Airports Authority Of India Tender

Search from the latest JKtenders and find a business opportunity fitting your SME on the online platform of BidAssist. If you're wondering how to find the latest JK tenders or from where to get all the documents without the hassles, this is what we explain here. Find the best opportunities coming to the surface via the JK government, PSUs and state corporations.

Airports Authority Of India - AAI Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date8 Jan 2025
Closing Date25 Jan 2025
Tender Amount₹ 5,14,01,660 
Notes
Download

Costs

Summary

Augmentation Of Power Supply System At Srinagar Airport

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DG SET'S - 500KVA (with inbuilt PCC 3.3 controller) SITC of 'Silent Type' Diesel Generating set having PCC 3.3 controller alongwith having Prime Power Rating of 500KVA, 415V at 1500RPM, 0.8 lagging power factor at 415V suitable for 50Hz, 3 Phase system & for 0.85 Load Factor and consisting of following: Diesel Engine Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500RPM suitable for above output of alternator at 44 degree C, 50%RH & at 1600 meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% oveloading for 1 hour after 12 hour of continuos operation. The engine will be fitted complete with all accessories. Engine mounted Instrument Panel fitted with and having digital display for following: i) Start stop switch with key ii) Water Temperature indication iii) Lubrication oil pressure indication iv) Lubrication oil temperature indication v) Battery charging indication vi) RPM indication vii) Overspeed indication viii) Low lubricant oil trip indication ix) Engine hours indication Alternator Synchronous alternator rated at 500KVA, 415V at 1500 RPM, 3 Phase 50Hz AC Supply with 0.8 lagging power factor at 44 degree celcious, 50% RH and at 1600 Meter MSL. The alternator shall be having SPDP Enclosure, crushless continuos duty, self excited and self regulated through AVR confirming to IS 4722/ BS 2613 suitable for tropical condition and of class F/H insulation. Base Frame and Foundation Both the Engine and alternator shall be mounted on suitable base frame made of M.S. channel with neccessoru re-inforcement which shall be installed on suitable cement-concrete foundation and vibration isolation arrangements as per recomdation of manufacturer. Fuel Tank Daily service fuel tank of 990 liters capacity fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with M.S. class 'C' pipes of suitable dia. Complete with valves, level indication and accessories as required as per specification. Exhaust Sytems Dry Exhaust main fold with hospital exhaust silencer and catalytic converter. Starting Sytems 12 volt/ 24 volts DC Starting sytem comprising of starter motors, voltage regulator and arrangement of initial excitation complete with suitable no. of batteries (25 Plates, 180A hour capacity, lead Acisd Type) as required as per specifications. Enclosure Accoustic and weatherproof enclosure with arrangement of fresh air intake for cooling of engine and alternator, extraction, discharging hot air in to the atmosphere and suitable arrangement for busduct/cable arrangments, as per specification. Exhaust Gas Chimney Supply and fixing exhaust gas piping of suitable Dia welded black M.S. 'B' Class pipe, confirming to IS:3589 cut to required length and insulated with necessory bends, support and clamps, anti vibration mounting, insulation exhaust system and normal wool/ rock wool, 50m thick wiremesh and aluminium clading etc. length as required The DG sets shall include the cost of all accessories, Acoustic enclosure as per CPCB ,Fuel system and Emission as per latest MOEF guidelines, fittings, protections, instruments, safety controls, alarms, indications etc. complete as per specifications, as required The work should be as per Central Electrical Inspectorate/ Pollution control board standards.

1

-

-

... More
MAIN LT CUM DG SYNC. PANEL TTA Assembly (IEC-61439-Part 1&2) Supply, Installation, Testing and Commissioning of cubicle LT panel as per IEC 61439-1 & 2, IP42, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system, tested for 12kV impulse withstand voltage,form 4b construction, fabricated in compartmentalized modular design from CRCA sheet steel of 2 mm thick for frame work and covers, , plates i/c cleaning & finishing complete with 8 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars for high conductivity, SMC bus bar supports,with short circuit withstand capacity of 50 KA for 1 sec ,internal arc type tested as per IEC 61641 50kA for 0.3sec at HBB,VBB & Cable Chamber,bottom base channel of MS section not less than 100mm x 50mm x 3mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar sized for prospective earth fault , solid / flexible connections from main bus bar to switchgears and from switchgear output to cable termination in cable alley with required size of AL conductors / bus bars and control wiring with 2.5 sqmm PVC insulated copper conductor cable (FRLS), cable alleys, cable gland plates , i/c providing following switchgears / accessories as per specifications. Panel shall be completed in all respect and must follow tech specs . INCOMINGS FROM 750KVA & 500KVA DGs : 03 Nos. from 750KVA DG Sets- 1250 Amps. each four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics = Icu up to 433 V) EDO operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/ isolated position indicators and frame earthing contact, confirming to IS : 13947-2, 1993 as amended up to date complete with following accessories for each ACB. 01 No.from 500KVA DG Sets- 800 Amps. four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics = Icu up to 433 V) EDO operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/ isolated position indicators and frame earthing contact, confirming to IS : 13947-2, 1993 as amended up to date complete with following accessories for each ACB. (i) Independent Electrical spring closing mechanism - 1 No. (ii) Microprocessor release (EMI & EMC Certified) for over current, earth fault & short circuit protection - 1 Set. (iii )Intelligent multifunction digital meter to read V, A, KVA, KWH, PF Hz etc. having RS 485 port and compatible to PC with modbus protocol with 3 Nos. resin cast CTs of 1250/5 A class 1.0 accuracy and 15 VA burden. - No. Set of selector switches. Push buttons for Test, Accept, Reset, Fault Reset, Engine Start, Engine stop, ACB close, ACB Trip Emergency stop etc. 6 Nos. manual/auto AMF toggle switches. PLC Hardware & software programmes as required and as per specifications. Auxiliary relays as required and as per specifications.

1

-

-

... More
SCADA System Supply and installation of Window based scada software for visualization of SLD, Data Logging and Event Logging of DG, H.T. & L.T. System in Substation. The SCADA System Comprising of Following: a) Energy Management System with all Multifunction meters communicated with Beldon cables from Panelboard to SCADA System b) HMI Unit in Panel Boards (For Display of Temperature inside the Panel) c) Neccessory PLC and Control Cards (I/O Devices) d) 46" LED Display Unit (Monitor) for Visualization of Data e) EMS Software Control Room Equipment a) Desktop PC: Processor: Core2Duo 2.4/2.6GHz, MB:-Intel Original with PCI Slots and 1 LAN card, Hard disk: 320 GB, RAM 4GB, with Monitor (17: TFT), Keyboard, Mouse, Window XP/7 Operating System, Antivirus. b) Online UPS of Size 3kva with Battery backup of 30 Min. or HA Data Storage(Make APC/Luminous/MicroTech) c) Printer : for report printing

1

-

-

... More
HYBRID APFC PANEL IGBT based automatic Hybrid Power Factor Correction panel, 14% de-tuned filter (150Amp Active + 250kVAr Passive) consist of following switch gears and accessories. Design, fabrication, assembly, wiring, supply, erection, testing and commissioning of Hybrid Solution consisting of APFC Panel and AHF, to achieve 0.99 Lag and THDI/ THD Voltage within IEEE 519 limits, fabricated of CRCA sheet of thickness 2 mm and 3 mm thick gland plates. (Panel shall be designed with appropriate heat ventilation and separation of components in form 3B). The Hybrid panel shall have an incomer of 630 Amps, 3 Pole, MCCB with microprocessor based release having short circuit, over current, earth fault protection. The Active harmonic filter of 150 A Ampere and adequate capacity of FP MCCB of fault breaking capacity 50KA (Ics=lcu=50KA for 1 sec at 440V) with short circuit, over current as incomer AHF(active) and APFC (passive) section shall be provided and interfaced with a common door-mounted human machine interface (HMI) with touch screen display and communication port RS 485 for Modbus/ Ethernet protocol with necessary hardware, software, CTs etc. HMI shall provide an oscilloscope feature to display specific parameters. In addition, performance trend curves shall be displayed for load - total RMS current, load RMS harmonic current per phase, AHF harmonic current output per phase, AC mains voltage per phase, THDi, TDD, load RMS reactive current, and AHF RMS reactive current output. Bar graphs shall be provided for display of the mains and load harmonic current amplitudes per harmonic order. HMI shall display a flashing warning screen in the event of a fault. The Capacitor Panel (Passive Section) shall comprise of capacitor units rated at 525 volt, 14% de-tuned reactors, PF controllers, circuit breakers etc. and shall be certified as per IS16636 and IEC 61921. The AHF shall be 3 Phase, 4 Wire System. The switching device of the active compensation system shall be level 3 IGBT based. The active compensation system should filter harmonics from 2nd to 51st individual harmonic order and shall be selectable for the entire range. The active compensation system shall also have feature to improve PF correction as well as load balancing. The active compensation system shall have a Multi master and Master Slave operation. The active compensation system shall have Auto de-rating feature, if ambient temperature exceeds 45 Deg C. Response time shall be 100 micro Sec or less. The reactor shall be fitted with a temperature sensitive switch to trip circuits in case of high operating temperature. The hybrid panel shall have microprocessor based integrated/ duly interfaced separate DSP controller for Active and Passive section and shall be able to sense the reactive current requirement of the network and shall switch ON/ OFF the required stages of a capacitor bank. The Capacitor Bank shall be of Partially type tested design as per IS 16636/ IEC 61921. The heavy duty capacitor units shall be rated at 525V. The capacitor and reactor combination represents a series resonant circuit. The circuit should be tuned such that the series resonant frequency should be below the lowest harmonic order expected to be present in the electrical network. If the lowest harmonic order expected to be present in the electrical network is likely to the 150Hz (3rd order harmonics) then the series de-tuning reactors should be of 135Hz (2.7 tuning order) with a relative impedance of 14%. The Hybrid Solution should comprise of Active filter i.e. 150A and Passive i.e. 250 KVAr. - The Active harmonic filter shall have adequate capacity of FP MCCB of fault breaking capacity 50KA (Ics=lcu=50KA for 1 sec at 440V) with having short circuit, over current, protection as incomer - The 14% de-tuned capacitor bank with capacitor duty contactor suitable for following step ratings: - 25 KVAR - 2 Sets and each set cosists of one no. 63 Amp TP MCCB, (Ics = Icu = 36 KA)

2

-

-

... More
Gas Based Fire Suppression System FIRE TRACE TUBE SUPPRESSION SYSTEM - ELECTRICAL PANELS

-

-

-

... More
4 Kg, Clean Agent (FK 5-1-12), Fire Extinguisher Clean Agent with Zero Ozone Depletion Potential. Container along with valve assembly.

5

-

-

... More
Heat Sensor tube for automatic fire suppression system made by special modified Polyamide (PA), Colour Black, High grade HR quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM.

200

-

-

... More
End of Line adapter for Pressure gauge fitting for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Maximum working pressure 25 Bars.

10

-

-

... More
End of Line Plug for Automatic fire suppression tube used for fitting at the tube end to terminate the point. Maximum working pressure 25 Bars.

10

-

-

... More
Pressure Switch

5

-

-

... More
Audio Visual Alarm

5

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C.made up with metal clad enclosure having current Density of 130 AMP/Sq.cm. at nominal current Rating,made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, adopter box and copper flexible for joints, continuous earthing with 2 Nos Auminium strip of 5mm X 40 mm (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required

-

-

-

... More
2500 amps 50KA SC for 1 sec

100

-

-

... More
SAFETY EQUIPMENTS

-

-

-

... More
Supplying of Rubber hand gloves suitable for 11 kV.

2

-

-

... More
Supplying and fixing of Shock treatment chart both in Regional, Hindi & English.and framed with 5mm thick glass as required.

2

-

-

... More
Supply & fixing HT danger notice plate of 250 mm x 200mm, made of mild steel sheet of at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required. (11 kV)

2

-

-

... More
Supply of First aid box containing material as prescribed by St. John Ambulance brigade OR Indian Red Cross complete as required.

2

-

-

... More
Providing of synthetic Insulation mat 1 meter wide & 25mm thick to withstand 12kV dielectric strength as per IS 15652- 2006

20

-

-

... More
Providing Single Line Diagram on 5mm thick Aluminium sheet in A0 Size duly laminated.

1

-

-

... More
Providing Single Line Diagram on 5mm thick Aluminium sheet in A1 Size duly laminated.

1

-

-

... More
EARTHING (SUB-STATION EQUIPMENTS & DG SET)

-

-

-

... More
Earthing with copper earth plate 600mm x 600mm x 3.0mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal and salt complete as required.

10

-

-

... More
Earthing with GI earth plate 600mm x 600mm x 6.0mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal and salt complete as required.

5

-

-

... More
Providing & fixing of 50mm x 5mm GI strip on surface or recess for earth connection as required.

100

-

-

... More
Providing & fixing of 65 mm x 8 mm GI strip on surface or recess for earth connection as required.

100

-

-

... More
Providing & fixing of 75mm x 10mm GI strip on surface or recess for earth connection as required.

100

-

-

... More
Providing & fixing of 50mm x 5mm copper strip on surface or recess for earth connection as required.

100

-

-

... More
Supply and Laying of GI Pipe for running GI/Copper strip for earth connection as required and as per specifications. 80 mm inner dia

100

-

-

... More
Supply of following sizes of XLPE insulated PVC sheathed aluminium conductor armoured power cable of 11 kV grade conforming to IS 7098 (Part-II) amended upto date. 3 Core, 300 Sq.mm.

200

-

-

... More
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 Sqmm

12

-

-

... More
Supply and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300 sqmm 11 kV XLPE cable

2

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing Cable tray as required. Above 185 sq. mm and upto 400 sq. mm

50

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing Cable tray as required. Above 120 sq. mm and upto 400 sq. mm

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq.mm and upto 400 sq.mm.

25

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 11 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq.mm and upto 400 sq.mm.

25

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC / HUME / METAL pipe as required. Above 120 sq.mm and upto 400 sq.mm.

50

-

-

... More
Laying of PVC insulated and PVC sheathed/ XPLE power cable of 11 kV grade of following size in hard rock soil, including road, rock cutting, protective covering and refilling and making good cutting areas etc. as required. Above 120 sq.mm and upto 400 sq.mm.

25

-

-

... More
Supplying of following sizes of 1.1 kV grade PVC insulated copper conductor armoured stranded Control Cable conforming to IS :1554 complete as required and as per specifications.

-

-

-

... More
3 core, 2.5 Sq.mm. Cu. Conductor cable

100

-

-

... More
4 core, 2.5 Sq.mm. Cu. Conductor cable

100

-

-

... More
7 core, 2.5 Sq.mm. Cu. Conductor cable

100

-

-

... More
12 core, 2.5 Sq.mm. Cu. Conductor cable

100

-

-

... More
19 core, 2.5 Sq.mm. Cu. Conductor cable

100

-

-

... More
Supply of following size of 1.1kv grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS: 7098:1988 (Part - I) with upto date amendments.

-

-

-

... More
3.5 core, 400 Sq.mm.

400

-

-

... More
3.5 core, 300 Sq.mm.

500

-

-

... More
3.5 core, 240 Sq.mm.

200

-

-

... More
3.5 core, 185 Sq.mm.

100

-

-

... More
3.5 core, 120 Sq.mm.

100

-

-

... More
3.5 core, 95 Sq.mm.

100

-

-

... More
3.5 core, 50 Sq.mm.

100

-

-

... More
3.5 core, 35 Sq.mm.

100

-

-

... More
3.5 core, 25 Sq.mm.

100

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1kV grade of following sizes on existing cable tray etc. as required.

-

-

-

... More
Upto 35 sq. mm

350

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

1500

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Upto 35 sq. mm

50

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

400

-

-

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of the following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.

-

-

-

... More
Up to 35 sq.mm

50

-

-

... More
above 185 sq.mm. and upto 400 sq.mm.

100

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushionning, protective covering and refilling the trench etc as required.

-

-

-

... More
Up to 35 sq.mm

50

-

-

... More
above 185 sq.mm. and upto 400 sq.mm.

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required.

-

-

-

... More
Up to 35 sq.mm

100

-

-

... More
above 185 sq.mm. and upto 400 sq.mm.

500

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE powercable of 1.1 kV grade of following size on wall surface as required.

-

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

100

-

-

... More
Supplying and making end termination with double compression brass gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3.5 core, 400 Sq.mm.

20

-

-

... More
3.5 core, 300 Sq.mm.

10

-

-

... More
3.5 core, 240 Sq.mm.

10

-

-

... More
3.5 core, 185 Sq.mm.

6

-

-

... More
3.5 core, 120 Sq.mm.

6

-

-

... More
3.5 core, 95 Sq.mm.

6

-

-

... More
3.5 core, 50 Sq.mm.

4

-

-

... More
3.5 core, 35 Sq.mm.

4

-

-

... More
3.5 core, 25 Sq.mm.

4

-

-

... More
Supply and installing following size of galvanised iron Lader type cable trays with radil bends supports, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders etc as required.

-

-

-

... More
1000 mm width x 60mm depth x 2 mm thickness.

100

-

-

... More
600 mm width x 60mm depth x 2 mm thickness.

100

-

-

... More
Supply and installing following size of galvanised iron perforated type cable trays including with perforation not more than 17.5%, in convenient sections horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders etc as required.

-

-

-

... More
450 mm width x 60mm depth x 2 mm thickness.

100

-

-

... More
Dismantling & shifting of existing DG set (03 nos of 500 KVA Rating) , DG panels and dismantling of existing AMF Panels, foundation and associated accessories, including shifting the same from the AAI substation to dismantle items store located not more than 200 metres away.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.