Irrigation And Flood Control Department Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Irrigation And Flood Control Department - IFC Tender

Civil And Construction
Eprocure
Opening Date10 Jul 2021
Closing Date26 Jul 2021
Tender AmountRefer Documents 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Column Pipes: Providing, fabrication, installation and testing of 80mm dia MS column pipe (5 Nos. 10 feet each in length), flanged (18mm Thick flange) and provided with necessary brackets and gaskets etc as per sample. The job also includes P/F of 300mm Diameter Steel Liner 20 feet long connected at the bottom of the sump with 200mm tail piece 3 feet long. The job includes Earth work excavation out side the sump in order to connect the Liner with the sump. The job includes all head loads and lifts. The tail piece should be connected with the 300mm liner at a distance of 7 feet from the bottom of liner. The job includes making of 250mm diameter hole at the bottom of sump by way of cutting of concrete wall etc. (stage 2nd )

1

-

-

... More
Gantry: Over Head Gantry:- Fabrication / Erection of Channel iron column to act as support for resting of monorail crane as per following details:- Vertical Posts=ISMC 150, No. of vertical posts=02 Nos, Vertical channel section each post , 02 Nos. vertical post bracing=ISMC 100, Sole / Matching plates=500x300x12 mm, Height of vertical posts=4.5 M, size of vertical post concrete blocks=600x600x900mm, Concrete grade=M20, welding Electrode=Overcord SS of Adore/ESAB/L&T, Monorail Section=ISMB 200, length of monorail=5M, Steel Detail :ISMC 150, 4.5Mx2x2 =18 M @ 16.4kg/m = 295 kg, ISMC 100, 0.25Mx8x2x2=8 M @ 9.2kg/m = 73.60 kg, Plate, 0.500x0.300x8 (12mmthk)=1.20 M²(12thk) = 112.80 kg, Monorail ISMB 200, 5 M @ 25.4 kg/M=127kgs, Bolts/Nuts,(L.S)= 20Kg, Total =628.5 kg = 630 KG say, Supply, Installation of 3 ton capacity motorised chain hoist with hook suspension having following specifications:-Make= INDEF (HERCULES BABY-KEH) Capacity =3 ton Hoisting speed = 2.4 M/Min Hoist motor H.P= as per requirement No. Of chain falls = 4 Min. Height of lift = 3 M MONORAIL = As per requirment Note:- All descriptive data given above is approximate, intended to give general idea of the product. The equipment be supplied as per the latest parameters / specifications. The chain hoist shall also have the following characteristics:- 1. Motor:- The basic drive of the hoist be provided with 3 phase squired cage totally enclosed induction motor having a high starting torque with class “F” insulation. The make of the motor be NGEF / SEIMNS / GEC/ Crompton and conform to IS : 325 (RPM-1500), ) 2. Brake:- The hoist shall have instant action, Fail to safe electromagnetic disc brake mounted on the end of the motor to ensure minimum safety and reliability when the load is held in its position as soon as the supply to the motor is switched off internally or accidentally. The adjustment & maintenance of break shall be quick and simple.3. Gears:- The hoist shall have precision cut super and helical gears made of alloy steel mounted on bearings and housed in a dust proof gear box. The lubrication of gears be of high viscosity and temperature for longer life of gears.4. Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. 5. Load chain wheel:- Specially designed, perfectly machined wheel providing correct grip of load chain made of malleable cast iron makes the hoist most safe and reliable against any failure. 6. Lifting Hook:- The lifting hook shall be forged with provision for free swivelling. 7. Limit Switch :- The limit switch shall have snap action, shunt type prevent over hoisting or over lowering to ensure maximum safety of operation.8. Control:- The unit shall be controlled by heavy duty air break direction reversing type contractors and electrically inter – locked for safety. Contactors relay, fuses, low voltage transformer be fitted for control voltage and are to be housed in fabricated / pressed sheet steel box dust proof. 9. Push button pendent:- The contactors shall be operated by a pendent push button station suspended from hoist by a rope / dog chain to prevent any damage to the pendent cable and for easy operation. Test:- The hoist supplied is to be tested at 25% overload and the test certificate of the same be provided at the time of installation. The complete unit as specified above is required to be fitted / tested at site. Complete painting of fabricated structure by way of applying of two coats of red oxide as primer and then painting with enamel paint of any shade with two coats (powder coated). (stage Ist )

