Floriculture Department Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Floriculture Department - DOFK Tender

Eprocure
Opening Date1 Jul 2020
Closing Date10 Jul 2020
Tender Amount₹ 39,21,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.

1300

-

168

... More
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.

-

-

-

... More
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM EARTH WIRE

450

-

137

... More
4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM EARTH WIRE

100

-

733

... More
2X 4 sq. mm + 1 X 4 sq. mm earth wire

100

-

168

... More
Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections but exculding modular plate etc. as required

-

-

-

... More
5/6 amps switch

26

-

164

... More
3 Pin 5/6 amp socket outlet

26

-

358

... More
Supplying and fixing modular blanking plate on the existing modular plate and switch box exculuding modular plate as required

100

-

24

... More
Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as Required.

25

-

288

... More
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.

33

-

406

... More
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 25 amps modular Multi pin socket outlet with connection,painting etc. as required.

17

-

769

... More
Supplying and fixing following way,Prewired TP&N PPI Distribution Board of Sheet Steel for 415 Volts on surface/Recess complete with Ready to use DBs - Provided with 100A insulated phase bus-bars,neutral bar/s with shroud/s, earth bar/s , sticking saddles , cement spill protector ,color-coded interconnecting wire set , cable ties , blanking plates and circuit identification labels.The D.B should be IK-09 Compliant.(The Cost of D.B is without MCB's)(IP Rating-43)(SCHNEIDER/LEGRAND/L&T)

-

-

-

... More
6 Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(6+6+6) SP MCB's O/G's)

3

-

5390

... More
8 Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(8+8+8 )SP MCB's O/G's)

3

-

7650

... More
Supplying,Installation ,Testing and Commissioning of Four Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required.

-

-

-

... More
63 Amps

6

-

670

... More
Supplying and Fixing Following rating,Double Pole (Single Phase and Neutral),240 Volts Residual Current Circuit Breaker (RCCB) having a sensitivity of current upto 300 ma in the existing MCB DB Complete with connections ,testing and commissioning as required.

-

-

-

... More
40 Amps

18

-

2975

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way, Double door

3

-

1151

... More
Supplying,Installation ,Testing and Commissioning of D.P Pole 220V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required

-

-

-

... More
25 Amps

3

-

1125

... More
Supplying,Installation ,Testing and Commissioning of 1P+N(2 Module) Surge Protection Device(SPD) Type 2,I max 15 KA .

3

-

9000

... More
Supplying and fixing 5 amps to 32 amps. Rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commsissioning etc. as required.

-

-

-

... More
Single Pole

117

-

173

... More
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required(SCHNEIDER/LEGRAND/L&T)

15

-

24

... More
Supplying,Installation ,Testing and Commissioning of 3P+N(2 Module) Surge Protection Device(SPD) Type 2,I max 15 KA

6

-

11800

... More
Supplying and Laying of B-Class 100 mm Dia Size G.I Pipe under the Road/Floor not less than 1 mtr below the Ground Level including cutting the Road/Floor and making Good the same as required.

10

-

750

... More
Supplying,Installation and Testing of 50 mm Cu. Pipe Filled with Crystalline conductive Mixture with Copper Strip of Size 25 mm x 5 mm of Length 2 mtr with Ecofriendly Backfill Compound 50 Kg.(2 Nos for Panel and 2 Nos for UPS for Fire Alarm Syatem) Earth pit chamber (300mm x 300mm) with CI cover for the above.

4

-

15000

... More
Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.

50

-

1082

... More
SITC of Ceiling Fan,Capacitor type suitable for low voltage operation including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required.

-

-

-

... More
1200 MM SWEEP

25

-

2388

... More
SITC of pre-wired Surface Mounted LED Ceiling Down Lighter Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required .

53

-

1100

... More
SITC of pre-wired Surface Mounted LED 2 x 2 Panel Ceiling Light including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.

84

-

2800

... More
Supply of AC 230/250 Volts, 50 Hz exhaust fan with louveres of Following Sizes including connection etc. complete as required .

-

-

-

... More
300 mm

18

-

2261

... More
Providng and Fixing carbon dioxide (CO2) Type fire Extinguishers of 4.5 Kg Capacity Conforming to IS: 2878-1976 and cylinders fully charged as required.

4

-

5686

... More
Provding of set of 4 Nos 9.5 Ltrs Capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint"FIRE" and mounted on MS angle iron frame with capacity including filling of sand etc.

1

-

2111

... More
Supplying of First Aid Box as approved by St. John Ambulance Brigade/Indian Red Cross Conforming to IS:2217-1963

1

-

2170

... More
Providing of rubber Mat 1 mtr wide and 12 mm thick to withstand 15 KV dielectric strength as per IS: 5424-1969

5

-

2581

... More
Supplying,Installation, Testing and Commissioning of Cubical Type LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars,Interlocking ,A.M.F Logic etc. as required as per the Following Description.(IP:42)

-

-

-

... More
INCOMER a) Microprocessor Based MCCB 160 Amps 4 P with Breaking Capacity 36KA (Icu=Ics=100%)(2 Nos). b) Power Contactor 4 P 250 Amps(1 Nos)AC-3 With Electronic Coil Suitable for 24 V A.C/D.C Supply(3 Nos). c) Indicating Lamps RYB (2 Set). d) Voltmeter-0-500 Volts(2 Nos). e) Ammeter(0-250 A)(2 Nos). f) Selector Switch (4 Nos). g) SMPS 24 V D.C of Suitable VA Burden for Supply to Contactor Coil (1 Nos). h) Current Transformer 200/5 A 10 VA Burden, Class-1(2 sets). i) Aluminium Busbar 300 Amps FP E-91 E Grade Electrolytic Aluminium. j) Digital Load Manager(2 Nos). k) TPN MCB 6 A(6 Nos). OUTGOINGS. a) Microprocessor Based MCCB 63 Amps FP Icu=Ics=100% with Breaking Capacity 36 KA (09 Nos). b) Microprocessor Based MCCB 32 Amps FP Icu=Ics=100% with Breaking Capacity 36 KA (05 Nos). c) Indicating Lamps ON OFF TRIP( 14 Nos). d) Load Bearing Members to be made out of 2.0 mm CRCA Sheet. e) Partitions to be made out of 1.6 mm CRCA Sheet. f) Gland Plates to be 3.0 mm Thick.

1

-

335000

... More
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of Automatic control panels with Normal Duty capacitors, fabricated out of 14 gauge CRCA sheet steel in cubicle compartmentised, free standing, floor mounted, dust and vermin proof with reinforcement of suitable size, angle iron, channel, `T’ sections and / or flats wherever necessary. Cable gland plates shall be provided on top the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 No. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels.

-

-

-

... More
INCOMER a) Microprocessor Based MCCB 100 Amps 4 P with Breaking Capacity 36 KA(Icu=Ics=100%)(1 Nos). b) Indicating Lamps RYB (1Set). c) Voltmeter-0-500 Volts(1 Nos). d) Ammeter(0-100 A)(1 Nos). e) Selector Switch (2 Nos). f) Auto Manual Switch(1 Nos). g) Current Transformer 60/5 A 10 VA Burden, Class-1(1 Sets). h) Aluminium Busbar 100 Amps FP E-91 E Grade Electrolytic Aluminium. i) TPN MCB 6 A(3 Nos). OUTGOINGS a) Microprocessor Based MCCB 20 Amps 3 P with Breaking Capacity 36 KA(Icu=Ics=100%)(2 Nos). b) Microprocessor Based MCCB 50 Amps 3 P with Breaking Capacity 36 KA(Icu=Ics=100%)(1 Nos). c) Capacitor Duty Contactor 5 A (2 Nos). d) Capacitor Duty Contactor 20 A (1 Nos). e) Capacitor 5 KVAR S.D 440 V (2 Nos). f) Capacitor 10 KVAR S.D 440 V (2 Nos). g) Indicating Lamps ON OFF TRIP( 03 Nos). h) APFCR 5 Stages. i) Load Bearing Members to be made out of 2.0 mm CRCA Sheet. j) Partitions to be made out of 1.6 mm CRCA Sheet. k) Gland Plates to be 3.0 mm Thick.

1

-

90000

... More
Supplying, Installation, Testing and Commissioning of UPS Cubical Type LT Panel Board Suitable for 240 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers, Out Goings, Bus Bars, Interlocking , etc. as required as per the Following Description.(IP:42)

-

-

-

... More
INCOMER a) MCB 63 Amps 2 P with Breaking Capacity 10KA (1 Nos) b) Voltmeter-0-250 Volts(1 Nos) c) Ammeter(0-60 A)(1 Nos) d) Selector Switch (2 Nos) e) Current Transformer 60/5 A 10 VA Burden, Class-1(2 sets) f) Aluminium Busbar100 Amps FP E-91 E Grade Electrolytic Aluminium g) TPN MCB 6 A(2 Nos) OUTGOINGS a) MCB 16 Amps 2 P with Breaking Capacity 10KA (5 Nos) b) Load Bearing Members to be made out of 2.0 mm CRCA Sheet. c) Partitions to be made out of 1.6 mm CRCA Sheet d) Gland Plates to be 3.0 mm Thick.

1

-

45000

... More
Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required .

-

-

-

... More
160mm/136mm

50

-

250

... More
Supplying and Laying of 1 No. PVC/XLPE insulated and PVC Sheathed /XLPE Power Cable of 1.1 KV Grade of Following Sizes in the existing RCC/Hume/DWC/Stone ware/Metal Pipe as Required.

-

-

-

... More
3.5 C X 150 Sq.mm A2XFY

50

-

980

... More
3.5 C X 95 Sq.mm A2XFY

50

-

765

... More
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)

-

-

-

... More
3.5 C X 150 Sq.mm A2XFY

4

-

2750

... More
3.5 C X 95 Sq.mm A2XFY

4

-

1775

... More
Supply, transportation,Unloading , installation, testing & Commissioning of the following rating of UPS System(IGBT Based) including unloading,transportation from store to site ,errection instlattion,testing of UPS System including Battery and Battery rack errection & Installation under the supervision of supplier of UPS. Note:- Contractor has to submit the drawings & battery selection detail before procurement. Specification of UPS system shall be provided with Static by pass and Maintenance by pass facility with distribution board . 5 KVA UPS , Input 3 Phase 4 wire and output 1 phase 3 wire with 15 min. Back up

1

-

125000

... More
Providing of following size of DLP plastic U‐PVC trunking of following items including accessories as required.

-

-

-

... More
Plastic trunking without cover 105 mm X 50 mm(Cat No. Legrand 010422)

50

-

688

... More
Flexible cover 85mm width (Cat No. Legrand 010520)

50

-

272

... More
Separation suitable for trunking size 105mmx50mm.(Cat No. Legrand 010582)

50

-

182

... More
Body joint for aligning bases during installation suitable for trunking size 105mmx50mm(Cat No. Legrand 010691)

50

-

62

... More
Cover joint for 85 mm width suitable for trunking size 105mmx50mm)(Cat No. Legrand 010800)

50

-

126

... More
Flat Angle ‐ 90Deg flat angle (suitable for truncking size 105mm x 50 mm) (Cat No. Legrand 010785)

105

-

544

... More
External Angle 80 Deg to 100 Deg Suitable for Trunking size (Cat No. Legrand 010622)

106

-

382

... More
Internal Angle 80 Deg to 100 Deg Suitable for Trunking size (Cat No. Legrand 010602)

107

-

380

... More
End caps (suitable for trunking size 105mmx50mm)(Cat No. Legrand 010702)

20

-

140

... More
Clips for holding cables in Place(Cat No. Legrand 010882)

100

-

52

... More
Supplying following Modular base , cover plate & insulation unit DLP trunking (for 85 mm cover) etc. as required.

-

-

-

... More
Modular Base (Cat No. Legrand 010927)Suitable for Trunking Size 105mm x 50mm)

132

-

238

... More
Frame 2 M (Cat No. Legrand 010922)Suitable for Trunking Size 105mm x 50mm)

48

-

136

... More
Frame 6 M (Cat No. Legrand 010962)Suitable for Trunking Size 105mm x 50mm)

42

-

266

... More
Supplying and Fixing following Switches/ Sockets etc. as required. for DLP Trunking

-

-

-

... More
6 A Socket(Cat No. Legrand 573473)

60

-

358

... More
6 A Switch(Cat No. Legrand 573400)

60

-

164

... More
RJ 45 Socket(Cat No. Legrand 573428)

30

-

708

... More
RJ 11 Socket (Cat No. Legrand 573426)

6

-

196

... More
Fire Detection:- Microprocessor based 1 loop capacity , Networkable analogue addressable type fire alarm control panel with 640 character LCD display, The panel should be equipped with sufficient numbers of loop with 15% spare capacity with each loop shall have a capacity of 90 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. The Panel shall have BACNET CARD for integration. (UL 9th Edition Approved).

1

-

135000

... More
Multi Cooperative Sensing Type Analog addressable Photoelectric smoke detector with mounting based LED.

42

-

4932

... More
Supply,Installation,Testing and Commissioning of Heat Sensing Type Analog addressable Heat detector with mounting based LED.

3

-

4700

... More
Addressable type fault for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model).

3

-

3917

... More
Addressable control modules for Hooters / Sounders / Strobes etc.

5

-

2727

... More
Addressable monitor modules for Sprinkler Flow Switch and Door Holders.

3

-

4865

... More
Addressable Manual Pull Station.

5

-

5232

... More
Supply and drawing of 2 C X 1.5 Sq mm Un armoured cable

450

-

45

... More
Directional Sounders with 20 hz to 20 khz operating frequency with minimum 8 distinct sound patterns to indicate corridors, Exit doors, Move upward, move down ward etc. to direct Occupants for fast & safe Evacuation as specified in NFPA 72 - 2007 edition.

5

-

5605

... More
Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/ Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25mm PVC Conduit

400

-

65

... More
SITC of ABC Type Fire Extinguisher

8

-

9800

... More
Fire Fighting Hydrant system:- Supply, installation, testing & commissioning of single headed, gunmetal ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63 mm dia instantaneous type female outlet complete with plastic cap and GI chain, twist release type plug and all accessories as per IS:5290-1983 (Type 'A').

3

-

8200

... More
Supply, installation, testing & commissioning of First-Aid fire hose reels wall mounting swinging type, fitted with of heavy duty mild steel construction with CI brackets, 25 mm dia. ball valve and 20 mm dia. x 36m long high pressure Hose Reel tubing as per IS:444 with Stainless Steel shut-off nozzle having 5 mm dia. orifice. The hose reel shall strictly confirm to IS:884-1985.

3

-

8200

... More
Providing and fixing 63mm dia 15m long rubberized fabric lined hose including gunmetal male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects, hose shall conform to IS:636 type II and coupling to IS:903-1975 (ISI marked)

6

-

6500

... More
Providing and placing in proper position gunmetal 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS:903).

3

-

2290

... More
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.

3

-

1570

... More
Providing and fixing 4 way gunmetal fire brigade inlet breaching head as per IS:904 specification tested for 20Kg/sq-cm with 63mm dia instantaneous type inlet and 150/100mm dia flanged outlet with built in check valve for fire brigade connection to under ground tanks and fire risers including companion flanges including nuts, bolts & washers etc.

1

-

15670

... More
Supply, installation, testing & commissioning of air cushion tank (air-vessel) 250 mm dia.x1.0 m high with dished top, made of minimum 6 mm thick MS pipe/plate complete with 25 mm dia. brass air valve (ball valve, pressure gauge type), 25 mm dia brass stop cock, nipple, tees, B46 elbow, pipe and all accessories as required including fixing brackets.

1

-

18250

... More
Providing and fixing Weather proof hose cabinets for External and Internal hydrant fabricated from 16 g MS sheet with full glass door and locking arrangement, suitable to accommodate one hydrant valve, 2 nos.15m long hose, 1 No branch pipe and one fireman's axe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 mx 0.25 m).

3

-

5250

... More
Internal Piping:- Supply, installation, testing & commissioning of mild steel pipe (IS:1239 Part-I) heavy class including cutting, threading, welding etc. bends, elbows reducers, clamps, hangers etc. including cutting holes in brick or RCC walls/slabs and making good the same complete including the cost of structural work for supports fabricated from standard sections of required sizes and thickness e.g. MS rods, angles channels, slotted angle, etc., cutting to sizes, drilling welding fixing to insert plates, including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including all steel work. Note : Pipes upto and 50 mm dia shall be threaded joints, above 50mm shall be welded joints.

-

-

-

... More
150mm dia

20

-

1920

... More
80mm dia

10

-

1550

... More
FIRE PUMPS, VALVES & ACCESSORIES TERRACE PUMP:- Supply, testing, installation, testing & commitioning of electric driven fire (Terrace) pump of capacity 450 LPM 35 mtr. Head with 7.5 H.P. TEFC motor at 2900 r.p.m. complete with coupling, coupling guard, base plate, anti vibration pad, foundation etc.

1

-

51250

... More
Control Panel for Fire pumps at Terrace Level :-Fabricating & Supply, installing, testing and commissioning of compartmentalized common control panel for Electrical motor driven pumps.

-

-

-

... More
INCOMING a) 1 nos. of 32A TPN MCB. b) 1 Sets of 32 Amps. TPN Al. Bus bars with colour coded heat shrinkable PVC sleeves. c) 1 Set of RYB indicating lamps with individual HRC control fuses. d) 1 No. 96 x 96 mm 0-50 Amps. Ammeter with selector switch and suitable rated current transformers. e) 1 No. 0-600V 96 x 96 mm Voltmeter with selector switch. OUTGOING. a) Feeder for Booster Pump - 1 Nos. b) 1 No. 32A TP MCCB c) DOL starter with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons. d) -1 No. Auto manual selector switch All the components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffeners (if required). The panel shall be powder coated of approved colour both inside & outside. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. Also panel shall have sufficient (min. 50 Nos.) NO/NC contacts for extending the status ( annunciation) of fire pumps to the Fire alarm panel.

1

-

27000

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.(5 Tanks of 2000 Ltrs Each)

5

-

21000

... More
SITC of Non Return Valve of 150 mm dia with Fire Tank at Terrace /Attic Floor

2

-

6477

... More
SITC of Y- Strainer of 150 mm dia with Fire Tank at Terrace /Attic Floor

1

-

10530

... More
Non-Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.-150 mm Dia

1

-

5914

... More
SITC of Butterfly Valve of 150 mm dia PN 1.6

4

-

2500

... More
Providing and fixing pressure switch (for operation at 0-25 kg/cm2) with required fittings and accessories complete.

3

-

3200

... More
CCTV/INTERNET/TELEPHONE: -Providing, fixing supplying, termination & certification of networking . The item mentioned shall include the cost for laying Cat 6 UTP wire of in existing conduits for the wiring & it shall be such that each point has a dedicated single CAT 6 wire from the wall outlet to the patch panel.The rates quoted shall include the cost of termination of CAT6 cable in the wall sockets & patch panel including the cost of certification by network engineer using a penta-scanner , ferrulling of every point on both sides the contractor will have to provide the network certification in writing. Nothing extra shall be paid for on account of termination, crimping, certification etc. complete in all respects as desired by Engineer Incharge. The following items will be got exectued as under

-

-

-

... More
Supplying and Fixing following Switches/ Sockets etc. as required.

-

-

-

... More
RJ 45 Socket(Cat No. Legrand 573428)

12

-

708

... More
RJ 11 Socket (Cat No. Legrand 573426)

6

-

196

... More
Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduit,cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25mm PVC Conduit

400

-

65

... More
Supplying and Drawing of UTP4 pair CAT-6 LAN cable in the existing surface/Recessed Steel/PVC Conduit as required .

650

-

45

... More
Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/PVC conduit as required.

400

-

16

... More
Supply, installation, testing and commissioning of Junction Boxes/DB-20 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC

3

-

950

... More
Supply, Installation, Testing and Commissioning of Semi managed 24 port POE , complete as per specification and as desired by EIC.

3

-

32000

... More
Supply & Erection of lockable 9/12 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc,, complete as per specification and as desired by EIC.

3

-

12500

... More
Supply & Erection of CAT 6, 24 port Jack panel for termination of CAT6 cable,Testing & certification of the network with Omni/Penta Scanner of each Cable,

3

-

5400

... More
Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC.

60

-

289

... More
Supplying,Installation,Testing and Commissioning of 40 Inches Full H.D LED Display Monitor as per the Specifications attached.

1

-

38000

... More
Supplying of 24 Channel Network Video Recoder (NVR) as per the Specifications Enclosed with a Hard Disk Memory of 8 TB capacity.

1

-

75000

... More
Supplying,Installation,Testing and Commissioning of 2 Mega Pixel Full High Definition Weather Proof Networkable Bullet Camera.

11

-

15800



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.