Public Works Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Public Works Department - PWD Tender

Works
Real Estate Service
Eprocure
Opening Date7 Sep 2024
Closing Date13 Sep 2024
Tender Amount₹ 19,39,867 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Engine mounted Instrument Panel fitted with and having digital display for following:

-

-

-

... More
(i) Start-stop switch with key

-

-

-

... More
(ii) Water temperature indication

-

-

-

... More
(iii) Lubrication oil pressure indication

-

-

-

... More
(iv) Lubrication oil temperature indication

-

-

-

... More
(v) Battery charging indication

-

-

-

... More
(vi) RPM indication

-

-

-

... More
(vii) Over speed indication

-

-

-

... More
(viii) Low lub. Oil trip indication

-

-

-

... More
(ix) Engine Hours indication

-

-

-

... More
(X) Turbo charger

-

-

-

... More
Alternator :

-

-

-

... More
Synchronous alternator rated at 100 KVA 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with Class -F/H insulation . The voltage regulation should be (+)1% at all load between no load to full load & factor 0.8 to unity with extended cable Termination Box. having Aluminium Bus -Bar of suitable cross section shall be able to accommodate 2 Run of 3.5 Corex400Sq.mm. XLPE cab;le . The alternator should be of Stamford/Kirloskar/ Leroysomer/ Mitsubishi Caterpillar make only).

-

-

-

... More
Acoustic Encloure Base Frame & Foundation:

-

-

-

... More
Specially desigined to meet stringent MoEF/CPCB-IV+ norms of 75 dBA @ 1 mtr at 75% load under under free conditions. The acoustic enslosure is made CRCA sheets in munsel green shade and structural/sheet base fame painted in black high quality noise absorbant and fire-retardant grade acoustic insulation material (P.U foam) complying to IS 8183. Both the engine and alternator shall be mounted on suitable base frame made of MS channel The foundation shoud be designed safe bearing capacity of soil. The depths of Plain cement concrete foundation is minimum 400 mm and foundation height should be at least 300 mm above the ground level. The length and breadth of foundation should be at least 250 mm more on all sides than the size of enclosure.The Gen set should be mounted on Anti vibration isolation arrangement as per recommendations of manufacturer.

-

-

-

... More
Fuel Tank:

-

-

-

... More
Daily service fuel tank of 220 + 5% liters minimum capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. There should be provision of fuel tank of fuel guage ,which should be show the level of the fuel even when the DG set is not running . the guage should be calibrated .The fuel tank should be filled from the outside as automobiles and should be with a lockable cap. Complete with valves, level indications & accessories as required as per specifications.

-

-

-

... More
Exhaust System:

-

-

-

... More
Dry exhaust mainfold with hospital exhaust silencer and catalytic convertor.

-

-

-

... More
12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable 1 no of battery ,180 Amp. Hour capacity lead acid type) including 50sqmm copper cable .The battery should be accommodate in battery rack as required as per specifications.

-

-

-

... More
Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere.There should be 2 nos 10 watt LED tubes provided inside the enclosure controlled by a 5 amp switch for adequate lighting during service.The power supply to this luminaire should be load side of the AMF panel. as per specifications.

-

-

-

... More
AMF PANEL

-

-

-

... More
Fabricating, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 100KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following:

-

-

-

... More
2 Nos.4 pole MCCB 200 AMP for D.G and main Contactor

-

-

-

... More
2 nos. Mains contactor and DG Contactor 200amp

-

-

-

... More
Auto/Manual/Test/Off selector switch

-

-

-

... More
2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay.

-

-

-

... More
3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering

-

-

-

... More
Energy analyser unit to indicate current voltage frequency power factor and KWH

-

-

-

... More
Digital ammeter voltmeter

-

-

-

... More
Indicating lamps for load on mains and load on set

-

-

-

... More
Fuse for instruments

-

-

-

... More
Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.

-

-

-

... More
Main supply failure monitor

-

-

-

... More
Supply failure timer

-

-

-

... More
Restoration timer

-

-

-

... More
Control unit with three impulse automatic engine start/stop and failure to start lockout.

-

-

-

... More
Impulse counter with locking and reset facility.

