Institute Of Himalayan Bioresource Technology Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Institute Of Himalayan Bioresource Technology - IHBT Tender
Civil And Construction
Building Construction
Eprocure
Opening Date23 Jun 2022
Closing Date5 Jul 2022
Tender Amount₹ 16,44,725
Costs
EMD
₹ 30,100Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_CSIR_120006_1Bid Award Id
ViewTender No
5-271/ws/22Tender Authority
Institute Of Himalayan Bioresource Technology ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT and contract document for the work of Construction of Food Processing Facility at CSIR-IHBT Palampur (Electrical Works)
BOQ for the work of Construction of Food Processing Facility at CSIR-IHBT Palampur (Electrical Works)
BOQ Items
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit as required. (FRLS Copper wire make: KEI/Anchor/Finolex/Polycab) i) 2x4 sqmm + 1x4 sqmm earth wire
215
-
-
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit as required. (FRLS Copper wire make: KEI/Anchor/Finolex/Polycab) i) 4x2.5 sqmm + 2x2.5 sqmm earth wire
47
-
-
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit as required. (FRLS Copper wire make: KEI/Anchor/Finolex/Polycab) i) 4x4 sqmm + 2x4 sqmm earth wire
429
-
-
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit as required. (FRLS Copper wire make: KEI/Anchor/Finolex/Polycab) i) 4x6 sqmm + 2x6 sqmm earth wire
20
-
-
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed ISI medium class PVC conduit as required. (FRLS Copper wire make: KEI/Anchor/Finolex/Polycab) i) 4x10 sqmm + 2x6 sqmm earth wire
15
-
-
Supplying & drawing following pair 0.5 mm dia FRLS PVC insulated anneaaled copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(FRLS Telephone wire make: KEI/Anchor/Finolex/Polycab) i) 2 Pair
70
-
-
Supplying & fixing of following sizes of ISI medium class PVC conduit alongwith accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. i) 25 mm
210
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. ( Modular accessories make: Anchor ROMA/ Havells crabfree/ Wipro North West) i) Telephone socket outlet
3
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. (Modular accessories make: Anchor ROMA/ Havells crabfree/ Wipro North West) i) 3 pin 5/6 A socket outlet
4
-
-
Supplying & fixing 2 Module Stepped type Electronic Fan Regulator on existing Modular Plate Switch box including connection but excluding modular plate extra as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
8
-
-
Supplying & fixing modular blanking plate on the existing modular plate switch box excluding modular plate as required. (Modular accessories make: Anchor ROMA/ Havells crabfree/ Wipro North West)
10
-
-
Supplying & fixing following size/ modules, GI/ PVC box alongwith modular base & cover plate for modular switchs in recess etc as required. i) 1 or 2 Module (75 mm x 75 mm)
3
-
-
Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
7
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the existing juction box/wooden block including connection etc. as required.
12
-
-
Installation, testing and commissioning of pre wired, fluorescent fitting/ compact fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, inc connection with 1.5 sqmm FRLS insulated, copper conductor, single core cable and earthing etc. as required.
54
-
-
Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length(upto 30 cm) with 1.5 sqmm FRLS insulated, copper conductor, single core cable inc providing and fixing Phenolic laminated sheet cover on the fan box etc. as required.
8
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: D Link/ Digilink) i) 1 Run of Cable
60
-
-
Supplying & fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 Pin 5/6 Amp. Modular socket outlet and 2 Nos. 5/6 Amp. Modular switch, connections etc. as required. ( FOR LIGHT PLUGS TO BE USED IN NON RESIDENTIAL BUILDING). (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
43
-
-
Supplying & fixing suitable size GI box with modular plate and cover infront of surface or in recess including providng and fixing 25 amp modular socket outlet and 25 amps. Modular SP MCB "C" curve including connections, painting etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
2
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreadders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.(Make: Legrand/ Panasonic/ Hager/ Schneider). i) 100A, 16KA, TPMCB
2
-
-
Supplying and fixing following way, Single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).(Make: Legrand/ Panasonic/ Hager/ Schneider). i) 12 way , Double door
3
-
-
Supplying and fixing following way, surface/ recess mounting, horizontal type three pole and neutral,sheet steel,MCB distribution boad,,415 V, complete with , tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections,powder painted,including earthing etc. as required. (But without MCBs and incomer) as required. (Make: Legrand/ Panasonic/ Hager/ Schneider). i) 6 way (4 + 18), Double Door
1
-
-
Supplying and fixing following way, surface/ recess mounting, vertical type,415 V, TPN MCB Distribution Board, sheet steel, dust protected, powder painted, inclusive of 200 A, tinned copper bus bar, neutral bus bar, earth bar, din bar for mounting MCBs (But without MCBs and incomer) as required. (Make: Legrand/ Panasonic/ Hager/ Schneider). i) 8 way (4 + 24), Double Door
2
-
-
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) Single pole
66
-
-
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) Single pole & Neutral
3
-
-
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) Triple pole
10
-
-
Suppying and fixing following rating, four pole 415 V,isolator in the existing MCB DB Complete with connections,testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) 63 A
1
-
-
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ).
10
-
-
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia GI pipe from earth electrode including connection with copper thimble excavation and refilling as required.
12
-
-
Providing and fixing 4.00 mm dia. Copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submaain wiriring/cable as required.
66
-
-
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i) Upto35 sqmm
510
-
-
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i) Above 35 sqmm and upto 95 sqmm
120
-
-
Laying of one number PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. i) Above 95 sqmm and upto 185sqmm
120
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i) Upto 35 sq.mm (Clamped with 1mm thick saddle )
110
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i) Above 35 sq.mm and up to 95sq.mm(Clamped with 25x3mm MS CLAMP)
20
-
-
Supplying & fixing of following size DWC HDPE pipe ISI marked along with all aacessories like socket, bend, couplers etc. confirming to IS 14930, Patr II complete with fitting and cutting, jointing etc. in exsting trench surface,as required. i) 63 mm Dia ( OD - 63 MM mm & ID 51 mm nominal)
50
-
-
Supplying & laying of following size DWC HDPE pipe ISI marked along with all aacessories like socket, bend, couplers etc. confirming to IS 14930, Patr II complete with fitting and cutting, jointing etc. direct in ground(75 cm below ground lavel) including excavation and refilling the trench but excluding sand cushioning and protective covering etc,as required. i) 63 mm Dia ( OD - 63 MM mm & ID 51 mm nominal)
410
-
-
Supplying & laying of following size DWC HDPE pipe ISI marked along with all aacessories like socket, bend, couplers etc. confirming to IS 14930, Patr II complete with fitting and cutting, jointing etc. direct in ground(75 cm below ground lavel) including excavation and refilling the trench but excluding sand cushioning and protective covering etc,as required. i) 120 mm Dia ( OD - 120 MM mm & ID 103 mm nominal)
30
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(FRLS Copper wire make: KEI/Anchor/Finolex/Polycab) i)2x1.5 sq.mm
150
-
-
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.(Make: Apollo/System sensor)
8
-
-
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Make: Apollo/System sensor)
9
-
-
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as require. (Make: HSD/Agni device/System sensor)
1
-
-
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.(Make: HSD/Agni device/System sensor)
1
-
-
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.(Make: HSD/Apollo/System sensor) i)4 Zone
1
-
-
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as require.(Make: KEI/Finolex/Polycab)
200
-
-
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3.5 core 50 sqmm
60
-
-
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3.5 core 120 sqmm
120
-
-
SITC I/O Box with SMB (Surface Mount Box for internet socket) and Dual Face Plate – with Dual keystone Jack (Make: Dlink/digilink).
6
-
-
SITC of Webmanaged switch 24 Port 10/100/1000 Gbps Ports with 2 SFP Ports alongwith 2 SFP modules (Make: Dlink or equivalent)
1
-
-
Supllying, Installation, testing and commissioning of 12U Wall Mount Rack with accessories (Cable Manager, Patch Panel, Power Distribution, Mounting Hardware) make: Comrack or equivalent.
1
-
-
Supllying, Installation, testing and commissioning of Fully Loaded 12 port wall mount LIU with connecting panel, adaptors, pigtail cables & other accessories with complete termination of OFC pairs as required (Make: Dlink/Digilink)
1
-
-
SITC of 2m Multimode patch cord with SC connectors as required (Make:- Dlink/digilink).
1
-
-
Supplying and testing of surface mounted 36 Watt LED flat panel 2' x 2' made of CRCA sheet steel duly powder coated with high efficient LED & Glare free full opel Diffuser with system lumens-120LM/watt, Height of Fixture 40mm complete as required. (Make : Wipro/ Bajaj/ philips).
24
-
-
Supplying of 5 star rated Ceiling Fans 1200 mm sweep with white colour. (Make: Havells/ Bajaj/ Crompton) .
8
-
-
Supplying & fixing Single Phase,230 volts, 450 mm sweep, , wall mounted air circulator fan with three speed setting and three blade (Blade material aluminium), having RPM 1440 approx, air delivery 4400 CFM approx complete as required. (Make: Bajaj/ Havells/ Crompton/ Almonard)
7
-
-
Supplying & fixing Single Phase,230 volts, 380 mm sweep, heavy duty metal body exhaust fan, approx 1400 RPM, four blades, air delivery Approx 3600 CMH as required. (Make: Bajaj/ Havells/ Crompton)
5
-
-
Supplying and testing of LED Batten light 20W having extruded aluminium body. (Make: Philips / bajaj/ Wipro ).
10
-
-
Supplying and testing of industrial Extruded/ Die cast Aluminium LED Batten light 40W having high efficiency, sustainable lighting with surface mounting with efficacy of 120 Lm/watt(Make: Philips / bajaj/ Wipro).
16
-
-
Supplying and fixing of LED flood light 45W having extruded aluminium body. (Make: Philips / bajaj/ Wipro ).
4
-
-
Supplying & Laying of 20 Pair armoured telephone cable in DWC (ISI Marked) HDPE pipe as required.(Make: Delton / Polycab/ Finolex)
170
-
-
Supplying & drawing of 6 core Mutimode Armoured Optical fiber cable (50/125 μm) as required.(Make: D Link/ Molex/ Digilink)
170
-
-
SITC 20 Pair telephone box with Krone module. ( Box Make : Havells or eq, Module Make: Krone or Eq.).
1
-
-
Supply, fabricating, installing, testing, commisioning of factory (CPRI approved) made, krone distribution box approx. size (300*350*250*) outdoor type, floor mounted. CRCA sheet 1.6mm thick, fully compartmentalised, legs(30*30*3) 600mm long with IP-65 protection. Including provision of following accessory/ components housed in it:- i) Chasis inside to fix krone device on spot for termination of telephone cable. ii) 22.2mm knock out holes at the bottom. iii) 10Pair Telephone Krone Module= 02 No.
1
-
-
Supply, febricating, installing, testing, commisioning and electrically connected factory (CPRI approved) made, LT panel board of approved sizes as recommended by IS & CPRI norms,(1.3x0.9x0.4--LXHXD Mtrs. approx.)indoor type,made out of 2.00mm CRCA sheet.Powder coated with pure polyester grade powder.Panel should be fully compartmentalised floor mounted with frame& legs of 5mm M.S 300MM Long with square plate at bottom to grout the panel. 1100 volts, with IP-65 protection for 415 volts,3 phase 4 wire system AC supply, complete all as specificatio including provision of following accessory/ components housed in it:- i) 250 Amp rated Al. bus bar with color code TPN mounted on epoxy insulator :01 set(set of 04 bus bars) ( 1mm SQ=1Amp) ii) Digital Multifunction metre 0-250 Amp with suitable CT'S-01 Set iii) LED indicating lamp (Set of three)-01 Set iv) Internal wiriring with 1100 volt grade unsheathed PVC insulated copper conductor of suitable size. Cable as per colour coding or suitable size of bus bar for all connections with suitable lugs as required and as specified. v) Earthing terminals and cable glands. made out of CRCA sheet 3.0 mm thick for load bearing and2.0mm thick for non-load bearing, fully compartmentalised, with IP-65 (certificate not order than 2 years). protection with baes legs of 5mm thick angle(900mm Long) for 415 volts, 3 phase 4 wire AC supply, complete all as specified including provision of following accessory/ components housed in it:-i)400 amp rated AI. bus bar with color code TPN mounted on epoxy insulators=01 set(set of 4 bus bars) ii) Digital multifunction metre 0-400 amps with suitableCT'S =01 set.iii) LED indicating Lamp (Set of Three)=01 set.iv) Internal wiriring with 1100 volts grade unsheathed PVC insulated copper conductor of suitale size cable as per colour coding or suitable size of bus bar for all connections. v) Earthing terminals and cable glands,vi) Danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel board door. Incoming:- i)250 A, 4pole, MCCB,adj-T Adj-M based, rupture capacity 25 ka.(Spreader links inc.)=01 No. Outgoing:- i)MCCB 100 A ,TP+NL 10 KA Fxd.(Spreads Links Inc)=01 No. ii)MCCB 80 amps,TP+NL 10KA Fxd.(Spreader links Inc.)=02 No. iii) MCB 63 Amps.4 P 10 KA C- Curve with terminal block =02 No. (Digital MFM & Indicator make: C&S/ L&T/ Schneider, MCCB Make: L&T/ Havells/ Indo Asian).
1
-
-
Supplying & fixing Integral Pole Mounted 45 Watt LED Post Top Lanteren with die cast aluminium spigot, spun aluminium powder coated top cover and clear acrlic diffuser with IP-65 protection. (Make: Bajaj/ Wipro/ Philips)
6
-
-
Supplying & fixing MS Tubular Pole 65 mm Dia as per IS2713, 1980 inc. wiring the pole with 2x1.5 sqmm FRLS Copper wire. Pole is of 3.5 Mtr. Length with 3.6 mm thickness, M.S plate welded at bottom, having 25 mm Dia hole at centre. Painting one coat of red oxide and two coat of black paint etc. as required.
6
-
-
Supplying & installation of Poly Carbonate, Weatherproof, Waterproof street light terminal box with Bus Bar, one no. 6 amp. Single Pole MCB and neutral link including front lockable cover of approx size 200 x 200 x 120 and connection complete as required. (Make: Sintex or Eq.)
6
-
-
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3 core 16 sqmm
70
-
-
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement:3coarse sand:6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. 1) Above 4.5 metre and upto 6.5 metre
6
-
-
Providing and making steel pole coller with cement concrete(1 cement:3 coarse sand:6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to bededucted)
1.5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements