Himachal Pradesh State Load Despatch Centre Tender

... More
Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh State Load Despatch Centre - HPSLDC Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Apr 2025
Closing Date24 Apr 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Supply Installation Commissioning And Testing Of Air Conditioning Units In The Hpsldc Backup Control Centre Mattansidh Hamirpur Hp

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and installation of Inverter 3.0 TR Cooling Only Cassette AC Non-Inverter with R32 Refrigerant Power Supply 1 Phase 230V, 50 Hz, Cooling capacity Rated 8.79-12.31 KW, Annual Power Consumption 1865.6-3024.44 KWh, ISEER 2.9-3.6Wh, Air Flow Rate 1218-706 CFM, Rotary Compressor, Sound Level 45-32.5 dBA, Certified Operation Range 19 to 48 ° CDB testing etc. complete in all respect with best satisfaction of Engineer -in- Charge. Make: Daikin, Mitsubishi Electric, O General, Voltas or equivalent.

2

-

-

... More
Providing and fixing of Nitrile Tubular Insulation ac indoor to outdoor for COPPER PIPING as per IS Specification (Heavy Duty) complete in all respect with best satisfaction of Engineer -in- Charge.

108

-

-

... More
New 125kVA Voltage Regulator

-

-

-

... More
Supplying and fixing of 25mm dia of PVC drain pipe along with the accessories as per IS Specification (Heavy Duty) complete in all respect with best satisfaction of Engineer -in- Charge.

110

-

-

... More
Providing and fixing of copper tube for refrigerant size (15.88 mm-9.52mm) for Split AC 1.5 TR unit as per IS Specification (Heavy Duty) complete in all respect with best satisfaction of Engineer -in- Charge.

108

-

-

... More
Providing and laying of communication wire 6.00 Sq.mm. 4 Core Copper conductor cable as per IS-694:1990 standards, Voltage grade 1100 V, PVC insulation, Heat Resistant Flame Retardant and Low Smoke (HRFRLS). Make: Finolex, Havells, Anchor, Ploycab, Syska or equivalent.

65

-

-

... More
Providing and fixing of Timer for AC as per IS Specification complete in all respect with best satisfaction of Engineer -in- Charge.

5

-

-

... More
Providing and installation of 1.5 TR Cooling Only Split Type AC 5 star 4kVA Voltage Stabilizer with R32 Refrigerant, Power Supply indoor Unit 3 Phase 400 V, 50 Hz, Power supply Outdoor Unit 3 Phase 400 V, 50 Hz, Cooling Capacity rating 12.59-14.6 KWPower Consumption Cooling Rated 3900- 4200 Watt, ISEER 3.5 to 4, Air Flow 1288-742 CFM, Operating Range18° to 48° CDB with scroll Compressor, making connections, testing etc. complete in all respect with best satisfaction of Engineer -in- Charge Make: Daikin, Mitsubishi Electric, O General, Voltas or equivalent .

1

-

-

... More
Providing and installation of Inverter 2.0 TR Cooling Only 2 Star Cassette AC Non-Inverter 5kVA Voltage Stabilizer with R32 Refrigerant Power Supply 1 Phase 230V, 50 Hz, Cooling capacity Rated 5.30-8.79 KW, Annual Power Consumption 1124-1865.6 KWh, ISEER 3.2-3.8 Wh, Air Flow Rate 812-477 CFM, Rotary Compressor, Sound Level 37-27.5 dBA, Certified Operation Range 19 to 48 ° CDB testing etc. complete in all respect with best satisfaction of Engineer -in- Charge. Make: Daikin, Mitsubishi Electric, O General, Voltas or equivalent.

2

-

-

... More
Providing and fixing of MS Pre-fabrication condensing unit stands as per IS Specification (Heavy Duty) complete in all respect with best satisfaction of Engineer -in- Charge.

12

-

-

... More
Providing and fixing of MS Galvanised cable tray of size 100mm x 50mm as per IS Specification (Heavy Duty) complete in all respect with best satisfaction of Engineer -in- Charge.

45

-

-

... More
Providing and laying of Control wire 2.5 Sq.mm. (4 core) Copper conductor cable as per IS-694:1990 standards, Voltage grade 1100 V, PVC insulation, Heat Resistant Flame Retardant and Low Smoke (HRFRLS) as per IS Specification (Heavy Duty) complete in all respect with best satisfaction of Engineer -in- Charge. Make: Finolex, Havells, Anchor, Ploycab, Syska or equivalent.

130

-

-

... More
Providing and fixing 63 Amp TP&N disconnector fuse switch unit as per IS/IEC 60898-1, MCB TPN 415 Volts 63A, 3P+N, 10KA Category- A complete in all respect with best satisfaction of Engineer -in- Charge. Make: Havells, L&T, Gold medal, Schneider Electric, Legrand or equivalent.

1

-

-

... More
Providing and installation of Inverter 1.8 TR Cooling Only Non-Inverter 2 star 5kVA Voltage Stabilizer with R32 Refrigerant Power supply 1 Phase 50 Hz, 230 V, Rated Cooling Capacity 4.3-7.2 KW, Rated Annual Power Consumption 1230-1560 kwh, Rated ISEER 2.3-4.2 Wh, Operating current 7.3-9.2 A, Operation Sound 54-35 DBA, Rotary Compressor, Operating Ambient Temperature 19.4-50 ° CDB testing etc. complete in all respect with best satisfaction of Engineer -in- Charge. Make: Daikin, Mitsubishi Electric, O General, Voltas or equivalent.

3

-

-

... More
GRAND TOTAL:

-

-

-

... More
Providing and fixing 6 amps. to 32 amps. ratings, SP MCB, “C” curve, 10 KA breaking capacity in all respects and as per direction and satisfaction of Engineer in charge.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.