Military Engineer Services Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date5 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687094_1Tender No
CWE/Y-96/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
384.78
-
-
... More
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in coping of pole including necessary form work complete all as specified and directed.
1.14
-
-
... More
PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
10.44
-
-
... More
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
261.95
-
-
... More
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick including taking out old bricks, complete all as specified and directed.
25000
-
-
... More
Laying only bricks along the length of cable on sand cushioning, with width equal to the length of the brick , complete all as specified and directed.
3122
-
-
... More
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
40
-
-
... More
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 50mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
60
-
-
... More
Dismantling poles/struts, any size and type including insulators and removing from site, complete all as specified.
12
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 300 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
120
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 240 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
200
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 185 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
100
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 150 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
100
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 120 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
200
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 95 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
400
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 70 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
500
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 50 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
600
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 35 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
600
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 25 sqmm 4 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
700
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 16 sqmm 4 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
600
-
-
... More
Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 16 sqmm 2 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988 including taking out existing unserviceable cable, complete all as specified and as directed.
500
-
-
... More
Cable route indicator made out of 2 mm thick mild steel sheet of size 20 cms X 15 cms duly coated with two coats of black paint over a coat of red oxide primer duly written the size of LT/ HT cable in white paint and welded to equal angle of size 30X30X3mm, 45 cms long and errected in ground in such a way that it is 15 cms above ground level and 30 cms below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate of size 15 cms X 20 cms X 45 cms all as specified & directed. Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor.
75
-
-
... More
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm
size, complete all as specified.
30
-
-
... More
Replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, Size of conductor 10 Sqmm, complete all as specified
800
-
-
... More
Replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, Size of conductor 16 Sqmm, complete all as specified
800
-
-
... More
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ.
12
-
-
... More
Galvanized steel wire 4mm dia for earth wire/ guard wire on HT/ LT poles stretched without kinks, bend and binding with wire including fabrication of cradles hexagonal/ rectangular guards, spacers, road crossing etc., including taking down old wire of any type shape , size and removing from site, complete all as specified & directed .
50
-
-
... More
Supply , fixing and straining of Aluminum conductor steel reinforced (ACSR) of any size on HT/LT over head line including necessary binding work, jumpering, maintaining proper sag as per IE rule including cutting of tree branches around the ACSR conductor within area of 5mtr complete including taking down conductor all as specified & directed
2.8
-
-
... More
Supply, installation, commissioning and testing bus chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15 mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement with IP-54 protection as per IS-8623, duly powder coated (Internally and externally) for 415 volts, 3 phase, 4 wire having TPN aluminium bus bars of 200 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glands including one No MCCB with adjustable thermal and fixed magnetic release of capcity of 125 amps, 415 volt, 25 KA, 4 pole ,fixed in PCC M-15, type B-0, using 12.5 mm graded crushed stone aggregate including taking down old unservicable chamber all as specified.
14
-
-
... More
Galvanised stay strand, 7/3.15mm, including taking down unserviceable stay wire all as specified.
0.31
-
-
... More
Re-stretching of ACSR conductor and earth wire of any size and type on HT poles including disconnecting and rewinding with insulators with suitable size of binding wire after restretching, connecting jumpers adjusting line dividers etc and cutting/trimming of tree branches upto 2 mtr clear distance from wire all as directed by Engr-in-Charge.
295
-
-
... More
Cutting/ trimming of tree branches after taking shut down from power house, 1,00 metre apart from HT/LT line of both sides of conductor including removing branches from site, complete all as specified & directed. Note:- (i) Clearing branches from both sides of conductor in between two consequtive poles shall be considered as one span irrespective of distance between poles. (ii) Cost of T&P required for cutting and removing branches shall be deemed to be included in rate quoted by bidder.
500
-
-
... More
Stay Assembly using stay rod of 20mm dia complete with accessories as shown in Electrical Plate No. 1 of SSR 2009 Part-I including galvanized steel stranded wire of size 7/4mm and taking out/ dismantling old stay assembly, complete all as specified (Loop type insulator, earth work and PCC shall be measured and paid for separately under respective items of BOQ)
6
-
-
... More
Loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 90x140mm, clearance of hole 25.5 mm, complete all as specified and directed.
6
-
-
... More
Shackle Type, Polymer, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, working pressure 1100 volts, 75mm height, 90mm, galvanised mild steel strap 31x3mm, dia of bolt 12mm, including taking down old insulator complete all as specified and directed.
40
-
-
... More
Pin type, polymer, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade including taking down old insulator complete all as specified and directed.
40
-
-
... More
PVC seperator suitable for four ACSR Conductor feeder, complete all as specified.
120
-
-
... More
Replacement of voltmeter for LT panel Square dial of size 96x96mm digital type , flush mounted , three phase class 0.5 complete all as specified and as directed.
20
-
-
... More
Replacement of Amp meter for LT panel , digital type , flush mounted , three phase class 0.5 complete all as specified and as directed.
20
-
-
... More
Replacement of indicator lamp assembly in red,yellow & blue colour for LT panels complete all as specified and as directed.
20
-
-
... More
Replacement of Selector switch , flush mounted , three phase class 0.5 complete all as specified and as directed.
20
-
-
... More
Painting to existing steel tubular poles 09m long including cross arms, clamps etc. with two coats of aluminum paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC copping including preparation of old painted surfaces by scraping complete all as specified.
150
-
-
... More
Painting to existing Prestressed concrete poles, 8.5m long with two coats of cement base paint including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
55
-
-
... More
Replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 630 Amps , Breaking Capacity 50 KA, MCCBs, Adjustable Thermal & Adjustable Magnetic settings, Rated Service short circuit Breaking Capacity Ics =100%, 415 Volts including suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.
Note- Rate of extended terminal deemed to be included in this item.
2
-
-
... More
Replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 400Amps, Breaking Capacity 36 KA, MCCBs, Adjustable Thermal & Adjustable Magnetic settings, Rated Service short circuit Breaking Capacity Ics =100%, 415 Volts including suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.
Note- Rate of extended terminal deemed to be included in this item.
4
-
-
... More
Replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 250 Amps , Breaking Capacity 36 KA, MCCBs, Adjustable Thermal & Fixed Magnetic settings, Rated Service short circuit Breaking Capacity Ics =100%, 415 Volts including suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.
Note- Rate of extended terminal deemed to be included in this item.
10
-
-
... More
Replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 200Amps, Breaking Capacity 36 KA, MCCBs, Adjustable Thermal & Adjustable Magnetic settings, Rated Service short circuit Breaking Capacity
Ics =100%, 415 Volts including suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.
Note- Rate of extended terminal deemed to be included in this item.
8
-
-
... More
Replacement of existing unserviceable MCCB any size/capacity with MCCB 3 pole 25 to 100Amps, Breaking Capacity 16 KA, MCCBs, Fixed Thermal & Fixed Magnetic settings, Rated Service short circuit Breaking Capacity Ics =75%, 415 Volts including suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.
Note- Rate of extended terminal deemed to be included in this item.
10
-
-
... More
Cleaning of area around/inside/outside installation by removing the vegetation, cleaning of fungus formation and nearby growth of wild vegetation, bushes and removal of waste upto a distance of 50 metre , complete all as specified.
1500
-
-
... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
22
-
-
... More
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25mm x 4mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
26
-
-
... More
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 24 of tender doucments.
-
-
-272345
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%