Indo Tibetan Border Police Tender
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.
Indo Tibetan Border Police - ITBP Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date24 May 2023
Closing Date5 Jun 2023
Tender Amount₹ 2,81,14,794
Costs
EMD
₹ 5,62,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Const Of 250 Kld Sewage Treatment Plant Including Development Work At 43rd Bn Itbp
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_ITBP_754691_1Bid Award Id
ViewTender No
ITBP/SHQ SML/43RD BN/ ENGR-3659 DTD 23.05.23Tender Authority
Indo Tibetan Border Police ViewPurchaser Address
-Website
http://https://www.itbpolice.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.Ordinary rock :
91.37
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m.
521.55
-
-
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials : Ordinary or hard rockabove 1.50 mtr upto 3 mtr
656.09
-
-
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials : Ordinary or hard rockabove 3 mtr upto 4.50 Mtr
514.48
-
-
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials : Ordinary or hard rockabove 4.50 mtr upto 6.00 Mtr
12.95
-
-
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
2.7
-
-
Surface dressing of the ground including removing vegetaion and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5m.All Kinds of Soil.
629
-
-
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
629
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - level :All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone III): 4 graded stone aggregate 20 mm nominal size)
18.93
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - level :All work up to plinth level :1:4:8 ( 1 cement : 4 coarse sand(zone III) : 8 graded stone aggregate 40 nominal size).
67.53
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns (PCC work)
41.7
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.: Foundations, footings, bases of columns etc. for mass concrete.
196.9
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.:Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc.
1763.04
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.: Suspended floors, roofs, landings, balconies and access platform.
241.06
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.:Shelves (Cast in situ).
5
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.: Lintels, beams, plinth beams, girders, bressumers and cantilevers.
21.6
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.: Columns, Pillars, Piers, Abutments, Posts and Struts.
43.2
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.: Stairs, (excluding landings) except spiral-staircases.
5
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.: Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands,copings, bed plates, anchor blocks and the like.
1.04
-
-
Centring and shuttering inlcuding strutting, propping etc. and remval of form for all height.: Edges of slabs and breaks in floors and walls Under 20 cm wide
90
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
56820.86
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more.
2371.75
-
-
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting
of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
500.47
-
-
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting
of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
20.89
-
-
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand).
0.6
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
20.09
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth incement mortar 1:4 (1 cement : 4 coarse sand)
5
-
-
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
5
-
-
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with : Cement mortar 1:6 (1 Cement : 6 coarse sand)
146.2
-
-
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6 mm for diagonal braces
5.04
-
-
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. Medium class MS tube.
2570
-
-
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
29.67
-
-
Extra for providing and fixing wind ties of 40 x 6 mm flate iron section.
158.4
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
241.3
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Ridges plain (500 - 600mm).
26.4
-
-
12 mm cement plaster of mix: 1:4 (1 cement : 4 coarse sand)
5
-
-
12 mm cement plaster of mix: 1:6 (1 cement : 6 coarse sand)
34.96
-
-
15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement : 6 coarse sand)
52.43
-
-
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
87.39
-
-
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
12
-
-
Applying One coat of water thinnable cement primer of approved brand and manufacture on wall surface.Water thinnable cement primer
5
-
-
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
5
-
-
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
87.39
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
50
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade . Two or more coats on new work
87.39
-
-
Painting with Synthetic enamal paint of approved brand and manufacture to give an even shade:Two or more coats on new work.
5.46
-
-
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats.
99.39
-
-
Supplying and stacking at site. 90 mm to 45 mm size stone aggregate
84.38
-
-
Supplying and stacking at siteOver burnt (Jhama) brick aggregate 90 mm to 45 mm
150
-
-
Supplying and stacking at site.Stone screening 13.2 mm nominal size (Type A)
37.5
-
-
Providing and laying water proofing treatment in sunken portion of (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
511.6
-
-
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
1392.24
-
-
Supply, Installation, Testing & Commissioning of Coarse SS Bar Screen (SS 304 fabricated) of size 700MM X 800MM with 10MM-12MM opening along with SS Frame for lifting to block the in organics like bottles, glass, polythenes etc complete as reqd.
1
-
-
Supply, Installation, Testing & Commissioning of submersible Sewage Transfer pumps (Motor Capacity: 2.0 HP) suitable for handling upto 20mm solid particles having a liquid discharge rate of 6250 Ltr/hr (each) at a head of 12 metres incorporating C.I. casing, CI impeller, CI motor body with Nylon lifting rope 16mm-20mm thick and suitable for operation on 3-phase 415- Volt AC supply with similar specification. 3 Nos Pump - [02 Working + 01 SB] complete etc. as reqd.