1

-

-

... More
Gantry: a. P/F of 3-ton chain pulley block with Mono rail Pull Lift/ Indef make having lifting capacity of 5m. Complete with U. clamps, chain, hooks and other allied fixtures. b. Fabrication / Erection of Channel iron column to act as support for resting of Chain Pully Block with Monorail as per following details:- Vertical Posts=ISMC 150, No. of vertical posts=02 Nos, Vertical channel section each post , 02 Nos. vertical post bracing=ISMC 100, Sole / Matching plates=500x300x12 mm, Height of vertical posts=4.5 M, size of vertical post concrete blocks=600x600x900mm, Concrete grade=M20, welding Electrode=Overcord SS of Adore/ESAB/L&T, Monorail Section=ISMB 200, length of monorail=5M, Steel Detail :ISMC 150, 4.5Mx2x2 =18 M @ 16.4kg/m = 295 kg, ISMC 100, 0.25Mx8x2x2=8 M @ 9.2kg/m = 73.60 kg, Plate, 0.500x0.300x8 (12mmthk)=1.20 M²(12thk) = 112.80 kg, Monorail ISMB 200, 5 M @ 25.4 kg/M=127kgs, Bolts/Nuts,(L.S)= 20Kg, Total =628.5 kg = 630 KG say, (stage 2nd )

1

-

-

... More
Control Valves and delivery manifold: Providing, installation, testing and commissioning of DI control valve viz, 80mm dia Sluice valve (PN 1.6) --- 02 No. 80mm dia NRV (PN 1.6)----02 No. Make: VAG/ TALIS/Sigma flow The job includes cutting of pipe at site and fitting of the above valves as per requirement includes all required fittings viz. 12mm thick flanges, gaskets, nut bolts etc. The Job includes painting of delivery manifold with one coat of red oxide and two coat of paint. (Colour as per direction of site engineer).Original Manufacturer’s Test certificates in original to be provided with the material before installation.

1

-

-

... More
Voltage Stabilizer: Providing, installation,testing and commissioning of 100 KVA Voltage Stabilizer with of following specifications: i. Range: 180 V – 415 V ii. Copper wound with adequate insulation and thickness suitable to the duty to be performed. iii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iv. Hysteresis loses to be minimum and temperature not to exceed 700C. v. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. vi. Voltage regulator switch to be of plate type with copper contact points having six boosting steps. The contacts to be suitable to withstand over loading current at least double the rated current over the considerable period of time. vii. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. viii. The container at its top to be fitted with porcelain insulators for housing poles. ix. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The creapage distance between the poles to be sufficient enough to accommodate the required size tube terminals to prevent arcing. x. The top of the container to have a display panel for housing 02 numbers voltmeters 0- 500V, square dial flush type along with 4 way selector switch and set of neon indicators. xi. Insulating media (T. Oil) of 11 KVA grade to be provided and filled with dielectric strength of 5 KV at 4m air gap. xii. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. Rating of stabilizer: 100 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables. (The Voltage stabilizer to be manufactured in a registered workshop in presence of person authorized by the undersigned). The T-Oil of specific grade should be provided in a separate barrel. (Stage Ist & 2nd )

2

-

-

... More
Sub Station: The construction of Sub Station includes: (i) Providing and erecting of four numbers of steel tubular poles 9m (SP33, ISI mark HTL-IS 1161 or IS-2713) with base plate 350mmx350mmx5mm long as per the latest IEE rules for fabricating 04 pole structure (with 2 NO. 9m SP33 poles and 02 No. 150mm dia 8mm thick pipes cut to adjust the height of the station bed as per site engineers instructions. (ii) Fabrication, providing and fitting of ISMC-100 (as per the drawing attached). (ii). Providing, fabrication and fitting of ISMC-150 pieces 8 feet long each 12 Nos. complete with nuts and bolts and clamps as per requirement for resting of HT transformer also includes providing and fixing of 8’x8’ chequered plate 6mm thick over the channels fixed with nuts and bolts. The job includes earthwork and concrete bottoming of sub-station as per requirement of site. (iv) Providing and fitting of lightening arrestor (Heavy duty, POST type). (v), Providing and fitting of set of drop out fuse set/ link set (G.O.D) heavy duty providing and fixing of set of HT insulator. (vi). P/Fixing of disc insulators set.(vii). Providing and installation of cable termination kits and thimblings as per site requirement. (viii) Providing and fixing of anti-climbing devices. (ix) Other items like danger plates. The job includes providing/applying of metallic primer coat and two coats of enamel paint. Complete earthing of sub-station as per IEE rules. (Chemical earthing 3 Nos as per requirement and directions of in charge Engineer to accessories of sub-station) (x) Manufacturing, installation and commission of , 250KVA, oil cooled L wound three phase, outdoor type 11/0.433 KVA conventional (non-seated) type distribution, transformer shall have core type construction, suitable for outdoor system as stop down transformer. The primary winding shall be connected in the delta and secondary winding in star with symbol (DYLL). The neutral of separate insulated terminal. The core shall be built up of high grade chrome annealed silicon steel laminators having low loss and coated with firmly with channeled frame to prevent noise and vibrations. The LV winding shall be circular and concentric with HV winding on the outside. The arrangement of winding should be robust in elect./ mechanical construction and should permit free circulation of oil to avoid hot spots. Adequate bracing shell be provided so that a strong self-supporting coils is obtained, no tapes shall be provided in the Winding Electrical grade epoxy dotted or other suitable insulations both for LV and HV windings. The transformer tank shall be made out of MS Sheet of minimum thickness 3.15mm thickness for sides and 5m thicknesses for top and bottom plate, suitable to withstand extreme pressure conditions. Primary coating and two coats of enamel paint should be duly painted on the tank. The transformer shall have a conservator tank provided with a drain plum-filling hole with cover. The cover shall be with 75x49 mm channel, with holes to make them suitable for mounting on plate/ plinth. The transformer tank shall be fitted with new 11 KVA grade T oil up to specific mark, the earthing terminals, two lifting lungs, rating and terminal marking plate, bi-metallic terminal connection for High Voltage/ Low V voltage side bushing level gauge, breather, duly valve should be provided to the transformer. Original Manufacturer’s Test certificates in original to be provided with the material before installation.

1

-

-

... More
HT POLES Providing and Errection of 9 Mtrs long M S Tubular poles having reducing dia of 6’’x 5’’ x 4’’ from bottom to top. The job includes P/F of 5 feet long cross arm ISMC-75, cross brace 1m x 40mmx 5mm, 3 no. HT insulators with pins to each pole. The job also includes spiral earthing, painting of poles in silver colour, grouting of poles in CC blocks of (1:1 ½:3) mix, P/F of danger plate indicating (11000V-DANGER) & P/F of nuts and bolts of assorted size.

2

-

-

... More
LT CONDUCTOR P/Laying of aluminum conductor 0.05 ACSR with all head loads and lifts etc

120

-

-

... More
Control Panel Fabrication providing and fitting of Modular control panel of Appropriate size fabricated out of 16 SWG sheet having required openings/vents and protection class: IP 55 and fitted with accessories as under:- a. Incomer = MCCB (250A) Qnty = 1 No Make = L&T / Siemens/ABB No of poles = 4 Rated operational voltage = 415V ± 15% Rated Frequency = 50± 3% Hz Ambient temperature = 40 deg c Ultimate S.C circuit Breaking capacity At (425 AC 50 HZ = 36 kA Thermal release range = 125-160 A b. Change over switch Make = L&T/Siemens/ABB Qnty = One No Type = CO2-125 4 pole Rating = 125A c. Distribution Bus Bar Electrical grade Al with red, Blue and yellow tapping of Adequate section. Rating = 200 A d. Circuit Breaker = MCCB (100 A) Qnty = 4Nos Make = L&T / Siemens/ABB No of poles = 3 Rated operational voltage = 415V ± 15% Rated Frequency = 50± 3% Hz Ambient temperature = 40 deg c Ultimate S.C circuit Breaking capacity At (425 AC 50 HZ = 36 kA Thermal release range = 100-125 A e. Auxiliary circuit Breaker = MCCB (100A) Qnty = 1 No Make = L&T / Siemens No of poles = 4 Rated operational voltage = 415V ± 15% Rated Frequency = 50± 3% Hz Ambient temperature = 40 deg c Ultimate S.C circuit Breaking capacity At (425 AC 50 HZ = 36 kA Thermal release range = 80-100 A On-off switches = 5 Nos (16 A) Copper strips = 4 Nos (3 Nos for three phases and one No for Neutral) f. Starters Make = L&T Rating = MU-G30 Power Specs = 3 phase, 425 ± 15 % Qantity = 4 nos g. Ampere meter Size = 96mm Sq Range = 0-50 A Make = L&T/Rishab CT coils = Requisite 5 VA - 10 VA capacity 7 CT ratio CT coil per meter = 2Nos (L&T) Type = Analogoue Qnty = 1 No (In Bus Bar Chamber) with selector Switch h. Voltmeter Size = 96mm Sq Range = 0-500 Volts Make = L&T/Rishab Type = Analogous Qnty = 1 No (In Bus Bar Chamber) With Selector Switch I) Frequency meter Qnty = 1 No (In Bus Bar Chamber) Frequency meter = 0-50Hz Type = Analogues Make = L&T/Rishab/AE J) Power factor meter Qnty = 01 Nos Type = Analogues Make = L&T/Siemens/ABB k) Neon Indicators Qnty = 3 Nos 1 No (In Bus Bar Chamber) The modular control panel shall have the dimensions and cabins as detailed in the enclosed drawings. The enclose shall be of excellent fit and finish, corrosion resistant treated and powder coated gliding hinges for smooth and noiseless movement. All the electrical joints in the panel shall be fitted with Belleville washers. Original Manufacturer’s test certificates in original to be provided for all the accessories/ items required for Control Panel before its installation.

1

-

-

... More
Distribution Cables: Providing, Installation, testing of multi-stranded copper conductor PVC insulated single core unsheathed 35mm sq. Copper cable for internal distribution wiring. The multi-stranded copper cable to be laid through PVC conduits on wooden plain boards fixed on walls with suitable plugs, nails and clamps. The job also includes termination of ends of cable with suitable rating of Cu. thimbles duly taped.Original Manufacturer’s Test certificates in original to be provided with the material before installation. Make: Havells/ National/Standard/Plaza/Imperial/ RR Kables.

300

-

-

... More
Service Cables: Providing, laying, installation and testing of 3.5 Core, 95 sq. mm. Aluminum Conductor, PVC insulated, armored cable from distribution box of Transformer to the voltage stabilizer at both stages of the scheme. Job also includes providing and installation of aluminum Thimblings of appropriate ratings (24 No.) duly crimped and taped.Original Manufacturer’s Test certificates in original to be provided with the material before installation. Make: Havells/ Polycab/ Finolex/RR Kables

50

-

-

... More
Motor cables: Providing, laying and testing of flat 3 core copper 16 sq mm submersible cable. The cable shall be PVC insulated and impermeable to grease, water and abrasion resistant. The job includes providing of copper thimblings as per requirements. Original Manufacturer’s Test certificates in original to be provided with the material before installation. Make: Finolex/ Polycab/ Havells

200

-

-

... More
Illumination and other amenities: -Providing, manufacturing, installation and fitting of heat resistant toughened glass 60W LED street lights (04 Nos.) with following specifications: Power Consumption/ Rating = 60W Make = Havells/ Vinay/ Bajaj/ Syska Housing/ Bogy = Single piece Pr. Die cast Aluminum Alloy complete non dimmable, environmental friendly, weather proof, excellent aesthetics. Operating voltage = 140- 270V, 50Hz The street lights to be fixed on the galvanized steel poles (04 nos to be provided), octagonal type 8m each complete with required MCB (02 nos.) of 10 amperes, required cable of 1.5mm2 (copper wire multi stranded type) from MCB to light through PVC conduits. The MCBs to be housed in MS boxes. The steel poles to be provided with 2 MS arms for each pols for housing street lights. The job also includes providing, installation, fitting and testing of 40W LED lights (01 No.) with heat resistant toughened glass with following specifications: Power Consumption/ Rating = 40W Make = Havells/ Vinay/ Bajaj/ Syska Housing/ Bogy = Single piece Pr. Die cast Aluminum Alloy complete non dimmable, environmental friendly, weather proof, excellent aesthetics. Operating voltage = 140- 270V, 50Hz The job also includes providing and fitting of MCB of 10 amperes, required cable of 1.5mm2 (copper wire multi stranded type) from MCB to light through PVC conduits. The job also includes providing and installation of 5 No. 12 Watt LED Lamps along with holders and switches and fitting by providing 1.5 sq. mm copper wire as per site requirement. Providing and installation of 16 A sockets along with 4 sq mm copper wire as per site requirements. All wires, to be laid through double U channels along with clamps, screws and other accessories. -Providing and fitting of inverter cum battery (180AH) with 5 No inverter lumps with all accessories like wire holder, channels ,switches and lumps. -Providing of solar/ electrical lantern both chargeable in solar/electrical (Indus/Tata) (01 No.). -Providing of bedding including mattress, pillows, blankets and utensils as amenities to the pumping station staff as per requirements. Providing of tool kit consist of following items :-  Spanner set = 12 pieces of size 4/5,6/7,8/9,10/11,12/13,14/15,16/17,18/19, 21/23,24/26,24/27,30/32  Ring set = 12 pieces of same size as above  Pliers = 2 No`s (tappari/ jalani)  Cutting pliers = 2 No`s(tappari/jalani)  Screw driver = 2 No`s (tappari/jalani)  Hammer = 1 no of size 1 kg  Pipe wrench = 2 Nos of size 12 inches Mutimeter = 1 No L Keys = one complete set

1

-

-

... More
Earthing: Chemical Earthing of all the electrical equipment’s like transformer, lightening arrestor, sub-station using Electrode as per load, 2 Meters long connected with desired sized Aluminum internal strip complete with excavation, civil works, cast iron cover with back fill compound as required. The said earthing pit shall be completed taking into account the load of the equipment’s installed at site in consideration, included is installation of required sized Aluminum strips from earthing station to all the installed equipment’s with all desired items required.

4

-

-

... More
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil

2541.99

-

-

... More
Ordinary Rock

942.08

-

-

... More
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil

169.55

-

-

... More
Ordinary Rock

71.81

-

-

... More
Providing and laying of nallah muck on level incld. All carriages

72.75

-

-

... More
Supplying, stacking , laying and spreading on horizontal on level at site Graded crushed stone aggregate of size: 90 mm to 45 mm

109.12

-

-

... More
63 mm to 45 mm

72.75

-

-

... More
53 mm to 22.4 mm

48.5

-

-

... More
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density

48.5

-

-

... More
Laying water bound macadam sub-base with brick aggregate and binding material, earth etc. including screening, sorting, spreading to template and consolidation with light power road roller etc. complete ( payment for brick aggregate and moorum etc, to be made separately) :

72.75

-

-

... More
Providing G.I. pipes complete with G.I. fittings ( light weight) class-A conforming to IS 1239 part ist : 100mm dia G.i

1000

-

-

... More
80mm dia G.I

1000

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) ( Medium)Class-B conforming to IS 1239 part ist : 100mm dia G.I

500

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) ( light weight) class-A conforming to IS 1239 part ist : 100mm dia G.I

80

-

-

... More
80mm dia G.I

70

-

-

... More
65mm dia G.I

2000

-

-

... More
50mm dia G.I

1700

-

-

... More
40mm dia G.I

2300

-

-

... More
25mm dia G.I

1800

-

-

... More
20mm dia G.I

2200

-

-

... More
15mm dia G.I

1200

-

-

... More
Providing and fixing of 100mm dia NRV, VAG/ AVR/ CRI/ SIGMA FLOW make in the rising main and immediately after the delivery of pump including the cost os T flanges dismantling joints and allied

2

-

-

... More
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore

1300

-

-

... More
Above 40 mm nominal bore

500

-

-

... More
Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work:- 50mm dia G.I pipe

500

-

-

... More
40mm dia G.I pipe

500

-

-

... More
25mm dia G.I pipe

600

-

-

... More
20mm dia G.I pipe

200

-

-

... More
Providing and fixing of 18mm thick M.S flanges to G.I pipe (For raising main) incld. Cost of flanges, rubber gaskets, nuts bolts, welding charges cutting of threads excld. Earth work and refilling: 100mm dia

88

-

-

... More
Providing and fixing of 12mm thick M.S flanges to G.I pipe incld. Cost of flanges, rubber gaskets, nuts bolts, welding charges cutting of threads excld. Earth work and refilling : 100mm dia

160

-

-

... More
80mm dia

160

-

-

... More
Providing and fixing of CI sluice valve with cap including all accessories like nuts, bolts rubber insertion etc and tail pieces of Kirloskar make including successful testing and commissioning (100mm dia).

2

-

-

... More
80mm dia

3

-

-

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore

85

-

-

... More
40 to 80 mm nominal bore

25

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm nominal bore

2

-

-

... More
65 mm nominal bore

2

-

-

... More
Constructing masonry Chamber of specified size, in brick work with common burnt clay (non modular) bricks of class designation 7.5 incement mortar 1:4 (1cement :4 coarse sand) and R.C.C. top slab 1:1.5:3mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mmnominal size ) including necessary xcavation, foundation concrete1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. For sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid. Chamber 120x120x100 cm

2

-

-

... More
Dumping stone including cost of stones. in Horizontal on level

143.06

-

-

... More
Hand-packing stones in wire-crates; including cost of stones butexcluding cost of crates

184.6

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m

1927.3

-

-

... More
Providing & laying stone soling in horizontal on level.

65.22

-

-

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

32.19

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

27.91

-

-

... More
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

49.76

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

6.14

-

-

... More
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:- 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)

12.74

-

-

... More
Providing & fixing of main hole cover 0.75 x 0.75 of standard quality with angle iron frame incld all necessary fittings complete

3

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more

12821.8

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.

1008.81

-

-

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

411.28

-

-

... More
Suspended floors, roofs, landings, balconies and access platforms

59.04

-

-

... More
Lintel, beams, plinth beams, girders, bressumers and cantilevers

48.87

-

-

... More
Arches, domes, vaults upto 6 m span

83.87

-

-

... More
Extra for shuttering in circular work

244.13

-

-

... More
Edges of slabs and breaks in floors and walls : Under 20 cm wide

37.07

-

-

... More
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

245.89

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

3606

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm

305.76

-

-

... More
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)

476.3

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

62.08

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete

15.23

-

-

... More
Supply and filling GSB (granular sub-base) in layer not exceeding 22cm in thickness & aggregate size does not exceed 90mm incld. carriage

18.47

-

-

... More
Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete

16.62

-

-

... More
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)

24.86

-

-

... More
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level

24.86

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Kiln seasoned and chemically treated hollock wood

0.66

-

-

... More
Dry random rubble masonry with hard stone in foundation and plinth: With bond stone. (quarry)

9.28

-

-

... More
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate

32.91

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). First class kail wood (35mm)

8.78

-

-

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. First Class kail wood

8.11

-

-

... More
Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete. First class Budloo/Fir wood

3.79

-

-

... More
Providing and fixing of anchor bolts of 16mm dia 9`` long

20

-

-

... More
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2

52.37

-

-

... More
Providing & fixing colour corrigated ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2

24.38

-

-

... More
Providing and fixing plained eaves boarding (Kail wood). 250x32 mm (nominal size )

26.06

-

-

... More
Provision for providing and fixing of ornamental gate weighing not less then 3.50 Qtl incld. steel pilars, necessary fittings , welding charges & all sorts of carriage complete job

