Public Works Department Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Public Works Department - PWD Tender
Eprocure
Opening Date17 Jun 2021
Closing Date25 Jun 2021
Tender AmountRefer Documents
Costs
EMD
₹ 14,500Document Cost
₹ 350Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_PWD_48658_1Bid Award Id
ViewTender No
PW-EDU-CB-TA-Tender-2020-21- 953-78 Dt-04-06-2021Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://hppwd.hp.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2x1.5 Sq. mm.
130
-
-
2x6.0 Sq. mm.
140
-
-
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make: KEI/Anchor/Phenolex/Polycab.
10
-
-
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.
-
-
-
3x1.5Sq.mm.
60
-
-
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Make: L&T /Legrand/Hager/ABB/Schneider/Siemens
-
-
-
a) 6Amp Single pole Cat.A.
34
-
-
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Make: L&T/ Legrand/Hager/ABBSchneider/Siemens
-
-
-
a) 40Amp Double pole. Cat.A.
11
-
-
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Make: L&T/ Legrand/Hager/ABB/Schneider/Siemens
-
-
-
a) Double Door- 12 way
9
-
-
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
2
-
-
Extra for using salt and charcoal for pipe earth electrode complete as required.
2
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.
30
-
-
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
18
-
-
Providing and fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required.Make: L&T/ Legrand/Hager/ABB/Schneider/Siemens
-
-
-
a) 100Amp Category-A.
1
-
-
b) 63 Amp. Category-A
3
-
-
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:- (L&T/Legrand/Schneider/Siemens or its equevalent as approoved by the engineer incharge make)
1
-
-
Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required: (L&T/Legrand/Schneider/Siemens or its equevalent as approoved by the engineer incharge make)
3
-
-
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Make Bajaj/Usha/Crumpton
-
-
-
a) Exhaust Fan, Light duty, (Domestic) 300 mm sweep
6
-
-
Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required.
-
-
-
S.P. 5/ 6 Amps one way switch, piano type.
6
-
-
5 pin 5/ 6 Amps socket outlet, porcelain base/ piano type.
6
-
-
Supplying and fixing of exhaust fan louver shutter for 300mm exhaust fan on the existing wall painting etc. as required.
4
-
-
Providing and fixing LED surface/pendent mounting tube fixture 20 watts LED batten with five year warranty anodized extruded aluminium housing high transmissibility diffuser and it should be compartible with specifications i.e power factor 0.9, Harmonic distortion 10% & efficacy 100 Lumens per watts, CRI80, 5700K suitable for input voltage 220-240 volts, 50 HZ, Length 1175x30x36mm complete wiuth connections and asper best satisfaction of Engineer-in-charge complete as required, (Panasonic /Philips/Jaquar /Wipro make).
9
-
-
Suipplying and laying G.I. pipe of 40mm dia (Heavy duty) underground 1.00 mtr. Below ground level for laying the wire/cable etc. as required.
10
-
-
Supply of 9 watt IP 66 Weather Proof Round Surface Mounted fixture with five year warranty PC housing with Polycarbonate diffuser with minimum LED lumen output 610 lumen with P.F0.95 with THD10%, CRI 80, Surge protection 2Kv with IP Protection of IP65. The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at 1.70. The LEDs used in the luminaire shall have CCT of ANSI Bilm 6000 K for glare free lighting with CRI of minimum 8-0. LEDs used must be Input voltage range shall be 150V. Driver Output voltage shall be less than SELV Limits for safe operation and maintenance , Wipro Cat. No. LW01-101-XXX-60-XX /Philips/Jaquaror equivalent make complete with connections etc. as required.
152
-
-
Supplying and fixing LED Lamp 9 watts 6500 K E-27, 900 Lumens 240 volts AC supply 50 HZ, in the existing batten holder pendent holder wall bracket & bulk head fittings etc. as required (Wipro/Panasonic/Philips /Jaquar make).
18
-
-
Supplying and fixing exhaust fan louver shutter for 300mm , exhaust fan on the existing wall, painting etc. as required.
6
-
-
Supplying and fixing of 45 watt, Pole mounted IP66 Street Light (with Five year waranty) System efficacy of 110 Im/W. LED Street Light shall be made up of Die cast aluminium Housing for better heat decapitation. L70 life of 50000 Hrs. The LEDs in Street Light should be with CCT of 5700 Kand CRI of Minimum 70, Input voltage range of 150V to 270V(nominal rated voltage-240V) with 4KV surge protection. Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED driver shall have output short circuit & over voltage protection inbuilt, wipro Cat. Code: LR13-611-XXX-57-XX or in Philips: BRP4-09 LED 039CW HO NR FG SI PSU GR & Trilux: LSL 4000-860 ET or its equivalent.
5
-
-
Supplying and fixing of wall fan 450mm sweep Air Circulator Fans Crompton/Bajaj/Usha make on the existing wall complete with connections etc. as required.
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements