Jal Shakti Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Jal Shakti Department - HPIPH Tender

Works
Civil And Construction
Excavation
Eprocure
Opening Date1 Apr 2022
Closing Date12 Apr 2022
Tender Amount₹ 17,02,107 
Notes
Download

Costs

Summary

Providing Cad Lis Dhandri And Lis Saloi In Distt. Una (hp)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
ii)Drilling and lowering of M.S casing pipes confirming to IS 4270-2001 with up-to-date ammendments,if any, of suitable sizes as mentioned above,from 30-60 mtrs below ground level within all leads and lifts.

30

-

-

... More
iii)Drilling and lowering of M.S casing pipes confirming to IS 4270-2001 with up-to-date ammendments,if any, of suitable sizes as mentioned above,from 60-90 mtrs below ground level within all leads and lifts.

30

-

-

... More
iv)Drilling and lowering of M.S casing pipes confirming to IS 4270-2001 with up-to-date ammendments,if any, of suitable sizes as mentioned above,from 90-125 mtrs below ground level within all leads and lifts.

35

-

-

... More
Collection, preservaion and display of suitable size sample box with top lid and locking arrangement till handing over of the tube well to the department complete in all respects as per direction of the Engineer -in-Charge.

1

-

-

... More
a)Supply and lowering of IS marked Electric Resistance Welded M.S. pipe 300 mm dia nominal size housing, 8 mm thick having out side dia mtrs. 323.90 mm bevelled edge confirming to I.S. 4270-2001 with up-todate amendments, if any ,about 4 mtrs to 7 mtrs in length, welded without any circumferential joints, into bore hole in vertical position including cost of all scaffolding derricks, poles, clamps embedded in foundation etc. including cost of all cutting, threading and welding of pipes etc. within all leads and lifts,complete in all respects as per the directions of the Engineer -in-Charge.

55

-

-

... More
b)Supplying and Lowering at site Electric Resistance Welded ( ERW) Stainless Steel Cage type "V" wire wound screens of size 300 mm , 8 mm thick with slot opening 1.0 mm,as per IS 8110-2000 with upto date ammendments,if any, and material specification as per AISI" American Iron and Steel Inst " Type Grade SS-304 in suitable lenghts as per site conditions, including the cost of SS socket 8mm thickness(supplied by the department ) of length 140 mm, confirming to AISI grade 304, suitable to accomodate screen and ring including jointing screen with blind pipes complete in all respects all scaffolding derricks, poles, clamps, embedding in foundation etc. including cost of all cutting, threading and welding of pipes etc. within all leads and lifts complete in all respects as per the directions of the Engineer - in - Charge. Screen will be of continuous trapezoidal wire spirally wound around fabricated cage. The wrapping wire having "V" shaped ( Wedge) profile wire with flat surface on the outside and producing expanding slots on the inside of various dimensions, resistance welded to a cylindrical body made of number of longitudinal special high tensile support rods to provides smooth unrestricted bore which are in turn welded into cylindrical ring couplings on both sides of screens.

1

-

-

... More
Providing and Lowering of IS marked Electric Resistance Welded (ERW) M.S slotted pipe 300 mm dia nominal size housing 8.00 mm thick having outside dia meter 219.10 mm screwed and socketted confirming to IS 4270-2001 (App.1020 slattes)/Mtrs. Slat size 1.57x1.57 mm welded circumfrential joints into bore hole in vertical position including cost of all scaffolding derricks poles,clamps embedded in foundation etc.including cost of all cutting,threading and welding of piece etc.within all leads and lifts complete in all respects as per the direction of the Engineer-in-charge.

4

-

-

... More
Providing and fixing M.S. taper / reducer as per lengths approved by Engineer -in-Charge ,the material of M.S taper/reducer shall be equivalent to parent pipe material and shall conform to chemical composition as per 4270-2001 with upto date ammendments ,if any, complete in all respect as per directions of the Engineer -in -Charge.

1

-

-

... More
a)Supply and lowering of IS marked Electric Resistance Welded M.S.pipe 200 mm nominal size housing, 6.40 mm thick having out side dia mtrs. 219.10 mm bevelled edge confirming to I.S. 4270-2001 with up-todate ammendments, if any ,about 4 mtrs to 7 mtrs in length, welded without any circumferential joints, into bore hole in vertical position including cost of all scaffolding derricks,poles,clamps embedded in foundation etc. including cost of all cutting,threading and welding of pipes etc. within all leads & lifts, complete in all respects as per the directions of the Engineer -in-Charge.

55

-

-

... More
b)Supplying and lowering at site Electric Resistance Welded (ERW) Stainless Steel Cage type "V" wire wound screens of size 200 mm ,6.30 mm thick with slot opening 1.0 mm,as per IS 8110-2000 with upto date amendments,if any, and material specification as per AISI"American Iron and Steel Inst" Type Grade SS-304 in suitable lenghts as per site conditions, including the cost of SS socket 8 mm thickness ( supplied by the department) of length 140 mm, confirming to AISI grade 304, suitable to accomodate screen and ring including jointing screen with blind pipes complete in all respects all scaffolding derricks,poles, clamps, embedding in foundation etc. including cost of all cutting, threading and welding of pipes etc. within all leads and lifts complete in all respects as per the directions of the Engineer - in - Charge.Screen will be of continuous trapezoidal wire spirally wound around fabricated cage.The wrapping wire having "V" shaped (Wedge) profile wire with flat surface on the outside and producing expanding slots on the inside of various dimensions, resistance welded to a cylindrical body made of number of longitudinal special high tensile support rods to provides smooth unrestricted bore which are in turn welded into cylindrical ring couplings on both sides of screens.

1

-

-

... More
Providing and Lowering of IS marked Electric Resistance Welded (ERW) M.S slotted pipe 200 mm dia nominal size housing 6.40 mm thick having outside dia meter 219.10 mm screwed and socketted confirming to IS 4270-2001 (App.1020 slattes)/Mtrs. Slat size 1.57x1.57 mm welded circumfrential joints into bore hole in vertical position including cost of all scaffolding derricks poles,clamps embedded in foundation etc.including cost of all cutting,threading and welding of piece etc.within all leads and lifts complete in all respects as per the direction of the Engineer-in-charge.

9

-

-

... More
Providing and fixing M.S centralized guides at suitable spacing for each tube well as per IS 226-1991 with up-to-date amendments if any, within all leads and lifts ,1x4Nos. completed in all respects as per the directions of the Engineer -in-Charge.

5

-

-

... More
Supplying ,lowering and fixing in position IS marked mild steel bail plug of 200 mm/ 300 mm diameters with "U" hooks as per IS 2800-1991 with up -to date amendements ,ifany, within all leads and lifts, complete in all respects per directions of the Engineer -in- Charge.

1

-

-

... More
Pdg. and fixing in position threaded iron cap with locking arrangements of approved design to prevent foreign matter from getting into bore hole,as required, within all leads and lifts, complete in all respects as per directions of the Engineer -in- Charge.

1

-

-

... More
Supplying and packing of gravel, consisting of hard quartz or other suitable material with an average specific gravity of not less than 2.5, not containing more than 2% by weight of thin flat of elangated pieces, shall be of sub rounded to rounded grains with minimum angular features of size 2-3.35 mm ,shall be free from impurities such as shafe, shale, mica, felspar, clay, sand,dirt loam,baematte and organic material as pe IS 4097-1967 with upto date amendments, if any, around intake of tubewell with minimum thickness of shroud around screen generally 100 mm to the entire depth of the bore as per 2800 (Part-I ) 1991 with upto date amendments, if any, with in all leads and lifts complete in all respects as per direction of the Engineer -in- Charge.

125

-

-

... More
Extration of all sizes blind/casing pipes with machine starting from the bottom of the bore hole,within all leads and lifte,complete in all respects as per direction of the Engineer-in-Charge as follows. (a) In contact with soil.

125

-

-

... More
(b) Free hanging.

165

-

-

... More
Development of tubewell by back washing method, with air compressor of minimum 750 CFM capacity, pumping pipe of 200 mm size and air line of minimum 65 mm size or with other suitable method,till the well is thoroughly developed as per clause 4.2 of IS 11189-1985, with upto date anebdnebts, if any, complete in all respects as per direction of the Engnieer -in- Charge.

30

-

-

... More
Development of tubewell by continus over pumping method,with VT pump/submerssible pumps of suitable capacity not less than double the discharge established by the compressor method/ design discharge,untoll the well is sand free as per IS-11189-1985 up to date amendment,if any complete in all respects as per directions of the Engineer - in- Charge. The draw down and discharge to be established by running the VT/Submerssible pump continously for 8 hours in the pressence of office not less than the rank of Assistant Engineer

20

-

-

... More
Testing the verticality of the tubewell as per clause 4.3 of IS 2800 ( Part-II) 1979 with upto date amendments, if any, using plumb or plunger 6 mm smaller in dia within the inside diameter of the well casing.The results of the verticality test shall be recorded on proforma shown in Appendix A of IS 2800 (Part-II) 1979 with up-to-date ammendments, if any, as appended with the tender documents and handed over complete in all respect as the directions of the Engineer -in- Charge.

1

-

-

... More
Dismentalling of Rig or other allied accesssories after completion of job within all leads & lifts, complete in all respects as per the directions of the Engineer -in- Charge.

1

-

-

... More
Handing over of the tubewell in complete shape as per appendex "B" of clause 7 of IS 2800 (Part-II) -1979 with upto date ammendmentes if any, as appended with the tender documents, in laminated form , in triplicate, complete in all respect as per the directions of the Engineer-in-Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.