Housing And Urban Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Housing And Urban Development Department - HAUDD Tender
Eprocure
Opening Date8 Oct 2018
Closing Date13 Oct 2018
Tender Amount₹ 2,55,00,000
Costs
EMD
₹ 5,10,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_HAUDD_63044_1Bid Award Id
ViewTender No
SE/JDA/Fresh/e_NIT/2018/53 Dated 06-10-2018Tender Authority
Housing And Urban Development Department ViewPurchaser Address
-Website
http://http://jkhudd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Installation of 11 KV LA 10 KA (station Class)
1
-
-
... More
Supply, Installation of 11 KV HG Fuse Unit
1
-
-
... More
Supply installation of Disc Insulator (B & S) 70 KN suitable for 100 Sq.mm Triple AAAC.
3
-
-
... More
Supply and installation of B & S Hardware Fittings.
3
-
-
... More
Supply and Installation of 100 Sq.mm AAAC Triple AAAC.
25
-
-
... More
Supply Installation of 11KV Pin Insulator suitable for 100 sq.mm Triple AAAC.
3
-
-
... More
Supply and Erection of 150 mm Dia. Heavy Class G.I. Pipe for the cable Protection.
9
-
-
... More
Supply, Installation and Commissioning of 11 KV Meter with suitable size Outdoor Type Combined C.T. and P.T's of 200 / 1A Accuracy Class 0.5 S Burden 100 VA 11 KV/ Root 3/ 110 V/ Root3.
1
-
-
... More
HT PANEL :- Supplying, installation, testing & commissioning of indoor type floor mounted metal clad, 11KV VCB panel with 3 Nos. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto/ manually closing breaker suitable for use on 11 KV, 3 Phase, 50Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 630 Amps capacity, breaker featured with mechanical ON/ OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC with computer compatible and equipped with following switchgears and accessories i/c one earth truck, connections suitable for 3C x 240 sq.mm. XLPE 11KV cable (cable entry from bottom), power pack with 220 volt AC input & 24 volt DC continuous output suitable for closing/ tripping/ indication of HT panel board with 2 nos. 12 volts each maintenance free batteries of suitable AH capacity each (minimum 15minutes backup), charging unit, etc. complete job as required. Incoming - 1 No. 630Amp. VCB *1 set - 11KV/ 110 Volts PT Class 1.0 accuracy and 100 VA burden with 1 No. Voltmeter (0-15KV) digital type, selector switch for voltmeter and protection Fuse / MCB for HT metering upto 12 KV on incomer. *1 set - Digital flush type class - 1.0 accuracy multifunction meter with RS485 showing V, A, PF, KVA , KW, KWH etc. *1 set - Microprocessor based numerical relay with O/L , E/F and S/C protection . * 1 set - set of dual core dual ratio 3 CTs 200/ 100/ 5/ 5 A of 15VA burden and accuracy Class- 1.0 for metering and class 5P10 for protection . *LED indication lamps for R,Y,B, Breaker ON,OFF,TRIP, Trip circuit healthy, spring charged, DC supply healthy, etc. as required. Note:- (Considered item No.12.00 and 12.1 same and is one item) i.e. 1.00 set.
1
-
-
... More
*Outgoing - 1 Nos. 630 A VCB having following accessories. *Digital flush type class- 1.0 accuracy multifunction meter with RS485 showing V, A, PF, KVA , KW, KWH etc. as required.Microprocessor based numerical relays with O/L, E/F & S/C protections .
Set of dual core dual ratio 3 CTs 60/ 30/ 5/ 5 A of 15VA burden and accuracy Class- 1.0 for metering and class 5P10 for protection.
LED indication lamps for R,Y,B, Breaker ON,OFF,TRIP, Trip circuit healthy, spring charged, DC supply healthy, etc. as required.
Transformer protection release with 8 window annunciation each etc. as required.
Outgoing - 1 Nos. 630 A VCB having following accessories.
Digital flush type class- 1.0 accuracy multifunction meter with RS485 showing V, A, PF, KVA , KW, KWH etc. as required.
Microprocessor based numerical relays with O/L, E/F & S/C protections .
Set of dual core dual ratio 3 CTs 100/ 50/ 5/ 5 A of 15VA burden and accuracy Class- 1.0 for metering and class 5P10 for protection.
LED indication lamps for R,Y,B, Breaker ON,OFF,TRIP, Trip circuit healthy, spring charged, DC supply healthy, etc. as required.
Transformer protection release with 8 window annunciation each etc. as required.
HT Panel (3 VCB) as above
1
-
-
... More
H.T. Cable:- Supply of following sizes of 11kV grade multicore aluminium conductor XLPE armoured power cable as per IS: 7098 ammended upto date as per the following size. 11 KV (E), 3C x 185 Sq. mm XLPE Aluminium cable Armoured
125
-
-
... More
HT Cable laying:- Laying of one number PVC insulated and PVC sheatehd / XLPE power cable of 11 KV grade of 3X185 sq.mm. size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
125
-
-
... More
Supplying and making Indoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 11 KV grade as required. 11 KV (E), 3C x 185 Sq. mm Indoor type
3
-
-
... More
Supplying and making Indoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 11 KV grade as required. 11 KV (E), 3C x 185 Sq. mm outoor type
1
-
-
... More
Supplying, only of 11 kV Compact Secondary Sub Station outdoor type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated compact switchgear having metal enclosed robotically sealed/welded stainless steel tank , low voltage switchboard, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type,other associated equipment etc including necessary foundation and earth work etc. without oil pits complete as required conforming to detailed specification laid down in the tender documents. The enclosure shall have modular construction using CRCA sheets and shall be painted with polyurethane paint from the exterior.The enclosure for LT switchgear & HT switchgear shall be provided with IP54 ingress protection. The transformer compartment will have IP23D ingress protection. The transformer used shall be specially designed for low losses and shall be hermetically sealed & with corrugated tank.The earthing shall be suitable for 20kA fault current.The varoius combinations of CSS shall be as per details below including necessary foundation and earth work etc. *11kV Compact switchgear unit having 1 No SF 6 circuit breakers enclosed in robotically laser welded non-extensible type stainless steel SF6 enclosure with Self powered relay (IDMTL O/C + E/F ) as HT switchgear as per the requirement detailed in the tender documents/SLD. Copper bus bars of 800 A capacity for HT 11 KV network.A set of three PTs with 0-12 KV Voltmeter with selector switch. Dual core CTs having 60/30/5 ratio with Ammeter.
11kV/433V , 990 kVA , Cast Resin VPI type dry Transformer suitable for CSS as per detailed specifications, with Off Load tap changer.
LT section comprising the following:-Incoming:-2000 A, 4P ACB, electrical operated draw out type - 1 No. Solid copper Extension Links, with suitable holes, suitable for 2000 Amps., minimum 300 mm long for all three phases and neutral for L T Cable connection as required. Complete CSS as above
Corrected Qty 1 & Unit-Set
1
-
-
... More
Supply of Silent Type ‘Diesel Generating set water cooled with raditor alongwith Prime Mover, of Rating of 320 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings:
Diesel Engine
Diesel engine 4 stroke radiator cooled, electric start, of suitable BHP for 320 KVA Alternator at 1500 RPM suitable for above output of alternator at 55 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 3046, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories.
Engine mounted Instrument Panel fitted with and having digital display for following:
1) Start-stop switch with key, 2) Water temperature indication
3) Battery charging indication 4) RPM indication
5) Low lub. Oil trip indication 6) Engine Hours indication
7) Emergency Stop Button with wired remote facilty Alternator
Synchronous alternator rated at 320 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 55 Degree C, (Minimum 350 KVA at 40 deg. C) 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulatedthrough AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (The contractor shall clearly indicate deration factor for Alternator at 55deg C)
Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel ( necessary reinforcement cement concrete foundation shall be carred out by the civil agency but necessary technical drawings shall be provided by the DG set agency) .Daily service fuel tank of capacity (as per OEM standards) fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications and it also includes AMF Panel
1
-
-
... More
Supply, erection, testing and commissioning of semi rotary hand pumps including PVC/rubber fuel pipe of suitable length connections etc. complete as required.
1
-
-
... More
Supplying of following dia M.S. Pipe as per relevant IS:3589 specifications including LRV rock wool insulation having 100 kg per m3 density 75 mm thick for 250 mm pipe , chicken wire mesh and cladding with 24 gauge aluminium sheet, for exhaust of smoke of D.G. Sets including fixing the M.S. cladded pipes on the existing structure (including fixing of silencers, flexible bellows to be supplied by the owner as part of standard D.G. Supply) on the wall/ ceiling including cutting, welding primer coating and painting cost of supports etc. complete as required
The contractor shall submit back pressure calculation in support of exhaust pipe size for each DG Set
250 mm dia x 5.20 mm nominal thick
90
-
-
... More
Supply & Fabrication with Steel sections and erection of MD base frames, MS angle channels, flat etc for supporting various items of equipment Panel, Bus ducts, adapter boxes addition supportfor proper cable termination, cable trays , etc. Including welding, bolting, chipping, grouting etc, including applying one antirust coat of mapproved primer and two finished coats of approved paint, breaking and finishing of walls, floors etc. TH escoper is inclusive of minor civil work as required, supply & installation of GI hardware materials, consumables, anchor fasteners, tools & tackles and necessary labour with supervision but not limited to and complete as per approved drawings, specifications and directions of Engineer- in Charge. Scope also includes contractor's own lifting and transporting arrangement. The scope also includes CC foundation as required. The contractor shall submit the design Calculation & get the said approved for steel Bridge for crossing the road upto the tower block.
9000
-
-
... More
Providing and fixing M.V./ HT danger notice plate of following size, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required 200 mm X 150 mm, MV danger plate
4
-
-
... More
Providing and fixing M.V./ HT danger notice plate of following size, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required 250 mm X 200 mm, HT danger plate
4
-
-
... More
Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed conforming IS : 15683:2006 4.5kg capacity cylinder
8
-
-
... More
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 4 Kg. complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming IS : 15683:2006
8
-
-
... More
Providing of Set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket of appropriate size & capacity I/c filling san
1
-
-
... More
Providing of First Aid Box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS 2217-1963.
2
-
-
... More
Supplying & Fixing Shock treat chart duly mounted on a wooden frame with 5mm thick glass on as reqd. (approximate front area 1.20sq.metre) in 2 languages (Hindi & English)
2
-
-
... More
Supply and fixing 3mm (nominal + - 10%) thick and 1 mtr wide synthetic insulation mat suitable for 11 KV grade as per IS: 15652:2006 with upto date amendments along with suitable adhesive / sealing material, having properties like high insulation resistance, fire retardant, anti skid, good mechanical strength and moisture proof i/c sealing of all joints and corners as per manufacturer specifications etc. as required.
4
-
-
... More
Supply and fixing 3 mm (nominal + - 10%) thick and 1 mtr wide synthetic insulation mat suitable for 3.3 KV grade as per IS: 15652:2006 with upto date amendments along with suitable adhesive / sealing material, having properties like high insulation resistance, fire retardant, anti skid, good mechanical strength and moisture proof i/c sealing of all joints and corners as per manufacturer specifications etc. as required.
6
-
-
... More
Main Panel
Supplying of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and Indoor type floor mounted, free standing extendible type Main M.V. Panel compartmentalized design and fabricated out of 2 mm for load bearin members and 1.6 mm for non load bearing members CRCA sheet steel complete with Aluminium Bus bars of rating as shown drawings or as indicated in BOQ, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for bus trunking Incomings / Outgoings and also outgoing terminations for various sizes of cables, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, adequate size bus duct/cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing attached. Incomings: -
One (1) Nos., 800 A, 415V, 50 KA (Ics=Icu=Icw =50 KA for 1 second),4 Pole, Electrical draw out type, Computer Compatable Electrically interlocked, Micro-processor based release (for over current and Earth fault protections) A.C.B. with all indications, metering (as shown on the drawings and also as required), protections, push buttons etc. complete in all respects as mentioned in specifications and as required.
One (1) No., 2000 A, 415V, 50 KA (Ics=Icu=Icw =50 KA for 1 second),4 Pole, Electrical draw out type, Computer Compatable Electrically interlocked, Micro-processor based release (for over current and Earth fault protections) A.C.B. with all indications, metering (As shown on the drawing and also as required), protections, push buttons etc. complete in all respects as mentioned in specifications and as required.
LED type phase indication lamps - 3 Sets
Bus Couplers:-
1 No. 800 A, 415V, 50 KA (Ics=Icu=Icw =50 KA for 1 second) ,4 Pole, Electrical draw out type ACB's Electrically interlocked, with all indications, push buttons etc. complete in all respects as mentioned in specifications and as required:-
Outgoings: -
Following rated, 415V, (ICS=ICU=50ka for 1 sec) MCCB's with all indications, front operating handle & door interlock etc. complete in all respects as mentioned in specifications and as required:-
800 A, tpn 50 KA - 1 Nos
630 A, 4 P 50 KA - 1 Nos
400 A, 4P 50KA - 4 No.
250 A, 4P 50KA - 2 No.
100 A, 4P 50KA - 2 Nos.
63 A, 4P 50KA - 4 No.
Red Indicating Lamp for each Outgoing
Power Manager/Energy Analyser complete with Audio Alarm (in the panel as well as at remote place) to indicate the pre-set load value as required - 2 sets.
Multi function meter for indicating/ recording A, V, f, pf, KW, KWH, KVA, KVAH, and KVArH complete with required and suitable CTs for metering - 15 Nos.
Complete L.T. Panel Described as above
1
-
-
... More
APFC Panel
Supplying, installation, testing & commissioning of factory built floor mounted auto-manual power factor correction system panel of 440 KVAR capacity having 3 phase, Mixed Die Electric(total power loss not exceeding 0.50 W/ KVAR) power capacitor in thirteen steps, filled with suitable oil and; provided with 10 KVAR fixed capacity and balance Electronic Thyristor switching & detuned filters (min.7%) to supress switching of inrush current and reducing harmonics to improve capcitor life.
The system Shall be provided with required capacity master MCCB, to control its main operating parameters such as over loads, short circuit, etc.
The panel shall be fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, having 400 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35 MV A for I Sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 32 mm x 4mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears/ accessories with required size of Al. bus bars and control wiring with 2.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, of 2 mm thick MS Sheet, provided with exhaust fans (with thermostat) and grills for proper ventilation, interconnections with suitable size conductor cables & lugs and accommodating the following swicthgears & accessories:
-800 Amp 50 KA 3 Pole MCCB- 1 No.
-LED Indicating light - 12 Nos.
-One numbers dual source, dual setting, binary type automatic power factor sensing and correction relay (16 stages) complete with its all accessories etc. as required.
-MCCB of following capacity with spreader link and phase barrier. All MCCB shall be suitable for 35 KA. 125 A, 3P - 7 Nos.
63 A, 3P - 2 No.
32 A, 3P - 1 No.s
20 A, 3P - 2 No.
100 A 3P - 1 No.
L.T. Power factor improving capacitor of indoor type suitable for operation on 415 volts AC 3 phase 50 Hz complete with banking arrangement, interconnections with suitable size of copper conductor PVC insulated PVC sheathed unarmoured cable, discharge resistance etc. as required.
Bank of 5 KVAr rating - 2 Set
Bank of 10 KVAr rating - 1 Set
Bank of 20 KVAr rating - 2 Sets
Bank of 50 KVAr rating - 7 Sets
Bank of 30 KVAr rating - 1 Set (Fixed)
1
-
-
... More
METERING PANELS Supplying of dust, damp and vermin proof free floor standing factory built sheet steel enclosed non-drawout moduler type Floor Panel fabricated out of suitable sized angle iron and flats, base channel and covered with 2.0mm/1.6mm thick PCRC sheet, duly painted complete with earth bus, aluminium bus bar, numbering & sign writing, interconnection & including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking as shown in drawing as per specification and mounted with the followings.
This panel shall have 2 No.s 6/16A socket outlets each with 16 A switch in a compartment of approximately 450mm x 450 mm size, which shall also be used to house DLC connector and other required equipment. The panel shall also have atleast two number spare metering compartments to be used for future needs. The cost shall also include the interconnection of meters with DLC connector with Beldone cable etc. as required.
Incoming
400 Amp 50 KA 4 Pole MCCB - 1 No.
Multi function meter for indicating/recording A, V, f,pf, KW, KWH, KVA, KVAH, and KVArH complete with required and suitable CT.s for metering - 1 No.