3
-
-
Supply, Installation, Testing & Commissioning of Ventury based air injection system (Motor: 0.5 HP) for increasing Dissolved Oxygen (DO) in the Equalization Tank (make: Plastic Fibre Corporation/Brill Tech/Warun Enterprises)
1
-
-
Technology provider fee for designing of STP & supply of 1200 kgs of living soil medium; a specialized microbe pre-treated media formulated using specially bred catalyst culture, sugar & protein source, and fermented for 24 hrs, sun dried, sieved and packed for creating required ecosystem in the Advanced Eco Reactor including providing technical know-how for project execution.
1
-
-
Supply, Installation, Testing & Commissioning of 21 tons of Organic biosorption media consisting of slow release carbon rich material along with unloading & filling into the Advanced Eco Reactor.
1
-
-
SITC of Plastic Crates for housing of living soil medium and organic bioadsorption media Unit Size : 520 mmX 360mm X 280 mm; MOC: Recycled Plastic
1000
-
-
Supply, Installation, Testing & Commissioning of planting material, growth promoters and enhancers etc for green zoning
1
-
-
Supply & inoculation of probiotic microbial mother culture for development of microbial bio-film on the surface of the inert media.
382
-
-
Supply, Installation, Testing & Commissioning of openwell submersible pumps (Motor Capacity: 1 HP) having a liquid discharge rate of 12500 Ltr/hr (each) at a head of 10 metres incorporating C.I. casing, CI impeller, CI motor body with Nylon lifting rope 16mm-20mm thick and suitable for operation on 3-phase 415- Volt AC supply with similar specification. complete etc. as reqd.
2
-
-
Supply, Installation, Testing & Commissioning of ASTM approved UPVC Sch 40 Piping work for with all necessary accessories like ball valves, b/f valves, elbow, unions, flange, Non returnable valves MTA, FTA, coupler, tees, reducers, pressure gauge, clamps, fastners etc for making the AER grid complete as required along with 02 no. helix disc filter and ISI marked PVC pipe for taking the AER outlet into the UG Feed Tank.
1
-
-
Supply, Installation, Testing & Commissioning of fabricated Motor Control Panel made of 2mm thick CRCA sheet duly powder coated with necessary switch gears such as INCOMER MCCB of required amp with outgoing switch gears for auto operation of 02 no. sewage pumps, 01 nos. VFD, 01 nos. Ventury System for DO maintenance, 02 nos. openwell submersible pumps, 1 Nos. Ozonation System, 02 nos. Treated water pumps (upto 5 HP) along with necessary MCBs, VIF meter, indication light, protection MCB and DOL Starter with MCB over load relay, Single Phase Preventer relay, on-off light push button, auto - manual selector switch, cyclic timer for auto change-over of pumps, dry run protection.
1
-
-
Supply, Installation, Testing & Commissioning of unarmoured/flexible Copper control wiring of suitable size in pvc channel/conduit/MS pipe from STP panel to all the pumps and other electrical equipments complete as required.
1
-
-
Supply, Installation, Testing & Commissioning of online pH meter to measure acidity or alkanity of the treated water etc. as required.
1
-
-
Supply, Installation, Testing & Commissioning of baloon type PP liquid water level controller for all pumps to ensure respective pumps start/stop automatically to prevent any unwanted overflow/damage of pumps with 3 mtrs wire complete as required.
6
-
-
Ozone generation system (capacity 100 gms) with recirculation system including recirculation CPVC piping & recirculation pump with servo stabiliser for disinfection & polishing of waste water.
1
-
-
Supply, Installation, Testing & Commissioning of PVC tank (capacity: 1000 litres) fitted with ball valve and dosing pipe for dosing of activated bacterial culture in the collection tank
3
-
-
Operation & preventive maintenance of STP by 01 no. operator all days in a month (8.5 hrs shift). The cost shall include:
a. Operation of STP
b. Dosing of activated probiotic bacterial culture (250 litres/day)
d. Mainentenance of STP log book and dosing register
e. Repair & maintenance i/c replacement of defective parts i/c rewinding of motor, repair of pump, pipe, panel or any other electrical or mechanical equipment under DLP
(Bacteria Make: OS1/Envirosense/Ecolog)
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements