The Himachal Pradesh State Industrial Development Corporation Limited Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
The Himachal Pradesh State Industrial Development Corporation Limited - HPSIDC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Jul 2024
Closing Date5 Aug 2024
Tender Amount₹ 39,42,879
Costs
EMD
₹ 78,900Document Cost
₹ 4,700Tender Fee
Refer Documents
Summary
Construction Of State Of Art Fisheries Training Centre At Gagret Distt. Una (hp).(sh- Providing E.i. ,street Lighting And Fire Fighting System Thereof).
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SIDC_91018_1Bid Award Id
ViewTender No
Job No. 13Tender Authority
The Himachal Pradesh State Industrial Development Corporation Limited ViewPurchaser Address
-Website
http://hptenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
4x 4+2x 4 Sqmm
120
-
-
2x4.0 Sq. mm.
160
-
-
4x6+2 x 6
80
-
-
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
12
-
-
Supplying and drawing co-axial TV cable,RG-6 grade,0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
100
-
-
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-(i) 25 mm. dia
60
-
-
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:- (i) 2 modules (78mmx78mmx50mm)
12
-
-
(ii) 6 modules(205mmx78mmx50mm)
12
-
-
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (i) S.P. 5/ 6 Amps one way Modular switch.
36
-
-
(ii) 5 pin, 5/ 6 Amps Modular socket outlet.
36
-
-
(iii) TV socket outlet, Modular.
12
-
-
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.
39
-
-
Supplying and fixing G.I. Modular box with modular plate and cover in recess including providing and fixing 5Pin6 amp modular socket and 5/6 amp modular switch 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
33
-
-
Supplying and fixing Bell Indicator. single phase,230 volts complete as required:-
1
-
-
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
1
-
-
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (i) Single pole. Cat-A.
65
-
-
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps. Cat-A.
8
-
-
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps. Cat-A.
2
-
-
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amps. Cat-A.
2
-
-
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision to mount 8 module incomer, 2 module sub-incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (a) Double door-2+8 way (8+6+24),horizontal type
2
-
-
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but with charcoal or coke and salt ) complete as required.
2
-
-
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required.
40
-
-
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- (i) 10 ltr
1
-
-
(ii) 25 Liter capacity water heater (Cat-A)
2
-
-
(iii) 35 Liter capacity water heater (Cat-A)
10
-
-
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, Light duty, (i) 300 mm sweep
8
-
-
(ii) Exhaust Fan, Heavy duty, 300 mm sweep in/c fan shutter if required
5
-
-
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to required length] with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:Model to be got approved.- (a) Ceiling Fan 1200 mm sweep, Category-A
39
-
-
(b) Ceiling Fan 1400 mm sweep, Category-A
1
-
-
Supplying and fixing of fancy wall bracket Led/LED Batten of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. (i) Wall Light fixture Polycarbonate body suitable for 9 watt Retro fitt Led Lamp B22 base
16
-
-
(ii) Mirror light/ jaguar
2
-
-
(iii)Led Batten 20 Watt Al Housing
8
-
-
(iv) Led Batten 10 Watt Al Housing
6
-
-
Supplying & fixing surface mounting fitting 1'x 1' LED luminaire panel of WIPRO//Philips/ Trilux20 / 24WH with Aluminium die cast Housing as required.
9
-
-
Providing & fixing surface/ recess mounted 12/ 15W LED fitting of Wipro/Havells/Philips/ as required complete in all respect with Aluminium die cast Housing as required. (i) 9 Watt
20
-
-
(ii) 12/15/Watt
40
-
-
(iii) 18/20 Watt
40
-
-
Providing & fixing efficient LED panel surface/Recess2x 2/ 4x 1ft-36 watt of Wipro /Philips/ Trilux complete in all respect fitting in ceiling as approved & directed by engineer in charge with Aluminium die cast Housing as required..
15
-
-
Supplying & fixing Decorative Light Fitting of 6 LT frosted Glass with chrome finish Chandelier E14 LED 4Wx 6 of phillipse/havells/jaquar and equivlent to Jaquar code JNL-CHR - MD 160275216A complete in all respect fitting in ceiling as approved & directed by engineer in charge.
1
-
-
Supply, installation, testing & commissioning of 1.5TRHot &(cold) split type air conditioning unit with remote of following make complete as required in all respect with Base Frame , Refrigent copper piping , Hard PVC /Flexible drain pipe, PVC Round Cover 50mm dia upto required length including stabilizer & stand for AC as approved & directed by engineer in charge in/c Modular industrial socket with mcb of required rating. Voltas/,Lloyd,LG, Blue Star Daikin 1.5 Ton
2
-
-
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to required) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Model to be got approved from engineer in charge. (a) Ceiling Fan 1200 mm sweep Fusion Metallic Beige Brown /Pearl Ivory-Gold Havells
2
-
-
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-The cost includes cost of cities ammeter, voltmeter , selector swtiches LED Lamps and other items required at site to the best satisfaction of engineer in charge.The panel is to be fabricated for mounting of accessories as per the direction and approval of engineer in charge.+The manufecture of panel along with drg is to be got approved before fabrication from the Engineer in charge. (a) 450mm deep (nominal)
1.5
-
-
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required.
2
-
-
Supplying and fixing copper strip bus-bars suitable for 300 Amp. 415 volts capacity 4 No. each of cross-sectional area (31.75mmx6.35mm),in the existing enclosure with all accessories including connections etc. as required.
1
-
-
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required. (i) 100 Amp. -10 KA
4
-
-
(ii) 200 Amp. -16 KA
1
-
-
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:- (a) Armoured cable 6 sq. mm (twin core)
50
-
-
(b) Armoured cable 10 sq. mm (twin core)
50
-
-
© Armoured cable 95 sq. mm (3.5 core)
40
-
-
Supplying and drawing LAN cable CAT 6E, solid copper conductor protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
40
-
-
Supplying and drawing following pair for internet in the existing surface / recessed, steel / PVC conduit as required. (a) 4 Pair
30
-
-
Supplying and fixing 30 Amps, 415 volts, TPN industrial socket outlet, 4-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate and cost of 30 Amp TPN-MCB, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
6
-
-
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but with charcoal or coke and salt ) complete as required.
2
-
-
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
40
-
-
P/F Exterio Square Wall Light up-down4 watt of Wipro/Phlips/Havell asapproved by the Engineer -in -charge
10
-
-
Providing & fixing watt LED street light fitting ln white colour with pressure die- cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection. W/ White ) complete in all respect.The fitting is to be fixed on existing bracket mounted on pole/on wall including wiring etcas required as approved and directed by engineer in charge of Wipro/ Philips/ Havells make.
5
-
-
P/F 5 mtr Decorative Pole made of galvinised Mild Steel pipes fitted with cast aluminum embelish ments Polyurethane paint coated of May Fair cat no MFMD 108-A havingH1 139.79 (1m) H2 76.1 (5m) B.P 340x 10mm along with Bracket of May Fair as product code MF-38 Pole with foundation bolt single arm bracket complete in all respect of or make in/c MCB. connector and connection from connector to fittings approved by Enginer-in -Charge
5
-
-
Fire Fighting System : Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) to be got approved by Engineer-in-charge.
-
-
-
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.
-
-
-
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
-
-
-
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
-
-
-
Suitable cement concrete foundation duly plastered and with anti vibration pads.
-
-
-
450 lpm at 35 m Head
1
-
-
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter- connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required. As per direction of Engineer-in-Charge.
-
-
-
125A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-200V with selector switch
Digital Ammeter (0-125 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Al Bus Bar 200A
-
-
-
63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload Set protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.- 2sets
1
-
-
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required (Jindal Hissar/ TATA) : (a) 100 mm dia
90
-
-
(b) 80 MM
20
-
-
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required Sant/Zoloto : 100mm dia As per direction of Engineer-in-Charge.
3
-
-
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange (Kartar/DRP). 100 mm dia As per direction of Engineer-in-Charge.
1
-
-
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel As per direction of Engineer-in-Charge.
6
-
-
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. As per direction of Engineer-in-Charge.
7
-
-
Supplying & fixing 63 mm dia SS short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required (Kalpex/Padmini/Aag ) As per direction of Engineer-in-Charge.
7
-
-
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe As per direction of Engineer-in-Charge.
1
-
-
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. As per direction of Engineer-in-Charge.
1
-
-
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. As per direction of Engineer-in-Charge.
1
-
-
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required (Kalpex/Padmini/Aag ) As per direction of Engineer-in-Charge.
7
-
-
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required (Sant/Zoloto): 100 mm dia
7
-
-
Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc. As per direction of Engineer-in-Charge.
7
-
-
Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect As per direction of Engineer-in-Charge. (Kalpex/Safex). 4 Kg
10
-
-
Providing and fixing of FIRE EXTINGUISHER, CO2 type as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect (Kalpex/Safex) As per direction of Engineer-in-Charge.. 4.5 kg
10
-
-
P/F G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. As per direction of Engineer-in-Charge.25mm dia nominal bore.
50
-
-
Providing & placing on terrace (at all floor levels) polyethylenewater storage tank, IS: 12701 marked, with cover and sutible locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings abnd the base supportsfor tank. As per direction of Engineer-in-Charge.
6000
-
-
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required complete with 2 nos Battery .MAke RAvel/SYstem Sensor . 4 Zone Panel As per direction of Engineer-in-Charge.
1
-
-
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc UL listed as required make Ravel/ Edward As per direction of Engineer-in-Charge.
24
-
-
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
12
-
-
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.Make Ravel/System Sensor
2
-
-
Supplying, installation, testing & commissioning response indicator built in metal on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required As per direction of Engineer-in-Charge..
10
-
-
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required As per direction of Engineer-in-Charge.
1
-
-
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required As per direction of Engineer-in-Charge..Make Polycab/KEI
200
-
-
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- Armoured cable 35 sq. mm (3.5 core)
50
-
-
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but with charcoal or coke and salt ) complete as required.
2
-
-
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required.
40
-
-
HVAC/Air conditioning: Supplying of 3.8 TR CASSETTE AC Non Inverter Cooling only , WITH R-32 ,AIR FLOW 1288/1165/1024/882 CFM, SOUND PRESSURE LEVEL IDU 46/43/40/36DBA &ODU 60DBA.Cooling capacity 3.8 TR BTU/h 48000 (cooling ) . Power consumption 4.2kw (cooling) Operation Range (Cooling )Indoor temp.27 degee CDB , . (a) A.C. unit 3.8 Ton capacity Make:- DAIKIN , O GENERAL , TRANE
5
-
-
Refrigerant Piping: Providing of copper tube for refrigent size (9.52mm -15.88mm) for 3.8 tr ceiling mounted cassette type AC unit and satisfacation of Engineer-In-Charge.
75
-
-
Nitrile Tubular Insulation for ac indoor to outdoor for COPPER PIPING size 9.52mm-15.88mm dia with 13mm thickness and satisfacation of Engineer-In-Charge.
75
-
-
Drain Piping: Condensate drain water piping with all necessary fittings - PVC 25mm with 6mm thick Nitrile Insulation and satisfacation of Engineer-In-Charge.
65
-
-
Cable Tray: Providing of Ms Galvanised cable tray size 150 X 35 with cover and satisfacation of Engineer-In-Charge.
70
-
-
Gas Charging: Providing and re-filling refregerent R-32 to top up and balance the refregerent Volume in the AC Circuit as required and satisfaction of Engg. -In -Charge
12
-
-
MS Stand: Supply of MS Febricated Stand for the Outdoor Units duly painted with Black paint and satisfacation of Engineer-In-Charge.
290
-
-
Control & Transmission Wiring: Communication Wire between from each indoor to outdoor units of 4 core 2.5mm with satisfation of Engineering In Charge
280
-
-
Providing and fixing Division Plate for Urinals 600mm x 300. Vitreous China including carriage of material within all leads and lifts.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements