Housing And Urban Development Department Tender
... More
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Housing And Urban Development Department - HAUDD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date28 Nov 2024
Closing Date6 Dec 2024
Tender Amount₹ 16,86,000
Costs
EMD
₹ 33,720Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HAUDD_266160_1Bid Award Id
ViewTender No
E-NIT No. 07 of 2024-25 Dated 21-11-2024Tender Authority
Housing And Urban Development Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
-
-
-
... More
2 X 1.5 sq. mm (Inverter)
480
70
33600
... More
2 X 1.5 sq. mm + 1 X 2.5 sq. mm earth wire
320
233
74560
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
780
275
214500
... More
4 X 16.0 sq. mm + 2 X 6.0 sq. mm earth wire
130
1365
177450
... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
80
537
42960
... More
Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and
fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular
switch, connections etc. as required.
26
477
12402
... More
Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required
32
369
11808
... More
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
120
40
4800
... More
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
32
586
18752
... More
Supplying & fixing suitable size GI box wih modular plate and
cover in front on surface or in recess including providing and
fixing 25 A modular socket outlet and 25 A modular SP MCB, "C"
curve including connections, painting etc. as required.
5
727
3635
... More
Supplying and fixing following way, horizontal type three pole
and neutral, sheet steel, MCB distribution board, 415 V, on
surface/ recess, complete with tinned copper bus bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
-
-
-
... More
4 way (4 + 12), Double door
2
4091
8182
... More
6 way (4 + 18), Double door
4
4974
19896
... More
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single Pole
130
256
33280
... More
Double pole
26
599
15574
... More
Triple pole and neutral
6
1228
7368
... More
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required
30
32
960
... More
Chemical Earthing Supply, installation, testing and commissioning of 75 mm GI Pipe Filled with Crystalline conductive Mixture with Copper Strip of Size 40 mm x 6 mm of Length 2 mtr with Ecofriendly Backfill Compound 50 Kg. Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value & Earth pit chamber (300mm x 300mm) with CI cover for the above as required complete Job. Makes:-
Genus/Ashlok/G-MAXX/JMV/Fastrack or equivalent make
4
6216
24864
... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre
below ground as strip earth electrode, including connection/
terminating with G.I. nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
12
144
1728
... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.
pipe from earth electrode including connection with G.I. nut,
bolt, spring, washer excavation and re-filling etc. as required.
40
706
28240
... More
Supply installation testing and commissioning of IP:20 Aluminium Batten 20W-22 W +- 1 W LED Surface Mounted 4 ft. with system lumen efficacy of 100 lm/W and P.F 0.9 THD 20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab.
54
600
32400
... More
Supply installation testing and commissioning of IP20 led downlighter 15 W-18 W +/- 1 W LED Surface downlighter round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.0.95 ,THD10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab .
38
1323
50274
... More
Supply installation testing and commissioning of BLDC Ceiling Fan 1200 mm 230V 28 W with Speed RPM 350 with miimum Air delivery 220 CMM including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.
32
2730
87360
... More
Supply,Installation,Testing and Commissioning 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of ABS Plastic Material with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required .
-
-
-
... More
150 mm
6
1541
9250.14
... More
Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42)(Main L.T Panel) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved.The Panel Should be Powder Coated and should undergo the 9 Tank Process.(Refer SLD)
36
1200
43200
... More
INCOMER
-
-
-
... More
MCCB 125 A F.P 36 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100%
2
8209
16418
... More
Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(150 Amps) and MCB Strip of suitable size as Required.
2
7500
15000
... More
OUTGOINGS
-
-
-
... More
Manual Changeover 125 A F.P 415 V AC-23 Duty.
1
5642
5642
... More
MCB 63 A F.P 10 Ka "C" Curve
4
2029
8116
... More
MCB 40 A F.P 10 Ka "C" Curve
4
1433
5732
... More
MCB 32/20/16 A D.P 10 Ka "C" Curve
6
599
3594
... More
Size of wiring for CTS:- 2.5 sqmm
-
-
-
... More
Size of wiring for voltage sensing Metering :-4.0 Sq.mm
-
-
-
... More
Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm
-
-
-
... More
Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH
-
-
-
... More
Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire .
-
-
-
... More
The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.
-
-
-
... More
Gland Plates to be 3.0 mm Thick.
-
-
-
... More
Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required .
-
-
-
... More
120 mm dia (OD-120 mm & ID-103 mm nominal)
90
368
33120
... More
Supplying and Laying of 1 No. PVC/XLPE insulated and PVC Sheathed /XLPE Power Cable of 1.1 KV Grade of Following Sizes in the existing RCC/Hume/DWC/Stone ware/Metal Pipe as Required.
-
-
-
... More
3.5 C X 95Sq.mm Aluminium Armoured
120
738
88560
... More
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)
-
-
-
... More
3.5 C X 95Sq.mm Aluminium Armoured
4
875
3500
... More
Supplying,Testing and Commissioning of 24 V 2.5 KVA Sine Wave Inverter with 2 Nos of Tall tubular inverter battery 160 Ah.
2
55668
111337.6