Housing And Urban Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Housing And Urban Development Department - HAUDD Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date6 Jul 2024
Closing Date20 Jul 2024
Tender Amount₹ 38,50,000
Costs
EMD
₹ 77,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HAUDD_252355_1Bid Award Id
ViewTender No
JDA/II/e-NIT/2024-25/17 Dated 06-07-2024Tender Authority
Housing And Urban Development Department ViewPurchaser Address
-Website
http://http://jkhudd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
SITC of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
1
-
-
SITC of 11 kV Horn Gap Fuse Set 3 Phase 200A
1
-
-
SITC of 240mm²(2Ckt)/400mm² (2Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
44
-
-
SITC of 9 Mtr. Long Pole( ST-410 SP33)
2
-
-
SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm
3
-
-
SITC of GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
150
-
-
Supply and fixing of Galvanized Nuts and Bolts.
6
-
-
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts ,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
3
-
-
Transformer Pad/G.I Channel Bedding
100
-
-
SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, Creepage distance 320mm
3
-
-
SITC of LT Distribution Box for 400/630 kVA DTR with MCCB for incomer & SFU's for Outgoing Circuits
1
-
-
SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
2
-
-
Painting of Steel Tubular Poles two coat of Red Oxide Paint
1
-
-
Painting of Steel Tubular Poles two coat of Aluminium Paint
1
-
-
Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
2
-
-
Part - B 11 KV Taping Point
-
-
-
SITC of 9 Mtr. Long Pole(PCC WL-300Kg , ST-410
SP33 )
2
-
-
SITC of G.I V cross-arm with top Bracket including
clamp
34
-
-
SITC of G.I Channel/Angle lron including clamp
52
-
-
SITC of 11kV GO, AB Switch 3-Phase, 3-Pole, 200
Amp, Vertical Type
1
-
-
50 mm² ACSR Conductor
15
-
-
PG Clamps for 50 mm² ACSR Conductor
3
-
-
SITC of 11kV Polymeric composite Pin lnsulator 12kV, 5kN, Lighting lmpulse 75kV Positive and 80kV Negative, creepage distance 320mm
6
-
-
SITC of 11kV Polymeric composite Disc lnsulator 12kV,min failing load 45kN, Lighting lmpulse 75kV Positive and 80kV Negative, creepaee distance 320mm
3
-
-
Supply and fixing of Galvanized Nuts and Bolts
1
-
-
Earthing Complete by Gl Pipe 40 mm or Gl Rod 20mm 2.5 mtr long through Gt strip. (for 2 No ST poles and 1 No GO Switch)
2
-
-
Red Oxide
2
-
-
Aluminium Paint
2
-
-
Cement bottoming 1:2:4 mix as per REC
standards 0.5cum /pole
2
-
-
PART-C 11 KV HT LINE
-
-
-
SITC of 9 Mtr. Long Pole (PCC WL-300Kg , ST-410 SP33)
20
-
-
SITC of 70 mm² AB (HT) Cable (3x70+1x50 mm²) XLPE (11 KV, 3C + Earth)
1
-
-
Heat Shrinkable Outdoor Cable Termination Kit
3
-
-
Suspension / Tension Clamp with eye hook
20
-
-
Supply and fixing of Galvanized Nuts and Bolts
10
-
-
Earthing Complete by Gl Pipe 40 mm or Gl Rod 20mm 2.5 mtr long through Gt strip.
20
-
-
Cement bottoming 1:2:4 mix as per REC standards. 0.45cum/pole
20
-
-
Mid span straight through Jointing Kit for 11 KV ABC
1
-
-
SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2N os. ), anchor plate (200x 200 x 6mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia Gl stranded wire complete
5
-
-
PART -D LT EXTENSION NETWORK
-
-
-
Supply and erection of 9 mtr. Long PCC poles for supplying power to new possession holder customer at Roop Nagar Housing Colony by excavation and back filling the same with cement bottoming of the pole in ground in the ratio of 1:2:4 IS code for PCC pole IS 1785 (Part-I & Part-II) or 196 IS 6003 or 1983 IS 383-1970 with latest amendment
70
-
-
Supply and laying of 70 mm sq. AB (LT) cable (3x70+1x16+1x50 Sqm) (1.1 KV + 31 Core Alu)
1.8
-
-
Supply and laying 50mm LT AB cables (3x50+1x16+1x35 mm. sq. XLPE (1.1 kV +3+1 core Alu)
1.2
-
-
Supply and fixing of suspension tension clamps with eye hook
150
-
-
Supply and fixing of straight through cable jointing kit
2
-
-
Supply and fixing of Gavanized Nuts and Bolts
50
-
-
Earthing Complete by GI Pipe 40 mm or Gl Rod 20mm 2.5 mtr long through GI Strip.
70
-
-
Cement bottoming 1:2:4 mix as per REC standards. 0.45cum/pole
70
-
-
Supply and fixing of Insulating Piercting Connector
350
-
-
Supply and fixing of LT distribution box for service line of plot holders with SPN and TPN and aluminium bus bar fitted in fibre box (Complete Job).
70
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements