Chenab Valley Power Projects Private Limited Tender
Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.
Chenab Valley Power Projects Private Limited Tender
Electrical and Electronics
Eprocure
Opening Date21 Mar 2024
Closing Date10 May 2024
Tender Amount₹ 12,19,557
Costs
EMD
₹ 25,000Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Supply, Installation, Testing And Commissioning Of Street Lights On 8 Meter St Pole Around The Premises Of Office Cum Field Hostel At Dam Site Of Pakal Dul He Project, Cvpppl, Kishtwar, Jnk
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CVPP_801775_1Bid Award Id
ViewTender No
CVPPPL/PDHEP/CnP/NIT-283 /2024/964 Date-21.03.2024Tender Authority
Chenab Valley Power Projects Private Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, Installation, Testing and Commissioning of Street Lights on 8 meter ST Pole around the Premises of Office cum Field Hostel at DAM Site of Pakal Dul HE Project, CVPPPL, Kishtwar, JnK.
Supply, Installation, Testing and Commissioning of Street Lights on 8 meter ST Pole around the Premises of Office cum Field Hostel at DAM Site of Pakal Dul HE Project, CVPPPL, Kishtwar, JnK.
Supply, Installation, Testing and Commissioning of Street Lights on 8 meter ST Pole around the Premises of Office cum Field Hostel at DAM Site of Pakal Dul HE Project, CVPPPL, Kishtwar, JnK.
BOQ Items
Painting of pole Red Oxide.
16
-
-
Painting of Pole, Aluminium Paint.
16
-
-
Supplying and fixing of looping cable box - 300mm (H) x 200mm (W) x 150mm (D) made of 1.6MM MS steel sheet with 2 nos. 25 mm x 5 mm MS Clamp complete with bolts & nuts etc. as required for fastering looping cable box - with the pole including providing drilled holes for cable entry and exit through 2 no. glands (for 3 C, 25 sq.mm cable) and hole for street light wire entry & comprising of Din channel inside for fixing 2 pole MCB and 1 x 3 Way strip suitable for in and out 25 sq.mm, core armoured aluminium cable and painting the box with aluminium paint as required (but excluding cost of glands); transportation and delivery upto Drangdhuran, Kishtwar.
16
-
-
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of underground cable as required.
16
-
-
Supply of 3 core, 25 sq.mm, XLPE armoured aluminium cable; transportation and delivery upto Drangdhuran, Kishtwar.
300
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq.mm.
200
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (6 amps).
12
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral (6 amps).
16
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 25 sq. mm (25mm).
32
-
-
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
16
-
-
Supply of 90 watt LED street light at Drangdhuran, Dam Site.
50
-
-
Supply of 1.5 sq.mm, 3 core PVC insulated copper cable at Drangdhuran, Dam Site.
300
-
-
Supply of 1.5 sq.mm, 2 core PVC insulated copper cable at Drangdhuran, Dam Site.
150
-
-
Supply and installation of Single pole MCB gang box on existing pole.
12
-
-
Installation of street light on ST swaged pole/street light bracket and connection of street light with 1.5 sq.mm 3/2 core copper cable with two/single pole MCB including drawing of cable through pole (but without cost of cable).
50
-
-
Overhead laying of armoured aluminium cable upto 25 sq.mm with 8 SWG support wire (including cost of 8 SWG support wire but excluding cost of armoured cable).
15
-
-
Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing mansonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metres long etc. With charcoal/coke salt as required.
1
-
-
Supplying and laying 25 mm x 5 mm GI strip at 0.50 metres below ground as strip earth electrode, including connection/termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50 mm.