Phase Indication Lamps - 1 Set
Busbar
400 Amp TPN Aluminium Busbar - 1 Set
Outgoing
63 Amp, 35 KA 4 Pole MCB - 25 Nos.
100 Amp, 35 KA4 Pole MCB - 1 Nos.
32 Amp, 10 KA 2 Pole MCB - 1 Nos.
1 Phase 2 wire as per BIS (IS13779) Dual source Energy Meter 10/30 Amp Compatible With AMR Based Prepaid Metering Solutions. The meter should not have Any inbuilt relay or contactor. The meter Should be Equipped with RS485 port for data communication and Should be compatible with AMR Based Prepaid System And disconnection devices.The item shall be complete with 32 A 2 pole contactor The meter shall be housed in a sealable and locable compartment as required - 1 No.
3 Phase 4 wire as per BIS (IS13779) Dual source Energy Meter 30/5 Amp with three numbers 30/5 metering class CTs, Compatible With AMR Based Prepaid Metering Solutions. The meter should not have Any inbuilt relay or contactor. The meter Should be Equipped with RS485 port for data communication and Should be compatible with AMR Based Prepaid System And disconnection devices.The item shall be complete with 40 A 4 pole contactor The meter shall be housed in a sealable and locable compartment as required - 25 No.s
3 Phase 4 wire as per BIS (IS13779) Dual source Energy Meter 30/5 Amp with three numbers 60/5 metering class CTs, Compatible With AMR Based Prepaid Metering Solutions. The meter should not have Any inbuilt relay or contactor. The meter Should be Equipped with RS485 port for data communication and Should be compatible with AMR Based Prepaid System And disconnection devices.The item shall be complete with 70 A 4 pole contactor The meter shall be housed in a sealable and locable compartment as required - 1 No.
3
-
-
... More
EXTERNAL LIGHTING PANEL
Supply, assembly, erection, connecting, testing & commissioning of LT weather proof dust and vermin proof, outdoor feeder pillar, fabricated out of suitable sized angle iron and flats and covered with 3mm thick CRCA sheet steel including canopy, duly stove enamel painted, both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports including RCC 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) foundation, 450 mm deep and 150 mm above the ground. The feeder pillars shall be complete with 3 phase and neutral bus bars of capacities as described below and moulded case circuit breakers (MCCBs) with adjustable overload relay, copper FRLS control wiring with 1.5sq.mm, complete in all respects as per specifications as required.
INCOMING:-
63A 4P MCCB (25ka) with thermal magnetic release & rotary handle - 1no.
3 Phase and neutral (100%N) aluminium bus bars of 150/ 100 amps. Capacity.
OUTGOING:-
70 AMP. TP CONTACTOR WITH NO/ NC CONTACTS -1 set.
24 HOUR TIMER - 1 set.
16A DP MCB (10ka) - 6 nos.
16 AMP. SWITCH & SOCKET - 1 no. with in the feeder pillar.
External Lighting Feeder Pillar as above
1
-
-
... More
EXTERNAL BOREWELL PANEL
Supply, assembly, erection, connecting, testing & commissioning of LT weather proof dust and vermin proof, outdoor feeder pillar, fabricated out of suitable sized angle iron and flats and covered with 3mm thick CRCA sheet steel including canopy, duly stove enamel painted, both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports including RCC 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) foundation, 450 mm deep and 150 mm above the ground. The feeder pillars shall be complete with 3 phase and neutral bus bars of capacities as described below and moulded case circuit breakers (MCCBs) with adjustable overload relay, copper FRLS control wiring with 1.5sq.mm, complete in all respects as per specifications as required.
INCOMING:-
100A 4P MCCB (25ka) with thermal magnetic release & rotary handle - 1no.
3 Phase and neutral (100%N) aluminium bus bars of 150/ 100 amps. Capacity.
OUTGOING:-
40 AMP. TP CONTACTOR WITH NO/ NC CONTACTS -3 set.
24 HOUR TIMER - 1 set.
63A TP MCCB (25ka) - 4 nos.
16 AMP. SWITCH & SOCKET - 1 no. with in the feeder pillar.
External BOREWELL Feeder Pillar as above
1
-
-
... More
Supply, laying, terminating, connecting, testing, commissioning and making proper terminations as required of LT XLPE aromoured, aluminium /Copper conductor cable 1.1KV grade, in trenches including the cost of digging and back filling the trenches, sand bricks / on existing cable trays / walls including the cost of saddles, gutties, clamps, lugs, brass, compresson, glands etc. as required of the following sizes. ALUMINIUM CABLE 3.5c x 400 sq. mm cable
500
-
-
... More
3.5c x 300 sq. mm cable
80
-
-
... More
4c x 25 sq. mm cable
200
-
-
... More
4c x 16 sq. mm cable
250
-
-
... More
4c x 10 sq. mm cable
250
-
-
... More
COPPER CABLE 2c x 10 sq. mm cable
600
-
-
... More
2c x 6 sq. mm cable
400
-
-
... More
Supply & Installation of Waterless and maintenance free Elancrete earthing electrode of size 80mm Dia x 6000 mm long with 17.2 mm Cu Bonded MS Conductor pre cast or in-situ cast in high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm.m. Electrode made of conductive earth enhancing material mixed with cement to encase or backfill the voids surrounding the 17.2 mm Cu Bonded MS conductor or other metal components placed in augured bore hole of 80 mm dia x 3000 mm depth, resulting to increase in the effective surface area of the earth electrode or grids to lower the resistance permanently with no further maintenance, like periodic rewatering or recharge of salt or earth enhancing compound for a very long period of over 40 years in dry soil or rocks. Earth enhancing material should not leach chemicals into the adjacent soil or underground water channels and should be in pH neutral range. Earth enhancing material should permanently protect the encased metal componets of the earthing systems. All hardware like nuts, bolts and washers should be of Stainless Steel. Electrode should withstand fault current upto 30 kA for 1 second. Electrode's top terminal be sealed permanently packed with conductive concrete and GI extension strip taken out be terminated on to earth bus bar.
17
-
-
... More
Supply & Installation of Waterless and maintenance free Elancrete earthing electrode of size 80mm Dia x 6000 mm long with 17.2 mm Copper Conductor pre cast or in-situ cast in high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm.m. Electrode made of conductive earth enhancing material mixed with cement to encase or backfill the voids surrounding the 17.2 mm Cu Bonded MS conductor or other metal components placed in augured bore hole of 80 mm dia x 3000 mm depth, resulting to increase in the effective surface area of the earth electrode or grids to lower the resistance permanently with no further maintenance, like periodic rewatering or recharge of salt or earth enhancing compound for a very long period of over 40 years in dry soil or rocks. Earth enhancing material should not leach chemicals into the adjacent soil or underground water channels and should be in pH neutral range. Earth enhancing material should permanently protect the encased metal componets of the earthing systems. All hardware like nuts, bolts and washers should be of Stainless Steel. Electrode should withstand fault current upto 30 kA for 1 second. Electrode's top terminal be sealed permanently packed with conductive concrete and GI extension strip taken out be terminated on to earth bus bar.
6
-
-
... More
Providing and fixing 50 mm X 5 mm G.I. strip in 80 mm dia G.I. pipe from FRLS on earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required
260
-
-
... More
Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
100
-
-
... More
Providing and fixing 50 mm X 5 mm insulated copper strip in 80mm dia. copper pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
60
-
-
... More
Providing and fixing 50 mm X 5 mm insulated copper strip on surface or in recess for connections etc. as required.
40
-
-
... More
Supply of Ground Burial Luminaire Uplighter for trees, The fixture shall be made of Die cast aluminium housing, duly powder coated, 316L SS Flange, mounted in an external sleeve with SS screws. Toughened / Tempered glass of 6mm , silicone sealed to ensure complete water proofing,IP67, Including 1 No 12watts COB 24 deg. beam LED light source - each integral control gear with LED of Warm white colour 3000K. Thermal management heat sink shall be part of the fixture. suitable for Operating voltage 210 V AC to 240 V AC. (TREE UPLIGHTER).
Make:-
Litolux Cat. No. -LTL-E-Q1DEQ9018
Unilamp Cat No. ZET1-Clear 9011-5-3-869-91
Debbas Cat No. MY 80030-AL-LED.103
18
-
-
... More
Supply of Spike mounted Shrub uplighting luminaire, The fixture shall be made up of die cast housing duly powder coated. Heat resistant toughened glass, mounting spike, provided with heavy duty LED driver Including 1 No 3 watts ) with 24 deg. beam LED light source - each with integral control gear with LED of Warm white colour 3000 deg K. Thermal management heat sink shall be part of the LED lamp. suitable for Operating voltage 210 V AC to 240 V AC. (BUSH UPLIGHTER)
Make:-
Litolux Cat. No. -LTL-E-A2ZA9046
Unilamp Cat No.Telescope 5911-7-3-901-02/ 9-2000-00
Debbas Cat No. MY 80001-AL-LED.043
60
-
-
... More
Supply of Bollard Luminaire, The fixture is made of extruded aluminium body. Nominal height 750-800 MM. Complete in all respects, Including 1 No 6 watts (or 6 no 1 watt) LED light source - each LED of Warm white colour 3000 deg K with integral control gear. Thermal management heat sink shall be part of the LED lamp. suitable for Operating voltage 210 V AC to 240 V AC. (BOLLARD LIGHT) Make:-
Litolux Cat. No. - LTL-E-ZA0960
Unilamp Cat No. Mini AGAR Prismatic- Bollard 7154-0-3-855-02
Debbas Cat No. 146321+955201
8
-
-
... More
Supply of Pole mounted post top luminiare. The Luminarie should be suitable for 43 W LED lamp and body made up of die cast aluminium alloy, with tempered flat printed glass with high transaprency polymethylmethacrylate lenses. The fixture should have easy and fast replacement of optimal unit and power supply. The fixture should have protection level of IP 66 and protection against impact IK08. complete in all respects as required. (POST TOP FIXTURE)
Make:-
Litolux Cat. No. -CARIBONI Italy AGATHOS
Unilamp Cat No.EPSYLON Pole- Top Light 7210-0-3-875-01
Debbas Cat No. AR0OL-70110/AN/C
29
-
-
... More
Supply of Wall mounted luminiare. The Luminarie should be suitable for 26 W LED lamp and body made up of die cast aluminium alloy, with tempered flat printed glass with high transaprency polymethylmethacrylate lenses. The fixture should have easy and fast replacement of optimal unit and power supply. The fixture should have protection level of IP 66 and protection against impact IK08. complete in all respects as required. (BOUNDARY WALL LIGHT)
Make:-
Litolux Cat. No. - ROSA Polland OS-11 LED
Unilamp Cat No.EPSYLON Pole- Top Light 7210-0-3-875-01
Debbas Cat No. AR-OL-70104/G/C
24
-
-
... More
Supply of Wall mounted luminiare. The Luminarie should be suitable for 43 W LED lamp and body made up of die cast aluminium alloy, with tempered flat printed glass with high transaprency polymethylmethacrylate lenses. The fixture should have easy and fast replacement of optimal unit and power supply. The fixture should have protection level of IP 66 and protection against impact IK08. complete in all respects as required. (GATE LIGHT)
Make:-
Litolux Cat. No. - ROSA Polland OS-11 LED
Unilamp Cat No.EPSYLON Pole- Top Light 7210-0-3-875-01
Debbas Cat No. AR0OL-70110/AN/C
2
-
-
... More
Supplying of 4 mtr. long galvanized Octagonal pole at site of works having 70mm at top and 130 mm at bottom, made out of minimum 3mm thick Galvanized sheet, Octagonal Pole duly painted with PU paint of approved colour/ shade, complete with 220mm x 220mm x 12 mm base plate with suitable hole for fixing the pole , suitable for wind speed of 160 km/hr and suitable hinged opening with locking arrangement. The pole shall be complete with 1 No. 6amp DP MCB and 2 numbers 15 amp. 4 way connectors as required including 2nos. earthing stud with a set of 4 numbers M16 x 450mm long "J" type EN 8 grade foundation bolts along with suitable template as per drawing and as required for the 4 mtr long pole.
Approved Makes of pole are as below:
BAJAJ/VALMONT/TRANSRAIL / AINOVA
29
-
-
... More
Providing and making foundation for 4 Meter high pole complete in all respect including excavation, back filling, steel reinforcement with cold twisted bar, PCC with 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) & main foundation 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), fixing of 'J' Bolts ('J' bolts provided by other agency) including curing, back filling etc. as required, including suitable length of 32 mm GI pipe for cable entry size & design of foundation shall be as per drawing no. EL-09 complete as required.
29
-
-
... More
Erection of octagonal pole of 4 mtr. Length on existing foundation, fixing of nut on bolt after applying required pressure including inter connection in existing junction box complete as required.
29
-
-
... More
Receiving, assembling, erecting, connecting, testing and commissioning of LED post top lantern on existing poles complete as per manufacture standard and complete in all respects as required.
29
-
-
... More
Receiving from store, assembling, Installation, testing, connecting and commissioning of shrub uplighting luminaries including making necessary connection with the cable complete as required.
60
-
-
... More
Receiving from store, assembling, Installation, testing, connecting and commissioning of Ground Burial Luminaries Uplighter for trees including the cost of digging necessary hole as required also making necessary connection with the cable complete as required.
18
-
-
... More
Receiving from store, assembling, Installation, testing and commissioning of Bollard Luminaries and making necessary C.C. (Cement Concrete) foundation including making necessary connection with the cable complete as required.
8
-
-
... More
Supply, Assembly, Erection, Testing & Commissioning of underground weather proof four way connector box IP68 rated complete with 2 nos 4 way brass connectors initial filling of gel etc. as required. The quoted rate should include the cot of digging & back filling the earth for mounting the connector.
The approved make TEE-Tube Model TH402 IP68
135
-
-
... More
Supply, Assembly, Erection, Testing & Commissioning of wall mounted weather proof four way connector box IP67 rated complete with 2 nos 4 way brass connectors etc. as required (Make henson or Maharaja)
26
-
-
... More
Supply, Installation, Testing & Commissioning of CPRI tested Controlled Early Streamer Emission (ESE) Lightning Conductor fully autonomous type having central pick up rod full electrical continuity between the tip and the earth point with collect ambient energy through a lower series of electrodes. Timing of the streamer emission controlled with an electronic device that detects the lightning and triggers a streamer Manufactured as per NFC 17-102. Test meter must be available to check the functionality of the ESE Lightning arrestor. complete system as required to gain in trigging time and radius of protection must be as per the following: TZ 50 for minimum protection radius of 34 mtrs. (Level-1)
3
-
-
... More
Supply & Installation of 5 meter long Class B GI elevation Pole of 50mm dia complete with reducer at the top to fix the unit along with Base plate, guying kit, clamps and other accessories & fittings etc. complete as required.
3
-
-
... More
Supply and laying of 70 sq. mm PVC insulated copper flexible single core cable ISI marked for down conductor including all accessories from air terminal to the earth pit etc. complete as required.
210
-
-
... More
Supply & Installation of transient event counter having resettable 2 digit LCD display with inbuilt lithium battery in IP67 rating enclosure with transparent lid, mounting arrangements etc. complete as required.
3
-
-
... More
Supply, installation & testing of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3mtr long 80mm dia of outer shell (MS) with the 50mm dia of inner shell (MS) of 80-100 microns galvanized filled with highly conducting metallic compounds with the permanent sealings at both the ends with 50 Kgs of mixture of Resistance Lowering Grounding Minerals. The chemical compound should be tested and certified by any International accredited and BIS (Bureau of Indian Standards) accredited laboratory. The earth rod shall be duly tested & certified by CPRI (Central Power Research Institute), Govt. of India for a minimum short circuit current of 25 KA rms. The chemical earth electrode manufacturer shall be an ISO 9001: 2008 & ISO 14001: 2004 certified organization. The Earth pit should be covered with heavy duty polyplastic weather proof chamber. (Make: TERCEL/ LPI/Elan Cret)
6
-
-
... More
Supply & Installation of Test Clamp to connect the down conductor to the earth termination and disconnect the down conductor from the earth termination for regular checks of the earth termination resistance value etc. complete as required.
6
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
60
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sqmm FRLSPVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLSPVC insulated copper conductor single core cable etc as required.
27
-
-
... More
Wiring for Group Controled (Looped) Light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sqmm FRLSPVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLSPVC insulated copper conductor single core cable etc as required.
7
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLSPVC insulated copper conductor single core cable for loop earthing as required.
40
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6amps modular socket outlet and 6 amps modular switch, connection, painting etc.as required.
6
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6amps modular socket outlet and 15/16 amps modular switch, connection, painting etc.as required.
6
-
-
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
6
-
-
... More
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed mediam class PVC as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
40
-
-
... More
2 X 6 sqmm in copper + 3 X 6 sq. mm earth wire
20
-
-
... More
Assembly installation testing and commisioning of prewired flourescent fitting/compact flourescent fitting of all types,complete with all accessories and tube/lamp etc,directly on ceilling/wall,including connections with 1.5 sqmm FRLS PVC insulated,copper conductor,single core cable and earthing etc.as required
16
-
-
... More
Supply of following compact and sleek integral design with built in power supply unit with minimum 100 lumen/watt having minimum 50 thousands per hour life span suitable for operation of 220/240 volts single phase supply of following power saving.
37 watts 4 ft 1170 mm long (Make:- Mayfair/ Bajaj / Philips)
6
-
-
... More
19 watts 2 ft 585 among long (Make:- Mayfair/ Bajaj / Philips)
8
-
-
... More
supply of surface mounted circular luminiare minimum 10 watt 200 mm dia with in built power supply with minimum 110 lumen/w suitable for operation of 220/ 240 volts single phase supply
2
-
-
... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the box is required.
5
-
-
... More
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
29
-
-
... More
Supply and Fixing of 300 mm sweap 230 Volt Exhaust fan heavy duty in the existing opening and making the hole and repairing the same complete as required.
8
-
-
... More
Supply of 1200 mm sweap ceiling fan complete as required. Crompton/Orient/ Havells make.
5
-
-
... More
Providing, fixing, testing and commissioning of UL / FM / EN / VDS listed / approved conventional automatic fire Alarm detectors Supplying, Installation, Testing and Commissioning of conventional type smoke detectors, 12 / 24 volt D.C., complete in all respects with base as required. (in Each tower lift shaft, machine room, Panel rooms, etc. etc. from basement to terrace and each tower lift machine room)
15
-
-
... More
Providing, fixing, testing and commissioning of resettable type manual call box (push type) with Fire written on the front side capable of giving individual address.The manual call box should have an indicator, which should "blink" green in case of normal condition and become steady Red in case of Operation. (in Each tower staircase from ground floor to terrace, control room, panel room etc.)
40
-
-
... More
Providing, fixing, testing and commissioning of electronic hooters with LMT (hooters shall also be able to work as public address system sounders) housed in sheet steel / Polymer housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications. (in Each tower staircase from basement to terrace)
40
-
-
... More
Providing, fixing, testing and commissioning of response indicators with dual LED suitable for operation on 12/24 volts D.C., sheet steel / Polymer housing suitable for surface/recess mounting including making connections with wires complete in all respects. (in Each tower electrical shaft outside from basement to terrace and outside lift machine room)
6
-
-
... More
Supply, installation, testing and commissioning of approved control relay, 1 amp contact rating & 1 NO, 1 NC, all accessories required for Hooters and controlling pressurisation fans, Elevators, complete including accessories like power supply, relays etc as required.
3
-
-
... More
Conventional 16 Zone monitor panel interfacing with conventional detectors as per requirement with power supply backup facility with seperately centralize Power for each tower, with necessary terminal block for incoming & outgoing cables/wires for interfacing between conventional detectors to Fire panel complete with cost of powder coated MS outlet box and accessories complete as per specifications and as required.(one for each tower conventional system)
3
-
-
... More
Conventional 4 Zone monitor panel interfacing with conventional detectors as per requirement with power supply backup facility with seperately centralize Power for each tower, with necessary terminal block for incoming & outgoing cables/wires for interfacing between conventional detectors to Fire panel complete with cost of powder coated MS outlet box and accessories complete as per specifications and as required. (one for each tower conventional system)
5
-
-
... More
Providing fixing testing and commissioning of Repeater panel (expandable type) with 2X40 character LCD display with facility to monitor tower control panel in network. . (in Guard room)
1
-
-
... More
Supply and laying of Copper Conductor Fire Survival control cable 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, glands, connectors, junction box, insulating with tape and making connections complete in all respect including supply of clamps, lugs, glands, JB, tape etc complete upto the satisfaction of Engineer-in- charge.
2C x 1.5 sq mm armoured in white Colour
2100
-
-
... More
4C x 1.5 sq mm armoured in White Colour
250
-
-
... More
Supply and erection of Perforated type cable trays made out of prefabricated Galvanized sheet steel including tees, bends, crossings, reducers, couplings to be laid in cable trenches or installed over head on wall or hanged from ceiling including all neccessary supports, brackets at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects.
The support for cable tray will be by 25 x 25 x 4 mm MS angle.
300 mm (W) X 25 mm (H) X 1.5 mm (T)
25
-
-
... More
150 mm (W) X 25 mm (H) X 1.5 mm (T)
50
-
-
... More
Providing and fixing of self illuminated / auto glow "EXIT" signs, with LED & in built power back up for atleast 3 hours printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 300 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site. (at each tower staircase from ground floor to terrace.)
36
-
-
... More
Supplying , Installation ,Testing and Commissiong Supplying , Installation ,Testing and Commissiong Fire Alarm sounder & speaker having an audible range of 25 meters with line matching transformers complete as required. AD 502 LMT
21
-
-
... More
Supplying , Installation ,Testing and Commissiong of Power / Booster Amplifier, 160 W PA with PA Rack complete fwith selection switch with power supply + battery charger battery housing and battery to be precured locally. PA CONSOLE complete as required.
1
-
-
... More
Supplying and Installation Power Supply, 05 Amp. 24v DC complete as required.
4
-
-
... More
SUB HEAD - III SURVILLANCE SYSTEM 4MP IR Outdoor PTZ Camera-1/2.8" progressive scan CMOS, 1920 × 1080 at 25fps, 4.8 mm to 120 mm, 25× optical zoom, 16x digital zoom, 0.005 Lux at F1.6, ICR, ONVIF, support H.265/ MJPEG, Digital WDR, 3D Digital Noise Reduction, BLC, HLC, Defog, EIS, three stream, 24VAC and Hi-PoE, IR range: 150m, Pan Speed - from 0.1°/s to 160°/s, Preset Speed: 240°/s, Tilt Speed- from 0.1°/s to 120°/s, Preset Speed: 200°/s, Presets- 300, Alarm Input-2-ch alarm input, Alarm Output-1-ch alarm output, Audio-1 channel input & output, Support on-board storage up to 256 GB (SD card not included), IP66, Line crossing detection, intrusion detection, face detection, Motion Detection, Video Tampering, UL, CE, FCC certified.
2
-
-
... More
4MP IP Varifocal Bullet Camera: 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm to 12mm Motorized lens, 0.005 Lux at F1.2, ICR, ONVIF, support H.265/MJPEG, 120dB Wide Dynamic Range, BLC, 3D Digital Noise Reduction, 12 VDC & PoE (802.3at), IR range: 50m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Line crossing detection, intrusion detection, Motion detection, face detection, video tampering, UL, CE ,FCC certified.
14
-
-
... More
4MP IP Fixed Dome Camera: 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, ICR, ONVIF, support H.265/MJPEG, 120dB Wide Dynamic Range, BLC, 3D Digital Noise Reduction, 12 VDC & PoE (802.3af), IR range: 30m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Line crossing detection, intrusion detection, Motion detection, face detection, video tampering, UL, CE ,FCC certified.
3
-
-
... More
Supply, Installation, Testing & Commissioning of enterprises level layer 2 with fully manageable, (16) 10/100/1000 RJ45 Ports, (4) SFP ports, (2) Combo 10/100/1000 ports and external RPS connector, complete as per specification and as desired by EJC. Make- Cisco/ Extream/Dlink/Netgear
3
-
-
... More
Supply & Erection of locale 9/12 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc. complete as per specification and as desired by EJC. Make- APW/Rittal/Legrand
3
-
-
... More
Supply & Erection of cat 6 cable, 16 Port jack panel for termination of cat 6 cable, testing & certification of the network with omni panta scanner of each cable. Make- Dlink/Krone/ Schnider.
3
-
-
... More
Supply & erection of cat 6, 1 meter patch cords complete as per specification and desired by EIC. Make-AMP/Krone/Schinder.
20
-
-
... More
Supply & erection of cat 6, 3 meter patch cords complete as per specification and desired by EIC. Make-AMP/Krone/Schinder.
20
-
-
... More
32 Ch Smart Network Video Recorder : Connect Up to 32 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, HDMI 4K resolution / VGA 2mp resolution Output , Support H.265/ MJPEG, Incoming Bandwidth 256Mbps, 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD upto 6TB, front panel: 2 × USB 2.0 rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. With 8TB Surveillance HDD
1
-
-
... More
8 Ch NVR Integrated 8 port POE switch, H.264 upto 5 MP per channel, HDMI, 2SATA with 32 TB meaning 8 channel will have 1 hard disc of 4 TB each (4x8=32 TB). OEM Integrated HDD.
1
-
-
... More
8 Port L2, POE Switches with at least 2 Gig uplink port
3
-
-
... More
SITC of Managed Layer 3 intelligent ethernet central switch providing 24 unpopulated 1000base SFP with min 2 unpopulated SFP upgradable to 10Gbp SFP+, 1 fixed AC power supply and option for RPS with following specifications interface requirements minimum of 24 ports of 1000 base SFP with 4 X shared 100/1000base-X unpopulated SFP with 10/100/1000 base T SFP supporting 1000SX, 1000LX, 1000BX, 10G SR/LR, and 100 FX interfaces, Switch should support 2 X 10Gbps SFP+ fully activated ports additional and exclusive to above required ports sfp+ ports shall be enabled for 10G operation if licence is required, should have USB port for image backup and storage should have dedicated and exclusive stacking ports with stack bandwidth of 40 Gbps and minimum 8 units per stack support any license or cables to be required needs to be provided on day 1, have redundant power supply support and variable speed fan to adjust to varying weather conditions in campus.
1
-
-
... More
SITC of 40” flat screen HD professional LFD (24X7) with interfaces include HDMI, DVI, D-sub, component and composite input as well as RS-232C and RJ45 for extensive connectivity, remote control and wall mount unit/ floor stand complete with marking connection etc complete as reqd.
3
-
-
... More
Supplying and drawing of UTP4 pair cat-6 Lan armoured cable in the ground, including the cost of digging & back filling of the trenches, sand cusioning & protective layer of bricks etc., as required.
3500
-
-
... More
Providing 24 hrs x 365 days operation and maintenance of all the above referred systems complete in all respects including deploying necessary operation and maintenance staff during defects liability period i.e First Year after completion of the work.
1
-
-
... More
Providing 24 hrs x 365 days operation and maintenance of all the above referred systems complete in all respects including deploying necessary operation and maintenance staff after defects liability period / Gurantee period including all spares consumable etc. as required.
1
-
-