

101

405.8

... More
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete, (double strip Horizontal type)

4

42

168.6

... More
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (1.50 mm thick)

8.64

906

7830.43

... More
Providing wood work in frames of doors, windows,clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately ):Kiln seasoned and chemically treated hollock wood

5.95

74353

442403.03

... More
Providing & Fixing Redfire pull handle in SS304, 12" length & 22mm dia as approved by architect and complete in all respect.

4

200

800

... More
Supply & fixing of clear toughned glass of 12 mm thick with all accessories, screws etc. as approved by architect and complete in all respect.(Ground to Third floor) Note:- Consideresing 300 mm extra height for both top & bottom faces for fixing the glass

10.8

300

3240

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes

5133.24

142

733540

... More
Providing & fixing high profile ribbed colour coated roofing on supported strucrure 0.5mm thick

105.84

1250

132300

... More
Providing and fixing plained eaves boarding.2nd class Deodar wood 250x32 mm (nominal size)

29.1

999

29072.36

... More
Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gram/m2

43.86

840

36848.98

... More
Providing /Supply and filling of nallah muck to specific grade incl ramming, dressing, watering and consolidation with PRR and carriage of material by mechanical means, transport from source to site of work complete job.

310.5

850

263925

... More
Providing and laying of graded stone aggregate at site of size range 63-45 mm crushed aggregate including laying WBM with specified stone aggregate, stone screening and binding material including sorting, spreading and consolidation with Power Road Roller including all carriages leads and lifts. Base course with 63-45mm size crushed aggregate including 13.20mm stone-screening/chippings. CJ incl carriage

202.5

2500

506250

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): KD wood

1.02

58000

59160

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).KD wood

27.94

2150

60071

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

6.84

9821

67181.45

... More
P/F of chain link fencing made out of 50mmx50mm mesh with 4mm thick wire. The job shall include The frame of the panel shall be made out of 50x50x5mm vertical angle posts to be embedded in cement concrete with 40x40x5mm horizontal struts and chain link fencing be anchored with 50mmx 6mm strips. The size of the panel shall be 1.80mx 1.80m without legs and 1.80m x 2.40m with legs.The shall be inclusive of all other accessories and carriages upto the site of work,complete job

61

8050

491050

... More
Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete,KD wood

7.4

58000

429200

... More
P/F of precoated galvinised iron corrugated sheets 0.40 mm in thickness in roofing, incl all other necessary items(Complete Job)

86.4

585

50544

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 500x500 mm

24.84

1535

38145.55

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C.flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.

2

8500

17000

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:25 mm dia. nominal bore,Medium

60

529

31782

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)25 mm nominal bore

6

691

4150.2

... More
Providing and fixing brass bib cock and stop cock of approved quality.20 mm nominal bore

16

334

5355.2

... More
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make,weighing not less than 1.970 kg.

4

3500

14000

... More
Providing/fixing of PVC water Tank of 1000 litres of Capacity of approved brand and manufacture complete job

2

4000

8000

... More
Electrical Fitting viz Lightening points, heating points and Fan points. The job shall include for lighting points in 1.50 mm and 2.50 mm pvc multi standard copper wire, 2.50sqm and 4.0 sqm lining for heating points and 1.50 mm wiring for fan points 6 Amp one way switch, 6 Amp MCB, 10 Amp DB MCB for lighting points, 16 Amp Switch socket, 10 Amp MCB 2 way DB for having MCB and sheets for holding MCB 120 mm ceiling fan, 350 watt electric fan ,PVC channel, 10 Amp DB and all other accessories (Complete Job)

-

-

-

... More
Lighting Points

20

1500

30000

... More
Heating points

8

1800

14400

... More
Fan points

2

2500

5000

... More
P/F of Air valves for 500mm,400mm dia,350 mm dia and 250 mm dia delivery main incl testing and successful commissioning (complete Job)

4

16000

64000

... More
Fabrication,providing and laying of 300 mm dia ,5.20 mm thick MS pipe in position , joining, welding at both ends with 12mm thick flanges and connecting the flanges with 12 mm thick zinc coated bolts of bitumen paint area single coat of red oxide paint Complete in all respects with specials such as gaskets incl c/o all material with all leads and lifts , labour , machinery giving satisfactory hydraulic testing. The job shall include providing of inspection chambers at evry 24 mtr

-

-

-

... More
300mm dia

300

7840

2352000

... More
250 mm dia

450

6800

3060000

... More
200mm dia

1500

5700

8550000

... More
Provision for Dewatering/Const of Coffer dams for diversion of water during execution

1

150000

150000

... More
Carriage of materials by M.T. from source upto site of work incl loading, unloading & Stacking of materials

-

-

-

... More
Stone soling/stones avg. 09 Km

567.24

309

175776.33

... More
40 mm stone aggregate 09 km

201.69

286

57745.86

... More
20 mm agg from 09 km

1161.28

263

305857.93

... More
Sand from avg. 18 Km

714.96

383

274373.05

... More
Bricks from 110 Km

45850

3

171479

... More
Cement/Steel from avg. 14 Km

510.84

294

150467.92

... More
Extra Carriage of Materials from road site upto actual site of work by an avg head load of 800 mtrs

-

-

-

... More
Stone soling/Stones

64.51

1007

64966.73

... More
40 mm stone agg

45.51

925

42114.5

... More
20 mm agg

275.32

856

235679.43

158.03

856

135276.84

... More
Cement

110.66

371

41162.2

22.01

799

17587.31

... More
Extra Carriage of Materials from road site upto actual site of work by an avg head load of 500 mtrs

-

-

-

... More
Stone soling/Stones

12.78

698

8929.13

... More
40 mm stone agg

13.53

642

8686.4

... More
20 mm agg

76.49

593

45425.88

48.69

593

28916.02

... More
Cement

30.28

269

8165.61

... More
Extra Carriage of Materials from road site upto actual site of work by an avg head load of 300 mtrs

-

-

-

... More
Stone soling/Stones

139.23

493

68647.35

... More
40 mm stone agg

98.28

453

44529.69

... More
20 mm agg

472.68

419

198109.64

302.16

419

126641.3

... More
Cement

143.2

201

28850.5

... More
Extra Carriage of Materials from road site upto actual site of work by an avg head load of 200 mtrs

-

-

-

... More
Stone soling/Stones

3.92

390

1529.9

... More
40 mm stone agg

3.1

358

1111.75

... More
20 mm agg

20.34

331

6747.59

12.04

331

3994.15

... More
Cement

7.92

167

1325.57

... More
Pumping unit supply, installation, testing and commissioning of Centrifugal Vertical Turbine pump unit 06 Cusec 71 Meters dynamic head along with motor and allied accessories for Lift Irrigation scheme LIS Gantamulla Stage 1st of MISD Baramulla…...as per specification laid in appendix “B” and “C” and other Terms and conditions laid in eNIT.

3

2340000

7020000

... More
M.S Rising Main Fabrication, Providing, installation, testing and commissioning of 500mm Nominal Diameter ERW ISI mark 6.3mm thick M.S Rising main to be laid from RD 0 to 470 Mtr at lift irrigation scheme Gantamulla Stage 1st. The job requires involvement of highly skilled professionals for carrying out laying and welding jobs. The pipe shall be welded end to end using high quality electrodes by a D.C welding machine for the completion of work. The job includes charge of earth excavation in all types of soil with the help of JCB & Manual labors in high terrain wherever required for laying of pipe. The job includes cost on account of hiring D.G set, welding set, gas cutter, superior quality electrodes, dewatering pumps etc. for the completion of work. The job also includes fabrication of offsets/bends wherever necessary for proper alignment. The pipe shall have to be provided with two coats of anti-corrosive bitumastic paint. SPECIFICATIONS: Nominal diameter of pipe : 500 mm Outer Diameter : 508 mm Thickness of pipe : 6.3 mm Length of each pipe: Pipe shall be in single random length from 4 -7Mtr as per clause 12.4 of IS 3589. Type of Welding : ERW Type Quality of M.S plate to be used for manufacture : As per IS 2062(Grade Fe410) Pipe to be Manufactured : As per IS 3589 having one longitudinal joint with latest amendments Hydraulic test Pressure: As per 10.1 of IS3589 End Preparation: As per 17.1 of IS 3589 where V Groove is to be made by machine grinding edges of the pipe. Type of Welding to be used for joining pipes: D.C arc Welding. Tolerance : As per clause 12.3 of IS 3589 The installation shall have to be carried out in accordance with IS 5822

470

9068

4261960

... More
Reflux Valve Supply, installation, testing and commissioning of 300 mm Size Reflux Valve Resilient Seated Double Flanged Swing Check Valve (NRV) with by-pass arrangement and FBE Powder coating inside and outside color with Min. Coating thickness of 250 microns. Face to face dimensions as per EN 558-1/DIN 3202-F6/IS 5312 & Flange drilling as per IS1538/BIS 4504. The valve shall be complete with in-built bypass arrangement. Material of Construction Body, Cover: Ductile Cast Iron of grade GGG40(IS1865 Gr. 400/15) Disc : Ductile Cast Iron of grade GGG40, fully vulcanized with EPDM rubber Gasket: EPDM rubber Surface Protection: Epoxy Powder coating Pressure Rating: P N: 1.6 Hydrostatic pressure: B o d y = 24 Kg/cm2 Seat= 16 Kg/cm2 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar.

3

146000

438000

... More
Double Flange Sluice valve Supply, installation, testing and commissioning of 300 mm Size Ductile Iron Resilient seated Double Flange Sluice valve with body & bonnet of ductile cast iron The valve face to face dimension as per BS 5163:1989/IS 14846:2000/DIN 3202 F4 and flange drilling as per IS: 1538. The valves shall be FBE coated both inside and outside with pocket less body passage. Material of Construction: Body: Ductile Cast Iron of grade GGG40 (IS1865/ EN JS 1050 Gr. 400/15) Wedge: Ductile Cast Iron of grade GGG40, (IS1865/EN JS 1050 Gr. 400/15) fully vulcanized with EPDM rubber Stem: Stainless Steel AISI: 410(min 13% Cr.) as per IS6603 or ASTM/276 or IS 1570 Stem Nut: LTB2 high tensile Brass Bonnet Gasket: EPDM rubber/Neoprene rubber Stem Sealing: O-rings of NBR Surface Protection: Epoxy coating. Pressure rating: 1.6 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/TALIS Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar.

3

126000

378000

... More
500 mm Size Reflux Valve Supply, installation, testing and commissioning of 500 mm Size Reflux Valve Cast Iron as per IS5312:20024 Resilient seated Double Flanged Swing Check Valve (NRV) with by-pass arrangement and paint coating inside and outside suitable color with Min. Coating thickness of 250 microns. The valve shall be complete with in-built bypass arrangement. Material of Construction Body, Cover: Grey Cast Iron of grade FG200 Disc: Grey Cast Iron of grade FG200, fully vulcanized with EPDM rubber Gasket: EPDM rubber/ As per IS 5312 Surface Protection: As per IS 5312 Pressure Rating: P N: 1.6 Hydrostatic pressure: B o d y = 24 Kg/cm2 Seat= 16.0 Kg/cm2 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/TALIS Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar.

