Public Works Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Public Works Department - PWD Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date18 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 3,68,96,475 
Notes
Download

Costs

Summary

Construction Of Indoor Multipurpose Sports Complex At Kharidi Ground Nadaun,

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Group c

212

908

192496

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 (One point Five) sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class FRLS PVC Conduit having wall thickness minimum 2.0 (Two point Zero) mm , with modular switch, modular plate, suitable GI box and earthing the point with 1.5 (One point Five) sq. mm. FRLS PVC insulated copper conductor single core cable etc as required including carriage of material within all leads and lifts. Make :-Anchor (Roma classic ), L&T (Entice)/ legrand(Myrius) as approved by Engineer-In-Charge

-

-

-

... More
Group c

17

1202

20434

... More
Wiring for twin control light point with 1.5 (One point Five) sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit 2 (Two) way modular switch, modular plate, suitable GI box and earthing the point with 1.5 (One point Five) sq.mm. FRLS PVC insulated copper conductor single core cable etc as require including carriage of material within all leads and lifts. Make :-Anchor /(Roma classic)/L&T(Entice)/ Legrand (Myrius) as approved by Engineer-In-Charge

48

1692

81216

... More
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required including carriage of material within all leads and lifts. Make:-KEI/Finolex/Polycab as approved by Engineer-In-Charge

-

-

-

... More
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

4980

282

1404360

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

1895

395

748525

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

565

564

318660

... More
2 X 10 sq. mm + 1 X 6 sq. mm earth wire

740

696

515040

... More
4 X 4sq. mm + 2 X 4 sq. mm earth wire

870

703

611610

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

180

1061

190980

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

785

1197

939645

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

450

1838

827100

... More
4 X 25 sq. mm + 2 X 6 sq. mm earth wire

145

2573

373085

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required including carriage of material within all leads and lifts. Make:-KEI/Finolex /Polycab as approved by Engineer-In-Charge

-

-

-

... More
3 x 1.5 (Three x One point Five) sq. mm

2720

100

272000

... More
3 x 4 ((Three x Four) sq. mm

1330

220

292600

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required including carriage of material within all leads and lifts Make :-Anchor/(Roma classic)/ L&T (Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge

-

-

-

... More
5/6 amp Modular switch

70

93

6510

... More
5 pin 5/6 amp socket outlet

70

136

9520

... More
Modular Blanking Plate

35

40

1400

... More
Telephone socket

25

159

3975

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required including carriage of material within all leads and lifts. Make :-Anchor /(Roma classic) /,L&T (Entice)/ Legrand(Myrius) as approved by Engineer-In-Charge

263

469

123347

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.including carriage of material within all leads and lifts. Make :-Anchor(Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

161

621

99981

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 (Twenty five) Amps modular SP MCB, “C” curve including connection, painting etc. as required including carriage of material within all leads and lifts.Make :-Anchor(Roma classic) / L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

10

705

7050

... More
Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required including carriage of material within all leads and lifts .Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

15

238

3570

... More
Supplying and fixing modular TV socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required including carriage of material within all leads and lifts. Make :-Anchor /(Roma classic )/L&T (Entice) /Legrand(Myrius) as approved by Engineer-In-Charge

10

159

1590

... More
Supplying and drawing of Polyethylene Foam insulation with laminated aluminum tape and Aluminium wire braided , Jelly filled Black PVC oversheathed Co Axial Cables. in the existing surface/recessed steel/ PVC conduit including conections,as required including carriage of material within all leads and lifts Make KEI(RG-6 CU)/Dlink/Polycab as approved by Engineer-In-Charge

150

40

6000

... More
Supplying and drawing of telephone cable of following pairs high conductivity copper conductor ,with high density polythylene insulation , paired ,polyster,and sheathedwith grey coloured, pvc compound telephone cables generally conforming to ITD specifications in the existing surface/recessed steel/ PVC conduit including conections,as required including carriage of material within all leads and lifts Make KEI/ Dlink/ Polycab as approved by Engineer-In-Charge

-

-

-

... More
2 (Two) pair

500

31

15500

... More
4 (Four) pair

100

47

4700

... More
Supplying and fixing Computer board comprising 3 nos 5 (Five) amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 12 module for 5 amp switchs and 5 amp sockets comprising sheet cover for each 2 module metal box , one no computer jack (RJ-45)with shutter including connections etc as required.Make :-Anchor/ (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge

34

1803

61302

... More
Supplying and drawing of UTP 4 (Four) pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit including conections,as required. including carriage of material within all leads and lifts. Make:- D LINK/Finolex/Belden.

810

52

42120

... More
Supplying and fixing D- link DGS-1016A 16 (Sixteen)-port 10/100/1000 Base - T Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required including carriage of material within all leads and lifts. Make:- D-Link(Code No DGS-1016A)/ Digilin/ Cisco as approved by Enginer-In-Charge

1

8100

8100

... More
Supplying and fixing D- link DGS-1008A 8 (Eight)-port 10/100/1000 Base - T Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required including carriage of material within all leads and lifts Make:- D-Link/ Digilink/ Cisco as approved by Engoneer-In-Charge

5

2790

13950

... More
Supplying and fixing Loaded Wall- Wall Mount 2 (Two) u Dimensions 44 X57 X20 CM Front Glass Door(tinted,toughened) with LOCK &KEY, 2PAIRS OF I9" Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt)3 socket 5amp .power distribution Unit(1NO) .Make:- D-Link /Cisco/ Digi link including carriage of material within all leads and lifts as approved by Engineer-In-Charge

5

1540

7700

... More
Supplying and fixing Loaded Wall- Wall Mount 4 (Four) u Dimensions 550 X400 X20 CM Front Glass Door(tinted,toughened) with LOCK &KEY, 2PAIRS OF I9" Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt)3 socket 5amp .power distribution Unit(1NO) .Make:- D-Link(CAT NO NWR-4U-5540-GR)./Cisco/ Digi link as approved by Engineer-In-Charge

1

4779

4779

... More
Supplying and fixing of following sizes of Heavy class FRLS PVC Conduit having wall thickness minimum 2.0 (Two point Zero) mm along with accessories in surface/recess including cutting the wall and making good as required including carriage of material within all leads and lifts. Make:- Diplast/BEC/Polyfit and as approved by Engineer-In-Charge

-

-

-

... More
25 (Twenty five) mm

1820

99

180180

... More
32 (Thirty two)mm

205

122

25010

... More
50 (Fifty) mm

220

194

42680

... More
100 (One hundred)mm

270

600

162000

... More
Providing and installation of 25 (Twenty five) litre capacity stationary storage type Electric water heater digital display type including five year warranty (Geyser)of various sizes by means of expansion-bolts with nuts and washers, includingembedding of expansion-bolts in the wall, making good the damages, electricalconnections, testing etc. complete as required:-Make:-Usha/Jaquar/Bajaj/Recold and as approved by Engineer-in-charge

10

18178

181780

... More
Providing, Installation, testing and commissioning of BLDC ceiling fan including five year warranty with socket type 2 module regulator,including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mmt win twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required including carriage of material within all leads and lifts.Five star rating Make:- Usha (Technoaire BLDC without remote)/Bajaj/Crompton as approved by Engineer-In-Charge

-

-

-

... More
Ceiling Fan 1200 (One thousand two hundred) mm sweep

14

4651

65114

... More
Supplying and fixing extra conduit down rod of 60 (Sixty) cm length G.I. pipe 15 (Fifteen) mm dia, heavy gauge including painting etc. as required including carriage of material within all leads and lifts(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).

60

169

10140

... More
Supply and fixing of high-quality integrated LED Flood Light 470 (Four hundred seventy) watts +/- 5% with a minimum system lumen of 52800lm and nominal system efficacy ≥110 lumen/watt. The housing should be of non-corrosive high-pressure single piece pressure die-cast aluminium to withstand extreme environments.The Product should be suitable for continuous operation ≥ 12 Hrs. per day),The luminaire shall be IP66 & IK08 compliant. In-built surge protection of 4KV. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown/cut-off at less than 90V & 325V(±15V) and have an auto recovery feature. The LED efficacy shall be ≥ 130lumens/watt (at design operating current and Tj: 85deg C.), CCT: 5700°K, CRI≥90 & SDCM ≤ 5. The LEDs with minimum life of 50000 burning hours.,complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as: (Illumitation level - Indoor Sports :- Clause: 6.2 for non televised event: Indoor Sports for diving, vertical uniformity should be also considered. Class 1: 0.8 Eh/Ev. Class 3: 0.5 Eh/EV.) Glare restriction should be there less then 50- National lighting code SP 72: 2010.Make :- Philips/LT/ Endo/Disano/Leksa as approved by Engineer-In-Charge(five year warranty)

66

46308

3056328

... More
Supply and fixing of high-quality integrated LED Flood Light 300 (Three hundred) watts +/- 5% watts with a minimum system lumen of 38500lm and nominal system efficacy ≥125 lumen/watt. The housing should be of non-corrosive high-pressure single piece pressure die-cast aluminium to withstand extreme environments.The Product should be suitable for continuous operation ≥ 12 Hrs. per day),The luminaire shall be IP66 & IK08 compliant. In-built surge protection of 4KV. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown/cut-off at less than 90V & 325V(±15V) and have an auto recovery feature. The LED efficacy shall be ≥ 130lumens/watt (at design operating current and Tj: 85deg C.), CCT: 5700°K, CRI≥90 & SDCM ≤ 5. The LEDs with minimum life of 50000 burning hours.,complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as:(Illumitation level - Indoor Sports :- Clause: 6.2 for non televised event: Indoor Sports for diving, vertical uniformity should be also considered. Class 1: 0.8 Eh/Ev. Class 3: 0.5 Eh/EV.) Glare restriction should be there less then 50- National lighting code SP 72: 2010.Make Make :- Philips/LT/ Endo/Disano/Leksa including carriage of material within all leads and lifts and as approved by Engineer-In-Charge(five year warranty)

70

41186

2883020

... More
Supply and fixing of 8 (Eight)ft linear suspended fitting 75 (Seventy five) watts +/- 5% watts made of extruded aluminium. Fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt and a minimum system lumen output of 8800(downlight) lumens and nominal system wattage of 75W(Max)with Pressure Die cast Aluminium heat sink . Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance, CRI 80, PF 0.95, and an operating Voltage Range of 140-270VAC. Internal Surge Protection 4KV. Fixture module should have 50 mm width. LED compartment to be independent from the Driver compartment.complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as:Make Philips/Wipro/LT/ Endo/Disano/panasonic/Leksa or as approved by Engineer-in-Charge. (Illumitation level - Indoor Sports :- Clause: 6.2 for non televised event: Indoor Sports for diving, vertical uniformity should be also considered. Class 1: 0.8 Eh/Ev. Class 3: 0.5 Eh/EV.) Glare restriction should be there less then 50- National lighting code SP 72: 2010..Make :- Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

85

13500

1147500

... More
Supply and fixing of 4 (Four) ft linear suspended fitting 22 (Twenty two) watts +/- 5% watts made of extruded aluminium. Fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt and a minimum system lumen output of 2600(downlight) lumens and nominal system wattage of 22W(Max)with Pressure Die cast Aluminium heat sink . Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance, CRI 80, PF 0.95, and an operating Voltage Range of 140-270VAC. Internal Surge Protection 4KV. Fixture module should have 53 mm width. LED compartment to be independent from the Driver compartment. complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as:Make :- Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

42

5665

237930

... More
Supply and fixing of 4 (Four) ft. linear suspended fitting 22 (Twenty two) watts +/- 5% watts made of extruded aluminium. Fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt and a minimum system lumen output of 2600(downlight) lumens and nominal system wattage of 22W(Max) with Pressure Die cast Aluminium heat sink . Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance, CRI 80, PF 0.95, and an operating Voltage Range of 140-270VAC. Internal Surge Protection 4KV. Fixture module should have 53 mm width. LED compartment to be independent from the Driver compartment. Access to the driver should be from the top of the luminaire and not through the diffuser and LED tray to avoid any damage to the diffuser, LED board of LEDs, maintain the linearity of the continuous formation and for ease of maintenance.complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as required including carriage of material within all leads and lifts. Make :- Philips/ LT/ Endo/Disano/Leksa as approved by Engineer-In-Charge(five year warranty)

16

5665

90640

... More
Supply and fixing 4 (Four) ft. linear suspended fitting 18 (Eighteen) watt +/- 5% watts made of extruded aluminium. Fixture should have minimum efficacy at System level (Not Chip Level) 120lumens/watt and a minimum system lumen output of 2200(downlight) lumens and nominal system wattage of 19W(Max). Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance, CRI 80, PF 0.95, and an operating Voltage Range of 140-270VAC. Internal Surge Protection 4KV. Fixture module should have 50 mm width. LED compartment to be independent from the Driver compartment. Access to the driver should be from the top of the luminaire and not through the diffuser and LED tray to avoid any damage to the diffuser, LED board of LEDs, maintain the linearity of the continuous formation and for ease of maintenance.complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as:Make :- Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

12

13500

162000

... More
Supply and fixing of backlit non slim surface/Recess led downlighter in 18 (Eighteen) Watts + 5% watts in Round Shape with with minimum system lumen efficacy of 110 lm/W and minimum system lumens 2000 lumen with Pressure Die cast Aluminium heat sink with and HET diffuser and polycarbonate mounting box P.F.0.95 ,THD10% ,CCT 6500K, CRI 80, UGR23,IP20 protection.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .Fixture have Surge Protection 2.5kV .Driver including ,cutting, hanging arrangement ,complete in all respect. Make :- Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

959

1877

1800043

... More
Supply and fixing of surface/Recessed LED 2x2 (Two x Two) luminaire 25 (Twenty five) watts + 5% watts with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have a color consistency SDCM 5, CRI 80 and CCT of both 4000K / 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3000 nominal lumens andwith Pressure Die cast Aluminium heat sink an outstanding backlit solution efficacy of at least 120 lumen/watt and maximum system wattage of 25Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD 10% and have options for DALI dimmable too. complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as required including carriage of material within all leads and lifts :Make :- Philips/LT/ Endo/Disano/Leksa as approved by Engineer-In-Charge(five year warranty)

452

3511

1586972

... More
Supply and fixing of Decorative functional 2X2 (Two x Two) LED Recess lumianre 36 (Thirty six) watts +5% with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are in line with 2X2 Luminaire. Luminaire should give more volumetric light & higher vertical illumination. Luminaire should be available in minimum 3900 lumens having maximum system wattage of 36W with color temperature of 5700K and CRI80, . The luminaire shall meet IP20 rating with Ripple 5%, THD10% and PF 0.95. The luminaire housing should made of powder coated CRCA with high efficiency PS diffuser and having surge protection up to 4kV. The driver must have operating voltage range from 120-270VAC and EMI/EMC compliantcomplete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as required.Make :- Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

12

12647

151764

... More
Supply and fixing of IP65 Integral LED 4 (Four) ft. batten 20 (Twenty) watts +5% watts . The batten shall have housing made of Polycarbonate Co-extrusion only & the front diffuser shall be made of polycarbonate/polystyrene (Diffuser-Non yellowing type). The end caps shall be made of polycarbonate which are fixed using M3 screws. The LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80.Luminaire shall be designed to deliver minimum system lumen output of 2700lm at a system efficacy of at-least 135 lumen/watt. The measured power consumption shall not be more than 20W & ensuring minimum system lumen output of 2700lm even at lower wattageswith Pressure Die cast Aluminium heat sink . The electronic driver used shall have a power factor ≥0.95 (@full load) and THD ≤10% (@full load), suitable for an operating voltage range of 140-270V AC, Current, Internal surge protection should be minimum 2.5KV, complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as required.Make :-Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

127

3192

405384

... More
Supply and fixing of Integral LED 4 (Four) ft. batten 30 (Thirty) watts + 5% watts. The batten shall have housing made of CRCA Only & the front diffuser shall be made of polycarbonate/polystyrene (Diffuser-Non yellowing type)with Pressure Die cast Aluminium heat sink . The LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80.Luminaire shall be designed to deliver minimum system lumen output of 3900lm at a system efficacy of at-least 130 lumen/watt. Power consumption should not be more than 30W (±5%). The electronic driver used shall have a power factor ≥0.95 (@full load) and THD ≤10% (@full load), suitable for an operating voltage range of 140-270V AC, Current Ripple ≤5% (@full load), Internal surge protection should be minimum 4KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as required including carriage of material within all leads and lifts :Make Philips/LT/ Endo/Disano/Leksa as approved by Engineer-In-Charge(five year warranty)

86

2680

230480

... More
Supply and fixing of LED Track Light Fixture for Target lighting application. Fixture should have minimum lumen package of 5000 Lumen in maximum wattage of 50 (Fifty)Watts. It should have CRI90, CCT options of 3000/4000K, SDCM3,. The fixture can be adjusted 0-320deg with tilt angle adjustment of 0-90deg, it should have beam angle choice of 36deg suiting various application. the fixture sholud be withtrack and Light combination of efficient LED technology and a robust heat sink ensures that this is a reliable and long lasting solution and track shloud be one-phase track with enhanced earthing to ensure safety . Driver should be operated under 220-240VAC, having PF0.9. complete with all cutting, hanging arrangement accessories, connections, testing and commissioning etc as required.Make :- Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

14

5864

82096

... More
Supply and fixing of IP20 Smart PIR Occupancy Sensor having 360 degree Detection Pattern with maximum dectection Diameter of 6 (Six) meters at maximum height of 4 (Four) meters haviing Power consumption of 1.8 (One point Eight) Watts with Off Delay Timing of 1-90 minutes complete with all accessories, connections, testing and commissioning etc.as required. complete with all accessories, connections, testing and commissioning etc.as required. Make :- Philips/LT/ Endo/Disano/Leksa as approved by Er-In-Charge(five year warranty)

88

3887

342056

... More
Supply and fixing of IP65 Bulkhead led fixture 10 (Ten) Watts + 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.0.95 with THD10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 5000K- 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V with 2.5 kV Surge Protection. including ,hanging arrangement ,complete in all respect including carriage of material within all leads and lifts. Make :- Philips/LT/ Endo/Disano/Leksa as approved by Engineer-In-Charge(five year warranty)

8

2182

17456

... More
Supplying and fixing of DLP 105x50 (One hundred Five) x (Fifty) mm PVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip flexible cover end cap .Make:-Legrand ,MK or its equivalent as required complete in all respect including carriage of material within all leads and lifts. Make:- M.K /legrand as approved by Engineer-In-Charge

50

1401

70050

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 (Two point Seven) metre long etc. with charcoal/ coke and salt as required including carriage of material within all leads and lifts.

13

13858

180154

... More
Supplying and fixing true power make advanced earthing system having pure copper pipe 3 (Three) meter long 50 (Fifty) mm dia with terminal size 50x6 mm ,internal strip size 25x3 (Twenty Five x Three) mm with 50 (Fifty) Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect including carriage of material within all leads and lifts make :- True power/Earth plus/Ashloka as approved by Engineer-In-Charge

2

12995

25990

... More
Providing and fixing 4.00 (Four point zero zero) mm dia copper wire on surface or in recess for loop earthing as required including carriage of material within all leads and lifts.

350

160

56000

... More
Supplying and laying 20 (Twenty) mm x 3 (Three) mm copper strip as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 (Two) sets of brass nut bolt & spring washer spaced at 50 mm including carriage of material within all leads and lifts.

290

650

188500

... More
Supplying and laying 25 (Twenty Five) mm X 5 (Five) mm copper strip as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 (Two) sets of brass nut bolt & spring washer spaced at 50mm including carriage of material within all leads and lifts

120

1250

150000

... More
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 (Five) cm variation made from (50 (Fifty) mm x 50 (Fifty) mm x 6 (Six) mm thick) M.S. angle iron frame, covered with 1.6 mm (One point Six) thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. Removable gland plate and lugs should be provided with each cable entry and also cable support arrangement to be provided inside cable allkey so that cables are neatly arranged. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form including carriage of material within all leads and lifts:-The panel should be approved /Tested from the CPRI lab.& should confirmed to IEC-61439 (Part I &II)(Make :- Power system & control/KSB conforming to IS specifications mentioned etc)

-

-

-

... More
300 (Three hundred) Deep

18

27837

501066

... More
450 (Four hundred fifty) Deep

15

33720

505800

... More
750 (Seven hundred fifty) Deep

28

51350

1437800

... More
Supplying and fixing 4 (Four) pole MCCB Enclosure with all accessories including connections, 250 (Two hundred fifty)/DN1. as required Make:- L&T/ Legrand/Hager/ABB as approved by Engineer-In-Charge including carriage of material within all leads and lifts (five year warranty)

1

2189

2189

... More
Supplying and fixing of MCCB Four pole following rating and breaking capacity with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge including carriage of material within all leads and lifts (five year warranty)

-

-

-

... More
125 (One hundred twenty five) amp 25 (Twenty five) KA

5

6868

34340

... More
160 (One hundred sixty) amp 25 (Twenty five) KA

3

9490

28470

... More
250 (Two hundred fifty) amp 36 (Thirty six) KA

3

15485

46455

... More
Supplying and fixing of MCCB triple pole following rating and breaking capacity with thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge including carriage of material within all leads and lifts (five year warranty)

-

-

-

... More
63 - 100 (Sixty three-One hundred) Amp-18 (Eighteen) KA

28

4365

122220

... More
Providing and fixing 125 (One hundred twenty five) amp , FP Auto Transfer switch. The ATS shall be provided with Silver alloy main contacts which shall be resistant to welding and sticking including connections , testing, commissioning etc. as required including carriage of material within all leads and lifts Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

68478

68478

... More
Providing and fixing Multi Function Meter with 3 (Three) Nos. Cast Resin CTs and MCBs including V, A ,F ,P.F, KW, KVA, RUN HOUR,KWH,(EV AND DG), OLD ENERGY, SELECTATBLE KWH-KVH parameters connections , testing, commissioning etc. as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

11

4811

52921

... More
Supplying and fixing breaker on off 2 (Two) nos indication lamps for each incomer in the existing pannel complete etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

11

612

6732

... More
Providing and fixing earth fault module including single phasing, phase unbalance , earth fault & selectable triping class type connections, testing, commissioning etc. as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