-

-

-

... More
ON/OFF/Control circuit switch with indicator

-

-

-

... More
Audio/Video annunciation for

-

-

-

... More
(i) High water temperature

-

-

-

... More
(ii) Low lubricating oil pressure

-

-

-

... More
(iii) Engine over speed

-

-

-

... More
(iv) Engine fails to start

-

-

-

... More
(v) Full load/maximum load warning

-

-

-

... More
vi Signal cable appropriate size

-

-

-

... More
Supplying and fixing exhaust gas piping of 4 inch dia. welded black MS, B Class pipe conforming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool,50 mm thick wiremesh & aluminum cladding etc., as complete in all respect as required as per PWD specifications to the best satisfaction of Engineer-in-charge.

1

1396700

1396700

... More
Excavation in foundations,trenches etc.,in earth work,lift up to 1.50 mtr.stacking the excavated soil not more than 3 mtrs.clear from the edge of the excavation and then returning the stacked soil in 15 cm.layers,when required in to plinths sides of foundations etc.,consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as direct with in a lead of 20 mtrs.in pick jumper work.

2.9

523

180.6

... More
Providing form work with steel plates 3.15 mm. thick welded with angle iron in frame 30x30x5 mm.so as to give a fair finish including centring,shuttering,strutting and propping etc.,with wooden battens and ballies,height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for insitu-reinforced concrete & plain concrete work in: vertical surfaces such as walls (any thickness) pertitions and the like including attached pillasters buttresses,plinth and string courses and the like.

2.5

396

158.6

... More
Providing and laying cement concrete 1:2:4 (1 cement :2 sand :4 graded stone aggregate 20 mm.nominal size)and complete curing to support100KVAwith dimensions and load bearing capacity as specified by OEM excluding cost of form work in Foundation and plinth to the best satisfaction of department.

6.2

38651

6234.1

... More
Providing and fixing M.S.round holding down or Anchor bolts with nuts and washers plates complete as required.

0.3

1657

5525

... More
Providing and laying of PVC round sheathed armoured instrumentation cable 4 core 2.5 sq.mm.copper conductor in existing trench voltage grade upto 1100 volts as required,complete as required.

30

6150

205

... More
Supplying and fixing of following sizes of Heavy Duty 2.0 mm thick ISI marked PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-( BEC/Diplast/Polycab/AKG make)

-

-

-

... More
25 mm. dia

30

2970

99

... More
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-KEI/Polycab/Anchor/Havells/National/Grandlay.

-

-

-

... More
Armoured cable 95 sq. mm (3.5 core)

60

74940

1249

... More
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-KEI/Polycab/Anchor/Havells/National/Grandlay.

-

-

-

... More
Armoured cable 95sq. mm (3.5 core)

20

24500

1225

... More
Supplying and fixing earthing system as per COPPER PIPE 3 meter long and copper strip 3 meter long size 25x3 mm internal strip size and terminal size 50 x6mm with 25 Kg compound including exvation of pit and refiling the same and making earth chamber 320 mm x320 mm x196 mm chamber with cover as required complete in all respect. make :-True power ,Earth plus ,Ashloka or its equivalent as per best satisfaction of Engineer-in -charge.

4

56008

14002

... More
Providing and fixing 25mm x 5mm copper. strip on surface or in recess for earth connections etc. as required.

85

110330

1298

... More
Providing and filling of high speed diesel in 100 KVA D.G.set .

200

17000

85

... More
Annual maintenance contract of 100 KVA DG Set for five years consisting of monthly visit to check the general condition of generator Check and set operation parameters as specified by company Service of engine will be carried out strictly as per company norms and all spare parts changes will be charged extra. Engine oil volume 20 Litr capacity, filter, collant, air filter fan belt etc. complete one service in a year will be carried out strictly as per company norms, checking and monitoring the performance during each visit . To check & ensure optimum performance of Sub assembles of machine, fuel timming, tappet clearance etc. for engines and reset the same as required. To check & set all the fasteners, operation of warning devices, operational parameters of breakdown of engines, if any breakdown occure in D.G. Set, the service engineer will check & rectify the breakdown within 24 hour to the best satisfaction of Engineer-in-charge

1

210040

210040



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.