Housing And Urban Development Department Tender

... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Housing And Urban Development Department - HAUDD Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Jul 2024
Closing Date31 Jul 2024
Tender Amount₹ 25,01,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
20HP,1450 rpm of 2-cusec pumping unit

1

11200

11200

... More
30HP,1450 rpm of 3-cusec pumping unit

1

15200

15200

... More
50HP,1450 rpm of 5-cusec pumping unit

1

36400

36400

... More
75 H.P,950 rpm of 5-cusec pumping unit

1

48500

48500

... More
100HP,1450 rpm of 10-cusec pumping unit

1

66500

66500

... More
Rewinding of AC induction motors coupled to Horizontal shaft disposition sewage pumping units of make Kirloskar/ Flowmore/Mather & Platt as and when required to by way of decoupling of damaged 3-phase motor from the pump motor assembly at site. Shifting the decoupled motor from site to the workshop in a private load carrier to be arranged by the firm .At workshop the motor shall be dismantled by way of opening all nuts, bolts, cover plates etc and the damaged/burnt out windings shall be extracted from all stator slots by special tools & tackles, skilled manpower. After extraction of the windings from the stator the same shall be rewound by using insulated Cu-wire of proper gauge and specification and as per actual pitch and turns. The job includes insulation of the windings by proper insulating material, tape etc and assembling back of rotor, stator, cover plates, all nuts and bolts of the motor. The repaired motor shall be shifted back to site from workshop in a load carrier to be arranged by the firm and at site the motor shall be re-coupled with the pump. All power connections shall be reconnected with the motor with tightening all the nuts and bolts. The unit shall be tested on full load The rewound motor shall have defect liability period of six months from the date of its repairs / Replacements. Note: The old copper shall be retained by the firm &firm shall quote the rates with rebate on account of old copper scrap.

-

-

-

... More
120 Hp,950 rpm Prime mover

1

86500

86500

... More
100 Hp,950 rpm Prime mover

1

75500

75500

... More
75Hp,950 rpm Prime mover

1

51500

51500

... More
60 Hp,1450 rpm Prime mover

1

33900

33900

... More
50 Hp,1450 rpm Prime mover

1

27200

27200

... More
30 Hp,1450 rpm Prime mover

1

18200

18200

... More
20 Hp,1450 rpm Prime mover

1

13250

13250

... More
12.5 Hp,1450 rpm Prime mover

1

10200

10200

... More
7.5 Hp,1450 rpm Prime mover

1

6500

6500

... More
5 Hp,1450 rpm Prime mover

1

5350

5350

... More
3 Hp,1450 rpm Prime mover

1

4250

4250

... More
1.5Hp,1450 rpm Prime mover

1

1950

1950

... More
Providing & fitting of new bearings including applying of grease to the bearings in adequate quantity

-

-

-

... More
6204 Deep groove Ball bearing

1

320

320

... More
6205 Deep groove Ball bearing

1

450

450

... More
6305 Deep groove Ball bearing

1

490

490

... More
6308 Deep groove Ball bearing

1

1050

1050

... More
6309 Deep groove Ball bearing

1

1850

1850

... More
6310 Deep groove Ball bearing

1

2050

2050

... More
6311 Deep groove Ball bearing

1

2600

2600

... More
6312 Deep groove Ball bearing

1

2750

2750

... More
6314 Deep groove Ball bearing

1

3950

3950

... More
6315 Deep groove Ball bearing

1

5400

5400

... More
6316 Deep groove Ball bearing

1

5850

5850

... More
6319 Deep groove Ball bearing

1

10500

10500

... More
6408 Deep groove Ball bearing

1

6450

6450

... More
6411 Deep groove Ball bearing

1

7300

7300

... More
3213-BD-XL Angular Contact Ball bearing

1

10400

10400

... More
3313-BD-XL Angular Contact Ball bearing

1

19900

19900

... More
NU 206 Cylindrical roller bearing

1

6800

6800

... More
NU2319 Cylindrical roller bearing

1

31900

31900

... More
7312 Angular Contact Ball bearing

1

18800

18800

... More
3216 Angular Contact Ball bearing

1

16590

16590

... More
5314 Angular Contact Ball bearing

1

9150

9150

... More
Replacement of damaged fans by way of providing & fitting of new Aluminum construction fans as per old sample. The fans shall have defect liability period of six months from the date of its repairs/replacements.

-

-

-

... More
75H.P -100 Hp,950 rpm Prime mover

1

14500

14500

... More
50H.P-60 Hp,1450 rpm Prime mover

1

10500

10500

... More
Replacement of damaged fans by way of providing & fitting of new fan of plastic construction as per old sample.

-

-

-

... More
30HP -40 Hp,1450 rpm Prime mover

1

1450

1450

... More
20 HP-25 Hp,1450 rpm Prime mover

1

1050

1050

... More
5H.P-7.5 Hp,1450 rpm Prime mover

1

650

650

... More
3 Hp,1450 rpm Prime mover

1

450

450

... More
Repairs to the motor shield at bearing location by way of re-metaling of the bearing seat and finishing the same to desired level so that the bearings are seated properly.The job also includes to and fro carriage of Motor shield. The job shall have defect liability period of six months from the date of its repairs/replacements.

-

-

-

... More
100 Hp,950 rpm Prime mover

1

3000

3000

... More
50HP- 60 Hp,1450 rpm Prime mover

1

2550

2550

... More
30HP-40 HP,1450 rpm Prime mover

1

2300

2300

... More
20 HP- 25 Hp,1450 rpm Prime mover

1

2000

2000

... More
5HP-7.5 Hp,1450 rpm Prime mover

1

1500

1500

... More
Replacement of connection from the winding to connection plate of the three phases of the motor.

1

1185

1185

... More
Providing and filling of lubricating oil SAE 10W-ISO Grade 32( Turbo T-32 / ISV VG32) into the casing cover of submersible motors. The oil used shall be highly refined straight mineral product of highly de-miscibility, free from running and acid foaming tendencies.

1

310

310

... More
Re-metaling of rotor shaft, turning and finishing to proper size for tight fitting of bearing.

-

-

-

... More
Motor Rating from 5 HP to 15HP

1

1650

1650

... More
Motor Rating from 20 HP up to 50 HP

1

2800

2800

... More
Motor Rating from 60 HP up to 75 HP

1

3500

3500

... More
Motor Rating from 100 HP up to 120HP

1

4450

4450

... More
Providing and fitting of Strip along the length of guide pipe after removing the damaged one

-

-

-

1

850

850

1

170

170

... More
Providing and fitting of suitable diameter GUIDE PIPE after removing the damaged one SS (Thickness 5mm)

1

850

850

... More
Providing and fitting of suitable diameter GUIDE PIPE after removing the damaged one G.I (C Class):

-

-

-

... More
1 inch dia

1

750

750

... More
1-1/2 inch dia

1

1080

1080

... More
2 inch dia

1

1450

1450

... More
2—1/2 inch dia

1

1780

1780

... More
Providing and fitting of MECHANICAL SEAL (inboard & Outboard) after removing the damaged one.

-

-

-

... More
Kirloskar03H.P-05 H.P

1

4500

4500

... More
Kirloskar 20H.P-30 H.P.

1

7500

7500

... More
Kirloskar 50H.P

1

10300

10300

... More
Kirloskar 100H.P

1

12800

12800

... More
KSB 20H.P-30 H.P.

1

7200

7200

... More
KSB50H.P

1

9800

9800

... More
KSB 100H.P

1

11900

11900

... More
Darling 20 H.P.

1

7200

7200

... More
Xylum 30H.P.

1

7800

7800

... More
Xylum 7.5H.P-15 H.P.

1

5440

5440

... More
Xylum 03H.P-05 H.P.

1

4500

4500

... More
Providing , fitting, testing and commissioning of on load change over switches confirming to IEC:60947-3; IS:13947 as and when required during contract period of makes L & T/ Siemens/ Havells as per the ratings given below after removing of old damaged change over switches with defect liability period of 06 months.

-

-

-

... More
63 A, 4 pole, open execution on load Changeover switch

1

5250

5250

... More
125 A, 4 pole, open execution on load Changeover switch

1

8630

8630

... More
125 A, 4 pole, with enclosure on load Changeover switch

1

12400

12400

... More
160 A, 4 pole, open execution on load Changeover switch

1

9600

9600

... More
160 A, 4 pole, with enclosure on load Changeover switch

1

12980

12980

... More
200 A, 4 pole, open execution on load Changeover switch

1

11200

11200

... More
250 A, 4 pole, open execution on load Changeover switch

1

16600

16600

... More
400 A, 4 pole, open execution on load Changeover switch

1

26500

26500

... More
630 A, 4 pole, open execution on load Changeover switch

1

31200

31200

... More
800 A, 4 pole, open execution on load Changeover switch

1

45400

45400

... More
Providing, fitting, testing and commissioning of three pole and neutral, AC-23 A, 50 Hz, 415 V switch disconnector fuse unit, confirming to IS: 13947 (part I & III) as and when required during contract period of make L&T/ Siemens/ Havells as per the ratings given below after removing of old damaged switch disconnector fuse unit with defect liability period of 06 months.

-

-

-

... More
125 A (Open Execution)

1

8650

8650

... More
125 A (with enclosure)

1

10650

10650

... More
250 A (Open Execution)

1

15850

15850

... More
250 A (with enclosure)

1

18300

18300

... More
Providing and fitting of HBC Fuse Links as and when required during contract period confirming to IEC 60269-1 & 2/ I/S-13703-1 & 2-1 as per the ratings given below after removing old damaged HBC fuse links with defect liability period of 06 months.

-

-

-

... More
40 A, 80 KA, 415 V

1

145

145

... More
60/63 A, 80 KA, 415 V

1

495

495

... More
125 A, 80 KA, 415 V

1

575

575

... More
250 A, 80 KA, 415 V

1

1030

1030

... More
Providing, fitting, testing and commissioning of three pole contactors with AC coils as and when required during contract period confirming to IEC: 13947 & IS: 13947 of make L&T/ Siemens as per the ratings given below after removing old damaged contactors with AC coils with defect liability period of 06 months:

-

-

-

... More
3 pole Ie 18A, Ith 25 A

1

1120

1120

... More
3 pole Ie 25A, Ith 32A

1

1390

1390

... More
3 pole Ie 32A, Ith 40 A

1

2900

2900

... More
3 pole Ie 40A, Ith 45A

1

4350

4350

... More
3 pole Ie 50A, Ith 85 A

1

5800

5800

... More
3 pole Ie 75A, Ith 100A

1

8600

8600

... More
3 pole Ie 85A, Ith 100A

1

10200

10200

... More
3 pole Ie 100 A, Ith 160 A

1

14900

14900

... More
3 pole Ie 110A, Ith 160 A

1

18800

18800

... More
3 pole Ie 150A, Ith 160A

1

23700

23700

... More
3 pole Ie 185A, Ith 250 A

1

27100

27100

... More
3 pole Ie 225A, Ith 300 A,

1

33100

33100

... More
Providing, fitting, testing and commissioning of manual reset electronic overload relays as and when required during contract period of make L&T/ Siemens/ Havells and having relay range as given below after removing old damaged electronic overload relays with defect liability period of 06 months.

-

-

-

... More
14-23 A

1

1760

1760

... More
20-33 A

1

2410

2410

... More
30-50 A

1

3450

3450

... More
45-75 A

1

4300

4300

... More
48-80 A

1

6900

6900

... More
60-100 A

1

7550

7550

... More
90-150 A

1

7750

7750

... More
135-225 A

1

8400

8400

... More
180-300 A

1

9950

9950

... More
Providing, fitting, testing and commissioning of direct online starters as and when required during contract period of make L&T/ Siemens/ Havells confirming to IS: 13947-4 of ratings given below after removing old damaged direct online starters with defect liability period of 06 months.

-

-

-

... More
5 Hp with contactor rating 12Amp and overload relay range 7-10 A.

1

2950

2950

... More
7.5 Hp with contactor rating 15Amp and overload relay range 13-22 A.

1

4650

4650

... More
Providing and fitting of 1.1 KV, three and half core, XLPE insulated, Aluminum Armored cables as and when required during contract period confirming to IS: 7098 (part-I), 1988 as per the details below after removing damaged cables from cable trays and cable trenches. The cables shall have defect liability period of 06 months.

-

-

-

... More
25 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

255

255

... More
35 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

325

325

... More
50 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

435

435

... More
70 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

575

575

... More
95 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

715

715

... More
120 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

865

865

... More
185 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

1305

1305

... More
400 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

2630

2630

... More
630 mm2, 3.5 core, XLPE insulated, Aluminum Armored cable

1

3250

3250

... More
Providing and fitting of 1.1 KV, three core, PVC/ XLPE insulated, copper Armored cables confirming to IS: 7098 (part-I), 1988 as per the details below after removing damaged cables from cable trays and cable trenches.

-

-

-

... More
4 mm2, 3 core, PVC/XLPE insulated, copper Armored cable

1

285

285

... More
6 mm2, 3 core, PVC/ XLPE insulated, copper Armored cable

1

390

390

... More
16 mm2, 3 core, PVC/ XLPE insulated, copper Armored cable

1

910

910

... More
25 mm2, 3 core, PVC XLPE insulated, copper Armored cable

1

1380

1380

... More
Providing and fitting of 1.1 KV, Single Core, PVC insulated, unarmored copper conductor as and when required during contract period confirming to IS: 7098 (part-I), 1988 as per the details below after removing damaged cables from cable trays and cable trenches. The cables shall have defect liability period of 06 months.

-

-

-

... More
1.5 mm2, Single core, PVC insulated, copper unarmored cable

1

25

25

... More
2.5 mm2, Single core, PVC insulated, copper unarmored cable

1

42

42

... More
1 mm2, Single core, PVC insulated, copper unarmored cable

1

18

18

... More
Providing and fitting of aluminum lugs/ thimbles as and when required during contract period confirming to BS EN 61238 after replacement of damaged aluminum lugs/ thimbles from aluminum cables. The size of the lugs/ thimbles is given here under:

-

-

-

... More
16 mm2

1

5

5

... More
25 mm2

1

6

6.5

... More
32 mm2

1

8

8

... More
50 mm2

1

12

12

... More
70 mm2

1

18

18

... More
95 mm2

1

19

19.5

... More
120 mm2

1

28

28

... More
150 mm2

1

36

36

... More
185 mm2

1

46

46

... More
300 mm2

1

108

108

... More
400 mm2

1

160

160

... More
630 mm2

1

300

300

... More
Providing and fitting of copper lugs/ thimbles as and when required during contract period confirming to BS EN 61238 after replacement of damaged copper lugs/ thimbles from copper cables. The size of the lugs/ thimbles is given here under:

-

-

-

... More
1.5 mm2

1

3

3

... More
2.5 mm2

1

4

4

1

8

8.5

1

10

10

... More
10 mm2

1

12

12

... More
16 mm2

1

18

18

... More
25 mm2

1

23

23.5

... More
35 mm2

1

29

29

... More
50 mm2

1

36

36

... More
Providing and fitting of miniature circuit breakers of makes L&t/ Siemens/ Havells/ GM for lighting system of pump stations, STP, administrative block, Divisional office, Circle office and Direction office after removing damaged MCBs from the lighting system, as per the specifications given below(as and when required during contract period): The miniature circuit breakers shall have defect liability period of 06 months.

-

-

-

... More
Single pole, 6 A MCB

1

180

180

... More
Single pole, 10 A MCB

1

180

180

... More
Single pole, 16 A MCB

1

180

180

... More
Single pole, 20 A MCB

1

180

180

... More
Single pole, 32 A MCB

1

180

180

... More
Double pole, 40 A MCB

1

1120

1120

... More
Double pole, 63 A MCB

1

1250

1250

... More
Three pole, 63 A MCB

1

1350

1350

... More
Providing and fitting of single phasing preventers with system supply 415 VAC, 50 Hz of make L&T/ Siemens as and when required during contract period. The preventer is to be provided and fitted after removing damaged single phasing preventer from starter panel. The single phasing preventer shall have defect liability period of six months. The single phasing preventers are to be provided and fitted in starter panels of motor ratings 20 Hp, 30 Hp, 40 Hp, 50 Hp, 60 Hp, 75 Hp, 100 Hp and 120 Hp.

1

1950

1950

... More
Providing , fitting, testing and commissioning of moulded case circuit breakers (AC 415 V) as and when required during contract period of makes L & T/ Siemens/ Havells /Schneider electric conforming to IEC:60947-11/IS:13947-11 as per the ratings given below after removing old damaged MCCBs from panels. The MCCBs shall have defect liability period of 06 months.

-

-

-

... More
63 A, 25 KA, 3 Pole MCCB

1

3750

3750

... More
100 A, 25 KA, 3 Pole MCCB

1

3900

3900

... More
125 A, 25 KA, 3 Pole MCCB

1

5250

5250

... More
160 A, 25 KA, 3 Pole MCCB

1

6550

6550

... More
200 A, 36 KA, 4 Pole MCCB

1

19500

19500

... More
250 A, 36 KA, 4 Pole MCCB

1

17800

17800

... More
400 A, 36 KA, 4 Pole MCCB

1

22500

22500

... More
630 A, 36 KA, 4 Pole MCCB

1

35400

35400

... More
800 A, 85 KA, 4 Pole MCCB

1

58300

58300

... More
Providing and fitting of 0-200 A moving iron, fixed coil, square dial industrial type ammeters to the panel boards of various motors of pumping units and equipment’s. The job includes cost on account of additional wiring after connections and removing of damaged ammeters from the panels. The preferable makes of ammeters are AE/ EE and shall have defect liability period of 06 months (as and when required during contract period).

1

550

550

... More
Providing and fitting of 0-500 V moving iron, fixed coil, square dial industrial type voltmeters to the panel boards of various motors of pumping units and voltage stabilizers (as and when required during contract period). The job includes cost on account of additional wiring for connections and shall have defect liability period of 06 months. The preferable makes of voltmeters are AE/EE.

1

670

670

... More
Providing and fitting of electronic timer with input supply of 415 VAC, timing range of 13-18 Seconds of L&T or Siemens make within starter panels after removing of damaged timers from panels of pumping units with defect liability period of 06 months (as and when required during contract period).

1

1650

1650

... More
Earthing of electro-mechanical equipment’s through excavation of trenches and burying 02 numbers Galvanized iron plates of 600 x 600 x 6 mm vertically below 3-meters round surface. Connecting these plates through GI strip of size 50mm x 6 mm with the equipments and filling of trenches by means of charcoal and salt as per instructions of engineer in charge. Providing a fitting of 25mm dia GI pipe for maintaining moist conditions with wire mesh as per guide lines provided in standard codes practice IS: 3043 for earthing of equipment’s(as and when required during contract period).

1

7500

7500

... More
Providing of the services of qualified electrician for undertaking repairs and replacements of lighting/ heating circuits within pump stations, STP, administrative block, divisional office, circle office and direction office(as and when required during contract period).

1

1250

1250

... More
Providing and fitting of 180 AH batteries for DG Sets installed within pump station and 17.08 MLD STP (Brarinambal). The old batteries are to be retained by the contractor. The preferable make for the batteries is EXIDE (as and when required during contract period).The batteries shall have defect liability period of six months from the date of its repairs/replacements.

1

18500

18500

... More
Providing and fitting of various electrical fittings as under(Preferred makes: Anchor/ SSK/ Havells)

-

-

-

... More
Switch-6A-SP-1way, 240V, 50 Hz, AC.

1

35

35

... More
Switch-6A-SP-2way, 240V, 50 Hz, AC.

1

65

65

... More
6A-2/3 pin-universal socket, 240V, 50 Hz, AC.

1

40

40

... More
Fan regulator (Mini) with rotary step

1

240

240

... More
Plug Top 15/16A 3 Pin (ISI Marked)

1

140

140

... More
32A TP switch 415V with neon

1

1150

1150

... More
32A DP switch 240V with neon

1

790

790

... More
Providing, Fixing, Testing of 6A ceiling rose

1

40

40

... More
Providing and installation of Pendant/ angle/ batten holders 6A 240V

1

48

48

... More
Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells

-

-

-

1

850

850

1

1130

1130

... More
Providing and installation of 100A 4P isolator(Preferred Make: L&T/Legrand/Havells

1

2150

2150

... More
Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T)

-

-

-

... More
2-pole 16A 240V

1

950

950

... More
2-pole 32A 240V

1

1580

1580

... More
4-pole 32A 240V

1

2250

2250

... More
Providing and installation of Bus bar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T)

-

-

-

... More
63A 415V

1

4200

4200

... More
100A 415V

1

5100

5100

... More
200A 415V

1

6800

6800

... More
Providing and installation of various type of fans as under:(Preferred makes: Havells/ Orient/ Crompton)

-

-

-

... More
Exhaust fan 200mm Plastic

1

1950

1950

... More
Exhaust fan 250mm Plastic

1

2250

2250

... More
Ceiling fan 1200mm sweep

1

2750

2750

... More
LED Bulbs with E27 or B22 base and illumination 3000K/ 5700K/ 6500K(Preferred makes: Philips/ Osram/ Crompton/ Syska

-

-

-

1

165

165

1

225

225

1

280

280

... More
Street-lighting: Outdoor pressure die-cast aluminum IP66 luminaries (streetlight) with high power LED as light source(Preferred makes: Havells/ Philips/ Crompton)

-

-

-

1

1350

1350

1

1820

1820

1

2150

2150

... More
Portable light 3 W Rechargeable LED torch (Preferred make: Havells/ Eveready/ Andslite/ Philips

1

850

850

... More
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The mats shall be as per IS 15652:2006 & shall have the following specifications: Composition: Rubber (synthetic mats for electrical purpose) Thickness: 2.5mm Size:1 M wide. The rubber mats shall be accepted with manufacturers test certificate.

1

1350

1350

... More
Providing and fitting of 1.5 ton rotary AC compressor for Godrej/LG Air conditioner

1

16500

16500

... More
Refilling of 1.5 ton rotary AC compressor for Godrej/LG Air conditioner

1

2950

2950

... More
Providing of the services of qualified instrumentation electrician/AC technician for undertaking repairs and replacements of panels/Air conditioners (as and when required during contract period).

1

1850

1850

... More
B) Servo Voltage Stabilizers and Manual Voltage Stabilizers Repairs to Servo type, 3 Phase / single phase, 415V / 220V, 50Hz voltage stabilizer by way of:- Complete dismantling of the servo voltage stabilizer after disconnecting it from the circuit. The necessary tools and tackles required for the job are to be arranged and brought to the site by the contractor. The job also includes temporary arrangement of gantry/tripod stand at the site by the contractor. Dismantling of the core and then removing of old/damaged coil(s) from it at the workshop.

-

-

-

... More
400kVA

1

4250

4250

... More
200kVA

1

3100

3100

... More
150kVA

1

2700

2700

... More
125kVA

1

2250

2250

... More
100kVA

1

2000

2000

1

1500

1500

... More
Rewinding of new coil(s) in suitable gauge, standard quality aluminum wire/strip, applying superior quality insulating varnish in sufficient quantity to rewound coil(s) and drying them by suitable means. Providing and fitting of lethoride sheets, cotton tape etc., and refitting the coil(s) in the core is included in the job. Fitting back the core–coil assembly in the oil bath. The servo stabilizer rating are in the range of 400KVA-25KVA.

1

485

485

... More
Rewinding of new coil(s) in suitable gauge, standard quality copper wire/ strip, applying superior quality insulating varnish in sufficient quantity to rewound coil(s) and drying them by suitable means. Providing and fitting of lethoride sheets, cotton tape etc., and refitting the coil(s) in the core is included in the job. Fitting back the core–coil assembly in the oil bath. The servo stabilizer rating are in the range of 400KVA-25KVA.

1

775

775

... More
Providing & fitting of aluminum connection leads from dimmer to coils and from incoming bush rods to dimmer including applying of cotton tape impregnation etc. The rates includes rebate on old scrap to be retained by the contracting agency.

1

485

485

... More
Providing& fitting of new Variac / Dimmer(Copper) of adequate capacity and superior quality in place of old damaged one

-

-

-

... More
400kVA for one dimmer

1

64500

64500

... More
200kVA for one dimmer

1

36500

36500

... More
100 KVA-150kVA for one dimmer

1

27500

27500

... More
25KVA -50KVAfor one dimmer

1

14700

14700

... More
Providing&fittingofArms/BrushholderalongwithCarbonbrushesofeachphasedimmer assembly in place of old damaged one.

-

-

-

... More
400kVA for one Arm/Brush holder along with Carbon brushes

1

4000

4000

... More
100/125/150/200kVA for one Arm/Brush holder along with Carbon brushes

1

1650

1650

... More
25 KVA-50KVA for one Arm/Brush holder along with Carbon brushes

1

1580

1580

... More
Providing & fitting of new Synchronous motor (240V) of dimmer assembly of recommended torque for the requisite servo stabilizer capacity ,in place of old damaged one.

-

-

-

... More
400kVA

1

10500

10500

... More
200kVA

1

8700

8700

... More
100/125/150kVA

1

3200

3200

... More
25/50KVA

1

2550

2550

... More
Providing& fitting of new Control card in place of old damaged one of the servo voltage stabilizer.

1

3850

3850

... More
Providing &fitting of Auxiliary wiring of the servo stabilizer in place of old damaged one.

1

850

850

... More
Providing & filling of transformer oil of required grade and dielectric properties for topping up.

1

155

155

... More
Treatment of T. Oil by way of filtration, boiling etc and washing of oil bath with HSD to remove sludge from it and refilling of the T-oil in the oil bath.

1

21

21

... More
Providing & fitting of (0-500) V range, square dial, Digital Voltmeter along with necessary wiring of the panel of voltage stabilizer after removing damaged one.

1

670

670

... More
Providing and fitting of phase failure protection device &circuit.

1

1350

1350

... More
Providing and fitting of high voltage/ low voltage cutout device & circuit.

1

1350

1350

... More
Providing and fitting of time delay device &circuit.

1

1550

1550

... More
Providing and fitting of overload protection device & circuit

1

1550

1550

... More
Replacement of damaged brass bush rod(s),by way of providing & fitting of heavy-duty, superior quality new brass bush rod(s) along with brass nut(s) /washer(s) /gasket/porcelain insulator of each phase.

-

-

-

... More
400kVA

1

2150

2150

... More
200kVA

1

1350

1350

... More
150kVA

1

1250

1250

... More
125kVA

1

1050

1050

... More
100kVA

1

850

850

1

650

650

... More
Replacement of damaged phase indicators by new neon phase indicators set with low watt consumption including its wiring.

1

35

35

... More
Replacement of damaged Selector switch by new Selector switch including its wiring.

1

297

297

... More
Replacement of insulator of each phase of the voltage stabilizer by new one.

-

-

-

... More
Porcelain

1

95

95

... More
Porcelain

1

95

95

... More
Complete reassembling of the servo voltage stabilizer, reconnecting in the circuit and testing of voltage stabilizer on no load and full load.

-

-

-

... More
400kVA

1

3500

3500

... More
200kVA

1

2800

2800

... More
150kVA

1

2500

2500

... More
125kVA

1

2250

2250

... More
100kVA

1

2000

2000

1

1500

1500

... More
To & fro carriage of voltage stabilizer from site to workshop and back includes its loading and unloading.

-

-

-

... More
400kVA

1

5000

5000

... More
200kVA

1

3000

3000

... More
150kVA

1

3000

3000

... More
125kVA

1

2500

2500

... More
100kVA

1

2500

2500

1

2000

2000

... More
5kVA(Single Phase)

1

600

600

... More
Repairs to Manually operated, 3-Phase, 415V, 50 Hz voltage stabilizer by way of: Rewinding burnt/ damaged windings of voltage stabilizer coil assembly (comprising of three limbs) using superior quality copper wire of proper gauge as per requirement with superior insulation. (The rates are inclusive of rebate on old scrap and old scrap shall be retained by the contracting agency).

-

-

-

... More
5KVA Single phase(automatic)

1

6500

6500

... More
10 KVA single phase

1

10500

10500

... More
15 KVA single phase

1

16500

16500

... More
35 KVA Single Phase

1

24500

24500

... More
30kVA rating three phase

1

7900

7900

... More
40kVA rating three phase

1

11800

11800

... More
50kVA rating three phase

1

13900

13900

... More
75kVA rating three phase

1

15800

15800

... More
100kVA rating three phase

1

21400

21400

... More
150kVA rating three phase

1

29300

29300

... More
200kVA rating three phase

1

34600

34600

... More
400 KVA rating three phase

1

48500

48500

... More
Removing of damaged plate type voltage regulator switch from 3 phase, 415 ±15 % Volt voltage stabilizer and providing and fitting of new plate type voltage regulator switch having copper contact points with 6 steps. the job includes cost on account of skilled/semi-skilled labour required for work

-

-

-

... More
Bakelite plate type(15"x15"size)

1

20500

20500

... More
Bakelite plate type(12"x12"size)

1

9250

9250

... More
Bakelite plate type(10"x10"size)

1

6800

6800

... More
Bakelite plate type(8"x8"size)

1

5250

5250

... More
Rotary,closedplatetype100A

1

1820

1820

... More
Rotary,closedplatetype63A

1

1475

1475

... More
Rotary,closedplatetype32A

1

1250

1250

... More
Providing and replacement of copper contact points on regulator plate

1

1420

1420

... More
Impregnation / heat treatment of winding assembly of 3 phase , 415 ±15 % Volt voltage stabilizer by way of keeping it in an electric oven for about 24 hours and at appropriate temperature.

-

-

-

... More
10 KVA single phase

1

500

500

... More
15/35 KVA single phase

1

1000

1000

... More
30/40/50KVA rating three phase

1

1200

1200

... More
75/100kVA rating three phase

1

1500

1500

... More
150/200 KVA rating three phase

1

2500

2500

... More
400 KVA rating three phase

1

3500

3500

... More
Removing of damaged copper connection terminal bolt with washer and nut from single/3 phase , 415 ±15 % Volt voltage stabilizer and providing and fitting of new copper connection terminal bolt with nut and washer.

-

-

-

... More
10 KVA single phase

1

100

100

... More
15 KVA single phase

1

150

150

... More
35 KVA Single Phase

1

200

200

... More
30kVA rating three phase

1

200

200

... More
40kVA rating three phase

1

200

200

... More
50kVA rating three phase

1

250

250

... More
75kVA rating three phase

1

275

275

... More
100kVA rating three phase

1

300

300

... More
150kVA rating three phase

1

350

350

... More
200kVA rating three phase

1

400

400

... More
400kVA rating three phase

1

800

800

... More
Replacement of M.S frames of the core assembly by way of providing & fitting of new M.S frames of the core assembly as per the old sample. The rate includes a rebate on old scrap to be retained by the contracting agency.

1

145

145

... More
Repairs to the oil bath (tank) of the voltage stabilizer by way of welding at the cracked /damaged Spot and the painting of the same as per the existing colour and coat. The job includes disconnecting incoming and outgoing cable connections and emptying of the tank of the voltage stabilizer.

1

2100

2100

... More
Re-connecting the voltage stabilizer in the circuit and testing of same on no load and full load.

1

1650

1650

... More
Manual Loading, unloading to and fro carriage ,installation after repairs and testing at site of voltage stabilizer of rating:

-

-

-

... More
10 KVA-50kVA

1

3500

3500

... More
75 KVA-150kVA

1

4500

4500

... More
200 KVA-250 KVA

1

5500

5500

... More
Mechanical Loading, unloading to and fro carriage ,installation after repairs and testing at site of voltage stabilizer of rating

-

-

-

... More
400 KVA

1

10500

10500

... More
Providing, fitting, testing and commissioning of single phase voltage stabilizer as per specifications below: Type of voltage controller: Manually operated copper wound, single phase, AC power supply multi step. Type of Regulator: Single plate type with electrolytic copper contacts. Input voltage : 90-110 volts.(single phase) Output voltage: 240 ±10% volts. Frequency : 50 ±3 C/S. Windings : Electrolytic grade copper of adequate section, vacuum impregnated. The voltage stabilizer is to be provided and filled with transformer oil of required grade and dielectric properties.

1

67500

67500

... More
C) Repairs to HT/LT electric substation (33/11 /11/.440 kV) Repairs to HT/LT electric substation (33/11 /11/.440 kV) by way of: Dropping down of the link set of HT line of the sub-station and then disconnecting the various connections of circuitry from HT/LT side. Loading the HT/LT transformer in a private TATA mobile/Truck through a crane/suitable means at the site and Shifting the HT/LT transformer to workshop. Unloading the HT/LT transformer from a private TATA mobile/Truck through a crane/suitable means at the workshop. The job includes arrangement of mechanical aids, highly skilled labors, chain pulley blocks, pullers, channels, link rod etc by the contractor.(The rates are inclusive of rebates on old scrap and old scrap shall be retained by the contracting agency).

-

-

-

1

20500

20500

... More
400 KVA

1

10000

10000

... More
250 KVA

1

7000

7000

... More
100 KVA

1

5000

5000

... More
63 KVA

1

3000

3000

... More
25 KVA

1

2500

2500

... More
Opening of the transformer involving removing of top cover & lifting of the core assembly from the oil tank by means of lifting tools & then checking the internal wirings and the core thoroughly. Dismantling the core strips in order to remove the coils safely and then removing the damaged HT coil(s) and LT coil(s) of phase(s)/leg(s). Fabrication, providing & fitting of new HT/LT coil(s) in place of the damaged coil(s) of phase(s)/ leg(s) in suitable gauge & size

-

-

-

... More
Aluminum wire

1

485

485

... More
Copper wire/strip

1

775

775

... More
Unwinding the LT coils and dismantling the core to thoroughly check the wiring and then rewinding the same as per the actual design.

1

230

230

... More
Applying superior quality insulating varnish.

-

-

-

1

3000

3000

... More
250KVA-400 KVA

1

1500

1500

... More
25KVA-100 KVA

1

1000

1000

... More
Heat treatment of the core & coil assembly in the oven for sufficient time to completely remove the moisture.

-

-

-

1

10500

10500

... More
250KVA-400 KVA

1

5000

5000

... More
25KVA-100 KVA

1

2000

2000

... More
Reassembling of the core, the Bakelite , lamination paper, leathered paper, cork sheet gaskets to the bush rods as well as lid of the transformer etc. required during reassembling to be provided & fitted by the contracting agency.

-

-

-

1

4500

4500

... More
250KVA-400 KVA

1

2500

2500

... More
25KVA-100 KVA

1

1750

1750

... More
Providing & fitting of new heavy duty porcelain bushing insulator along with cork sheet washer on HT side of a distribution transformer after dismantling the old damaged one.

-

-

-

1

1450

1450

... More
250KVA-400 KVA

1

950

950

... More
25KVA-100 KVA

1

780

780

... More
Providing & fitting of new heavy duty porcelain bushing insulator along with cork sheet washer on LT side of a distribution transformer after dismantling the old damaged one.

-

-

-

1

750

750

... More
250KVA-400 KVA

1

250

250

... More
63KVA-100 KVA

1

200

200

... More
Providing & fitting of new HT brass bush rod, brass nuts, washers etc. after dismantling the old damaged bush rod.

-

-

-

1

950

950

... More
250KVA-400 KVA

1

550

550

... More
25KVA-100 KVA

1

200

200

... More
Providing & fitting of new LT brass bush rod, brass nuts, washers etc. after dismantling the old damaged bush rod.

-

-

-

1

6800

6800

... More
250KVA-400 KVA

1

1670

1670

... More
25KVA-100 KVA

1

520

520

... More
Shifting of HT/LT transformer back to the site in a private vehicle. Unloading the HT/LT transformer on the platform through crane/suitable means. Installing Distribution Transformer back and reconnecting the HT/LT connections (using chain pulley blocks, pullers and other tools & tackles.) and then charging it for suitable time & then testing it on the load

-

-

-

1

17500

17500

... More
250KVA-400KVA

1

8500

8500

... More
25KVA-100KVA

1

4500

4500

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Link-set to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one.(Set of 3 no’s)

1

6200

6200

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Gang-operated switch (link set) with fittings and accessories complete in all respects to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one. (Set of 3 no’s)

1

12500

12500

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Drop-out set to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one.

1

3800

3800

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Station type Lightening Arrestor set to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one.

-

-

-

... More
Polymer

1

4500

4500

... More
Porcelain

1

7600

7600

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Drop-out set member (one phase) to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one

1

1400

1400

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Station type Lightening Arrestor set member (one phase) to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one.

-

-

-

... More
Polymer

1

1350

1350

... More
Porcelain

1

2650

2650

... More
Providing /fitting of top cover gasket and gaskets of oil gauge, breather cap, oil cap etc

-

-

-

1

1350

1350

... More
400-630KVA

1

925

925

... More
100-250KVA

1

740

740

... More
63-125 KVA

1

510

510

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Pin Insulator including pin to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one.

-

-

-

... More
Polymer

1

390

390

... More
Porcelain

1

280

280

... More
Providing & fitting of new heavy duty, 11/6.6 kV, Disc Insulator to be fitted to the HT network of the electric sub-station, after dismantling the old damaged one.

1

350

350

... More
Providing & fitting of new heavy-duty, heat shrinkable kit to the HT cable after removing the old damaged one (Set of 3 pieces)

-

-

-

... More
35 mm²-70 mm²,

1

2100

2100

... More
95 mm²,

1

2800

2800

... More
150 mm²,

1

3350

3350

... More
185 mm²,

1

3650

3650

... More
Providing, laying & fitting of 0.5 ACSR DOG conductors to the HT network of the electric sub-station.

1

68

68

... More
Providing & fitting of new heavy duty, Al, LT clamps to each phase to be fitted to the LT side of the transformer of the electric sub-station, after dismantling the old damaged one

1

1250

1250

... More
Providing and fitting of M.S Channel/x-arm/angle/Collars, duly fabricated as per site requirement.

1

145

145

... More
Providing and erection of M.S tubular pole along with cement bottoming after excavation of suitable size trench and providing and fitting of G.I wire earthing.

-

-

-

... More
9m pole height.

1

18500

18500

... More
11m pole height.

1

21500

21500

... More
Providing, laying, fitting & testing of XLPE insulated XLPE Aluminum LT cable (ABC type ) of 11 KV grade

-

-

-

... More
35 mm2 AB LT Cable (3x50 +1x35) XLPE (1.1 KV ,3+1C, Al)

1

420

420

... More
50 mm2 AB LT Cable (3x50 +1x35) XLPE (1.1 KV ,3+1C, Al)

1

680

680

... More
70 mm2 AB LT Cable (3x70 +1x35) XLPE (1.1 KV ,3+1C, Al)

1

890

890

... More
Providing of the services of qualified HT/LT(instrumentation)electrician/AC technician for undertaking repairs and replacements of LT panels, starters, HT transformers ,Air conditioners and other electrical jobs within pump stations, STP, (as and when required during contract period).

1

1850

1850

... More
Providing and fitting of Double battery 2KVA/24V 200 AH inverter Combo for the divisional office Dalgate. The old batteries are to be retained by the contractor. The preferable make for the batteries is EXIDE /Luminous/Microtek

1

58500

58500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.