1

-

-

... More
Providing and fixing of of Hardware items Aldrops 150mm dia

2

-

-

... More
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Tower bolt ( 150x10 mm ) long

2

-

-

... More
Tower bolt ( 100x10 mm ) long

48

-

-

... More
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125mm

8

-

-

... More
100 mm

3

-

-

... More
Air hooks

24

-

-

... More
Sliding door bolt ( almunium)

2

-

-

... More
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( 2 mm thick )

112.82

-

-

... More
Providing and fixing of GI pipes complete with G.I fittings & clamps incld. cutting & making good etc complete

24.38

-

-

... More
Providing and fixing of pvc pipes, cables with all pvc fittings incld. trenching and refilling etc (external with flateral 100mm dia pvc pipe) along with bends, sockets etc (prince quality)

15.24

-

-

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter

45.14

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work

45.14

-

-

... More
Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge Long pattern W.C Pan of size 580x440 mm

1

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes including all associated fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid lSI license]

1000

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (wall / floor tiles)

17

-

-

... More
Providing and fixing in position stainless steel sink of standard quality

1

-

-

... More
Providing and fixing of electric and heating points including wiring for lightning points in 1.5 sq. mm, PVC insulated copper wire and 2.5 sq. mm PVC insulated multi strand copper wire, 6mm one way switches, 2 mm thick PVC conduit/ channel with bends, junction boxes etc 6amp S pole MCS, 10 Amp DP MCB, 2 way for housing MCB, hylan sheet with wooden box recessed in walls with accessories complete: Lighting point

14

-

-

... More
Heating point

4

-

-

... More
Fan points with Fans

2

-

-

... More
Exhuast Fan 12" x12"

2

-

-

... More
Providing and mixing of water proofing material or equivalent for RCC work

703.19

-

-

... More
Providing and fixing of nuts ,bolts and chips incld one end fix to anchor block

150

-

-

... More
Providing & fixing of 80mm dia PVC pipe for aeration purpose

20

-

-

... More
Provision for temporary diversion & dewatering during construction

1

-

-

... More
supply of crate

9580.7

-

-

... More
Provision for road cuts

100

-

-

... More
Providing and fitting of 03 No. water Gysers, 7 No. water mixers. 16 No. Bibcock s, Mirrors, Jugs/ mugs & other bathroom accessories etc

1

-

-

... More
Providing and fitting of bedroom items Floor mating, 02 No. beds with necessary beding and mattresses , 02 no. wardroops for cloths, 1 no. locker, 4 chairs and one table etc

1

-

-

... More
Provision for Providing and fixing of pipe specials of standard quality incld. testing complete

1

-

-

... More
Carraige of materials from source to road site of work including loading , unloading and stacking:-- Stone / stone soling for an av lead of 15 km

421.5

-

-

... More
40mm aggregate for an av lead of 30 km

47.23

-

-

... More
20mm aggregate for an av lead of 30km

415.5

-

-

... More
sand for an av lead of 20 km

234.28

-

-

... More
cement for an av lead of 08 km

138.27

-

-

... More
steel /GS Sheets for an av lead of 08 km

17.79

-

-

... More
wire Crates for an av lead of 10 Km

1.87

-

-

... More
Wood for an av lead of 60 Km

4.3

-

-

... More
Bricks for an av lead of 75 km

12430

-

-

... More
Carraige of materials from road site to site of work by manual labour including loading , unloading and stacking for an av lead of 450 Mtrs. Stone / stone soling

421.5

-

-

... More
40mm aggregate

47.23

-

-

... More
20mm aggregate

415.5

-

-

234.28

-

-

55.18

-

-

... More
Cement

138.27

-

-

... More
Steel / GS Sheets

17.79

-

-

4.3

-

-

... More
Bricks

12430

-

-

... More
Wire crates

1.87

-

-

... More
Providing, erecting and fixing of sign board 2'6''x4' made up of angle iron frame work 50x50x6mm with 1mm thick M.S sheet including priming, painting and proper lettering and embeding with 1:3:6 cement concrete complete job

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.