Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Ministry Of Power

  • Opening Date

    07 Oct 2019

  • Closing Date

    17 Oct 2019

  • Tender Amount

    Refer document

  • EMD

    -

Are you Looking for Joint Venture Partners, Contractor Consortium, Project Financiers for this tender?
We will help YOU to find the right match for FREE!
Summary

Led Luminaire (for Flood Light),led Luminaire (for Road And Street Lights)

Are you looking for Materials and Services for this tender?
We will help YOU to find the right partner for your needs for FREE!
BOQ Items

No BOQs Available

Bid Number: GEM/2019/B/379809 Dated: 07-10-2019 Bid Document Bid Details Bid End Date/Time 17-10-2019 14:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 60 (Days) Ministry/State Name Ministry Of Power Department Name Na Organisation Name N/a Office Name Parbari Stage-ii Nhpc Limited Total Quantity 200 Item Category LED Luminaire (for Flood Light) , LED Luminaire (For Road and Street Lights) MSE Exemption For Years Of Experience And Turnover Yes Startup Exemption For Years Of Experience And Turnover Yes Document required from seller OEM Authorization Certificate Bid to RA enabled No LED Luminaire (for Flood Light) ( 10 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * 1 / 13 Types of LED Luminaire as per the IS: 16107(Part-2/ Sec.-1)/2012 Type B * Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 * LED Rating/System Wattage/Rated Power 200W 200W Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 IP66 Mounting brackets (included) Adjustable * Warranty for free replacement (in Years) 4 5, 3, 4 ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V * Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) ≥85 * Total Harmonics Distortion (in %age) ≤ 10 * "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes * OPTICAL LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K * Working life for LED (Minimum 50,000 burning hours as per LM-80 report) Yes * Colour Rendering Index(CRI) ≥70 * 2 / 13 Beam Angle ≥120 * Optic lense materal (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense * THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Junction temperature < 85 degC * Operating temperature range -10 deg C to +50 deg C * Operating Humidity Range 10 % to 95% RH * PROTECTION Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV * The luminaire shall be protected against surges and transients of >/=10KV (External) Yes * CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant epoxy powder Yes * 3 / 13 coated All fastners must be of stainless steel Yes * The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes * Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust, water, insects etc., Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.