9

4764

42876

... More
Supplying and fixing 2 (Two) Nos. Supply available indication lamp in the existing pannel complete etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

2

612

1224

... More
S/F indicator set RY &B with 3 (Three) Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

35

500

17500

... More
Supplying and fixing MCB TPN of following rating and breaking capacity, 240/415 volts, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

-

-

-

... More
63 (Sixty three) amp ,15 (Fifteen) KA

51

10010

510510

... More
40 (Forty) amp, 10 (Ten) KA

31

2442

75702

... More
25 (Twenty five) amp, 10 (Ten) KA

25

1740

43500

... More
Supplying and erection of 25 (Twenty five) amps rating, 10 (Ten) KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of double poles in the existing MCB DB complete with connections etc. as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

13

829

10777

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 10 ka , 440 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer -In-Charge (five year warranty)

-

-

-

... More
40 (Forty) AMP

5

3872

19360

... More
63 (Sixty three) AMP

5

4185

20925

... More
Supplying and fixing of MCCB four pole following rating and breaking capacity with thermal magnet in release complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

-

-

-

... More
32 - 63 (Thirty two - Sixty three) Amp-18 (Eighteen) KA

4

5436

21744

... More
100 - 125 (One hundred - One hundred twenty five) Amp-25 (Twenty Five) KA

8

6868

54944

... More
Supplying and fixing copper strip bus-bars suitable for 100 (One hundred) Amp. 415 volts capacity 4 (Four) No. each of cross-sectional area (25mmx3mm),in the existing enclosure with all accessories including connections etc. as required including carriage of material within all leads and lifts.

7

9423

65961

... More
Supplying and fixing copper strip bus-bars suitable for 200 (Two hundred) Amp. 415 volts capacity 4 (Four) No. each of cross-sectional area (25mmx5mm),in the existing enclosure with all accessories including connections etc. as required including carriage of material within all leads and lifts.-

6

14718

88308

... More
Supplying and fixing copper strip bus-bars suitable for 300 (Three hundred) Amp. 415 volts capacity 4 (Four) No. each of cross-sectional area (40mmx5mm),in the existing enclosure with all accessories including connections etc. as required including carriage of material within all leads and lifts.

6

22072

132432

... More
Supplying and fixing of ammeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 (One point zero ; Zero point five) complete with connection ;testing and commissioning etc Make:- L&T/Legrand/Hager/ABB as approved by Engineer-In-Charge (five year warranty)

1

1485

1485

... More
Supplying and fixing of voltmeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 (One point zero ; Zero point five) complete with connection ;testing and commissioning etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

1485

1485

... More
Providing and fixing of Rubber Mat 1x2 (One x Two) mtrs long 12 (Twelve)mm thick in the front main panel etc as required at site. including carriage of material within all leads and lifts.

8

2400

19200

... More
Supplying and fixing Shock treatment chart in main panel room on the existing wall etc as required and as approved by Engineer-in-charge including carriage of material within all leads and lifts.

8

150

1200

... More
Supplying and fixing of Segregated tripple pole and neutral of following ways surface/ recess mounting, 7 (Seven) Segment 415volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, with provision to mount FP MCB incomer, DP MCB/RCCB sub-incomer in each phase and SP MCBs as outgoing (but without MCB ’s and incomer), complete with tinned copper din-bar, wire-set, neutral link, earth bar, detachable gland plate, cable interconnections, including earthing etc. as required including carriage of material within all leads and lifts. Make :- L&T/Hager/ABB/ Legrand as approved by Engineer-in -charge.(five year warranty)

-

-

-

... More
6 (Six) way Double Door

2

12541

25082

... More
8 (Eight) way Double Door

19

13958

265202

... More
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar, detachable gland plate, interconnections, with appropriate rating copper lugs, gland , powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

-

-

-

... More
MCBDB 4 (Four) WAY Double Door

26

1922

49972

... More
MCBDB 8 (Eight) WAY Double Door

6

2275

13650

... More
MCBDB 12 (Twelve) WAY Double Door

13

2683

34879

... More
Supplying and fixing 5 (Five) amps to 32 (Thirty two) amps , 240/415 volts, 10(Ten) kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

-

-

-

... More
single pole

698

293

204514

... More
Supplying and erection of 40/50/63 (Forty/Fifty/Sixty Three) amps rating, 10 (Ten) KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of double poles in the existing MCB DB complete with connections etc. as required including carriage of material within all leads and lifts.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

99

1306

129294

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

-

-

-

... More
40 (Forty) AMP

52

3170

164840

... More
63 (Sixty three) AMP

37

3927

145299

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5 (Seventeen point Five) %, in convenient sections, joined withconnectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
225 mm width X 50 mm depth X 1.6 (One point six) mm thickness

120

1050

126000

... More
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required including carriage of material within all leads and lifts.Make:-KEI/POLYCAB/ Havells /Finolex as approved by Engineer-in-charge

-

-

-

... More
25 (Twenty five) sqmm (3.5core) (Three point five core)

205

426

87330

... More
35 (Thirty five) sqmm (3.5core) (Three point five core)

380

529

201020

... More
50 (Fifty) sqmm (3.5core) (Three point five core)

210

769

161490

... More
70 (Seventy) sqmm (3.5core) (Three point Five core)

150

1002

150300

... More
95 (Ninety Five) sqmm (3.5core) (Three point five core)

170

1225

208250

... More
120 (One hundred twenty) sqmm (3.5core) (Three point five core)

340

1509

513060

... More
150 (One hundred fifty) sqmm (3.5core) (Three point five core)

365

1770

646050

... More
240 (Two hundred forty) sqmm (3.5core) (Three point five core)

210

2827

593670

... More
300 (Three hundred) sqmm (3.5core) (Three point five core)

200

3439

687800

... More
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering including carriage of material within all leads and lifts..Make:-KEI/POLYCAB/ Havells/,Finolex as approved by Engineer-in-charge

-

-

-

... More
300 (Three hundred) sqmm (3.5core) (Three point five core)

240

3390

813600

... More
Providing and fixing hand dryer flash touch free infrared with 1150 (One Thousand one hundred fifty) watts rated power carbon brush motor finish with 304 stainless steel complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects including carriage of material within all leads and lifts. Make: Jaquar/Philips /Havells as approved by Engineer-in-charge(five year warranty)

8

9705

77640

... More
Supplying and erection of Decorative pole of galvanised mild steel pipes fitted with cast aluminium ,steel embellishments duly polyurethane paint coated 9 (Nine) Meter with single arm bracket 1.5 (One point five) mtr suitable for installation of 2 (Two)nos LED flood light and pole having nominal dia. 130 mm bottom A/F and nominal dia. 70 mm top A/F made up of 3.0 (Three point Zero) mm thickness HR sheet a/w base plate of size 220x220x12 mm thickness,The pole has a service window at the bottom profile comprising 4-way 25 Amp connector terminal and 3 nos MCB 10 amp to control individual flood light etc as req. The pole to be mounted on a 1:3:6 cement concrete base (pedestal) of 450X450 mm and 300 mm including 4 Nos M 20X700 MM J-Type EN 8 grade foundation bolts with nuts, templates and i/c with suitable bracket of suitable size as per site as required. Foundation RCC 1:2:4 shall be of size 450x450mm and depth 900 mm c/c ,connection,testing and commissioning as required complete in all respects. Make:- Mayfair (mfmd-109)/Wipro/BAJAJ/Twinkle/Volmount as per best satisfaction on Engineer-in -charge .

8

33728

269824

... More
MAIN LT CUM DG SYNCHRONIZATION PANEL (50 kA)

-

-

-

... More
1250 KVA TRANSFORMER INCOMER

-

-

-

... More
Supplying ,Installation, testing and commissioning 4 (Four) pole EDO Type ACB 2000 (Two thousand) AMP , breaking capacity 50 (Fifty) kA withmicroprocessor release unit inbuilt short circuit,over current and earth fault protection with adjustable setting as per specifications, & comprising of 3 Nos. Cast resin CTs Of ratio 2000 / 5 Amps CL:1 ( For Metering) , R-Y-B indication Lamp , Trip Circuit Healty and Breaker ON-OFF - Trip Indication Lamp ,Over Voltage relay (59) And Under Voltage relay (27) with time delay , Multi Function meter having 30 Days Memory ,Digital voltmeter with inbuilt selector switch- 1 set,Trip Circuit Supervision Relay,Master Trip Relay,Shunt trip coil. - 1 Set,Under voltage release. - 1 Set,2000/5A CT for APFCR,Surge protection device,Breaker control switch (TNC),Auxiliary contacts required for necessary interlocking of breakers.( 6 No + 6 NC ),Annunciation with test and reset for fault indication, 5P20( For protection) , 15 VA. , 5P20( For protection) , 15 VA.5 kVAR fixed capacitor with MCCB,confirm to IS/IEC 60947-2 and IEC 60947-2 etc. complete with connection ,testing and commissioning etc as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

474102

474102

... More
750 (Seven hundred fifty) KVA DG #1 INCOMER

-

-

-

... More
Supplying ,Installation, testing and commissioning 4 (Four) pole EDO Type ACB 1250 (One thousand two hundred fifty) AMP , breaking capacity 50 (Fifty) KA with inbuilt short circuit,over current and earth fault protection with adjustable setting as per specifications, & comprising of Controller for parallel genset operation (similar to InteliGen 200 of CompAp or equal) 3, Nos. Cast resin CTs Of ratio 1250 / 5 Amps CL:1 ( For Metering),5P20( for protection ) 15 VA , R-Y-B indication Lamp Trip Circuit Healty and Breaker ON-OFF - Trip Indication Lamp , ,Over Voltage relay (59) And Under Voltage relay (27) with time delay, , 1 no reverse power relay,Underpower Relay with Timer - 1 Set, Phase Sequence Relay - 1 Set, Multi Function meter having 30 Days Memory , Trip Circuit Supervision Relay ,Master Trip Relay,Shunt trip coil 1 set , 240 V AC under voltage release. - 1 Set, Surge protection device,Breaker control switch (TNC),Auxiliary contacts required for necessary interlocking of breakers.( 6 No + 6 NC ),Annunciation with test and reset for fault indication,Engine cranking relay- 1 Set , Microprocessor based engine control automatic failure stand by relay including all accessories, Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start’,One 16 amp automatic Battery charger with inbuilt facility of trickle / boost & consisting of , (1) DC Ammeter (0-30) Amp.(2)DC Voltmeter.(0-30) Volt.(3)Charger ON, OFF indications ,DG start / Stop push buttons (Illuminated Type), Emergency Stop Push Button,confirm to IS/IEC 60947-2 and IEC 60947-2 complete with connection ,testing and commissioning etc as required.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

510964

510964

... More
500 (Five hundred) KVA DG #2 INCOMER

-

-

-

... More
Supplying ,Installation, testing and commissioning 4 (Four) pole EDO Type ACB 800 (Eight hundred) AMP , breaking capacity 50 (Fifty) KA with inbuilt short circuit,over current and earth fault protection with adjustable setting as per specifications, & comprising of Controller for parallel genset operation (similar to InteliGen 200 of CompAp or equal) 3, Nos. Cast resin CTs Of ratio 1250 / 5 Amps CL:1 ( For Metering),5P20( for protection ) 15 VA , R-Y-B indication Lamp Trip Circuit Healty and Breaker ON-OFF - Trip Indication Lamp , ,Over Voltage relay (59) And Under Voltage relay (27) with time delay, , 1 no reverse power relay,Underpower Relay with Timer - 1 Set, Phase Sequence Relay - 1 Set, Multi Function meter having 30 Days Memory , Trip Circuit Supervision Relay ,Master Trip Relay,Shunt trip coil 1 set , 240 V AC under voltage release. - 1 Set, Surge protection device,Breaker control switch (TNC),Auxiliary contacts required for necessary interlocking of breakers.( 6 No + 6 NC ),Annunciation with test and reset for fault indication,Engine cranking relay- 1 Set , Microprocessor based engine control automatic failure stand by relay including all accessories, Three indicating lamps “load on set’, ‘Load on Mains’ and “ Set fail to start’,One 16 amp automatic Battery charger with inbuilt facility of trickle / boost & consisting of , (1) DC Ammeter (0-30) Amp.(2)DC Voltmeter.(0-30) Volt.(3)Charger ON, OFF indications ,DG start / Stop push buttons (Illuminated Type), Emergency Stop Push Button,confirm to IS/IEC 60947-2 and IEC 60947-2as required, complete in all rspect including carriage of material within all leads and lifts. Make:- L&T / Legrand/ Hager/ ABB as approved by Engineer-in -charge.

1

400415

400415

... More
BUS COUPLER

-

-

-

... More
Supplying ,Installation, testing and commissioning Bus coupler 4 (Four) pole EDO TYPE ACB 1000 (One thousand) AMP , breaking capacity 50 (Fifty) kA without release comprising of 6 nos NO/NC contacts for remote opening 7 closing , red/ green/amber /on/off/ trip indicating lamps with 2 A SP MCB as backup protection , Backup mcb and terminal blocks as required., TNC Breaker control switch , Required interlocking with other incomers & bus coupler to be provided as per schmatic diagram as complete required. confirm to IS/IEC 60947-2 and IEC 60947-2 electrically operated draw outversion, high short time fault with standing capacity Icu=Ics-low for 1 second for total selectivity, High mechnical and elecrtrical operting life protected through micro processor releases (SR18G, SR18G+D, SR 18GI+D and SR 71) with on load test button inbuildt thermal memory, protection releases confirm to EMI/EMC standards, data communication and power management, breaker status and control thourgh MODBUS protocol (UN-CO module) including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ABB as approved by Engineer-In-Charge (five year warranty)

1

307750

307750

... More
solar incomer

-

-

-

... More
Providing and fixing 4 (Four) pole 200 (Two hundred) amp and 25 (Twenty five) ka breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicAL panel board including drilling holes in cubicle panel, making connections, etc. as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

24097

24097

... More
Supplying and fixing aluminium strip bus-bars suitable for 2400 (Two thousand four hundred) Amp. 415 volts capacity 4 (Four) No. each of cross-sectional area (200X12 mm ) having high conductivity electrical grade suitable to withstand symmetrical fault level of 50 (Fifty) KA. Neutral busbar shall be of 100% capacity. ,in the existing enclosure with all accessories including connections etc. as required including carriage of material within all leads and lifts.

20

15437

308740

... More
Supplying and fixing aluminium strip bus-bars suitable for 1200 (One Thousand Two hundred) Amp. 415 volts capacity 4 (Four) Nos each of cross-sectional area (200X6 mm ) having high conductivity electrical grade suitable to withstand symmetrical fault level of 50 (Fifty) KA. Neutral busbar shall be of 100% capacity. ,in the existing enclosure with all accessories including connections etc. as required including carriage of material within all leads and lifts.

12

6842

82104

... More
Outgoing section I & II

-

-

-

... More
Supplying ,Installation, testing and commissioning 4 (Four) pole ACB 1000 (One Thousand) AMP , breaking capacity 50 (Fifty) KA confirm to IS/IEC 60947-2 and IEC 60947-2 manually operated draw outversion, high short time fault with standing capacity Icu=Ics-low for 1 second for total selectivity, High mechnical and elecrtrical operting life protected through micro processor releases (SR18G, SR18G+D, SR 18GI+D and SR 71) with on load test button inbuildt thermal memory, protection releases confirm to EMI/EMC standards, data communication and power management, breaker status and control thourgh MODBUS protocol (UN-CO module) etc. complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

2

229193

458386

... More
Supplying ,Installation, testing and commissioning 3 (Three) pole MCCB 630 (Six hundred thirty) AMP Amp Ics = 100% icu, 50 (Fifty) KA & @ 415 volts, 50 Hz with Microprocessor release Mtx2.0 (Two point Zero) & ITRP3 conforms to IS/IEC 60947-2 complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hage/, ABB as approved by Engineer-In-Charge (five year warranty)

1

45110

45110

... More
Supplying ,Installation, testing and commissioning 3 (Three) pole MCCB 400 (Four hundred) AMP Amp Ics = 100% icu, 36 (Thirty six) KA & @ 415 volts, 50 Hz with Microprocessor release Mtx2.0 (Two point Zero) & ITRP3 conforms to IS/IEC 60947-2 complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts. Make:- L&T/Legrand/ Hager/ABB as approved by Engineer-In-Charge (five year warranty)

3

37619

112857

... More
Supplying ,Installation, testing and commissioning 3 (Three) pole 250 (Two hundred Fifty) amp and 36 (Thirty Six) ka breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicAL panel board including drilling holes in cubicle panel, making connections, etc. as required.Make:- L&T/ Legrand/ Hager/ ABB as approved by Er-In-Charge (five year warranty)

5

24353

121765

... More
Supplying ,Installation, testing and commissioning 3 (Three) pole 160 (One hundred sixty) amp and 25 (Twenty five) ka breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicAL panel board including drilling holes in cubicle panel, making connections, etc. as required.Make:- L&T/ Legrand/ Hager/ ABB or its equivalent as approved by Engineer-in -charge.

5

13881

69405

... More
Supplying ,Installation, testing and commissioning 3 (Three) pole 125 (One hundred twenty five) amp and 25 (Twenty five) ka breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicAL panel board including drilling holes in cubicle panel, making connections, etc. as required.Make:- L&T/ Legrand/ Hager/ ABB or its equivalent as approved by Engineer-in -charge.

6

11327

67962

... More
Supplying ,Installation, testing and commissioning PLC with HMI 7 (Seven) inch ,all incoming and outgoing breakers shall be electrically/ mechanically interlocked through a Load Sharing cum Synchronization PLC comprising suitable nos. digital inputs (24 (Twenty four) VDC) and output (Relay) for auto operation of DGs as per load requirement 1 KVA UPS with 30 mon back50kA fault level continuous Earth Bus shall be part of Panel for full length of panel Colour coding for DG Incomer ,Transformer Incomer & Bus coupler shall be done 1 set of 32 amp 4P MCB with wiring upto compartment of D.C.U.'s along with 1 mm sq wire for all RS-485 communication port of KWH meter to D.C.U.'s compartment. .etc complete with connection ,testing and commissioning etc as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

77129

77129

... More
450 (Four hundred fifty) KVAR CAPACITOR PANEL

-

-

-

... More
Supplying and fixing Microprocessor based 16 (Sixteen) Step APFC controller shall continuously monitor all three phases and displays various Electrical Parameters like voltage, input current, capacitive current, KVA demand, KW, Power Factor, self diagnostic error code indication with printout facility of the above with RS 232C port. It shall have data logging for minimum 2 months, it shall provide output for minimum 14 stages.etc as complete in all respect including carriage of material within all leads and lifts..Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

22677

22677

... More
Capacitor Bank as per following: (All MCCBs ( 35 (Thirty five) kA) shall be thermal Magnetic type )

-

-

-

... More
100 (One hundred) KVAR UNIT

-

-

-

... More
Supplying and fixingof 100 (One hundred) KVAR Capacitor Bank comprising of 250 (Two hundred Fifty) amps TP MCCB, 36 (Thirty Six) ka heavy duty solid detachable neutral link,.100 kVAR capacitor duty 415 volts 50 Hz contactors,"ON" / "OFF" push buttons and indicating lamps.250 amps rating TP terminal blocks.100 KVAR mixed dielectric extra low loss type capacitor unit.,,Auto Manual Selector Switchetc as complete in all respect including carriage of material within all leads and lifts..Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

1

99476

99476

... More
50 (Fifty) KVAR UNIT

-

-

-

... More
Supplying and fixingof 50 (Fifty) KVAR Capacitor Bank comprising of 125 (One hundred twenty five) amps TP MCCB,36 (Thirty Six) ka heavy duty solid detachable neutral link,.50 (Fifty) kVAR capacitor duty 415 volts 50 Hz contactors,"ON" / "OFF" push buttons and indicating lamps.50 (Fifty) amps rating TP terminal blocks.50 KVAR mixed dielectric extra low loss type capacitor unit.,,Auto Manual Selector Switchetc complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

5

90452

452260

... More
25 (Twenty five) KVAR UNIT

-

-

-

... More
Supplying and fixingof 25 (Twenty five) KVAR Capacitor Bank comprising of 63 (Sixty three) amps TP MCCB, 36 (Thirty six) ka heavy duty solid detachable neutral link,.25 kVAR capacitor duty 415 volts 50 Hz contactors,"ON" / "OFF" push buttons and indicating lamps. 63 (Sixty three) amps rating TP terminal blocks.25 KVAR mixed dielectric extra low loss type capacitor unit.,Auto Manual Selector Switchetc complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

2

33464

66928

... More
15 (Fifteen) KVAR UNIT

-

-

-

... More
Supplying and fixingof 15 (Fifteen) KVAR Capacitor Bank comprising of 40 (Forty) amps TP MCCB ,36 ka heavy duty solid detachable neutral link,.15 kVAR capacitor duty 415 volts 50 Hz contactors,"ON" / "OFF" push buttons and indicating lamps.40 (Forty) amps rating TP terminal blocks.15 KVAR mixed dielectric extra low loss type capacitor unit.,Auto Manual Selector Switchetc complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts. Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

2

30910

61820

... More
10 (Ten) KVAR UNIT

-

-

-

... More
Supplying and fixingof 10 (Ten) KVAR Capacitor Bank comprising of 32 (Thirty two) amps TP MCCB ,36 (Thirty six) ka heavy duty solid detachable neutral link,.10 kVAR capacitor duty 415 volts 50 Hz contactors,"ON" / "OFF" push buttons and indicating lamps. 40 (Forty) amps rating TP terminal blocks.10 KVAR mixed dielectric extra low loss type capacitor unit.,Auto Manual Selector Switchetc complete with connection ,testing and commissioning etc as required including carriage of material within all leads and lifts.Make:- L&T/ Legrand/ Hager/ ABB as approved by Engineer-In-Charge (five year warranty)

2

26355

52710

... More
Providing and fixing of lightning conductor finial, made of 20 (Twenty) mm outer dia. 1.2 (One point Two) mtr long copper tube, having single prong at top, with 85 mm dia 3 (Three) mm thick copper base plate including holes etc. complete as required including carriage of material within all leads and lifts. Make:- True power /Earth plus/ Ashloka or as approved by Engineer-in -charge.

3

1862

5586



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.