2

357000

714000

... More
Delivery Pipes and Manifold: 1. Delivery pipes-------------------35 Meter (Total length) Supply, installation, laying and handling of Delivery pipeline out of 300 mm Nominal dia. MS pipe which includes the charge of fabrication of offsets, welding work, nuts & bolts, washers etc for the completion of work and shall have following specifications: Nominal diameter of pipe= 300 mm Outer Diameter = 323.9 mm Thickness of pipe = 7.1 mm Length of each pipe = 4 -7Mtr Type of Welding = ERW Type Quality of M.S plate to be used for manufacture = As per IS 2062(Fe410) Pipe to be Manufactured= As per IS 3589 having one longitudinal joint with latest amendments Type of Welding = D.C arc Welding. Tolerance = As per clause 12.3 of IS 3589 2. Flanges Supply, installation, testing of 300 mm Nominal dia. M.S flanges having thickness 24 mm/ AS PER IS:6392 as per site requirement (18 no) for Manifold junction with nuts, bolts, washers & allied works 3. Manifold: Fabrication, Fitting, testing and commissioning of 500 mm Nominal Diameter delivery manifold for 03 No. 300mm nominal diameter deliveries of unit no. 1,2 & 3 and connecting it with 500mm nominal diameter rising main. The manifold is to be fabricated out of 500 mm Nominal diameter pipe 6.3mm thick with approximate 4.5 M in length by way of following: -  Horizontally placing the 4.5 Meter long 500mm Nominal diameter 6.3mm thick pipe to act as manifold body.  Cutting three holes of Nominal Dia of 323.9mm Holes at suitable distances from each other as per the alignment of delivery pipes and then connecting the ND 300mm pipes coming out from the Pump house to the manifold body through welding.  Cutting circular hole of size 508mm diameter approx in the manifold from Rising main side preferably at the middle of the manifold body or as per the alignment of rising main as per site conditions and then connecting the ND 500mm rising main through welding.  Fabrication providing and fitting of 495.4 mm diameter mild steel blinding plates (end caps) on both sides of common header. The end plates are to be fabricated out of 8 mm thick M.S Plate.  Providing and fitting of Compensated opening plates for additional enforcement to the riser opening and inlet openings of the Manifold. The details of the compensated opening plates shall be as follows Compensation Pads for discharge line connection pipes: Total No.’s to be used 3.00 NO. Outer Diameter 450 mm Inner Diameter 323.9 mm Thickness 16 mm Compensation Pad for pressure main: Outer Diameter 705 mm Inner Diameter 508 mm Thickness 16 mm 4. Painting of delivery manifold with fittings: - Providing & application of synthetic enamel paint to delivery manifold by the way of following: - a) Cleaning of metal surfaces by application of water, emery paper etc., to remove dirt, grease stains, rust etc. The job also includes removing of old loose paint. b) Applying of steel Priming coat c) Application of two coats of synthetic enamel paint to all surfaces by brushing or spraying method. All consumable items for cleaning/painting shall be in contractor’s scope Make of Paint: Asian /Nerolac/Berger The equipment to be painted and color shading/ sequence is as below: Equipment: Paint/Shade Common headers with riser outlets: Synthetic Enamel /Dark Grey Delivery Manifold pipes: Synthetic Enamel/Sky Blue

1

468000

468000

... More
Gantry Design, manufacture, supply, erection, & commissioning of 05-ton capacity with monorail and chain-pulley block suitable for handling a load of 05-ton capacity in both directions i.e., long-travel movement and cross-travel movement. Major components of the crane structure shall comprise of following items: a) RUNWAY GIRDERS: shall be fabricated out of ISMB 200, the girder beams shall be fitted on tie-plates of 300X300X6mm dimensions fitted on the wall with the embedded bolts & nuts. The upper flange of the runway girder shall be fitted with channel section ISMC 150. ISSQ 30mm shall be fitted on channel section by way of welding and then finishing along the length of runway girder to ensure smooth movement of bridge girders end carriages designed for long movement by means of manually driven gear & pulley mechanics. Length of each runway = 8Mtr (02no). b) END CARRIAGE: two no. end carriages shall be fabricated out of ISMC 200, suitably fitted with 250mm diameter MS wheels fitted with suitable bearings as per requirement and instruction of site engineer. A gear and pinion mechanism is also to be designed, fabricated and installed in such a way that both the end carriages run in synchronization with each other connected by means of a spindle of suitable diameter fitted with a pulley with endless chain to facilitate long travel movement of crane bridge manually throughout the machine floor. Suitable size and number of plumber blocks are also to be installed in the mechanism. c) BRIDGE GIRDER: The bridge girder shall be fabricated out of ISMB 350 for a span of 8Mtr. The bridge girder rests over the end carriage by means of M.S Plate of 300X 300 X 10mm dimensions with nuts & bolts. d) MONORAIL BLOCK: one unit of 05-ton capacity heavy duty monorail block of indef/globe/Elephant with ISI mark suitable to operate inside the pump house shall be mounted on the lower flange girder to facilitate the cross-travel movement. e) CHAIN PULLEY BLOCK MANUALLY OPERATED: one unit of 05-ton spur gear type capacity globe/indef/Elephant make shall be provided. Minimum hoist shall be 6.00 mtrs. The job also includes painting of entire structure with two coats of A grade enamel yellow paint after proper surface preparation and application of metal primer coat.

1

297000

297000

... More
Dismantling Joint Fabrication, Providing, installation, testing and commissioning of 300 mm Nominal Diameter Mild Steel Slip on/dismantling joint in 300 mm dia. Delivery pipes. The body of the Dismantling joint shall be minimum 12 mm thick. The flanges shall be drilled as per IS:6392 and shall be 28mm thick (03 No.). The joint shall comply to a minimum expansion/contraction of 50 mm. The job also includes P/F of Nuts, Bolts, Packing, tie rods & Washers required for the completion of work.

3

38000

114000

... More
Slip on Joint Fabrication, Providing, installation, testing and commissioning of 500 mm Nominal Diameter Mild Steel Slip on/dismantling joint in 500 mm dia. raising main. The body of the Dismantling joint shall be minimum 12 mm thick. The flanges shall be drilled as per IS:1538 and shall be 22mm thick (3 No.). The joint shall comply to a minimum expansion/contraction of 50 mm. The job also includes P/F of Nuts, Bolts, packing & Washers required for the completion of work.

2

63700

127400

... More
Tool Kit Supply of complete Tool kit of Taparia/Jhalani/Stanley Equivalent with other mechanical Equipment’s- The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Taparia/ equivalent reputed make: 1. Double ended Spanner of Size (6/7 to 30/32) =01 complete set) 2. Ring Spanner Set of Size (12/13 to 30/32) =01 complete set) 3. Grip locking plier 250mm =01 no 4. circlip plier internal straight 85-165mm =01 no 5. side cutting plier 165mm =01 no 6. combination plier 210mm =01 no 7. long nose plier 165mm = 01 no 8. Insulated Screw Driver 12 inch/ 8 Inch/ 6 Inch/ 4 inch=01 No. Each 9. Ball pein hammer 500 and 800 grams =01no each 10. screw drivers Philips tip pattern 6x150-6x250mm =01 no each 11. pipe wrench of 250mm& 300mm each HD = 1no each 12. Bearing puller (sizes 6’’ & 8’’) =01 no. each 13. Spirit level (600mm): 01 No. 14. Digital Clamp Meter (400A AC range/ 1000V/ LCD 7 segment display): 01 No. (Meco/Rishabh/ Fluke make) 15. Vernier Caliper (Digital display 0-150mm) :01 No. (Freemans/ Mitutoyo/ Insize/ equivalent reputed) 16. Digital Altimeter (Range: 0-8000 Mtr,) Make: BARIGO / HTC=01 No. 17. Cantilever Tool Box (205x200x450) =01 no 18. Hack saw frame 300mm with 12 No double sided 25mm blades = 1set 19. Torque wrench ratchet type Professional range with up to 160Lb-ft =01 no 20. Measuring tape steel 3 mtrs =01 no 21. Wire brush =02 no 22. Half round file with handle 250mm =01 no 23. Grease gun 450cc lever type=01 no. 24. flat file with handle 250mm ((Bastard/2nd cut and smooth) =01 no each 25. Half round file with handle 250mm (Bastard/2nd cut and smooth) =01 no each 26. Allen keys (Black Finish) 8mm to 24mm= 01 set 27. 8 lever 65mm round brass body padlock =2 no 28. Plastic Jerry can 50Ltrs =2no 29. 27 Pcs square drive Bi-Hex socket set complete with 22 Sockets (10mm to 34mm) and 5 Accessories (extension bar 1753,1763, universal joint 1773, T handle 1733, Reversible ratchet 1715). 30. L-handle 450mm =01 no 31. C-clamp 150mm=01 no 32. center punches 125&150mm = 1no each 33. soft face mallet hammer with handle (30mm) = 1no Bush grass cutter 1.47Kw 2 stroke air cooled bush cutter

1

58000

58000

... More
Channels Supply of two no channels fabricated out of ISMC 100 duly coated with antirust primer and paint for helping in shifting of electro- mechanical items in load carrier during breakdown of items in future

1

4600

4600

... More
FLAP VALVE Fabrication, installation, testing & commissioning of M.S flap valve of 500 mm Dia fabricated out of M.S flat plate and thickness of flap plate shall be 16mm. The job includes the charge of hinge, nuts, bolts, washer, D.G set, Welding set, highly skilled labors, and other tools & tackles for the completion of work. It also includes applying red oxide primer & then applying two coats of silver paint of reputed make.

1

25000

25000

... More
AIR RELEASE VALVE Supply, installation, testing and commissioning of Ductile iron single chamber double orifice triple function air release valve. Air valves shall be Single Chamber and Double Orifice type. The construction should be such, that the small and large orifice should be housed in the single chamber. A bouyant rigid float shall be of cylindrical shape and spehrical float shall not be permitted.The small orifice with float shall be capable of discharging small / micro air bubbles during operation under internal pressures.The valve shall exhaust air from pipework automatically when the pipeline is being filled. The valve shall be capable of allowing ingress of air when the pipeline is being emptied. The valve shall be capable of releasing air accumulating during the normal working of the pipeline.The seating and float shall be so designed to avoid the float sticking after a long period of staying in closed position.Air valve shall be constructed in such a manner so that the internal working parts which may be necessary for repairs shall be readily accessible, removable, and replaceable without use of special tools or remvoing the valve from the pipeline. No machining and welding of the parts shall be allowed for repairing. Internals should be interchangeable for the same size.All Ductile Iron parts like Body and Cover shall be Powder Epoxy coated both internally and externally. Valves shall have nominal diamter of DN100 with working pressure for air valves shall be not less than PN16 conforming to IS 14845: 2000 read with lattest ammendments. The job Further Includes providing and fitting of companion flange along with nuts bolts and gasket compete as per site requirements. Acceptable makes: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/ Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar. Materials of Construction Body and Cover: Ductile Iron as per EN-JS-1050 Float: SS as per IS3444 Internal Linkages: SS as per IS3444 Seat Ring: EPDM nitrile rubber Bolts & washer: Stainless Steel as per IS6603 Pressure Rating: PN-1.6 Hydrostatic Test: Body=24 Kg/Cm2: Seat= 16 Kg/Cm2

5

40000

200000

... More
WASH OUT: Supply, installation, testing and commissioning of 100 mm diameter Ductile Cast Iron metal non rising type Resilient seated Double Flange Sluice valve with body & bonnet of Ductile cast iron The valve face to face dimension as per BS 5163:1989/IS 14846:2000/DIN 3202 F4 and flange drilling as per IS: 1538. The valves shall be FBE coated both inside and outside with pocket less body passage. Material of Construction Body: Ductile Cast Iron of grade GGG40 (IS1865 / EN JS 1050 Gr. 400/15) Wedge: Ductile Cast Iron of grade GGG40, (IS1865/ EN JS 1050 Gr. 400/15) fully vulcanized with EPDM rubber Stem: Stainless Steel AISI: 410(min 13% Cr.) as per IS6603 or ASTM/276 or IS 1570 Stem Nut: LTB2 high tensile Brass Bonnet Gasket: EPDM rubber/Neoprene rubber Stem Sealing: O-rings of NBR Surface Protection: Epoxy coating. Pressure rating: 1.6 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar. The scope of work shall also include the following: 1. Fabrication, Providing and fitting of 02 No. or more additional M.S flanges to the 100 mm diameter wash out arrangement. Adequate stiffeners/ cleats shall be provided for strengthening of the flanges with pipe. The flange holes shall be drilled as per IS 1538 and shall be perfectly adaptable to the inbuilt flanges of Sluice Valve. 2. Fabrication, Providing and fitting of 5.4 mm thick 100 mm diameter M.S pipe up to 05-meter length or as per site requirements for its installation in the wash out job includes cost on account cutting hole in rising main, handling, cutting, welding, grinding etc. Painting of complete wash out arrangement by application of one coat of red Oxide Metal Primer followed by two coat of enamel paint to pipe, dismantling joint, flanges etc. of desired shades.

3

33000

99000

... More
FASD starter with ATS Manufacturing, Providing, installation, testing at site & commissioning of 300 HP capacity fully automatic auto transformer starter. The Starter shall be of following specifications and shall compromise of equipment’s detailed below: Specifications: a. Main contractor assembly having a range of 500 A L&T/ABB/Schnider/Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. b. Delta contractor assembly having a range of 400 A L& T/ABB/SChnider Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. c. Star contractor assembly having a range of 115A, L&T/ ABB/Schnider Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. d. Thermal overload relay of suitable capacity MN series of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. e. Motor protection relay of suitable capacity MN series of L&T/ ABB / Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. f. Double timer assembly (electro pneumatic) having a range of 0-60 second of L& T /ABB / Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. g. Single phase preventer of suitable capacity with selectable under & over voltage of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. h. Control MCB of suitable capacity amperes range. i. Electrolytic copper bus bar strips of suitable size & capacity duly tinned air insulated and mounted on suitable Bakelite insulation j. One number Digital voltmeter0-500V & one no. Ammeter digital type along with 3 No. CT coils having range 0- 500A fitted in each bus bar.Make L&T/ABB/AE/EE make. k. ON/OFF LED push button type RED & Green color of 5A-415V, 50HZ, L&T/ABB/Equivalent make. l. Frequency Meter, C.T coils and other accessories as per requirement/Design should be included. m. Complete internal wiring of the control panel for operating equipment by using adequate capacity single core copper wire of Havells/polycab/equivalent make. The wiring shall be fitted with plastic washers for identification of each wire at various joints. n. Panel for housing of all the equipment fabricated out 14 SWG gauge sheet metal of adequate size to house all the equipment with enough space to reach out to any equipment for repair/replacement. The panel shall have hinged door at the front with proper locking arrangements. The housing shall be provided with a base frame fabricated out of ISMC & welded /bolted at the bottom. The housing shall be provided with necessary cut out spaces for fitment of meters, push buttons actuator incoming & out coming connections. The panel shall be free standing, floor mounted, totally enclosed, vermin proof, spray enamel panted in two coats of conventional shade over a coat of red oxide primer both externally & internally. The panel shall have air vents for proper ventilation. Auto Transformer coil shall be made out of 1st class electrolytic copper strips having suitable capacity for the above starter. The coil shall be provided with F class insulation tape.The coil shall have tapings taken out at 50%, 65% and 80% The Core of the auto transformer shall be fabricated out of 1st class silicon 90 grade pota sheets cut to size and then tightening of the same adequately. The auto-transformer tank shall be fabricated out of MS sheet of suitable thinness to make the tank leak proof. which shall have a lid at the top provided with holes for tightening the same of the tank. The tank shall have to be painted in two coats of red oxide primer. The job includes providing and fitting of high-grade low viscosity transformer oil of reputed make up to the required level in the tank so that the auto-transformer coils get fully immersed. Adequate capacity electrolytic copper bus strips or cables shall be fitted for internal connections. The tank shall have to be fitted at back side of the starter

3

316000

948000

... More
MAIN CONTROL PANEL. Manufacturing, providing, installation, testing & commissioning of 1000 A 3 Phase LT Main control panel. The panel shall be of following specifications & shall compromise of the equipment detailed below: The LT panel shall be totally enclosed free standing type sheet metal enclosed dust and vermin proof, indoor type fabricated out of 14-gauge sheet and shall be suitable to work on 415+ 10% volts, 50 HZ, and three phase AC supply. The panel shall compromise of one incoming and three independently out going compartments for three pumping units and one auxiliary compartments for local load, panel must be confirming to relevant ISS/BSS codes. Incoming feeder panel shall consist of 1000A incommer,3 No. outgoing feeders and an auxiliary feeder. INCOMMING FEEDER: One No. incoming feeder consisting of TPN air insulated 1000A Copper bus bar arrangement. The incoming feeder shall house one no. 1000Amp draw out type manually operated ACB. 1000A draw out type manually operated ACB should be suitable to operate at 415 V AC having high mechanical and electrical operating life, protection through thermal – magnetic and microprocessor releases, inbuilt thermal memory, protection releases conform to EMI /EMC standard, self-diagnostic microprocessor-based releases with on–load testing through test button of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. Four air insulated copper bus bar of suitable Amps. One 0- 1000 Amp 96 mm sq flash arrestor pattern industrial types CT operated digital ampere meter to register the phase current. 0-500 Volts voltmeter 96 mm sq digital flash arrestor pattern industrial types CT operated digital volt meter to register the phase voltage. three phase four wire unbalanced load dynamic meter type CT operated power factor meter. Digital frequency meter, selector switches, copper wiring & other accessories as per requirement /design should be included. Three no 240–600-volt neon indicating lamps. OUTGOING FEEDER: Three 400 Amp MCCB with enclosure and having breaking capacity 50 KA at 415 V. The MCCB should shall be three pole and having adjustable thermal & magnetic setting & shall be of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. Three air insulated copper bus bar of suitable Amps One 0- 400 Amp 96 mm sq flush type pattern industrial types CT operated digital ampere meter to register the phase current. One 0-500 Volts voltmeter 96 mm sq flash arrestor pattern industrial types CT operated digital meter to register the phase voltage One hour meter to register the individual working of each pumping unit capable to register 10000 working hours. Three no 240–500-volt neon indicating lamps. AUXILLIARY FEEDER: One 100Amp MCCB with enclosure and having breaking capacity 50 KA at 415 V. The MCCB should shall be four pole and having adjustable thermal & magnetic setting & shall be of a. L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. Four air insulated copper bus bar of suitable Amp One 0- 200 Amp 96 mm sq flash arrestor pattern industrial types CT operated digital ampere meter to register the phase current. 0-200Volts voltmeter 96 mm sq flash arrestor pattern industrial types CT operated digital meter to register the phase voltage. Three no 240–500-volt neon indicating lamp Note: The job also includes the charge of proper earthing with G.I strip to Main control panel at site. Control Panel should be fully inbuilt with all devices for smooth operation of 3 No. pumping units with 270HP Prime mover 2 No. working simultaneously.

1

550000

550000

... More
VOLTAGE STABILIZERS Supply, installation, testing and commissioning at site 400 KVA Capacity Copper wound Voltage stabilizer. The stabilizer shall be manually operated, oil cooled suitable for working on 3 phase 50+ 3% Hz AC voltage. The core shall be contained in a box type container made out of 3 mm thick Mild Steel plate and painted in two coats of steel primer both inside and outside and with two coats of super enamel paint of grey shade (Spray paint) from outside the tank. The box shall be provided with suitable cooling pipes/ radiator fins to dissipate the heat generated and hooks of proper size for lifting. Wheels shall be provided at bottom for easy shifting/ positioning as and when required. Copper strips of suitable size shall be used for winding and fibre glass insulating material shall be used for insulating of copper strips. The core of the stabilizer shall be fabricated out of first-class silicon 92 grade pota sheets cut to the size and then tightened securely. The stabilizer shall have suitable insulated lugs of appropriate size of cable connection. The indicating glass of the transformer oil shall also be provided on the stabilizer body. Voltage Range Input = 160-460 volts Output = 400 + 3% volts Tap Changer = Manually Operated Balance type tap changer of 6 tapings with tap position Indicator. Tap No: - 1 = Step down by not more than 50 volts. Tap No: - 2 = line voltage. Tap No:- 3-6 =These taps shall be used to increase voltage in the range of 160-400V The stabilizer shall be provided with a free-standing type control panel made out of sheet metal dust and vermin proof internally wired having following accessories. Two number voltmeter 96mm2dial flush pattern type 0-500 volts, one each on incoming and outgoing circuits. The voltmeter shall be with fuse and selector switch for 3-phase. A set of indicating lamps for 3-phase complete with fusing both in primary and secondary side of the transformer. Red and green lamps for OFF/On display. The stabilizer shall be filled with transformer oil for reputed make up to the required level. All the accessories and meters shall be of reputed makes and shall conform to relevant ISI standards.

1

450000

450000

... More
CABLES

-

-

-

... More
Supply, installation, testing & commissioning of 150 sq mm PVC insulated double sheathed Armored copper cable to be laid from main control panel to voltage stabilizer to starter to motor. The cable shall be thimble at each end with copper thimble using a crimping tool and shall be laid through the cable duct to be provided by civil wing. The cable shall be of following specification Voltage: 1100V Insulation: PVC double sheathed Make of cable: Gloster/Havells/Finolex/National/ Reputed make Thimble: Dowell Make

200

3800

760000

... More
Supply, installation, testing & commissioning of 300 sq mm. PVC insulated armored aluminum cable single core to be laid from distribution transformer to main control panel The cable shall be thimble at each end with Dowell make thimble. The cable shall be of following specification: Voltage: 1100V Insulation: PVC double sheathed Make of cable: Gloster/Havells/Finolex/National Thimble: Dowell Make.

100

895

89500

... More
APFC PANEL Providing, fitting, testing and commissioning of APFC panel. Specifications of APFC panel: • Rating of APFC Panel: 220kVAr with Auto & manual switching • Frequency: 50 Hz • No. of Phases: 3 • Enclosure details: o Free Standing, Floor mounted, Indoor application o Material: CRCA o Thickness of Sheet Steel Used: Frame/ door(s) -2.0 mm o Protection: IP-42 or higher o The panel shall be supported with suitable section base frame at bottom. o Adequate lifting facilities shall be provided. o Earthing: The panel shall be provided with earthing terminals. o Painting: Powder coated shade Siemens grey • Bus-bar Detail o Material: Aluminium bus bar system of electrolytic grade suitable for the short time rating of 35kA for 1 sec o Busbar support: SMC Insulation • APFC Relay o Microprocessor based 1No. 8-step (Schneider/ L&T/ Meher/ BELUK) • Switchgear o Incomer: MCCB3P 400A 50kA breaking capacity -1 No. (L&T/ABB/Schneider) o Outgoing steps - Contactors (capacitor duty) (L&T/ ABB/ Schneider) & MCBs/ fuses • Capacitors o Type: Standard Duty (L&T/ABB/Schneider) • Allied instrumentation o Analog Ammeter with CTs (0-400A): 1 No. (Rishab/ C&S/ AE) o Analog Voltmeter with CTs (0-500V): 1 No. (Rishab/ C&S/AE) o Ammeter SS/ Voltmeter SS: 01 Each (Salzer/ L&T Teknic/ C&S/Rishab) o Auto/ Off/ Manual Switch 1 No. o Phase Indicating Lamps: 3 Nos. o External Current Transformer: 3 Nos. tape wound type shall be capable of withstanding the rated fault current of the system for 1 second (L&T/ RECISE/ KALPA/ AE/ Rishabh) o Timer/s: ON Delay (GIC/ other reputed make) o Outgoing feeder Indicating Lamps (ON/OFF) 3 Nos. each (L&T/Esbee/Teknic/ C&S) Technical Features of Switchgear Components 1. Low voltage MPP Capacitors o Type: The capacitor element shall comprise of self-healing, metallized polypropylene film having internal fuse to limit pressure in the container. o Standard: The capacitors shall conform to IS 13340 o Rated Voltage:440 V o Rated frequency: 50 Hz with a frequency variation of ± 5% o Number of Phases: 3 Phz o Temperature category: Upto 50°C 2. Contactors: The contactors shall be of capacitor duty with special inrush current limiting arrangement suitable for kVAr rating. Maximum inrush current at any step shall be 3-4 times the rated current. Contactor coil shall operate satisfactorily between 85% to 110% and drop out at less than 60%. 3.Automatic Power Factor Correction Relay: The panel shall be provided with Microprocessor based APFC relay having steps with facility for setting target PF range in the form of high and low step indication, low current indication and auto-manual selection. LED display shall be provided to indicate existing power factor. The relay should also provide overvoltage protection up to 10%of rated voltage and lead power factors eliminated. 4. Control wiring: Suitable control wiring shall be provided as per requirement with ferrule numbers numbered for ease in connection. Control circuit shall have protection fuses/ MCBs 5. Power cabling: Suitable sized aluminum unarmored power cable (Finolex/ KEI/ Polycab/ Gloster/ Havells) with lugs shall be provided to connect the capacitance with load.

1

257000

257000

... More
INSULATING MATS Providing and laying at site of high Voltage synthetic insulating mats as floor covering around Electro-mechanical gadgets for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications: • Confirming to IS -15652-2006 with latest amendments • Thickness- 2.5mm • Width – 1 Mtr • Length 2 Mtr • Anti- skid Type • Material- PVC Elastomer • Application: suitable for both AC and DC Electric installations. • Class – B • Colour- Black/RED/ Orange/Blue Acceptable make- Safe volt/Dozz/Zenith/ equivalent The mats besides above shall be moisture proof, fire retardant, no adverse effect of acid, alkalis, diesel oil and T oil and is to be fixed with floor

6

2500

15000

... More
LADDER/FIRE EXTUINGSHERS/MISC ITEMS

-

-

-

... More
Supply of heavy duty 5.5 mtr/ 18 feet compact and foldable telescopic ladder having load bearing capacity 150 kg of reputed make

1

15000

15000

... More
Supply of Fire extinguisher ABC powder type of 6 kg capacity with following feature 1) IS certified as per IS 15683 of 2006 2) Operating temperature 0 to 55 degrees complete in all respects suitable for dousing fires particularly Electrical fires. Wall hook and discharge pipe shall be supplied along with cylinder

4

2850

11400

... More
Providing and fitting of 1.5 sq. mm PVC insulated Copper wire of reputed approved make

180

25

4500

... More
Providing and fitting of PVC channel 1" size along with bend connections and other supports, square blocks, etc.

350

10

3500

... More
Providing and fitting of angle holders with ceiling rose for operator’s room.

6

35

210

... More
Providing and fitting of 5W LED bulbs (Philips/ Eveready/ Syska make)

6

140

840

... More
Providing and fitting of 70W LED area lighting assembly at specified locations of IP 66 8400 Lumen with test certificate (Philips/ Everyday/Syska)

10

6900

69000

... More
Providing and fitting of switches (Anchor/ SSK) - 06A rating

10

25

250

... More
Providing and fitting of lighting indicator (Anchor/ SSK) - 06A rating

2

69

138

... More
Providing and fitting of fan regulator with rotary steps (SSK/ Anchor)

1

300

300

... More
Providing and fitting of 5-pin socket (SSK/ Anchor)

3

80

240

... More
Surface mounted Enclosing box for switches (Topsun/ Anchor)

3

100

300

... More
Providing and fitting of 2.5 sq. mm PVC insulated Copper wire for heating (Havells/ Anchor/ Polycab/ Finolex)

45

39

1755

... More
Providing and fitting of SS combine box type at specified heating points. (Anchor/ SSK)

2

180

360

... More
Providing and fitting MCB 6A of Anchor / L&T /equivalent for lighting circuits

4

200

800

... More
Providing and fitting MCB 20A DP (Anchor / L&T /equivalent) for heating circuit

2

600

1200

... More
Providing and fitting of 12-way MCB end box (Benlo/ Anchor/ Havells/ SSK/ HPL)

1

1600

1600

... More
Providing of Korean blanket of size (260cm x 240 Cm) of ultra soft and cozy double type for workers deputed at site

3

1750

5250

... More
Providing of 1000-watt Havells walthero carbon room heater or equivalent make and model for workers deputed at site to use it during winter season.

1

4700

4700

... More
Providing of rechargeable 10W LED torch of havells/Ands light/equivalent make for workers deputed at site

3

1500

4500

... More
Providing, fitting, and testing of ceiling/corner fan “Havells/Orient/Bajaj” equivalent make having sweep of 1200mm (48”). working on 230V, 50Hz, 1ǿ A.C.

1

1800

1800

... More
Providing of plastic chair of following specification for site Make = cello/Neelkamal/Equivalent make Maximum load capacity = 150 Kg Finish Type = Glossy Material = Plastic Width = 57.5 cm Height = 88.5cm Weight = 3.3 Kg Seat Height = 320 mm

4

1300

5200

... More
Providing and fitting of 5KVA fully automatic voltage stabilizer ranging from 90-300 Volts giving output voltage of 200-230 Volts. The job also includes P/F of 12-volt DC battery 150 AH (Exide) along with 950 VA sine wave Inverter (Microtek/ APC/ Sukam make) along with leads terminals and necessary wiring complete in all respects.

1

38000

38000

... More
CREATION OF 630 KVA SUBSTATION H- FRAME a. Fabrication, supply, installation, testing & commissioning of 09 Mtr long M.S steel tubular poles (410 SP33) ... with base plate of 300x300x5mm size fitted at the bottom for grouting. (pit depth = 1.35 Mtr) = 02 no b. Providing and laying of cement bottoming of ST poles in ratio 1:2:4 as per Standard one cum/pole= 02 job c. Providing and painting of one coat of red oxide paint and two coat of aluminum paint (01 Liter /pole)= 02 jobs d. Providing and fitting of heavy duty 11kV GOAB Switch 200A 3 Pole of reputed make= 01 set e. Providing and fitting of heavy duty 11kV horn gap fuse set of reputed make= 01 set f. Providing and fitting of heavy-duty polymeric type Disc insulators 12Kv----1 set g. Supply and errection of nonlinear resistor type lighting arrestor set (Set of 03 No’s) suitable for three wire, 11kv overhead lines with rated voltage 9V rms with a nominal discharge current rating of 5A and complete with nuts bolts and washers. h. Earthing with G.I earth plate 600x600x6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and 20 mm dia G.I watering pipe 2.7 mtr long funnel etc with charcoal/coke and salt required for complete earthing of substation. i. Supply, installation, testing of G.I ISMC 75 channel with clamps, nuts & bolts, washers = 150kg j. Providing and fitting 0.3 ACSR for the completion of work = 40 Mtr k. Providing and fitting of 11 KV pin insulator heavy duty type with nuts/bolts & washers of reputed make= 06 no l. Galvanized stay with 50x8mm Stay clamps, Guy insulators 2 No’s with all accessories complete set 2 No’s m. Wedge connector/PG Clams =6 No’s n. Anti climbing wire =15 Kgs o. Providing and fitting of danger plate= 02 no

1

161000

161000

... More
Earthing/Signage/Retrofitting

-

-

-

... More
Earthing Complete earthing of electrical motors, distribution panel, APFC panel, voltage stabilizers, etc. with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

3

7472

22416

... More
GI strip for earthing Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

40

144

5760

... More
Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue color background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts and nuts @ 300mm c/c all along the periphery as well as in two vertical rows along with theft resistant measures including the cost of painting with two or more coats of epoxy paint in grey color on the back side of aluminum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawing, specification and direction of Engineer-in-charge (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).

3.71

6396

23729.16

... More
Retrofitting of departmentally available 630KVA HT/LT Transformer and 2NO. 400Kva Voltage stabilizers shall include filtration of Toil and topping them up with 210Ltrs fresh T oil. Painting the equipment with suitable enamel paint after pretreatment of existing paint. Job includes shifting and fitting the equipment at site as per instruction of site engineer. It shall be mandatory to carry out the third-party inspection of all electro mechanical gadgets including control valves through the reputed/ registered third party inspection agency (EIL/CEIL/RTES). Regarding the manufacturing works carried out at site i.e. Fabrication, installation of suction pipes, delivery manifold, working plat form, sump gantry, internal gantry etc., The material shall bear the manufacturers test certificate of reputed/ registered manufacturers confirming to relevant IS specifications which shall be checked at site before installation.

1

66000

66000

... More
PUMPING UNIT Supply, installation, testing and commissioning of Centrifugal Horizontal Split Casing pumping unit 05 Cusec 108 Meters dynamic head along with motor and allied accessories for Lift Irrigation scheme LIS Gantamulla Stage 2nd of MISD Baramulla…...as per specification laid in appendix “B” and “C” and other Terms and conditions laid in eNIT.

2

2300000

4600000

... More
M.S Rising Main Fabrication, Providing, installation, testing and Commissioning of 400mm Nominal Diameter ERW ISI mark 6.3mm thick M.S Rising main to be laid from RD 0 to 1100 Mtr at lift irrigation scheme Gantamulla Stage 1st. The job requires involvement of highly skilled professionals for carrying out laying and welding jobs. The pipe shall be welded end to end using high quality electrodes by a D.C welding machine for the completion of work. The job includes charge of earth excavation in all types of soil with the help of JCB & Manual labors in high terrain wherever required for laying of pipe. The job includes cost on account of hiring D.G set, welding set, gas cutter, superior quality electrodes, dewatering pumps etc. for the completion of work. The job also includes fabrication of offsets/bends wherever necessary for proper alignment. The pipe shall have to be provided with two coats of anti-corrosive bitumastic paint. SPECIFICATIONS: Nominal diameter of pipe: 400 mm Outer Diameter : 406.4 mm Thickness of pipe : 6.3 mm Length of each pipe: pipe shall be in single random length from 4 -7Mtr as per clause 12.4 of IS 3589. Type of Welding: ERW Type. Quality of M.S plate to be used for manufacture: As per IS 2062(Grade Fe410) Pipe to be Manufactured: As per IS 3589 having one longitudinal joint with latest amendments Hydraulic test Pressure: As per 10.1 of IS3589 End Preparation: As per 17.1 of IS 3589 where V Groove is to be made by machine grinding edges of the pipe. Type of Welding to be used for joining pipes: D.C arc Welding. Tolerance: As per IS 3589 The installation shall have to be carried out in accordance with IS 10804

1100

7200

7920000

... More
SUCTION SYSTEM Supply, installation, laying and handling of suction side flanged pipeline out of 300 mm dia., 5.6mm thick MS pipe which includes the charge of fabrication of long radius mitered bends, welding work, nuts & bolts, washers etc. for the completion of work and. . SPECIFICATIONS: Nominal diameter of pipe= 300 mm Outer Diameter = 323.9 mm Thickness of pipe = 5.6 mm Length of each pipe = 4 -7Mtr Type of Welding = ERW Type Quality of M.S plate to be used for manufacture = As per IS 2062(Fe410) Pipe to be Manufactured = As per IS 3589 having one longitudinal joint with latest amendments Type of Welding = D.C arc Welding. Tolerance =As per IS3589. The job includes Supply, installation, testing of 300 mm Nominal dia. M.S flanges having thickness 16 mm/ AS PER IS:6392 as per site for suction system with nuts, bolts, washers & allied works (16 No’s)

22

7570

166540

... More
FOOT VALVE Providing, Fitting, Testing and Commissioning of Swing type flanged CI Foot valve of 300mm generally conforming to IS: 4038 along with the strainer and complete with allied accessories and auxiliaries. Note: Test Certificate is to be provided.

2

54500

109000

... More
ECCENTRIC REDUCER Manufacturing, Providing and installation of eccentric reducer 300mm X nominal suction nozzle of the pump provided and 500mm long fabricated out of 8mm thick MS plate duly flanged on both sides. The flanges fitted to reducer must be as 16mm thick/with holes and pitch as per IS IS:6392 AND MUST HAVE MATCHING NO. OF HOLES WITH PUMP NOZZLE/SUCTION FLANGES, THE JOB IS INCLUSIVE OF PROVIDING FITTING OF SUITABLE SIZE NUTS BOLTS AND WASHERS AND PAINTING IN ONE COAT OF STEEL PRIMER FOLLOWED BY TWO COATS OF BITUMINOUS PAINT.

2

10200

20400

... More
CONCENTRIC INCREASER Manufacturing, Providing and installation of concentric increaser (nominal Discharge nozzle of the pump provided) X 300mm and 500mm long fabricated out of 8mm thick MS plate duly flanged on both sides. The flanges fitted to increaser must be as per Table 17 of IS: 6392 AND MUST HAVE MATCHING NO. OF HOLES WITH PUMP NOZZLE/DISCHARGE FLANGES, THE JOB IS INCLUSIVE OF PROVIDING FITTING OF SUITABLE SIZE NUTS BOLTS AND WASHERS AND PAINTING IN ONE COAT OF STEEL PRIMER FOLLOWED BY

2

12500

25000

... More
PRIMING PUMP Supply, installation, testing and commissioning of submersible horizontal non clog priming pump unit capable of handling highly turbid river water. The pump shall have following specifications: Type: horizontal, submersible, non-clog Head: 10 Mtrs Phase: 1 phase Discharge: 300-350 liters /Min Power: suitable or above parameters Speed 2900(synchronous) Voltage: 220 +/-10%% V Motor rating 02 HP The job shall include providing /fitting of all the G.I/ MS Black pipes 50 mm NB C-class (Approx. = 12 mtrs.) as per the out let of the priming pump and fittings like DI 50 mm NRV, 3 NO SS ball valves, Nipples, flanges/sockets, Tees, Elbows/Bends, & other allied fittings as required for priming of the two No. newly installed Pumping unit. Complete installation as required. The job also includes suitable capacity compact starter/ controller of reputed make and P/F of 3 core 10mm sq. Submersible cable -20 meter

1

68900

68900

... More
Reflux Valve Supply, installation, testing and commissioning of 300 mm Size Reflux Valve Resilient Seated Double Flanged Swing Check Valve (NRV) with by-pass arrangement and FBE Powder coating inside and outside color with Min. Coating thickness of 250 microns. Face to face dimensions as per EN 558-1/DIN 3202-F6/IS 5312 & Flange drilling as per IS1538/BIS 4504. The valve shall be complete with in-built bypass arrangement. Material of Construction Body, Cover: Ductile Cast Iron of grade GGG40(IS1865 Gr. 400/15) Disc: Ductile Cast Iron of grade GGG40, fully vulcanized with EPDM rubber Gasket: EPDM rubber Surface Protection: Epoxy Powder coating Reflux Valve Pressure Rating: P N: 1.6 Hydrostatic pressure: B o d y = 24 Kg/cm2 Seat= 16 Kg/cm2 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar.

2

146000

292000

... More
Double Flange Sluice valve Supply, installation, testing and commissioning of 300 mm Size Ductile Iron Resilient seated Double Flange Sluice valve with body & bonnet of ductile cast iron The valve face to face dimension as per BS 5163:1989/IS 14846:2000/DIN 3202 F4 and flange drilling as per IS: 1538. The valves shall be FBE coated both inside and outside with pocket less body passage. Material of Construction Body: Ductile Cast Iron of grade GGG40 (IS1865/ EN JS 1050 Gr. 400/15) Wedge: Ductile Cast Iron of grade GGG40, (IS1865/EN JS 1050 Gr. 400/15) fully vulcanized with EPDM rubber Stem: Stainless Steel AISI: 410(min 13% Cr.) as per IS6603 or ASTM/276 or IS 1570 Stem Nut: LTB2 high tensile Brass Bonnet Gasket: EPDM rubber/Neoprene rubber Stem Sealing: O-rings of NBR Surface Protection: Epoxy coating. Pressure rating: 1.6 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/TALIS Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar.

2

126000

252000

... More
400 mm Size Reflux Valve Supply, installation, testing and commissioning of 400 mm Size Reflux Valve Cast Iron as per IS5312:20024 Resilient seated Double Flanged Swing Check Valve (NRV) with by-pass arrangement and paint coating inside and outside suitable color with Min. Coating thickness of 250 microns. The valve shall be complete with in-built bypass arrangement. Material of Construction Body, Cover: Grey Cast Iron of grade FG200 Disc : Grey Cast Iron of grade FG200, fully vulcanized with EPDM rubber Gasket: EPDM rubber/ As per IS 5312 Surface Protection: As per IS 5312 Pressure Rating: P N: 1.6 Hydrostatic pressure: B o d y = 24 Kg/cm2 Seat= 16.0 Kg/cm2 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/TALIS Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar.

4

176500

706000

... More
Delivery Pipes and Manifold: 1. Delivery pipes-------------------18 Meter (Total length) Supply, installation, laying and handling of Delivery pipeline out of 300 mm Nominal dia.,6.3mm thick MS pipe which includes the charge of fabrication of offsets, welding work, nuts & bolts, washers etc for the completion of work and shall have following specifications: Nominal diameter of pipe= 300 mm Outer Diameter = 323.9 mm Thickness of pipe = 6.3 mm Length of each pipe = 4 -7Mtr Type of Welding = ERW Type Quality of M.S plate to be used for manufacture = As per IS 2062(Fe410) Pipe to be Manufactured= As per IS 3589 having one longitudinal joint with latest amendments Type of Welding = D.C arc Welding. Tolerance = As per clause 12.3 of IS 3589 2. Flanges Supply, installation, testing of 300 mm Nominal dia. M.S flanges having thickness 24 mm/ AS PER IS:6392 as per site requirement (10 no) for Manifold junction with nuts, bolts, washers & allied works 3. Manifold: Fabrication, Fitting, testing and commissioning of 400 mm Nominal Diameter delivery manifold for 02 No. 300mm nominal diameter deliveries of unit no. 1 & 2 and connecting it with 500mm nominal diameter rising main. The manifold is to be fabricated out of 500 mm Nominal diameter pipe 6.3mm thick with approximate 3.5 M in length by way of following: -  Horizontally placing the 3.5 Meter long 400mm Nominal diameter 6.3mm thick pipe to act as manifold body.  Cutting three holes of Nominal Dia of 323.9mm Holes at suitable distances from each other as per the alignment of delivery pipes and then connecting the ND 300mm pipes coming out from the Pump house to the manifold body through welding.  Cutting circular hole of size 406.4mm diameter approx in the manifold from Rising main side preferably at the middle of the manifold body or as per the alignment of rising main as per site conditions and then connecting the ND 400mm rising main through welding.  Fabrication providing and fitting of 393.8 mm diameter mild steel blinding plates (end caps) on both sides of common header. The end plates are to be fabricated out of 16 mm thick M.S Plate.  Providing and fitting of Compensated opening plates for additional enforcement to the riser opening and inlet openings of the Manifold. The details of the compensated opening plates shall be as follows Compensation Pads for discharge line connection pipes: Total No.’s to be used 2.00 NO. Outer Diameter 450 mm Inner Diameter 323.9 mm Thickness 16 mm Compensation Pad for pressure main: Outer Diameter 570 mm Inner Diameter 406.4 mm Thickness 16 mm 4. Painting of delivery manifold with fittings: - Providing & application of synthetic enamel paint to delivery manifold by the way of following: - a) Cleaning of metal surfaces by application of water, emery paper etc., to remove dirt, grease stains, rust etc. The job also includes removing of old loose paint. b) Applying of steel Priming coat c) Application of two coats of synthetic enamel paint to all surfaces by brushing or spraying method. All consumable items for cleaning/painting shall be in contractor’s scope Make of Paint: Asian /Nerolac/Berger The equipment to be painted and color shading/ sequence is as below: Equipment: Paint/Shade Common headers with riser outlets: Synthetic Enamel /Dark Grey Delivery Manifold pipes: Synthetic Enamel/Sky Blue

1

252000

252000

... More
Gantry Design, manufacture, supply, erection, & commissioning of 05-ton capacity with monorail and chain-pulley block suitable for handling a load of 05-ton capacity in both directions i.e., long-travel movement and cross-travel movement. Major components of the crane structure shall comprise of following items: a) RUNWAY GIRDERS: shall be fabricated out of ISMB 200, the girder beams shall be fitted on tie-plates of 300X300X6mm dimensions fitted on the wall with the embedded bolts & nuts. The upper flange of the runway girder shall be fitted with channel section ISMC 150. ISSQ 30mm shall be fitted on channel section by way of welding and then finishing along the length of runway girder to ensure smooth movement of bridge girders end carriages designed for long movement by means of manually driven gear & pulley mechanics. Length of each runway = 8Mtr (02no). b) END CARRIAGE: two no. end carriages shall be fabricated out of ISMC 200, suitably fitted with 250mm diameter MS wheels fitted with suitable bearings as per requirement and instruction of site engineer. A gear and pinion mechanism is also to be designed, fabricated and installed in such a way that both the end carriages run in synchronization with each other connected by means of a spindle of suitable diameter fitted with a pulley with endless chain to facilitate long travel movement of crane bridge manually throughout the machine floor. Suitable size and number of plumber blocks are also to be installed in the mechanism. c) BRIDGE GIRDER: The bridge girder shall be fabricated out of ISMB 350 for a span of 8Mtr. The bridge girder rests over the end carriage by means of M.S Plate of 300X 300 X 6mm dimensions with nuts & bolts. d) MONORAIL BLOCK: one unit of 05-ton capacity heavy duty monorail block of indef/globe/Elephant with ISI mark suitable to operate inside the pump house shall be mounted on the lower flange girder to facilitate the cross-travel movement. e) CHAIN PULLEY BLOCK MANUALLY OPERATED: one unit of 05-ton spur gear type capacity globe/indef/Elephant make shall be provided. Minimum hoist shall be 6.00 mtrs. The job also includes painting of entire structure with two coats of A grade enamel yellow paint after proper surface preparation and application of metal primer coat.

1

297000

297000

... More
DISMANTLING JOINT Fabrication, Providing, installation, testing and commissioning of 300 mm Nominal Diameter Mild Steel Slip on/dismantling joint in 300 mm dia. Delivery pipes. The body of the Dismantling joint shall be minimum 12 mm thick. The flanges shall be drilled as per IS:6392 and shall be 28mm thick (03 No.). The joint shall comply to a minimum expansion/contraction of 50 mm. The job also includes P/F of Nuts, Bolts, Packing, tie rods & Washers required for the completion of work.

2

38000

76000

... More
SLIP ON JOINT Fabrication, Providing, installation, testing and commissioning of 400 mm Nominal Diameter Mild Steel Slip on/dismantling joint in 400 mm dia. raising main. The body of the Dismantling joint shall be minimum 12 mm thick. The flanges shall be drilled as per IS:1538 and shall be 22mm thick (3 No.). The joint shall comply to a minimum expansion/contraction of 50 mm. The job also includes P/F of Nuts, Bolts, packing & Washers required for the completion of work.

4

52500

210000

... More
Tool Kit Supply of complete Tool kit of Taparia/Jhalani/Stanley Equivalent with other mechanical Equipment’s- The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Taparia/ equivalent reputed make: 1. Double ended Spanner of Size (6/7 to 30/32) =01 complete set) 2. Ring Spanner Set of Size (12/13 to 30/32) =01 complete set) 3. Grip locking plier 250mm =01 no 4. circlip plier internal straight 85-165mm =01 no 5. side cutting plier 165mm =01 no 6. combination plier 210mm =01 no 7. long nose plier 165mm = 01 no 8. Insulated Screw Driver 12 inch/ 8 Inch/ 6 Inch/ 4 inch=01 No. Each 9. Ball pein hammer 500 and 800 grams =01no each 10. screw drivers Philips tip pattern 6x150-6x250mm =01 no each 11. pipe wrench of 250mm& 300mm each HD = 1no each 12. Bearing puller (sizes 6’’ & 8’’) =01 no. each 13. Spirit level (600mm): 01 No. 14. Digital Clamp Meter (400A AC range/ 1000V/ LCD 7 segment display): 01 No. (Meco/Rishabh/ Fluke make) 15. Vernier Caliper (Digital display 0-150mm) :01 No. (Freemans/ Mitutoyo/ Insize/ equivalent reputed) 16. Digital Altimeter (Range: 0-8000 Mtr,) Make: BARIGO / HTC=01 No. 17. Cantilever Tool Box (205x200x450) =01 no 18. Hack saw frame 300mm with 12 No double sided 25mm blades = 1set 19. Torque wrench ratchet type Professional range with up to 160Lb-ft =01 no 20. Measuring tape steel 3 mtrs =01 no 21. Wire brush =02 no 22. Half round file with handle 250mm =01 no 23. Grease gun 450cc lever type=01 no. 24. flat file with handle 250mm ((Bastard/2nd cut and smooth) =01 no each 25. Half round file with handle 250mm (Bastard/2nd cut and smooth) =01 no each 26. Allen keys (Black Finish) 8mm to 24mm= 01 set 27. 8 lever 65mm round brass body padlock =2 no 28. Plastic Jerry can 50Ltrs =2no 29. 27 Pcs square drive Bi-Hex socket set complete with 22 Sockets (10mm to 34mm) and 5 Accessories (extension bar 1753,1763, universal joint 1773, T handle 1733, Reversible ratchet 1715). 30. L-handle 450mm =01 no 31. C-clamp 150mm=01 no 32. center punches 125&150mm = 1no each 33. soft face mallet hammer with handle (30mm) = 1no 34. 10mm Plunger dial gauge with resolution of 0.01mm and magnetic stand complete Mitutoyo or equivalent. (02 No’s) Bush grass cutter 1.47Kw 2 stroke air cooled bush cutter

1

61000

61000

... More
CHANNELS Supply of two no channels fabricated out of ISMC 100 duly coated with antirust primer and paint for helping in shifting of electro- mechanical items in load carrier during breakdown of items in future

1

4600

4600

... More
FLAP VALVE Fabrication, installation, testing & commissioning of M.S flap valve of 400 mm Dia fabricated out of M.S flat plate and thickness of flap plate shall be 22mm. The job includes the charge of hinge, nuts, bolts, washer, D.G set, Welding set, highly skilled labors, and other tools & tackles for the completion of work. It also includes applying red oxide primer & then applying two coats of silver paint of reputed make.

1

17500

17500

... More
AIR RELEASE VALVE Supply, installation, testing and commissioning of Ductile iron single chamber double orifice triple function air release valve. Air valves shall be Single Chamber and Double Orifice type. The construction should be such, that the small and large orifice should be housed in the single chamber. A bouyant rigid float shall be of cylindrical shape and spehrical float shall not be permitted.The small orifice with float shall be capable of discharging small / micro air bubbles during operation under internal pressures.The valve shall exhaust air from pipework automatically when the pipeline is being filled. The valve shall be capable of allowing ingress of air when the pipeline is being emptied. The valve shall be capable of releasing air accumulating during the normal working of the pipeline.The seating and float shall be so designed to avoid the float sticking after a long period of staying in closed position.Air valve shall be constructed in such a manner so that the internal working parts which may be necessary for repairs shall be readily accessible, removable, and replaceable without use of special tools or remvoing the valve from the pipeline. No machining and welding of the parts shall be allowed for repairing. Internals should be interchangeable for the same size.All Ductile Iron parts like Body and Cover shall be Powder Epoxy coated both internally and externally. Valves shall have nominal diamter of DN100 with working pressure for air valves shall be not less than PN16 conforming to IS 14845: 2000 read with lattest ammendments. The job Further Includes providing and fitting of companion flange along with nuts bolts and gasket compete as per site requirements. Acceptable makes: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/ Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar. Materials of Construction Body and Cover: Ductile Iron as per EN-GJS-400-15 Float: SS as per IS3444 Internal Linkages: SS as per IS3444 Seat Ring: EPDM nitrile rubber Bolts & washer: Stainless Steel as per IS6603 Pressure Rating: PN-1.6 Hydrostatic Test: Body=24 Kg/Cm2, Seat= 16 Kg/Cm2

6

40000

240000

... More
WASH OUT: Supply, installation, testing and commissioning of 100 mm diameter Ductile Cast Iron metal non rising type Resilient seated Double Flange Sluice valve with body & bonnet of Ductile cast iron The valve face to face dimension as per BS 5163:1989/IS 14846:2000/DIN 3202 F4 and flange drilling as per IS: 1538. The valves shall be FBE coated both inside and outside with pocket less body passage. Material of Construction Body: Ductile Cast Iron of grade GGG40 (IS1865 / EN JS 1050 Gr. 400/15) Wedge: Ductile Cast Iron of grade GGG40, (IS1865/ EN JS 1050 Gr. 400/15) fully vulcanized with EPDM rubber Stem: Stainless Steel AISI: 410(min 13% Cr.) as per IS6603 or ASTM/276 or IS 1570 Stem Nut: LTB2 high tensile Brass Bonnet Gasket: EPDM rubber/Neoprene rubber Stem Sealing: O-rings of NBR Surface Protection: Epoxy coating. Pressure rating: 1.6 Acceptable make: KIRLOSKER/ ADVANCE/ IVC/ SIGMAFLOW/ VAG/Equivalent As approved under EOI of SE mechanical Circle Kashmir I&FC Department Srinagar. The scope of work shall also include the following: 1. Fabrication, Providing and fitting of 02 No. or more additional M.S flanges to the 100 mm diameter wash out arrangement. Adequate stiffeners/ cleats shall be provided for strengthening of the flanges with pipe. The flange holes shall be drilled as per IS 1538 and shall be perfectly adaptable to the inbuilt flanges of Sluice Valve. 2. Fabrication, Providing and fitting of 5.4 mm thick 100 mm diameter M.S pipe up to 05-meter length or as per site requirements for its installation in the wash out job includes cost on account cutting hole in rising main, handling, cutting, welding, grinding etc. 3. Painting of complete wash out arrangement by application of one coat of red Oxide Metal Primer followed by two coat of enamel paint to pipe, dismantling joint, flanges etc. of desired shades.

4

33000

132000

... More
01 TON GANTRY Fabrication, providing. fitting and installation of 1-ton capacity sump gantry. The Job comprises of the following specifications process of fabrication and involvement of material: - a). Vertical supports: - Fabrication. providing and installation of gantry vertical supports (two Nos.) to be fabricated out of Mild steel angle iron of size 40x40x6mm the posts shall have to be fabricated as per drawing. The vertical posts shall b be fabricated in four pieces of angle iron having 5 Meters effective height and its strengthening /bracing by horizontal members to be placed after every 3’ and diagonal members as per requirement out of same angle section as used with the vertical members. The size of the angle Iron post shall be 24"x24" X10 mm at the bottom and 16"x16"x10mm at the top. The vertical angle iron posts shall be provided and welded with Mild steel plate having 10mm thickness welded at the bottom and top drilled with suitable diameter holes. The Bottom portion of the vertical posts shall be embedded into the cement concrete block of suitable size to be laid in the ratio of 1:2:4. The posts thus fabricated shall be erected at the two sides of the sump gantry. b). Gantry Beam: - Providing and fitting of main I beam (Horizontal) of size ISMB-200 having total length of 4 Mtrs shall also be fitted with Mild steel plate of the same size i.e., 12"x12".10mm thick, with nuts and bolts and welding as well. The job also includes providing and fitting of nuts and bolts for fixing of plates of the horizontal beam and vertical posts plates. The whole gantry structure shall be painted with one coat of steel primer. Mono rail chain pulley block: - Providing and fitting of 1 Ton Capacity travelling trolley of spur gear type and 1 Ton capacity chain pulley block having 6Mtrs lift. The chain pulley block and the travelling trolley shall be of reputed makes approved by the department.

1

152000

152000

... More
EXPANSION JOINT Fabrication, providing, fitting & testing 400 mm ND Mild Steel pipe expansion joint at specific spots to be identified by the site Engineer with longitudinal elongation up to 100mm approx. and nominal length of approximate 1000 mm to be fabricated out of 12 mm M.S plate duly rolled in perfect circular shape and turned to proper size. The job includes providing and fitting of matching MS flanges of nominal Dia 400 mm as per IS 6392 to be fitted to the Rising Main on both ends of joint. The flanged joints shall be made leak proof by way of insertion of rubber insertion cloth of superior quality and of suitable thickness The specifications are as under: - NO. I- Socket: -- The socket shall be fabricated out of MS plate of 12 mm thickness and offset ND as 400 mm, 425 mm each piece 150 mm long duly welded with each other. The 425mm central piece shall be turned and finished to proper size to accommodate the spigot with its easy movement of to and fro during expansion and contraction NO. II- Spigot The spigot shall be fabricated out of 12 mm thick MS plate duly rolled in perfectly having approx. length of 500 mm. This piece shall be turned to accurate size on the lathe machine to give easy movement during operation. NO.III- Gland - The gland shall be fabricated out of 12 mm MS plate having approx. length of 150 mm duly turned to mover over the spigot to make the packing material tight to avoid leakage. The Expansion joint is to be fitted on rising main by flanged connections. It shall be painted with two coats of Red Oxide Metal Primer followed by two coats of Black Bituminous paint. The job also includes providing and fitting of mating flanges, M.S fasteners, RI Cloth Washers/ Rubber Gaskets, etc. All flange dimensions shall be as per IS 6392 (Table 17).

3

70000

210000

... More
FASD starter with ATS Manufacturing, Providing, installation, testing at site & commissioning of 350 HP capacity fully automatic auto transformer starter. The Starter shall be of following specifications and shall compromise of equipment’s detailed below: Specifications: a. Main contractor assembly having a range of 630 A L&T/ABB/Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. b. Delta contractor assembly having a range of 400 A L& T/ABB/ Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. c. Star contractor assembly having a range of 185A, L&T/ ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. d. Thermal overload relay of suitable capacity MN series of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. e. Motor protection relay of suitable capacity MN series of L&T/ ABB / Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. f. Double timer assembly (electro pneumatic) having a range of 0-60 second of L& T /ABB / Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. g. Single phase preventer of suitable capacity with selectable under & over voltage of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. h. Control MCB of suitable capacity amperes range. i. Electrolytic copper bus bar strips of suitable size & capacity duly tinned air insulated and mounted on suitable Bakelite insulation j. One number Digital voltmeter0-500V & one no. Amperemeter digital type along with 3 No. CT coils having range 0- 600A fitted in each bus bar. Make L&T/ABB/AE/EE make. k. ON/OFF LED push button type RED & Green color of 5A-415V, 50HZ, L&T/ABB/Equivalent make. l. Frequency Meter, C.T coils and other accessories as per requirement/Design should be included. m. Complete internal wiring of the control panel for operating equipment by using adequate capacity single core copper wire of Havells/polycab/equivalent make. The wiring shall be fitted with plastic washers for identification of each wire at various joints. n. Panel for housing of all the equipment fabricated out 14 SWG gauge sheet metal of adequate size to house all the equipment with enough space to reach out to any equipment for repair/replacement. The panel shall have hinged door at the front with proper locking arrangements. The housing shall be provided with a base frame fabricated out of ISMC & welded /bolted at the bottom. The housing shall be provided with necessary cut out spaces for fitment of meters, push buttons actuator incoming & out coming connections. The panel shall be free standing, floor mounted, totally enclosed, vermin proof, spray enamel panted in two coats of conventional shade over a coat of red oxide primer both externally & internally. The panel shall have air vents for proper ventilation. Auto Transformer coil shall be made out of 1st class electrolytic copper strips having suitable capacity for the above starter. The coil shall be provided with F class insulation tape.The coil shall have tapings taken out at 50%, 65% and 80% The Core of the auto transformer shall be fabricated out of 1st class silicon 90 grade pota sheets cut to size and then tightening of the same adequately. The auto-transformer tank shall be fabricated out of MS sheet of suitable thinness to make the tank leak proof. which shall have a lid at the top provided with holes for tightening the same of the tank. The tank shall have to be painted in two coats of red oxide primer. The job includes providing and fitting of high-grade low viscosity transformer oil of reputed make up to the required level in the tank so that the auto-transformer coils get fully immersed. Adequate capacity electrolytic copper bus strips or cables shall be fitted for internal connections. The tank shall have to be fitted at back side of the starter

2

335000

670000

... More
MAIN CONTROL PANEL. Manufacturing, providing, installation, testing & commissioning of 800 A 3 Phase LT Main control panel. The panel shall be of following specifications & shall compromise of the equipment detailed below: The LT panel shall be totally enclosed free standing type sheet metal enclosed dust and vermin proof, indoor type fabricated out of 14-gauge sheet and shall be suitable to work on 415+ 10% volts, 50 HZ, and three phase AC supply. The panel shall compromise of one incoming and three independently out going compartments for three pumping units and one auxiliary compartments for local load, panel must be confirming to relevant ISS/BSS codes. Incoming feeder panel shall consist of 1000A incommer,3 No. outgoing feeders and an auxiliary feeder. INCOMMING FEEDER: One No. incoming feeder consisting of TPN air insulated 800A Copper bus bar arrangement. The incoming feeder shall house one no. 800Amp draw out type manually operated ACB. • 800A draw out type manually operated ACB should be suitable to operate at 415 V AC having high mechanical and electrical operating life, protection through thermal – magnetic and microprocessor releases, inbuilt thermal memory, protection releases conform to EMI /EMC standard, self-diagnostic microprocessor-based releases with on–load testing through test button of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. • Four air insulated copper bus bar of suitable Amps. • One 0- 600 Amp 96 mm sq flash arrestor pattern industrial types CT operated digital ampere meter to register the phase current. • 0-600 Volts voltmeter 96 mm sq digital flash arrestor pattern industrial types CT operated digital volt meter to register the phase voltage. • three phase four wire unbalanced load dynamic meter type • CT operated power factor meter. • Digital frequency meter, selector switches, copper wiring & other accessories as per requirement /design should be included. • Three no 240–600-volt neon indicating lamps. OUTGOING FEEDER: Two 630 Amp MCCB with enclosure and having breaking capacity 50 KA at 415 V. The MCCB should shall be three pole and having adjustable thermal & magnetic setting & shall be of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. • Three air insulated copper bus bar of suitable Amps • One 0- 600 Amp 96 mm sq flash arrestor pattern industrial types CT operated digital ampere meter to register the phase current. • One 0-600 Volts voltmeter 96 mm sq flash arrestor pattern industrial types CT operated digital meter to register the phase voltage • One hour meter to register the individual working of each pumping unit capable to register 10000 working hours. • Three no 240–600-volt neon indicating lamps. AUXILLIARY FEEDER: One 100 Amp MCCB with enclosure and having breaking capacity 50 KA at 415 V. The MCCB should shall be four pole and having adjustable thermal & magnetic setting & shall be of L&T/ABB Equivalent make as approved in EOI of SE mechanical circle Kashmir I&FC Department Srinagar. • Four air insulated copper bus bar of suitable Amp • One 0- 200 Amp 96 mm sq flash arrestor pattern industrial types CT operated digital ampere meter to register the phase current. • 0-200Volts voltmeter 96 mm sq flash arrestor pattern industrial types CT operated digital meter to register the phase voltage. • Three no 240–500-volt neon indicating lamp Note: The job also includes the charge of proper earthing with G.I strip to Main control panel at site. Control Panel should be fully inbuilt with all devices for smooth operation of 2 No. pumping units with 335HP Prime mover 1 No. working at a time.

1

440000

440000

... More
VOLTAGE STABILIZERS Supply, installation, testing and commissioning at site 500 KVA Capacity Copper wound Voltage stabilizer. The stabilizer shall be manually operated, oil cooled suitable for working on 3 phase 50+ 3% Hz AC voltage. The core shall be contained in a box type container made out of 3 mm thick Mild Steel plate and painted in two coats of steel primer both inside and outside and with two coats of super enamel paint of grey shade (Spray paint) from outside the tank. The box shall be provided with suitable cooling pipes/ radiator fins to dissipate the heat generated and hooks of proper size for lifting. Wheels shall be provided at bottom for easy shifting/ positioning as and when required. Copper strips of suitable size shall be used for winding and fibre glass insulating material shall be used for insulating of copper strips. The core of the stabilizer shall be fabricated out of first-class silicon 92 grade pota sheets cut to the size and then tightened securely. The stabilizer shall have suitable insulated lugs of appropriate size of cable connection. The indicating glass of the transformer oil shall also be provided on the stabilizer body. Voltage Range Input = 160-460 volts Output = 400 + 3% volts Tap Changer = Manually Operated Balance type tap changer of 6 tapings with tap position Indicator. Tap No: - 1 = Step down by not more than 50 volts. Tap No: - 2 = line voltage. Tap No: - 3-6 = These taps shall be used to increase voltage in the range of 160-400V The stabilizer shall be provided with a free-standing type control panel made out of sheet metal dust and vermin proof internally wired having following accessories. a). Two number voltmeter 96mm2dial flush pattern type 0-500 volts, one each on incoming and outgoing circuits. The voltmeter shall be with fuse and selector switch for 3-phase. b). A set of indicating lamps for 3-phase complete with fusing both in primary and secondary side of the transformer. c). Red and green lamps for OFF/On display. The stabilizer shall be filled with transformer oil for reputed make upto the required level. All the accessories and meters shall be of reputed makes and shall conform to relevant ISI standards.

2

550000

1100000

... More
CABLES Supply, installation, testing & commissioning of 150 sq mm PVC insulated double sheathed Armored copper cable to be laid from main control panel to voltage stabilizer to starter to motor. The cable shall be thimble at each end with copper thimble using a crimping tool and shall be laid through the cable duct to be provided by civil wing. The cable shall be of following specification Voltage: 1100V Insulation: PVC double sheathed Make of cable: Gloster/Havells/Finolex/National/ Reputed make Thimble: Dowell Make

150

3800

570000

... More
CABLES Supply, installation, testing & commissioning of 300 sq mm. PVC insulated armored aluminum cable single core to be laid from distribution transformer to main control panel The cable shall be thimble at each end with Dowell make thimble. The cable shall be of following specification: Voltage: 1100V Insulation: PVC double sheathed Make of cable: Gloster/Havells/Finolex/National Thimble: Dowell Make.

100

895

89500

... More
APFC PANEL Providing, fitting, testing and commissioning of APFC panel. Specifications of APFC panel: • Rating of APFC Panel: 140kVAr with Auto & manual switching • Frequency: 50 Hz • No. of Phases: 3 • Enclosure details: o Free Standing, Floor mounted, Indoor application o Material: CRCA o Thickness of Sheet Steel Used: Frame/ door(s) -2.0 mm o Protection: IP-42 or higher o The panel shall be supported with suitable section base frame at bottom. o Adequate lifting facilities shall be provided. o Earthing: The panel shall be provided with earthing terminals. o Painting: Powder coated shade Siemens grey • Bus-bar Detail o Material: Aluminium bus bar system of electrolytic grade suitable for the short time rating of 35kA for 1 sec o Busbar support: SMC Insulation • APFC Relay o Microprocessor based 1No. 8-step (Schneider/ L&T/ Meher/ BELUK) • Switchgear o Incomer: MCCB3P 250A 50kA breaking capacity -1 No. (L&T/ABB/Schneider) o Outgoing steps - Contactors (capacitor duty) (L&T/ ABB/ Schneider) & MCBs/ fuses • Capacitors o Type: Standard Duty (L&T/ABB/Schneider) • Allied instrumentation o Analog Ammeter with CTs (0-400A): 1 No. (Rishab/ C&S/ AE) o Analog Voltmeter with CTs (0-500V): 1 No. (Rishab/ C&S/AE) o Ammeter SS/ Voltmeter SS: 01 Each (Salzer/ L&T Teknic/ C&S/Rishab) o Auto/ Off/ Manual Switch 1 No. o Phase Indicating Lamps: 3 Nos. o External Current Transformer: 3 Nos. tape wound type shall be capable of withstanding the rated fault current of the system for 1 second (L&T/ RECISE/ KALPA/ AE/ Rishabh) o Timer/s: ON Delay (GIC/ other reputed make) o Outgoing feeder Indicating Lamps (ON/OFF) 3 Nos. each (L&T/Esbee/Teknic/ C&S) Technical Features of Switchgear Components 1. Low voltage MPP Capacitors o Type: The capacitor element shall comprise of self-healing, metallized polypropylene film having internal fuse to limit pressure in the container. o Standard: The capacitors shall conform to IS 13340 o Rated Voltage:440 V o Rated frequency: 50 Hz with a frequency variation of ± 5% o Number of Phases: 3 Phz o Temperature category: Upto 50°C 2. Contactors: The contactors shall be of capacitor duty with special inrush current limiting arrangement suitable for kVAr rating. Maximum inrush current at any step shall be 3-4 times the rated current. Contactor coil shall operate satisfactorily between 85% to 110% and drop out at less than 60%. 3.Automatic Power Factor Correction Relay: The panel shall be provided with Microprocessor based APFC relay having steps with facility for setting target PF range in the form of high and low step indication, low current indication and auto-manual selection. LED display shall be provided to indicate existing power factor. The relay should also provide overvoltage protection up to 10%of rated voltage and lead power factors completely eliminated. 4. Control wiring: Suitable control wiring shall be provided as per requirement with ferrule numbers numbered for ease in connection. Control circuit shall have protection fuses/ MCBs 5. Power cabling: Suitable sized aluminum unarmored power cable (Finolex/ KEI/ Polycab/ Gloster/ Havells) with lugs shall be provided to connect the capacitance with load.

2

181000

362000

... More
INSULATING MATS Providing and laying at site of high Voltage synthetic insulating mats as floor covering around Electro-mechanical gadgets for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications: • Confirming to IS -15652-2006 with latest amendments • Thickness- 2.5mm • Width – 1 Mtr • Length 2 Mtr • Anti- skid Type • Material- PVC Elastomer • Application: suitable for both AC and DC Electric installations. • Class – B • Colour- Black/RED/ Orange/Blue Acceptable make- Safe volt/Dozz/Zenith/ equivalent The mats besides above shall be moisture proof, fire retardant, no adverse effect of acid, alkalis, diesel oil and T oil and is to be fixed with floor

6

2500

15000

... More
LADDER/FIRE EXTUINGSHERS/MISC ITEMS Supply of heavy duty 5.5 mtr/ 18 feet compact and foldable telescopic ladder having load bearing capacity 150 kg of reputed make

1

15000

15000

... More
Supply of Fire extinguisher ABC powder type of 6 kg capacity with following feature 1) IS certified as per IS 15683 of 2006 2) Operating temperature 0 to 55 degrees complete in all respects suitable for dousing fires particularly Electrical fires. Wall hook and discharge pipe shall be supplied along with cylinder

4

2850

11400

... More
Providing and fitting of 1.5 sq. mm PVC insulated Copper wire of reputed approved make

180

25

4500

... More
Providing and fitting of PVC channel 1" size along with bend connections and other supports, square blocks, etc.

350

10

3500

... More
Providing and fitting of angle holders with ceiling rose for operator’s room.

6

35

210

... More
Providing and fitting of 5W LED bulbs (Philips/ Eveready/ Syska make)

6

140

840

... More
Providing and fitting of 70W LED area lighting assembly at specified locations of IP 66 8400 Lumen with test certificate (Philips/ Everyday/Syska)

10

6900

69000

... More
Providing and fitting of switches (Anchor/ SSK) - 06A rating

10

25

250

... More
Providing and fitting of lighting indicator (Anchor/ SSK) - 06A rating

2

69

138

... More
Providing and fitting of fan regulator with rotary steps (SSK/ Anchor)

1

300

300

... More
Providing and fitting of 5-pin socket (SSK/ Anchor)

3

80

240

... More
Surface mounted Enclosing box for switches (Topsun/ Anchor)

3

100

300

... More
Providing and fitting of 2.5 sq. mm PVC insulated Copper wire for heating (Havells/ Anchor/ Polycab/ Finolex)

45

39

1755

... More
Providing and fitting of SS combine box type at specified heating points. (Anchor/ SSK)

2

180

360

... More
Providing and fitting MCB 6A of Anchor / L&T /equivalent for lighting circuits

4

200

800

... More
Providing and fitting MCB 20A DP (Anchor / L&T /equivalent) for heating circuit

2

600

1200

... More
Providing and fitting of 12-way MCB end box (Benlo/ Anchor/ Havells/ SSK/ HPL)

1

1600

1600

... More
Providing of Korean blanket of size (260cm x 240 Cm) of ultra soft and cozy double type for workers deputed at site

3

1750

5250

... More
Providing of 1000-watt Havells walthero carbon room heater or equivalent make and model for workers deputed at site to use it during winter season.

1

4700

4700

... More
Providing of rechargeable 10W LED torch of havells/Ands light/equivalent make for workers deputed at site

3

1500

4500

... More
Providing, fitting, and testing of ceiling/corner fan “Havells/Orient/Bajaj” equivalent make having sweep of 1200mm (48”). working on 230V, 50Hz, 1ǿ A.C.

1

1800

1800

... More
Providing of plastic chair of following specification for site Make = cello/Neelkamal/Equivalent make Maximum load capacity = 150 Kg Finish Type = Glossy Material = Plastic Width = 57.5 cm Height = 88.5cm Weight = 3.3 Kg Seat Height = 320 mm

4

1300

5200

... More
Providing and fitting of 5KVA fully automatic voltage stabilizer ranging from 90-300 Volts giving output voltage of 200-230 Volts. The job also includes P/F of 12-volt DC battery 150 AH (Exide) along with 950 VA sine wave Inverter (Microtek/ APC/ Sukam make) along with leads terminals and necessary wiring complete in all respects.

1

38000

38000

... More
CREATION OF 630 KVA SUBSTATION 11/0.433kV,630kVA 3-Phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Copper Wound ) and with LV Cable Box having detachable Aluminum Gland plate Transformers should have arrangements for vertical takeoff cable with OCTC (off ckt. Tap changer). 9 mtr long Pole (ST-410, SP-33) G.l Pipe of 150mm dia 2mtr long fore pole butts G.I Channel / Angle / Flat of sizes including Clamps Transformer Pad / G.I channel bedding 11KV Polymeric composite pin insulators 12kV, skN, lightening impulse 75kV positive and 80kV negative, creepage distance 320mm 11KV Polymeric composite disc insulators 12kV, min falling Load 45kN, lightening Impulse 75kV positive and 80kV negative, creepage distance 320mm(1Set=3Nos.) 11KV G.O, AB switch 3-phase, 3pole,200Amp, vertical type 11KkV Horn Gap Fuse Set 3 Phase 200A 11k ‘Gapless surge arrestor, 9 kV, 10kA, LA with polymer housing station type LT Distribution Box for 630kVA DTR with 1000Amp MCCB 3P (36kA) adjustable 1no for incomer & 250Amp MCCB 3P 25KA 2Nos. fixed & 200Amp MCCB 3P (25KA) 3Nos for outgoing circuit. 400sqmm Single core cable 1.1kV Grade, XLPE insulated stranded conductor FRLS type. Sundry items like aluminium lugs, jumpers, Binding tapes etc. Wedge connector/PG Clamps Galvanized Nuts & Bolts Galvanized stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3.15mm dia GI stranded wire complete Earthing of Sub Station – Excavation of earth pit dia 650mm & depth 3000mm, installation of earthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5mtr long asper IS 1239. GI strip for neutral earthing of size 25mmX3mm for connection of transformer body, GO set & lightening arrestors as per IS 2629/85, GI nut & bolts refilled with earth enhancement materials and earth chamber made of brick masonry with RCC slab cover. Cement bottoming 1:2:4 as per standards 0.5cum/pole Painting of poles(red Oxide=2ltr & Alminium paint =2 ltr) Danger plate with clamps GI Barbed wire for anti climbing Signboard LV Line Part 11mtr long Pole (ST-410, SP-56) 9 mtr long Pole (St-410, SP-33) 8 mtr long Pole (St-410, SP-15) 30sqmm ACSR Conductor G.I Channel V-X arms 75x40x6mm with Top bracket including suitable clamps /collars (10Nos.) As per REC Standard 11KV Polymeric composite pin insulators 12kV, 5kN,lightening impulse 75kv positive and 80kV negative ,creepage distance 320mm G.I channel 75X40X69’ long including suitable clamp &collar as per rec standards (04Nos) 11Kv isolator double break 3-pole 630 Amps Horizontal mounting type with earth switch Galvanised Nuts & Bolts Galvanised stay set with 50X8mm stay clamp, guy insulator(02nos), anchor plate (200X200X6)mm nut bolts, 02nos turnbuckle, 1.8m long, 16mm diameter solid GS stay rod &7/3.15 mm dia GI stranded wire complete. Earthing complete by GI pipe 40mm 3mtr long through GI strip 25X3mm Cement bottoming 1:2:4 as per standards 0.6cum/Pole Cement bottoming 1:2:4 as per standards 0.5cum/Pole Cement bottoming 1:2:4 as per standards 0.4cum/Pole Painting of poles(red Oxide= 11ltr & Alminium paint= 11ltr) Danger Plate with clamps Anti climbing device with clamps 11 KV HT Tri vector meter CT & PT operated

1

2624471

2624471

... More
Earthing/Signage/Retrofitting: Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts and nuts @ 300mm c/c all along the periphery as well as in two vertical rows along with theft resistant measures including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawing, specification, and direction of Engineer-in-charge (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).

3.71

6396

23729.16

... More
Earthing Complete earthing of electrical motors, distribution panel, APFC panel, voltage stabilizers, etc. with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

2

7472

14944

... More
GI strip for earthing Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) It shall be mandatory to carry out the third-party inspection of all electro mechanical gadgets including control valves through the reputed/ registered third party inspection agency (EIL/CEIL/RTES). Regarding the manufacturing works carried out at site i.e. Fabrication, installation of suction pipes, delivery manifold, working plat form, sump gantry, internal gantry etc., The material shall bear the manufacturers test certificate of reputed/ registered manufacturers confirming to relevant IS specifications which shall be checked at site before installation.

30

144

4320



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.