Horticulture Production Department Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Horticulture Production Department - HPD Tender
Eprocure
Opening Date10 Dec 2021
Closing Date7 Feb 2022
Tender Amount₹ 7,03,29,896 This is an estimated amount, exact amount may vary.
Costs
EMD
Refer DocumentsDocument Cost
₹ 5,000Tender Fee
Refer Documents
Summary
Establishment Of 40 Mt Integrated Pack House At Doabgah Sopore Jammu And Kashmir
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HPD_152636_1Bid Award Id
ViewTender No
84 of 2021Tender Authority
Horticulture Production Department ViewPurchaser Address
-Website
http://jktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Ordinary Rock (@ 40% of total excavation)
165
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
160
-
-
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level :
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
215
-
-
Reinforcement for R.C.C. work including straightening. cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
37000
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for:
-
-
-
Foundations, footings, bases for columns
34
-
-
Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc.
40
-
-
Formwork : Centering and shuttering including strutting, propping etc. and removal of formwork for:
-
-
-
Foundations, footings, bases of columns etc. for mass concrete.
200
-
-
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
505
-
-
Columns, pillars, piers, abutments, posts and struts.
125
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
95
-
-
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
970
-
-
Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
87000
-
-
Providing and Fixing of Roof Insulated Sandwich Panel 40mm thick along with all accessories and necessary screws.
1825
-
-
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters.
-
-
-
80x0.90 mm M.S. laths with 0.90 mm thick top cover
60
-
-
Providing and fixing ball bearing for rolling shutters.
8
-
-
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2
mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's anddrainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)
-
-
-
Casement window double panels with top fixed with S.S. friction
hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm).
42
-
-
Providing and Fixing of PUF panels 50mm thick with all necessory accessories and fiitings complete job.
720
-
-
Providing and laying cement concrete tremix flooring , using truss screed beam ( 7 mtr to 10 mtr span) 150 mm thick with cement concrete mix M-25 Grade (RMC without flyash and slump of concrete should be 120 mm at site) and sprinkled with floor hardener of reputed brand 410@ 3.0 kg per sqm over vaccum dried concrete, including laying of steel as per design with 20 mm steel TMT shear dowel and PVC pipe sleeve cover @600 mm c/c running in all direction in construction joint and doage of A.R. glass fibre (Glassman) @1.00 kg/cum, complete the job in all respects. The LDPE Sheet of 250 micron thick of approved quality shall be used at the base of trimix flooring. Process shall consist of laying out panels, placing side form channels to true and proper level on cement mortar bed, poker vibrating the concrete followed by atleast two passes of screed vibrator, followed by one pass of levelling beam , all using 2 to 3mm flat on sides to allow for shrinkage on dewatering the consolidated slab, floating the vaccumed slab with one pass of skim floater, finishing with atleast two passes of trowel using skim floater to give desired finish. Reinforcement steel shall be paid separately. The applicator for tremix flooring shall be as per make list complete in all respect as per direction of Engineer in charge.
205
-
-
Providing and fixing transparent Polycarbonate Sheets 1mm thick .The sheets shall be clear or pigmented, textured or smooth as specified.
120
-
-
Providing and fixing aluminum work for doors, windows, ventilators and
partitions with extruded built up standard tubular sections/appropriate Z
sections and other sections of approved make conforming to IS: 733 and
IS: 1285, fixed with dash fastener of required dia. and size including
necessary filling up of gaps at junctions i.e, at top, bottom and sides with
required EPDM rubber / neoprene gasket felt etc. Aluminum sections
shall be smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminum snap beading for
glazing / panelling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-Charge (glazing,
panelling and dash fasteners to be paid for separately.)
-
-
-
Powder coated aluminum (minimum thickness of powder
coated 50 microns)
485
-
-
Providing and fixing glazing in aluminum door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket etc.
complete as per the architectural drawings and the directions of engineerin-
charge. (Cost of aluminum snap beading shall be paid in basic item.)
-
-
-
With float glass panes of 5.0 mm thickness (weight not less
than 12.50 kg / sqm)
10
-
-
Providing and fixing aluminum tubular handle bar 32mm outer dia,
3.0mm thick & 600mm long with SS screw etc. complete as per
direction of Engineer-in-charge.
-
-
-
Powder coated minimum thickness 50 micron aluminum
tabular handle bar
3
-
-
Construction of Machine Room of dimension (5 m x 2.5 m) made of Brick Masonry with RCC Slab with provision for Door and Window complete Job.
1
-
-
Machinery Works
-
-
-
Apple Sorting and Packing Line of Capacity 5TPH with all Accessories and Necessary Installations as mentioned in the Technical Specification ( Machinery) of the SBD
1
-
-
Modular Precooling Chamber of Capacity 10 MT ( min Temp 00 Deg) with all Necessary Refrigration Machinery with Refrigrant, PUF Panels for the Chamber of Thickness not Less than 120mm for the Wall and Ceiling and 75mm for the Floor, Air Tight Doors, all monitering Sensors, SS Racks and Safety Equipment with Leakage Detectors , Piping ( Insulated) etc Complete.
1
-
-
Modular Chamber of Capacity 100 MT ( min Temp 00 Deg) with all Necessary Refrigration Machinerywith Refrigrant, Ante Room PUF Panels for the Chamber of Thickness not Less than 120mm for the Wall and Ceiling and 75mm for the Floor, Air Tight Doors, all monitering Sensors, SS Racks and Safety Equipment with Leakage Detectors Piping ( Insulated), etc Complete.
1
-
-
Electrical Panel with Automatic power factor controller Panel ( APFC Panel with adequate capacitors to maintain p.f. ≥ 0.95 ;as per detailed given in standard Bidding Document
1
-
-
Cables , Cable tray , earthing pits etc. for complete referigeration
1
-
-
Pipe supports including for AHU , Condenser , Refrigeration and piping etc.as per detailed given SBD
1
-
-
Supply , design and installation of electrical items (POLE, CIRCUIT BREAKERS, PANELS AND TRANSFORMER) as per detailed given SBD
1
-
-
HAND OPERATED PALLET MOVER
5
-
-
Installation , testing , commissioning & handing over 80 KVA DG Set 415V, 50Hz , With Canopy , Day Fuel Tank, Chimney etc complete in all respects
1
-
-
Installation , testing , commissioning & handing over Dry Type Distribution Transformer of 200KVA, 11/0.433KV,DYN11 suitable for outdoor mounting on double pole structure, with Isolator switch.
-
-
-
Air Curtains - at all Door Openings
1
-
-
50 Kg platform type weighing scale
2
-
-
Organic Waste Convertor 25Kg /batch with Civil Structure/Shed
1
-
-
Odour Control System (Eco- Sorb unit)
1
-
-
Electrical Works
-
-
-
GI Electrode Earthing with 80 mm dia and 3 meter length, The electrode should be hot-dip galvanized with 120-150 micron. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-friendly and having RoHs certification .GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI.The earting pit should be cover with FRP cover, of 300 x 300 mm.GI Electrode earthing should be as per approved list of makes.
1
-
-
Supplying and fixing 25mm x 5mm copper strip on surface or in recess for earthing connection etc. as required
1
-
-
Supplying and fixing 25mm x 5mm GI strip on surface or in recess for earthing connection etc. as required
1
-
-
LIGHTENING CONDUCTOR: Providing and fixing of Lightning conductor finial, made of 25mm dia 300mm long GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including hole etc. complete as required.
1
-
-
Riveting, sweating and soldering of copper / GI tape with another copper / GI tape base of the finial or any other metallic object as required.
1
-
-
Supply and fixing GI tap 20mmx3mm thick on parapet or surface of wall for lightening conductor as required (for vertical run)
1
-
-
Supply and fixing GI tap 20mmx3mm thick on parapet or surface of wall for lightening conductor as required (for horizontal run)
1
-
-
Supplying and laying of GI tape 32mmx6mm thick from earth electrode to directly in ground as required.
1
-
-
UNCLASSIFIED ITEMS: Providing and fixinng MV danger notice plate of 200mm x 150mm made of mild steel at least 2mm thick and vitreous enameled white on both sides and with inscription in signal red color on front side as required
1
-
-
ALUMINIUM CONDUCTOR PVC INSULATED ELECTRIC ARMOURED CABLES: Providing, laying and
fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100V grade on surface etc. of the required size
-
-
-
Armoured Cable 6sqmm (twin core)
1
-
-
Armoured Cable 70sqmm (3.5 core)
1
-
-
Cu cable Armoured Cable 35 sqmm (3.5 core)
1
-
-
PROVIDING AND INSTALLATION OF CEILING / EXHAUST FANS: Providing and installation of exhaust fan of following sizes in the existing opening, including' making the hole to suit the size of the above fan. making good the damages. connections. Testing and commisslonina etc as reauired: Exhaust fan, heavy duty 380mm sweep including suitable Louver
1
-
-
SUPPLYING AND FIXING OF WALL BRACKETS / CEILING FITTINGS: Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder(s), complete with all accessories but excluding CFL lamp including making connections. testing etc as required: Bulk Head Fitting, CFL type (Category - A)
1
-
-
Supply and erection of Poles: Supplying and erection of street light bracket made of GI pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt and nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over prming coat complete in all respects as required. 40mm dia GI pipe heavy class
1
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of up to 150 sqmm size in the existing RCC/ HUME/ METAL pipe as required. (Laying of MV Cables)
1
-
-
CABLE TRAY AND RACE WAY: Supply, laying & fixing 14 SWG single compartment GI race way of following sizes along-with necessary cable support system as directed including fixing accessories like dash fasteners cable ties and junction box etc. complete in all respects including earthing of trunking with 4sqmm. PVC insulated wires including cutting chasing of floor and making of good (cutting of floor by machine).GI Race ways shall be minimum 20mm below floor finish as required as per approved drawings, specifications of this tender and directions of Project Manager.
1
-
-
40x 300 x 500mm deep
1
-
-
50 x 225 x 800mm deep.
1
-
-
Supplying & installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, in convinient sections,joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts, painting suspenders etc as required.
1
-
-
600 mm width x 62.5 mm depth x 2.0 mm thickness
1
-
-
450 mm width x 62.5 mm depth x 2.0 mm thickness
1
-
-
DISTRIBUTION BOARD & 3 PHASE METER & SUB MAIN DISTRIBUTION BOARD (SMDB): Supplying and
fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board double door of sheet steel, dust protected, duly powder painted, inclusive of 80 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 40A / 63A TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars ( with 6 MCB’s/ MCCB) as required.
-
-
-
12 Way TPN DB Double Door (Vertical)
1
-
-
S/I/T/C sheet steel inclosure for 32-63Amp TPN MCB complete with all accessrories as required.
1
-
-
MULTIFUNCTION METER: S/I/T/C 3 Phase Multifunction Meter, L&T, 4410 LED, Class 0.5 with RS 485 along with 3 Nos. CTs of 100/5A Class-I and 3 phase indicator lamps, internal wiring with copper flexible wire, all connections, testing, commissioning and other petty material required to complete the job including labour charges or erection in existing cubical panels with cost of cutting the panel sheet and din bars etc.
1
-
-
LIGHTING FIXTURES: Supply, Carriage, erection, testing and commissioning of LED fitting. The lumen output of LED should be minimum 100 lumens per watt and should be type tested from NABL I UL accredited laboratory for LM79 & LM80 test reports and copy of same has to be submitted to the client department. The Fixture supplied with Electronic high efficiecy driver having Power factor 0.9, THD 10%. The sample of fitting shall be got tested in the presence of representative from NABL I UL accredited laboratory and the testing fee shall be borne by the contractor / supplier.
-
-
-
S/E of 40W LED Liner fitting surface mounted. made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230V, 50 HZ supply, high efficent fixtures complete in all. The job includes cost of cutting the false ceiling to fix the fitting including giving support of chain from ceiling or frame and making connection to the nearest point with copper wires.
1
-
-
S/E of 40W LED Liner fitting surface mounted. made of extruded aluminium heat sink body provided for efficient heat dissipation & integrated electronic driver suitable for single phase A.C. 230V, 50 HZ supply, high efficent fixtures IP65 complete in all. The job includes cost of cutting the false ceiling to fix the fitting including giving support of chain from ceiling or frame and making connection to the nearest point with copper wires.
1
-
-
S/E of Surface Mounted LED 40 W Fitting Panel of size 4' foot long complete with driver. The fitting is to be fixed on ceiling with anchor fasteners.
1
-
-
S/E of Self contained with 8W fluorescent tube for non maintained emergency lighting for 3 hours duration Complete as required.
1
-
-
S/E of 230/48Volts 440AH ,Battery charger with rectifier, DC Ammeter, DC Voltmeter and common DC bus for DC supply to battery.
1
-
-
12W LED round fitting recess mounted. The The job includes cost of cutting the false ceiling to fix the fitting including making connection to the nearest point with copper wires.
1
-
-
S/I/T/C of LED street light light fitting of 70W / 72W rating with minimum 110 lumens per watt. The fitting is to be fixed on existing bracket mounted on Pole. The job includes cost of fitting, wiring connection etc. required to complete the job.
1
-
-
Supply ,Fixing, testing and commissioning of internal road light poles including the cost of providing top 70mm and bottom 130mm dia 3 mm thick 200x200x12mm MS base plate welded to the base of the pipe , Arm Length 1000mm and including digging and including the cost of masonry base pedestal built with 1:3:6 concrete (1 cement, 3 coarse sand and 6 graded stone aggregate 40 mm nominal size) provided with a 200 mm x 150 mm x 100 mm deep looping cable GI box recessed in the base pedestal / surface mounted fabricated from 14 SWG GI sheets with hinged gas kitted lockable door, terminal block for incoming and outgoing PVCA cables, 10 amps SP MCB, 2 Nos. suitable length 25mm dia GI pipe for incoming and outgoing cables and including the cost of painting, wiring, in pole from terminal block up to the light fittings with 2 x 2.5 sq.mm copper conductor 1100 volt grade PVC insulated wires along with loop earthling with 1 no. 8 SWG GI wire, earth stud etc. complete as required and as below. IS2713-PART II. 6
mtr Long Swaged Pole. Planting depth shall be 600 mm. Height above ground shall be 5.4 metres including MCB & M.S. box etc. as required.
1
-
-
S/I/T/C of LED street light light fitting of 25W rating with minimum 110 lumens per watt. The fitting is to be fixed on existing bracket mounted on wall. The job includes cost of fitting, wiring connection etc. required to complete the job. Wall mounted fixture
1
-
-
Supply, installation, testing and commissioning of Addressable type fault isolator for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base model).
1
-
-
Supply and laying of 2 Core, 1.5 Sq. mm twisted pair copper conductor cable, low smoke zero halogen, high performance silicon rubber insulated, overall shielded, sheathed fire survival (HPSR) armored cable on surface/ recess/ existing couduit/ existing cable tray complete in all respect as per BS 6387 CWZ, EN50200, LPCB approved for the same size.
1
-
-
Supplying, installing, testing and commissioning of Analog Addressable air duct smoke detector with an efficient housing design and sampling tubes mounting based LED, Address Switch to programme the detectors, complete as required. (FOR AHU's).(It shall be UL/FM Listed)..
1
-
-
CCTV SYSTEM
-
-
-
Supply Installation testing commissioing of 540 TVL Day/Night Dome cameras with sensitivity of minimum
1.6 lux (Color) and 0.01 lux(B&W). The cameras shall use the1/3-inch interline transfer CCD sensor and shall have a 2.8 to 12mm varifocal lens. The Cameras shall be EN/UL Listed asper the specifications -(in P & G area , Lift Lobby and admin office)
1
-
-
Supply Installation testing commissioing of 540 TVL CCD Camera with minimum lux level of 0.01 lux. The cameras shall use 2.9 to 8mm varifocal lens. Electronic Shutter range of 1/50 - 1 / 100,000 sec. The Cameras shall be EN/UL Listed asper the specification-( pasage)
1
-
-
Supply Installation testing commissioing of 540 TVL CCD True Day/Night Camera with minimum lux level of
0.001 lux. The cameras shall use 2.7-13.5 mm varifocal lens. Electronic Shutter range of 1/50 - 1 / 100,000 sec. The Cameras shall be EN/UL Listed asper the specification.(External Perhaperi)
1
-
-
Outdoor Aluminium housing Small, Sleek, Contemporary Design High Reliability Die-Cast Construction Tamper-Proof Hardware, with Heater/Blower, Sun Shroud, Meets IP66 and NEMA Standards. UL,CE, FCC certified with Inbuilt power adapter for cameras asper the specification.
1
-
-
Supply, installation, testing & commissioning of UL listed DVR 16ch with 6Slots for HDD and DVD writer,Compression H.264,Outputs CVBS (BNC),HDMI, VGA ,4 audio input,Control RS 485 and RS 232,16 Alarm Input ,Video Output Loop Through,ESata connector for backup device,One front and one rear USB connector for mouse or USB memory device,Support Joystick Mode Manual, motion detection, scheduled,alarm,Alarm handling Motion detection Supports NAS
1
-
-
Supply, installation, testing and commissioning RG11 Cable in existing Conduit/raceway/cable tray with clamp/sadles/tie as per technical specification etc complete ar required .
1
-
-
Supplying and fixing of 25 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1
-
-
SITC of 42" LED 1920 x 1080 HD Display System
1
-
-
UN- INTERRUPTED POWER SUPPLY
-
-
-
Supply, installation of 1 KVA UPS with 15 Minutes battery Backup at load using Sealed Lead Acid Maintenance Free batteries. Battery design life is 5-6 yrs.including with MS Racks for housing batteries, Battery Disconnector, battery to battery inter-links, Battery to UPS cable for a distance of 10 meters per UPS complet as required.
1
-
-
TPN ISOLATOR FOR GOODS LIFT
-
-
-
Supply, installation, testing and commissioning of Recessed 63A ,4Pole TPN isolator in powder coated, 1.6mm thick MS enclosure having facility for incoming and outgoing cables, set of ON/OFF/Trip indicating lamps shall be protected by control MCBs, complete with all materials and as per site requirement.
2
-
-
Any other item required for the Complete Execution of the Project including for the Trial Run of the Plant but not coveered (Please Specify). Tenderer to use extra Sheet for all the Items required for the Plant. Extra Sheet needs to be on the Agency's Letter Head.
1
-
-
Evaluation Notes How It Works ?