Housing And Urban Development Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Housing And Urban Development Department - HAUDD Tender
Software and IT Solutions
Eprocure
Opening Date5 Feb 2025
Closing Soon14 Feb 2025
Tender Amount₹ 27,66,000
Costs
EMD
₹ 55,320Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Supply Installation Of Ill11 Service And Lan Structuring Networking Set Up At Jda Building At Rail Head Complex Jammu Jk
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_HAUDD_271826_1Tender No
JDA-I/2024-25/e-NIT/82 Dated 05.02.2025Tender Authority
Housing And Urban Development Department ViewPurchaser Address
-Website
http://http://jkhudd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation
displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications including modular/MS Boxes along with necessory connections as required. All as pre approved by Executive Engineer in charge.
170
-
-
... More
Supply Installation Testing & Commissioning of following sizes Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling, power Distribution Panel and proper locking arrangements.
-
-
-
... More
12 U Rack
7
-
-
... More
42 U Rack
1
-
-
... More
Supply, installation, testing and commissioning of Patch Panel Cat 6 UTP Keystone type- 24 port - fully loaded with all accessories as required in complete respect as technical specification mentioned in compliance. Approved Make:- Panduit, Systimax, Dlink, Huber Shuner, Commscope
8
-
-
... More
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make).
-
-
-
... More
25 mm
6200
-
-
... More
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP). All as per pre approved by Engineer in charge. Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord
-
-
-
... More
1 Mtr
170
-
-
... More
3 Mtr
150
-
-
... More
6 Mtr
20
-
-
... More
Supply Installation testing and commissioning of 5 KVA/ 4 KW True Online , DSP Controlled online UPS with 1 phase AC input 50Hz and 1 phase AC output with 60 minutes backup on 12V SMF batteries Bank with Rack along with inter connecting battery cables and cable from UPS to Battery bank. The UPS should be with IGBT Based Rectifier and Inverter and with LCD/LED display for monitoring of its status along with inbuilt Galvonic Isolation Transformer. UPS should have following Features: UPS power factor : Input PF should be 0.99 AND output PF not less than 0.9 , Efficiency: up to 97% without Isolation ,Communication interface :RS232/USB port and optional SNMP compatibility for remote Monitoring, Audible Alarm : Mains Failure/Low battery / UPS Warning / Overload / Fault & By-pass Mode, THDI: not more than 5%, Noise Level less than 70db, CERTIFICATIONS & Standard : ISO-9001-14001 Certified ,Compatibility with DG Genset , Built in Automatic & Maintenance Bypass Switch,Warranty : 2 Years on UPS as well as on Batteries, Battery Make : Exide /Amaron/Quanta
Make Preferred/Approved Brand : APC-Schneider /Emerson –Vertiv /Legrand-Numeric. OEM should have own service center in the district (Need to furnish the service centre address & contact details of at least 2 engineers for better services.
1
-
-
... More
Supply Installation Testing and Commisioning of 3 X 2.5 sq.mm FRLSType Power Cable along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
300
-
-
... More
Supplying of extension Card
-
-
-
... More
5 Amp.
5
-
-
... More
Providing & FIXING WIFI Dual Band/AP
6
-
-
... More
Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 μm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 μm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements. All as pre approved by Executive Engineer in charge.
-
-
-
... More
Single Mode Patch Cord 1 Mtr.
7
-
-
... More
Single Mode Patch Cord 3 Mtr.
3
-
-
... More
Electrical Works / Point Installation with all accessories (as per requirement at site)
10
-
-
... More
Connectivity type ILL 10Mbps1:1 with Media OFC /ARC & OTC complete Job.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%