Housing And Urban Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Housing And Urban Development Department - HAUDD Tender
Security and Emergency Services
Eprocure
Opening Date25 Jun 2024
Closing Date15 Jul 2024
Tender Amount₹ 33,44,000
Costs
EMD
₹ 66,880Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HAUDD_251151_1Bid Award Id
ViewTender No
JDA-I/2024-25/e-NIT/07 Dated 25.06.2024Tender Authority
Housing And Urban Development Department ViewPurchaser Address
-Website
http://http://jkhudd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
c) 80 mm dia
20
-
-
Same as above but for over ground M.S Pipes (B class) including cutting holes & chases in bricks or RCC wall/slab & Making good the same. Painting with one coat of primer and two coats of synthetic enamel of approved shade of following sizes: ( mtr )
(Payment to be made as per actual measurements.)
-
-
-
a) 150 mm dia
35
-
-
b) 100 mm dia
50
-
-
c) 80 mm dia
25
-
-
c) 25 mm dia
25
-
-
SITC of single headed oblique pattern hydrant SS Landing valve with 80mm dia flanged inlet and 63mm dia Instantaneous type female outlet complete with cap and all Accessories ISI marked.
15
-
-
Supply of non – percolated flexible hose RRL 63 mm dia x 15 mtr long complete with instantaneous type 63 mm dia male and female ISI market coupling and riveted to hose pipe with rivets and copper wire and ISI marked.
30
-
-
Supply and Installation of gunmetal 63 mm dia short branch Pipe with 20 mm dia nozzle.
15
-
-
SITC of first aid hose reel wall mounting swinging type complete with drum and brackets, 25 mm dia ball valve and 20 mm dia 30 mtr long hose pressure pad hose with shut off nozzle complete as required.
10
-
-
SITC of cast iron double flanged ISI marked butterfly valve complete with rubber insertion, nuts, bolts, washers and tested to to minimum of 20 kg / sq cm pressure, of the following sizes:
-
-
-
a) 150 mm dia
9
-
-
b) 100 mm dia
7
-
-
c) 80 mm dia
18
-
-
SITC of following accessories:
-
-
-
a) 25mm dia spring loaded air release valve
3
-
-
b) Pressure Guage
4
-
-
c) 25 mm dia ball valve
4
-
-
d) Pressure Switch
3
-
-
SITC of cast iron double flanged ISI marked NRV complete with rubber insertion, nuts, bolts, washers etc. of following sizes:
-
-
-
a) 150 mm dia
4
-
-
b) 80 / 100 mm dia
4
-
-
SITC of gunmetal Fire Brigade connection with collecting head 63mm,4 way instantaneous type male couplings with flanged outlet complete with blank caps nuts, bolts & rubber insertions, conforming IS:904-1983
1
-
-
SITC of automatic control panel for operation of Jockey pump ,Main Pump and diesel pump fabricated made up of CRCA M.S. Sheet Construction with Red Oxide Primer and finally with approved colour paint. Panel should have Following Components in build:-
INCOMING
a)Copper Bus bar 400 Amps 1 set .
b)CPRI approved,(IP:54) (50 KA breaking Capacity ) 300 Amp MCCBMicro processor type Based with Breaking Capacity 50 KA (Icu=Ics=100%(01 Nos.)
c)Indicating Lamps RYB (1Nos.),ON ,OFF,Trip Indicating lamps d) Digital VAF meter (1Nos.) 0-500 volts
e)Digital Ammeter (0-250) with selector switch and CT etc
f )KWH meter (1 Nos.)
OUT GOING ALL out going feeder for for pumps should have digital Ammeter with selector switch and led type on ,off,triop indicating lsamps Jockey Pump P/F of Automatic 15 hp DoL Starter for operation of Motor of Jockey pump . MCCB 32 A,50 KVA Ics 100% ,Protection IP 54-IP55,Voltage 3 phase,(380-415 volt) Force start operation with manual test function . starter should have Contractor of M/MNX type with minimum rating to operate motor up to 20 hp ,Panel should have protection against ,overload , over Voltage ,low voltage , Single phase preventor , Earth Fault , Phase Imbalance.Water Line controller Should have Auto Restart Stop function depending upon fire line pressure setting of pressure limit switch installed at delivery line and all other necessary devices The ammeter & voltmeter shall also be provided. DOL shall also have all accessories and internal wiring required for automatic operation ,selector switch for local/remote,automatic/manual/off operation with HRC fuses/MCBs for protection of internal wiring. Main Fire Pump :Star Delta Starterautomatic dry type starter for operation of Motor of main fire pump up to 60 Hp.
MCCB 125 A,50 KVA Ics 100% ,Protection IP 54-IP55,Voltage 3 phase,(380-415 volt) Force start operation with manual test function. starter should have three Contractor of M L /MNX type with rating to operate 60 hp motor on full load ,Panel should have Timer for star delta time setting , protection against overload , over Voltage ,low voltage , Single phase preventor , Earth Fault , Phase Imbalance.Water Line controller, Should have Auto Restart Stop function depending upon fire line pressure setting of pressure limit switch installed at delivery line and all other necessary devices The ammeter & voltmeter shall also be provided. ll accessories and internal wiring required for automatic operation ,selector switch for local/remote,automatic/manual/off operation with HRC fuses/MCBs for protection of internal wiring.
Diesel Engine Control Control for Diesel Engine Comprising of Automatic /Manual selector Switch & 3 attempts starting device timers and relays as required ,push buttons ,start/stop in manual mode and Engine on indication.Indicating Lamp for high and low lub oil pressure ,high water temp and engine on indication.
Battery charger suitable for 12 V/24 V DC with boost and trickle selector switch 0-30 V DC voltmeter and 0-20 A Ammeter All standard relays and accessories for automatic operation of diesel Engine. System Controller :-DSITC of system controller to control operation of main electric fire pump Diesel pump ,Jockey pump in sequence as specification of relays ,timers sensors annunciation window for fault indication ,compete as per specification The Panel should be cubical compartmentalized type with separate cable / Busbar Chamber. The Control terminals & Power terminals should be separated and necessary ferrule markings. Necessary M.S. channel/angle for the foundation shall be provided. The Bus bar calculation shall be made for 1 Amp / mm² for Aluminum. The apparatus and circuits in the panels shall be so arranged as to facilitate their operation and maintenance and at the same time to ensure the necessary degree of safety. Provision shall be made in the panel for terminating the incoming cables as required in the single line diagram. Only Top entries shall be permitted and all cables shall be provided with cable terminations. Provision shall also be made for permanently earthing the frames and other metal parts.
1
-
-
Supply and laying of 3½ core armoured 10 sq. mm aluminum cable from motor to electric panel for automation of the jockey pump.
24
-
-
Supplying & lying of 3.5 core armoured 35 sq mm Aluminum cable frommotor to electrical panel for automation of the system.
30
-
-
DIESEL Fire Pump:
SITC of Diesel Driven main fire Pump suitable for automatic operation and consisting of following ,complete in all respect as required
Horizontal type multistage centrifugal pump of cast iron body and bronze impeller with stainless steel shaft , mechanical seal confirming to IS 1520 capacity min 1620 LPM with 70 mtr head with Diesel driven Engine 60 HP 1500 RPM water cooled conforming to IS Standard complete with auto starting mechanism ,12/24 volt electric starting equipment ,diesel tank exhaust pipe extended up to 10 meter outside pump room house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding ,residential silencer ,instruments and protection as per standard specification .stop solenoid for auto stop in the event of fault with auto indications ,painted with post office red colour etc as required along with 125 mm suction and 100 mm delivery P/F of M.S Fabricated base plate , coupling set ,coupling guard ,foundation bolts etc as per requirement .Suitable Cement concrete foundation duly plastered and with anti vibration pads. Job also includes laying of necessary foundations Dampers, laying of suction and delivery line with installation of suitable rating Sluice and NRV in suction and delivery line and interconnection with sump tank and main common delivery line ,
1
-
-
Main Electric Fire Pump: SITC of Electric Driven Fire Pump suitable for automatic operation and consisting of following ,complete in all respect as required. Horizontal type multistage centrifugal pump of cast iron body and bronze impeller with stainless steel shaft , mechanical seal confirming to IS 1520 capacity min 1620 LPM with 70 mtr head Suitable (40-50) HP Squirrel cage,Induction motor TEFC Synchronous speed 1500 rpm/2900 rpm suitable for operation on 415 volt ,3 phase 50 Hz AC supply with IP protection for enclosure ,Horizontal Foot Mounted Type With F class Insulation Conforming to IS -325. P/F of M.S Fabricated base plate, coupling set ,coupling guard ,foundation bolts etc as per requirement .Suitable Cement concrete foundation duly plastered and with anti vibration pads. Job also includes laying of necessary foundations Dampers, laying of suction and delivery line with installation of suitable rating Sluice and NRV in suction and delivery line and interconnection with sump tank and main common delivery line , ,
Jockey pump :
SITC of Electric Driven Jockey Pump suitable for automatic operation and consisting of following ,complete in all respect as required. Horizontal type multistage centrifugal pump of cast iron body and bronze impeller with stainless steel shaft , mechanical seal confirming to IS 1520 capacity 180 LPM with 70 mtr head Suitable (10-15) HP Squirrel cage,Induction motor TEFC Synchronous speed 1500 rpm/2900 rpm suitable for operation on 415 volt ,3 phase 50 Hz AC supply with IP protection for enclosure ,Horizontal Foot Mounted Type With F class Insulation Conforming to IS -325. P/F of M.S Fabricated base plate, coupling set ,coupling guard ,foundation bolts etc as per requirement .Suitable Cement concrete foundation duly plastered and with anti vibration pads. Job also includes laying of necessary foundations Dampers, laying of suction and delivery line with installation of suitable rating Sluice and NRV in suction and delivery line and interconnection with sump tank and main common delivery line ,
1
-
-
Jockey pump :
SITC of Electric Driven Jockey Pump suitable for automatic operation and consisting of following ,complete in all respect as required. Horizontal type multistage centrifugal pump of cast iron body and bronze impeller with stainless steel shaft , mechanical seal confirming to IS 1520 capacity 180 LPM with 70 mtr head Suitable (10-15) HP Squirrel cage,Induction motor TEFC Synchronous speed 1500 rpm/2900 rpm suitable for operation on 415 volt ,3 phase 50 Hz AC supply with IP protection for enclosure ,Horizontal Foot Mounted Type With F class Insulation Conforming to IS -325. P/F of M.S Fabricated base plate, coupling set ,coupling guard ,foundation bolts etc as per requirement .Suitable Cement concrete foundation duly plastered and with anti vibration pads. Job also includes laying of necessary foundations Dampers, laying of suction and delivery line with installation of suitable rating Sluice and NRV in suction and delivery line and interconnection with sump tank and main common delivery line ,
1
-
-
SITC of Air vessel 250mm dia and 1.5 mtr high with dished top, made of 6mm thick MS pipe complete with provision for 25 mm dia air release valve, 25mm dia stop valve, 25 mm dia drain valve , pressure gauge& all accessories as req and painted.
1
-
-
Earthwork excavation in trenches including back filling and leveling the top after laying of MS pipe. ( rmt)
150
-
-
Supply & installation of weather proof hose cabinets fabricated from 18 swg MS sheet/section with full front glass door and suitable to accommodate 2 nos 15 mtr long hoses and 1 no branch pipes as req.
12
-
-
Supply, Installation, Testing and Commissioning of UL listed Intelligent Addressable Smoke detector, optical type with blinking LED and standard base, being capable of addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
72
-
-
Supply, Installation, Testing and Commissioning of UL Listed Intelligent Addressable Double action manual pull station, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
8
-
-
Supply, Installation, Testing and Commissioning of UL Listed Fire Alarm Hooter (sound output of minimum 90 dB upto a distance of 30 meters) cum Strobe (Select able 15, 30, 75, or 110 cd).
8
-
-
Supply, Installation, Testing and Commissioning of UL Listed Addressable Fault Isolator module complete as required for determining the short in a circuit and separating the segment having the short capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
4
-
-
Supply, Installation, Testing and Commissioning of UL listed micro processor based 2 wire fault tolerant loop, of following loop capacity (each loop accessing minimum 125 detectors and 125 modules ) fire alarm/detection and voice evacuation control panel with 960 Character LCD Display. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 8 hours with battery charger complete as required. A) 1 Loop panel
1
-
-
S/l of 2 x 1.5 sqmm dia PVC insulated copper conductor armoured cable directly on the surface complete as req.
600
-
-
S/l of 4 x 1.5 sqmm dia PVC insulated copper conductor armoured cable directly on the surface complete as req.
50
-
-
Providing & fixing ABC type fire extinguishers 4 Kg cap. Complete with discharge arrangement, high-pressure hose pipe complete as req.
16
-
-
Providing & fixing CO2 type fire extinguishers 4.5 Kg cap. Complete with wheel valve arrangement, high-pressure wire Braided hose pipe as req.
12
-
-
Supplying & fixing a set of GI fire bucket with round bottom each set comprising of 4 Nos of buckets each of 9 ltr cap. Including fixing suitable brackets in the hook for holding buckets Painted with red paint & filled of sand in 2 buckets of each set.
4
-
-
S/f of 5 kg ABC type modular type ceiling mounted Fire Extinguisher as required
8
-
-
Providing and fixing Lift/Floor and fire signage’s printed on photo luminescent U1000 aluminium sheet of 1.0 mm (+10%) containing Lumigen III as base chemical covered under UV stabilize coating and of appropriate size (Glosign or eq. Make) including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all as directed. ( sqinch )
50
-
-
Comprehensive Annual maintenance contract of the fire fighting system for 2 years after completion of DLP of one year
-
-
-
1st Year
1
-
-
2nd Year
1
-
-
Evaluation Notes How It Works ?