Himachal Pradesh State Electricity Board Limited Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh State Electricity Board Limited - HPSEBL Tender

Turnkey Projects
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date31 Aug 2022
Closing DateCancelled
Tender Amount₹ 1,60,51,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
10.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-'A') as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-47

182

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

996

-

-

... More
Pre-fabricated galvanised steel (zinc coating 610gms/sqm), items like DC cross arm (100x50x6 mm), back clamps (50x6 mm), pole clamp (65x8 mm), DO fuse mounting channel (75x40x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work.

159.36

-

-

... More
GS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.

13.45

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, Guy insulator ( 1Nos.), anchor plate (200x200x6mm), nut bolts, 2 Nos turn-buckles,1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

1992

-

-

... More
Polymer/ Porcelain Insulators with hardware fittings, hardware etc as required as per technical specification, approved drawings and scope of work.

-

-

-

... More
11 KV Disc insulator B&S type conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 255 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavily polluted atmospheres Creepage distance-400 mm

1127

-

-

... More
22 KV Disc insulator B&S type ( 2 nos. disc) conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 225 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavily polluted atmospheres Creepage distance 400 mm

273

-

-

... More
Distribution Transformer Substation using new outdoor type, oil immersed, distribution transformer up to and including 630 KVA as per IS1180 (Part-1): 2014 and its amendments 1, 2, 3 and 4,RGO/Amorphous core, Energy Efficiency Level 1, carrying Bureau of Indian Standard Certificate mark, in following preferred ratings as per detailed scope of work and technical specifications:

-

-

-

... More
11/0.230 kV Distribution Transformer 16 KVA 1 Phase Aluminium wound DTR

47

-

-

... More
11/0.4 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR

90

-

-

... More
22/0.4 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR

25

-

-

... More
11/0.4 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR

183

-

-

... More
22/0.4 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR

56

-

-

... More
11/0.4 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR

42

-

-

... More
22/0.4 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR

10

-

-

... More
11/0.4 KV Distribution Transformer 250 KVA 3 phase Aluminium wound DTR

25

-

-

... More
11/0.4 KV Distribution Transformer 400 KVA 3 phase Aluminium wound DTR

15

-

-

... More
11/0.4 KV Distribution Transformer 630 KVA 3 phase Aluminium wound DTR

5

-

-

... More
Outdoor mounting type Distribution box made of MS sheet of thickness not less than 18 SWG CRCA sheet/ SMC Distribution Box, dust and moisture vermin, weather proof with degree of protection with suitable bus bars, earthing cum neutral bus, earthing terminals, box illumination, front door operated with proper locking arrangement, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware as per scope of the work, technical specifications and approved drawings suitable for following transformer:

-

-

-

... More
1 Ph 16 KVA transformer 80 A SPN MCCB (incomer) and 2 Nos. 50 A SP MCCB (outgoing)

47

-

-

... More
3 Ph 25 KVA transformer 40 A TPN MCCB (incomer) and 6 Nos. 25 A SP MCCB (outgoing)

115

-

-

... More
3 Ph 63 KVA Transformer having 200 A TPN isolator, 100 A HRC fuse (incomer) and 6 Nos. 60 A SP MCCB (outgoing)

239

-

-

... More
3 Ph 100 KVA Transformer having 200 A TPN isolator, 160A HRC fuse (incomer) and 6 Nos. 90 A SP MCCB (outgoing)

52

-

-

... More
LT Distribution Panel Box suitable for 250KVA S/Stn of size 1100x800x275mm +/- 5% made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated painted complete with 2 no. MCCB's ( 1main + 1 spare) Rating 400Amp, 3 Poles having following specifications (1) Minimum frame size 400Amp (2) Type variable trip free, (3) Breaking capacity- Isu & LCS at 415, 50 Hz (KA: not less than 50 KA) (4) , Thermal release range: 320-440Amp (5) Mecanical life (operation) 20000 No. (6) Electrical life (operation) 4000 No. (7) Rated insulation voltage (V) 690V (8) Tripping thermal releasing setting : Thermal-O/L variable setting (9) Tripping magnetic releasing setting : Magnetic- S/C fixed setting (12) in (10) (Operation) volatge 415V, AC (11) Caliberation temperature: 40 degree C (12) High voltage withstand voltage : 3KV for 1 minute (13) Confirming to IS : 1993/60947-2, 1989 (14) Make L&T/ Havells/ABB/ HPL/ Schneider (15) ICS : 100% ICU

25

-

-

... More
LT Distribution Panel Box suitable for 400KVA S/Stn. made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated pained complete with ACB Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical breaking capacity 50KA, Service Breaking Capacity 100% Icu, Rating Making Capacity 105KA Peak, Short circuit time for seconds (KA rms) 50KA, Thermal Current set value 1000 Amp, Time for which breaker can carry its rating breaking current 40 MS, Endurance (CO) Cycle Mechanical not less than 8000 operations, Electrical Not less than 5000 operations, Electrical life for Arcing contacts not less than 2500 operations, Insultion Voltage 1100 Volts, Impulse with stand voltage 8KV, Closing Mechanism Mannual independent mannual, Version required fixed and make L&T/Havells/C&S/HPL/Schneider

15

-

-

... More
LT Distribution Panel Box suitable for 630KVA S/Stn. made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated pained complete with ACB Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical breaking Capacity 50KA, Service Breaking Capacity 100% Icu, Rating Making Cap. 105KA Peak, Short circuit time for seconds (KA rms) 50KA, Thermal Current Set Value 1000 Amp, Time for which breaker can carry its rating breaking current 40 MS, Endurancec (CO) Ciycle Mechanical not less than 8000 operations, Electrical Not less than 5000 operations, Electrical life for Arcing Contacts not less than 2500 operations, Insulation Voltage 1100 Volts, Inpulse with stgand voltage 8KV, Closing Mechanism Mannual independent mannual, Version Required Fixed and Make L&T/Havells/C&S/HPL/Schiender.

5

-

-

... More
9kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestor complete with accessories for 11KV system

1221

-

-

... More
18 kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestor complete with accessories for 22 KV system

273

-

-

... More
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

407

-

-

... More
22 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

91

-

-

... More
11 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings

407

-

-

... More
22 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings

91

-

-

... More
3 Nos pipe earthing using 40mm dia GI pipe 3000 mm long, making earth grid using 50x6mm GI Flat and riser as per scope of work of Distribution Transformer Substations, as per scope of work, approved drawings and technical specifications,

1494

-

-

... More
8 SWG GI wire for earthing as per technical specifications, approved drawings and scope of works.

5

-

-

... More
PVC 3.5 Core Aluminium Conductor, Stranded, unarmoured cable i/c thimbles of suitable size for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line i/c proper clamping clamping of Cables as per Scope of work, technical specification and approved drawings:

-

-

-

... More
3.5 Cx16 sqmm aluminium conductor cable

1.41

-

-

... More
3.5 CX35 sqmm aluminium conductor cable

5.8

-

-

... More
3.5Cx70 sqmm aluminium conductor cable

14.34

-

-

... More
3.5Cx120 sqmm aluminium conductor cable

3.12

-

-

... More
3.5Cx185 sqmm aluminium conductor cable

1.5

-

-

... More
3.5Cx300 sqmm aluminium conductor cable

1

-

-

... More
3.5 Cx400 sqmm aluminium conductor cable

0.3

-

-

... More
Danger Plate Size: 250x200x1.6 mm made of mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and signal red colour on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to IS specifiction no. IS-1351/1982 suitable for 11/22KV System

498

-

-

... More
Galvanised steel barbed wire of 9.8 kg /100metre

7.47

-

-

... More
Aluminium Paint for all poles and steel fitting

1992

-

-

... More
Red Oxide

1494

-

-

... More
ACSR Rabbit Conductor for jumpering including PG Clamps, bi- metallic connectors, hardware etc as per technical specifications, approved drawings and scope of works.

14.24

-

-

... More
New LT Line (Support for LT overhead Line as per technical specification, approved drawings and scope of work).

-

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

447

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

447

-

-

... More
Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.

447

-

-

... More
Earthing as per approved drawings, technical specifications and scope of work

-

-

-

... More
40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and Spike Earthing 20mm solid Rod i/c other accessories complete

179

-

-

... More
8 SWG GI wire for earthing & GI nuts, bolts & washers

3.06

-

-

... More
ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work

-

-

-

... More
6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit

117.8

-

-

... More
Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr]

4.4

-

-

... More
Shackle Insulator (16 kN)

1750

-

-

... More
D-Iron (U- Clamps)

1750

-

-

... More
Earth Knob

447

-

-

... More
Kit kat I.C

357

-

-

... More
Full Clamps [ 2 No for A.I + 1 No for Stay Set]

1340

-

-

... More
Spool Tie

1750

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.73

-

-

... More
Aluminium Paint

460

-

-

... More
Spiral PVC Spacer

880

-

-

... More
Red Oxide

402

-

-

... More
Augmentation & Renovation of 11/0.4 kV Distribution Transformer Substation

-

-

-

... More
Augmentation of Distribution Transformer Substation using new outdoor type, oil immersed, distribution transformer up to and including 630 KVA as per IS1180 (Part-1): 2014 and its amendments 1, 2, 3 and 4, CRGO/Amorphous core, Energy Efficiency Level 1, carrying Bureau of Indian Standard Certificate mark, in following preferred ratings as per detailed scope of work and technical specifications under:Replaced DTRs to be deposited in Employer's store.

-

-

-

... More
New 63 KVA (11/0.4 kV) Aluminium wound DTR (Replacing 25KVA old DTR),

219

-

-

... More
New 63 KVA (22/0.4 kV) Aluminium wound DTR (Replacing 25KVA old DTR),

45

-

-

... More
New 100 KVA (11/0.4 kV) Aluminium wound DTR (Replacing 63 KVA old DTR),

110

-

-

... More
New 100 KVA (22/0.4 kV) Aluminium wound DTR (Replacing 63 KVA old DTR),

12

-

-

... More
New 250 KVA (11/0.4 kV) Aluminium wound DTR (Replacing 100 KVA old DTR),

61

-

-

... More
New 250 KVA (22/0.4 kV) Aluminium wound DTR (Replacing 100 KVA old DTR),

6

-

-

... More
New 400 KVA (11/0.4 kV) Copper wound DTR (Replacing 250 KVA old DTR),

38

-

-

... More
New 630 KVA (11/0.4 kV) Copper wound DTR (Replacing 400 KVA old DTR),

16

-

-

... More
Augmentation of DTR Substation by using new 3.5 C PVC Aluminium Conductor, Stranded, unarmoured cable for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line as per Scope of work, technical specification and approved drawings. Replaced cables to be deposited in Employer's store.

-

-

-

... More
3.5 Cx70 sqmm aluminium conductor cable

3.62

-

-

... More
3.5Cx120 sqmm aluminium conductor cable

8.52

-

-

... More
3.5Cx185 sqmm aluminium conductor cable

6.54

-

-

... More
3.5Cx300 sqmm aluminium conductor cable

3.13

-

-

... More
3.5Cx400 sqmm aluminium conductor cable

1.76

-

-

... More
Augmentation of DTR Substation by using new outdoor mounting type Distribution box made of MS sheet of thickness not less than 1.8 mm/ SMC distribution box, dust and moisture vermin, weather proof with degree of protection IP 33 as per IS 13947 with suitable bus bars, earthing bus, earthing terminals, box illumination, front door operated with proper locking arrangement, non magnetic 4 mm thick gland plate, double compression brass cable glands, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware as per scope of the work, technical specifications and approved drawings suitable for following transformer:

-

-

-

... More
3 Ph 63 KVA Transformer having 200 A TPN isolator, 100 A HRC fuse (incomer) and 6 Nos. 60 A SP MCCB (outgoing)

264

-

-

... More
3 Ph 100 KVA Transformer having 200 A TPN isolator, 160A HRC fuse (incomer) and 6 Nos. 90 A SP MCCB (outgoing)

122

-

-

... More
LT Distribution Panel Box suitable for 250KVA S/Stn of size 1100x800x275mm +/- 5% made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated painted complete with 2 no. MCCB's ( 1main + 1 spare) Rating 400Amp, 3 Poles having following specifications (1) Minimum frame size 400Amp (2) Type variable trip free, (3) Breaking capacity- Isu & LCS at 415, 50 Hz (KA: not less than 50 KA) (4) , Thermal release range: 320-440Amp (5) Mecanical life (operation) 20000 No. (6) Electrical life (operation) 4000 No. (7) Rated insulation voltage (V) 690V (8) Tripping thermal releasing setting : Thermal-O/L variable setting (9) Tripping magnetic releasing setting : Magnetic- S/C fixed setting (12) in (10) (Operation) volatge 415V, AC (11) Caliberation temperature: 40 degree C (12) High voltage withstand voltage : 3KV for 1 minute (13) Confirming to IS : 1993/60947-2, 1989 (14) Make L&T/ Havells/ABB/ HPL/ Schneider (15) ICS : 100% ICU

67

-

-

... More
LT Distribution Panel Box suitable for 400KVA S/Stn. made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated pained complete with ACB Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical breaking capacity 50KA, Service Breaking Capacity 100% Icu, Rating Making Capacity 105KA Peak, Short circuit time for seconds (KA rms) 50KA, Thermal Current set value 1000 Amp, Time for which breaker can carry its rating breaking current 40 MS, Endurance (CO) Cycle Mechanical not less than 8000 operations, Electrical Not less than 5000 operations, Electrical life for Arcing contacts not less than 2500 operations, Insultion Voltage 1100 Volts, Impulse with stand voltage 8KV, Closing Mechanism Mannual independent mannual, Version required fixed and make L&T/Havells/C&S/HPL/Schneider

38

-

-

... More
LT Distribution Panel Box suitable for 630KVA S/Stn. made of steel sheet of 1.63 mm thickness having double door locking arrangement duly powder coated pained complete with ACB Rating 1000Amp, Duty Circle 0.3 Sec, Rating Symmetrical breaking Capacity 50KA, Service Breaking Capacity 100% Icu, Rating Making Cap. 105KA Peak, Short circuit time for seconds (KA rms) 50KA, Thermal Current Set Value 1000 Amp, Time for which breaker can carry its rating breaking current 40 MS, Endurancec (CO) Ciycle Mechanical not less than 8000 operations, Electrical Not less than 5000 operations, Electrical life for Arcing Contacts not less than 2500 operations, Insulation Voltage 1100 Volts, Inpulse with stgand voltage 8KV, Closing Mechanism Mannual independent mannual, Version Required Fixed and Make L&T/Havells/C&S/HPL/Schneider.

16

-

-

... More
Renovation of DTR substation Earthing as per technical specification, approved drawings and scope of work:

-

-

-

... More
Revamping of Distribution Transformer substation earthing by using 40 mm dia 3 meter long GI pipe earthing, using 50x6 mm GS flat for earth mat and riser and 25x3mm GS flat for connecting equipment, using 200 kg bentonite powder of substation in normal soil

111

-

-

... More
Augmentation of DTR substation by new Pre-fabricated galvanised steel items like DC cross arm (100x50x6 mm), back clamps (65x8 mm), pole clamp (65x8 mm), DO mounting channel (75x40x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work.

3.8

-

-

... More
Augmentation of DTR substation by new Galvanised Steel (GS) Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.

0.81

-

-

... More
Augmentation of DTR substation by new 9KV, 11 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work.

1119

-

-

... More
Augmentation of DTR substation by 18 kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestor complete with accessories for 22 KV system

200

-

-

... More
Augmentation of DTR substation by new 11 kV, 3-ph, 200 A, 3 Pin type, Vertical Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

248

-

-

... More
Augmentation of DTR substation by new 22 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

50

-

-

... More
11kV, 200 A, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.

128

-

-

... More
22 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings

50

-

-

... More
Conversion of existing LT bare conductor line with following arrangements using new areal bunched XLPE cable,tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, 16 mm dia MS nuts & bolts, pole clamps, spring loaded bus bar suitable for single phase and three phase systems etc. as required as per technical specification, approved drawings and scope of work:

-

-

-

... More
AERIAL BUNCHED XLPE CABLE 3 X 70+50+16 SQ.MM

-

-

-

... More
LT AB Cable Cable on poles [Size: 3 X 70+50+16 SQ.MM {additional 1% sagging & wastage)

31

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

620

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

620

-

-

... More
Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.

600

-

-

... More
Half Clamp for Cross Arm

620

-

-

... More
Anchoring Assembly for LT

620

-

-

... More
Suspension Assembly for LT

620

-

-

... More
Facade Hooks for LT

620

-

-

... More
Distribution Boxes

190

-

-

... More
Earthing Set complete

160

-

-

... More
Red Oxide

560

-

-

... More
Aluminium paint

600

-

-

... More
Augmentation of 33/11 KV Fully outdoor type substation

-

-

-

... More
33/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type Power Transformer along with transformer oil, Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank, oil level indicator, valves, 2 sets of 50x8 mm GS Neutral Earthing strips {(with braided conductor on bushing end), isolating link, isolation with insulators}, Vent explosion plug, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, LV/HV bushing etc as required as per technical specifications, approved drawings and scope of the work.

-

-

-

... More
3.15 MVA without tap changer

2

-

-

... More
6.30 MVA with off load tap changer

8

-

-

... More
10.0 MVA with on load tap changer

3

-

-

... More
33KV Superstructure and equipment structure

-

-

-

... More
Galvanised super structure comprising gantries and columns

5.25

-

-

... More
Galvanised equipment structure for mounting 33KV Isolators and Post insulators

0.75

-

-

... More
36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 36kV, 1-Phase, 25kA/3 seconds, 200-100/5-5 Amps or 300-150/5-5 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), Jumpers, earthing, supporting structures, bi- metallic clamps, permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings

8

-

-

... More
33kV, Indoor, Control & Relay panel along with E/F & O/C relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling:

-

-

-

... More
33 kV feeder pannel

2

-

-

... More
Power transformer Pannel (with differential & REF protection)

9

-

-

... More
36kV, 1250A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated motorised isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings

8

-

-

... More
30 kV, 10kA, 1-ph Station Class Lightening Arrester with Surge Counter, mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware etc as required as per technical specifications, approved drawings and scope of the works.

48

-

-

... More
9kV, 10kA, 1-ph Station Class Lightening Arrester with mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware, etc as required as per technical specifications, approved drawings and scope of the works.

36

-

-

... More
12 kV Indoor type control and relay panel as per technical specifications, approved drawings and scope of works:

-

-

-

... More
Indoor type control and relay panel for 11kV, 3phase, 1250 A VCB (Transformer Breaker) consisting of CT ------, PT-----A-meter, volt-meter, Relays & accessories complete as per specifications for transformer breaker protection

10

-

-

... More
Indoor type control and relay panel for 11 KV 3 phase, 1250 A VCB (Feeder Breakers) consisting of CT ------ A-meter, volt-meter, Relays, energy meter (TVM) & accessories complete as per specifications for feeder breaker protection

29

-

-

... More
12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 600-300/5-5 or 300-150/5-5 -3 Nos indoor type Current Transformer, indoor mounting type control panel for bus coupler, control cabling between VCB and indoor control panel and required accessories, bi-metallic clamps, A-meter, volt-meter, 3- phase electronic energy meter, Relay & accessories complete as per specifications for bus coupler protection

4

-

-

... More
30 V, 100 AH Pb Acid battery, battery stand made of teak wood duly painted with anti rusting paint, battery insulators, inter-battery wiring using 30 sqmm, 1.1 kv, copper single core multi strand cable, terminal connectors, & all other accessories and connectors and 30V, 40 Amp. (or as per State practice) Float-cum-Boost Battery Charger with six wave rectification for 440 V, 3 phase, 50 Hz AC Input Supply as per technical specifications, approved drawings and scope of works

5

-

-

... More
415 V, ACDB along with three phase-neutral voltmeter, three phase ammeter and Selector switches, 200 Amps TPN switch fuse unit as incomer, 32 Amps TPN switches as outgoing feeders suited for number of control panels, nos of VCB kiosk panel, having 20% spare outgoing feeders, mounting arrangements etc as per technical specifications, approved drawings and scope of works.

2

-

-

... More
ACSR Conductor for Bus-Bars & Jumpers/Droppers/Terminations including hardware fittings, hardware, T-claimp etc as per technical specifications, approved drawings and scope of works

-

-

-

... More
30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther

0.6

-

-

... More
Earthing & Grounding conductor as per Approved Electrical Layout for each sub-station as per technical specifications, approved drawings and scope of works with

-

-

-

... More
65 x 8 mm GI flat for ground mat

3

-

-

... More
50 x 6 mm Galvanized GI flat (risers)

0.76

-

-

... More
25mm dia GI rod 3 m long for earth mat

70

-

-

... More
50 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover, placed on GI frame, bantonide powder and other accessories complete as per technical specification. (for Power Transformer Neutral, Station Transformer Neutral and Lightening Arresters direct earthing) as per technical specifications, approved drawings and scope of works.

54

-

-

... More
33 KV Post insulators along with Strurcture, suitable hardware & accessories suitable for Panther/Dog conductors as per approved drawings & specifications.

3

-

-

... More
Control cables including their termination materials like glands, lugs etc. as per technical specifications, approved drawings and scope of the work.

-

-

-

... More
2 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

150

-

-

... More
12 Core 4.0 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

330

-

-

... More
10 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

100

-

-

... More
12 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

800

-

-

... More
2 Core 4.0 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

20

-

-

... More
1 Core 240 sqmm XLPE Cable FRLS

2.5

-

-

... More
11 kV Isolator motorised (12 kV, 630A, 25 kA with Earthswitch outdoor)

17

-

-

... More
11.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56.

6

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to IS 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size)

6

-

-

... More
MS Channel Iron and MS Angle Iron

0.73

-

-

... More
Extension of 33kV bay

-

-

-

... More
RS Joists size 12800x250x125, 7 Nos.

7

-

-

... More
MS Channel Iron 125x65x6, X-Arms @ 12.1 kg/m, 7 mtr long, 5.5 mtr long

273

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated)(with flat and spring washers)]

0.35

-

-

... More
Bus Bar

-

-

-

... More
i) 33 kV Disc Insulator Tension String complete

42

-

-

... More
ii) 33 kV Disc Suspension Tension String complete

24

-

-

... More
ACSR Conductor 200sqmm @ 10%

250

-

-

... More
PG Clamps

42

-

-

... More
Sub Station Automation System ( SCADA) i/c ADSS OFC 06 Pair /12 Core (about 3.5 Km) with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments, UPS having capacity of 02 KVA with 1 hour Battery backup for complete control, monitoring and data logging of 33/11KV Sarabai sub-station from 33/11KV Bhuntar Sub-Station

1

-

-

... More
New 11KV HT Line

-

-

-

... More
Support for 11 KV overhead line as per technical specification, approved drawings and scope of work

-

-

-

... More
11.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56

4952

-

-

... More
10.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-'A') as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-47

198

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

5150

-

-

... More
Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, transformer mounting structure etc made of MS Channels (100x50x6mm), MS angle (65x65x6mm), MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.

189.73

-

-

... More
MS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.

10.6

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

7272

-

-

... More
Insulator and hardware as per technical specification, approved drawings and scope of work.

-

-

-

... More
11 KV Disc insulator B&S type conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 255 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavily polluted atmospheres Creepage distance 400 mm

6570

-

-

... More
11 kV Pin Insulator Brown Glazed Porcelain insulator alongwith GI Pin confirming to IS-731/1971 or latest version thereof with minimum and maximum creepage distance distance & duly fitted with lead/zinc thimble suitable for use with GI forged pin having small steel head as per IS:2486 (Part-I & II) of 1993 & latest amendment if any. Moderately polluted atmospheres Creepage distance- 320mm

15350

-

-

... More
Earthing arrangement as per technical specificatons, approved drawings and scope of work.

-

-

-

... More
HT Earthing set (REC Construction Standard J-1)

3980

-

-

... More
8 SWG GI wire, GI nuts, bolts & washers for earthing and guarding

37.3

-

-

... More
ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work

-

-

-

... More
6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit

1097.94

-

-

... More
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

436

-

-

... More
11 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings

196

-

-

... More
Danger Plate Size: 250x200x1.6 mm made of mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and signal red colour on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to IS specifiction no. IS-1351/1982 suitable for 11KV

4080

-

-

... More
Eye Hook for earth wire

3970

-

-

... More
Galvanised steel barbed wire of 9.8 kg /100metre

15.2

-

-

... More
Aluminium Paint for all poles and steel fitting

5150

-

-

... More
Red Oxide

4633

-

-

... More
New 22KV HT Line

-

-

-

... More
Support for 22KV overhead line as per technical specification, approved drawings and scope of work

-

-

-

... More
11.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56

1320

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

1320

-

-

... More
Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, transformer mounting structure etc made of MS Channels (100x50x6mm), MS angle (65x65x6mm), MS flats (50x6mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.

50

-

-

... More
MS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.

2.46

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

1760

-

-

... More
Insulator and hardware as per technical specification, approved drawings and scope of work.

-

-

-

... More
22 KV Disc insulator B&S type ( 2 nos. disc) conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 225 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavily polluted atmospheres Creepage distance 400 mm

1590

-

-

... More
22 kV Pin Insulator Brown Glazed Porcelain insulator alongwith GI Pin confirming to IS-731/1971 or latest version thereof with minimum and maximum creepage distance distance & duly fitted with lead/zinc thimble suitable for use with GI forged pin having small steel head as per IS:2486 (Part-I & II) of 1993 & latest amendment if any. Moderately polluted atmospheres Creepage Distance- 560mm

2900

-

-

... More
Earthing arrangement as per technical specificatons, approved drawings and scope of work.

-

-

-

... More
HT Earthing set (REC Construction Standard J-1)

970

-

-

... More
8 SWG GI wire, GI nuts, bolts & washers for earthing and guarding

9.06

-

-

... More
ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work

-

-

-

... More
6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit

267

-

-

... More
22 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

91

-

-

... More
22 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings

91

-

-

... More
Danger Plate Size: 250x200x1.6 mm made of mild steel plates 1.6 (minimum) thick vitreous enameled white letter figure, conventional skill and X-Boxes and signal red colour on front side for use in HPSEBL. The rear side of the plate shall be black enameled and conforming to IS specifiction no. IS-1351/1982 suitable for 22KV

968

-

-

... More
Eye Hook for earth wire

91

-

-

... More
Galvanised steel barbed wire of 9.8 kg /100metre

2.73

-

-

... More
Aluminium Paint for all poles and steel fitting

364

-

-

... More
Red Oxide

273

-

-

... More
Augmentation / Reconductoring of LT Lines -1 phase to 3-phase with 50 Sq. mm Rabbit conductor

-

-

-

... More
ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work

-

-

-

... More
ACSR Conductor 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit

443.4

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32

515

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

515

-

-

... More
Shackle Insulator (16 kN)

7400

-

-

... More
D-Iron (U- Clamps)

7400

-

-

... More
Earth Knob

515

-

-

... More
LT Stay Set

440

-

-

... More
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)

2.64

-

-

... More
Full Clamps for 1 No for Stay Set

440

-

-

... More
Earthing Set complete

102

-

-

... More
Spool Tie

7400

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

2.3

-

-

... More
Aluminium Paint

515

-

-

... More
Spiral PVC Spacer

6576

-

-

... More
Red Oxide

460

-

-

... More
Augmentation / Reconductoring of LT Lines -2phase to 3-phase with 50 Sq. mm Rabbit conductor

-

-

-

... More
ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work

-

-

-

... More
ACSR Conductor 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit

57.57

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32

125

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

125

-

-

... More
Shackle Insulator (16 kN)

1210

-

-

... More
D-Iron (U- Clamps)

1210

-

-

... More
Earth Knob

125

-

-

... More
LT Stay Set

115

-

-

... More
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)

0.74

-

-

... More
Full Clamps 1 No for Stay Set

115

-

-

... More
Earthing Set complete

27

-

-

... More
Spool Tie

1210

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.29

-

-

... More
Aluminium Paint

125

-

-

... More
Spiral PVC Spacer

1710

-

-

... More
Red Oxide

113

-

-

... More
Reconductoring of LT Lines -1 phase 2 wire with 50 Sq. mm Rabbit conductor ( 1phase 2 wire = 45 kms)

-

-

-

... More
ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work

-

-

-

... More
ACSR Conductors 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit

90.9

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32

90

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

90

-

-

... More
Shackle Insulator (16 kN)

200

-

-

... More
D-Iron (U- Clamps)

200

-

-

... More
Earth Knob

90

-

-

... More
LT Stay Set

70

-

-

... More
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)

0.42

-

-

... More
Full Clamps 1 No for Stay Set

70

-

-

... More
Earthing Set complete

10

-

-

... More
Spool Tie

200

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.25

-

-

... More
Aluminium Paint

90

-

-

... More
Spiral PVC Spacer

50

-

-

... More
Red Oxide

81

-

-

... More
Reconductoring of LT Lines -3 phase 4 wire with 50 Sq. mm Rabbit conductor

-

-

-

... More
ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamp, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work

-

-

-

... More
ACSR Conductors 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit

206.04

-

-

... More
ACSR Conductors 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog

121.2

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32

162

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

162

-

-

... More
Shackle Insulator (16 kN)

700

-

-

... More
D-Iron (U- Clamps)

700

-

-

... More
Earth Knob

162

-

-

... More
LT Stay Set

145

-

-

... More
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)

0.93

-

-

... More
Full Clamps 1 No for Stay Set

162

-

-

... More
Earthing Set complete

55

-

-

... More
Spool Tie

700

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.35

-

-

... More
Aluminium Paint

162

-

-

... More
Spiral PVC Spacer

330

-

-

... More
Red Oxide

146

-

-

... More
Cabling of LT line with AB Cable

-

-

-

... More
LT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)

-

-

-

... More
LT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)

43.94

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

870

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

870

-

-

... More
Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work.

870

-

-

... More
Full Clamp for stay

870

-

-

... More
Anchoring Assembly for LT

470

-

-

... More
Suspension Assembly for LT

400

-

-

... More
Facade Hooks for LT

870

-

-

... More
Distribution Boxes

500

-

-

... More
T-Jointing kit

290

-

-

... More
LT Earthing set complete (preferbly coil earthing)

174

-

-

... More
Red Oxide

870

-

-

... More
Aluminium paint

870

-

-

2000

-

-

... More
PVC 3.5 Core 16 sqmm

3

-

-

... More
LT ,AB Cable 3x185 Sq. mm {additional 1% sagging & wastage)

-

-

-

... More
LT ,AB Cable 3x185 Sq. mm

22.73

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

743

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

743

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

743

-

-

... More
Full Clamp for stay

743

-

-

... More
X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm]

4.26

-

-

... More
Half Clamp for Cross Arm

743

-

-

... More
Anchoring Assembly for LT

758

-

-

... More
Suspension Assembly for LT

730

-

-

... More
Facade Hooks for LT

1238

-

-

... More
T-Jointing kit

90

-

-

... More
LT Earthing set complete (preferbly coil earthing)

270

-

-

... More
Red Oxide

669

-

-

... More
Aluminium paint

743

-

-

... More
Distribution Boxes

380

-

-

1440

-

-

... More
PVC 3.5 Core 16 sqmm

2.55

-

-

... More
HT ,AB Cable 3x95 Sq. mm {additional 1% sagging & wastage)

-

-

-

... More
11 kV HT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)

6.97

-

-

... More
22 kV HT AB Cable on poles [Size: (3x95 Sq, mm ) {additional 1% sagging & wastage)

13.13

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

660

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

660

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

660

-

-

... More
Pre-fabricated steel items like cross arm, clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm) as per technical specification, approved drawings and scope of work.

1.32

-

-

... More
Anchoring Assembly for HT

677

-

-

... More
Suspension Assembly for HT

637

-

-

... More
Facade Hooks for HT

660

-

-

... More
Heat Shrinkable Straight Through Jointing Kit suitable for 11 kV Cable Size (3x95)

15

-

-

... More
Heat Shrinkable Straight Through Jointing Kit suitable for 22 kV Cable Size (3x95)

26

-

-

... More
Cable Termination kit suitable for 11 kV Cable Size (3x95)

28

-

-

... More
Cable Termination kit suitable for 22 kV Cable Size (3x95)

52

-

-

... More
T-Jointing kit

80

-

-

... More
HT Earthing set complete (preferbly coil earthing)

660

-

-

... More
Red Oxide

594

-

-

... More
Aluminium paint

660

-

-

... More
HT XLPE Cable 3x120 Sq. mm {additional 1% sagging & wastage)

-

-

-

... More
HT XLPE Cable on poles [Size: (3x120 Sq, mm ) {additional 1% sagging & wastage)

2.02

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

66

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

66

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

66

-

-

... More
Pre-fabricated steel items like cross arm, clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm), MS angle (750x50x50x6mm), MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.

0.48

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.07

-

-

... More
Heat Shrinkable Straight Through Jointing Kit

5

-

-

... More
Cable Termination kit

10

-

-

... More
HT Earthing set complete (preferbly coil earthing)

66

-

-

... More
Red Oxide

60

-

-

... More
Aluminium paint

66

-

-

... More
Steel Rope of suitable size for holding of XLPE Cable 3x120 sqmm alongwith fixing clamps and allied material.

2.02

-

-

... More
HT AB Cable on poles [Size: (3x185 Sq, mm ) {additional 1% sagging & wastage)

-

-

-

... More
11 kV AB Cable Size: (3x185 mm²) {additional 1% sagging & wastage)

27.27

-

-

... More
22 kV AB Cable Size: (3x185 mm²) {additional 1% sagging & wastage)

20.2

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

1551

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

1551

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

1551

-

-

... More
Pre-fabricated steel items like cross arm, clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm) as per technical specification, approved drawings and scope of work.

8.89

-

-

... More
Anchoring Assembly for HT

1551

-

-

... More
Suspension Assembly for HT

1551

-

-

... More
Facade Hooks for HT

1620

-

-

... More
Heat Shrinkable Straight Through Jointing Kit

95

-

-

... More
Cable Termination kit

190

-

-

... More
T-Jointing kit

188

-

-

... More
HT Earthing set complete (preferbly coil earthing)

1551

-

-

... More
Red Oxide

1396

-

-

... More
Aluminium paint

1551

-

-

... More
HT AB /xlpe Cable on poles [Size: (3x240 Sq, mm ) {additional 1% sagging & wastage)

-

-

-

... More
11 kV XLPE Cable 3C, AL-Armoured on poles [Size: (3x240 mm²) Cables {additional 1% sagging & wastage)

4.04

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

132

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

132

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

132

-

-

... More
Pre-fabricated steel items like cross arm, clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm), MS angle (750x50x50x6mm), MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.

1.38

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.13

-

-

... More
Heat Shrinkable Straight Through Jointing Kit

16

-

-

... More
Cable Termination kit

19

-

-

... More
HT Earthing set complete (preferbly coil earthing)

132

-

-

... More
Red Oxide

120

-

-

... More
Aluminium paint

132

-

-

... More
Steel Rope of suitable size for holding of XLPE Cable 3x240 sqmm alongwith fixing clamps and allied material.

4.04

-

-

... More
New HT line on 11mts. Steel tublar pole with 11 kV XLPE Cable 3x185 Sq. mm as per Scope of Work

-

-

-

... More
11 kV XLPE Cable 3C, AL-Armoured on poles [Size: (3x185 mm²) Cables {additional 1% sagging & wastage)

27.27

-

-

... More
9.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-32.

891

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

891

-

-

... More
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.

891

-

-

... More
Pre-fabricated steel items like cross arm, clamps, Knee-Bracings, belts,back clamp etc. made of MS Channels (600x100x50x6mm), MS angle (750x50x50x6mm), MS flats (50x6 mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.

9.52

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.8

-

-

... More
Heat Shrinkable Straight Through Jointing Kit

54

-

-

... More
Cable Termination kit

108

-

-

... More
HT Earthing set complete (preferbly coil earthing)

891

-

-

... More
Red Oxide

802

-

-

... More
Aluminium paint

891

-

-

... More
Steel Rope of suitable size for holding of XLPE Cable 3x185 sqmm alongwith fixing clamps and allied material.

27.27

-

-

... More
New 33KV HT line on 11mts. Steel tublar pole with XLPE Cable 1x300 Sq. mm as per Scope of Work

-

-

-

... More
33 kV XLPE Cable on poles [Size: (1x300 mm²) {additional 1% sagging & wastage)

16.16

-

-

... More
11.00 Mtr. Long ISI marked swaged steel tubular pole as per IS: 2713/1980 (Part-II) as amended from time to time, along with Cap Welded on top & Cast iron Base plate of designation 410SP-56

264

-

-

... More
RCC pipe (Muff) ISI marked suitable for different sizes of steel poles. 2000 mm in length and 25 mm thick with 250 mm internal dia duly fabricated by using un-galvanized MS wires of 12 SWG rings and 6 mm MS round in vertical direction conforming to ISI 458-1988 or latest version if any including cement concrete filling 1:3:6 (1 cement : 3 sand : 6 aggrigate 20 mm nominal size).

264

-

-

... More
Pre-fabricated steel items like cross arm, clamps, cross bracings, belts,back clamp etc. made of MS Channels (100x50x6mm), MS angle (65x65x6mm), (50x50x6 mm) MS flats (65x8mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.

17.5

-

-

... More
Stay Sets suitable for 33 kV Line made of MS Round 20 mm dia of 2000mm in length threaded upto 400 mm on one end with one nut and one check nut to avoid slippage an eye of 50 mm dia on other side and welded confirming to REC Specification, Elbow made of MS Channel (100x50x6 mm) and MS Round 20 mm dia vertical height 450 mm, both ends bended after putting in two holes in channel iron taking the ends out 30 mm and welded with channel iron, 2 Nos. Anchors of Angle Iron 65x65x6 mm, 750 mm in length with one whole of 20 mm dia in the centre of each Anchor. The complete stay set shall be painted with superior quality black Japan paint and 7/4.00mm dia GI stranded wire complete with 1 No. guy insulator as per technical specification, approved drawings and scope of work.

264

-

-

... More
33 kV Pin Insulators Brown Glazed Procelain insulator alongwith GI Pin confirming to IS-731/1971 or latest version thereof with minimum and Maximum creepage distance & duly fitted with lead/Zinc thimble suitable for use with GI forged pin having small steel head as per IS: 2486 (Part I & II) of 1993 & latest amendment if any moderately polluted atmoshpheres Creepage distance -840mm

16

-

-

... More
Disc insulator B&S type conformimg to IS-731/1971 all latest version thereof for suspension & tension string ball and socket type having pin ball. The minumum and maximum creepage distance with diameter of insulator- 255 mm & having electromechanical strength 90KN. The insulator shall have W type phosphors bronze security clips for ball socket porcelain conforming IS: 2486-1971 (90KN) complete in all respect. Heavily polluted atmospheres Creepage distance 400 mm

32

-

-

... More
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]

0.8

-

-

... More
Heat Shrinkable Straight Through Jointing Kit

16

-

-

... More
Cable Termination kit

32

-

-

... More
HT Earthing set complete (preferbly coil earthing)

132

-

-

... More
Red Oxide

264

-

-

... More
Aluminium paint

264

-

-

... More
Steel Rope of suitable size for holding of XLPE Cable 1x300 sqmm alongwith fixing clamps and allied material.

16.16

-

-

... More
SCHEDULE -II (Installation Services and Civil Works)

-

-

-

... More
Complete Survey of Division wise Scope of Work i.e. preliminary, actual surveying profiling and final survey, stacking of materials, camp shifting etc. complete job

-

-

-

... More
Electrical Division Kullu

1

-

-

... More
Electrical Division Manali

1

-

-

... More
Electrical Division Thalout

1

-

-

... More
Electrical Division Anni

1

-

-

... More
New DTR 11/22 kV (HVDS, Feeder Bifurcation, Feeder Segregation and Extension of New HT, DT, LT as per technical specification, approved drawings and scope of work.

-

-

-

... More
Erection of 16KVA 11/0.2KV DTR, complete viz digging of pit for poles & earthing (2 No. for pole & 3 no. for earthing), Drilling of holes in X arms & poles Prepration of plateform structure member CI, AI i.e. X-arm & Knee bracing set, Erection of Double Pole Structure, Concreting of RCC Muffs , Erection of plateform, Erection of x-arms, Erection of G.O. Switch, Erection of Drop-Out Fuse Unit, Erection of Lightning arrestor, Erection of LT Box, Providing Earthing connection including G.I.Wire to G.O Switch, Transformer, Lightning arrestor, etc , Erection of 4 Nos. Stay set , Erection of Jumper, Pipe Earthing 3 No. sets , Laying of LT Cable, Barbed wire & painting complete in all respect

47

-

-

... More
Erection of 25KVA, 63KVA, 100KVA & 250KVA , 11/0.433KV & 22/0.4KV DTR, complete viz digging of pit for poles & earthing (2 No. for pole & 3 no. for earthing), Drilling of holes in X arms & poles Prepration of plateform structure member CI, AI i.e. X-arm & Knee bracing set, Erection of Double Pole Structure, Concreting of RCC Muffs , Erection of plateform, Erection of x-arms, Erection of G.O. Switch, Erection of Drop-Out Fuse Unit, Erection of Lightning arrestor, Erection of LT Box, Providing Earthing connection including G.I.Wire to G.O Switch, Transformer, Lightning arrestor, etc , Erection of 4 Nos. Stay set , Erection of Jumper, Pipe Earthing 3 No. sets , Laying of LT Cable, Barbed wire & painting complete in all respect

431

-

-

... More
Erection of 400KVA , 630KVA 11/0.433KV DTR, complete viz digging of pit for poles & earthing (2 No. for pole & 3 no. for earthing), Drilling of holes in X arms & poles Prepration of plateform structure member CI, AI i.e. X-arm & Knee bracing set, Erection of Double Pole Structure, Concreting of RCC Muffs , Erection of plateform, Erection of x-arms, Erection of G.O. Switch, Erection of Drop-Out Fuse Unit, Erection of Lightning arrestor, Erection of LT Box, Providing Earthing connection including G.I.Wire to G.O Switch, Transformer, Lightning arrestor, etc , Erection of 4 Nos. Stay set , Erection of Jumper, Pipe Earthing 3 No. sets , Laying of LT Cable, Barbed wire & painting complete in all respect

20

-

-

... More
Erection of New LT Line

-

-

-

... More
Support for LT overhead Line as per technical specification, approved drawings and scope of work.

-

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

447

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) i/c jumpering etc. Complete

117.79

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

447

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

179

-

-

... More
Laying, stringing , sagging & binding of GI wire 8SWG

29.75

-

-

... More
Augmentation & Renovation of 11/0.4 kV Distribution Transformer Substation

-

-

-

... More
Augmentation of Distribution Transformer Substation using new outdoor type, oil immersed, distribution transformer up to and including 630 KVA as per IS1180 (Part-1): 2014 and its amendments 1, 2, 3 and 4, CRGO/Amorphous core, Energy Efficiency Level 1, carrying Bureau of Indian Standard Certificate mark, in following preferred ratings as per detailed scope of work and technical specifications under:

-

-

-

... More
Dismantling of old 25KVA, 63,100, 250KVA DTR a/w LT Box, meter & cable And Erection of new 63, 100, 250KVA DTR a/w LT Box, meter & cable and transportation of Dismantled material from site of work to concerned Divisional store

453

-

-

... More
Dismantling of old 250KVA, 400KVA DTR a/w LT Box, meter & cable And Erection of new 400KVA, 630KVA DTR a/w LT Box, meter & cable and transportation of Dismantled material from site of work to concerned Divisional store

54

-

-

... More
Renovation of DTR substation Earthing as per technical specification, approved drawings and scope of work:

-

-

-

... More
Revamping of Distribution Transformer substation earthing by using 40 mm dia 3 meter long GI pipe earthing, using 50x6 mm GS flat for earth mat and riser and 25x3mm GS flat for connecting equipment, using 200 kg bentonite powder of substation in normal soil

111

-

-

... More
Augmentation of DTR substation by new Pre-fabricated galvanised steel items like DC cross arm (100x50x6 mm), back clamps (65x8 mm), pole clamp (65x8 mm), DO mounting channel (75x40x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work.

3.78

-

-

... More
Augmentation of DTR substation by new Galvanised Steel (GS) Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.

0.81

-

-

... More
Augmentation of DTR substation by new Polymer/ Porcelain Insulators with hardware fittings, hardware etc as required as per technical specification, approved drawings and scope of work.

-

-

-

... More
Augmentation of DTR substation by new 9KV, 11 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work.

1119

-

-

... More
Augmentation of DTR substation by 18 kV, 10 kA Porcelain Station Surge Arrestor/Lightening Arrestor complete with accessories for 22 KV system

200

-

-

... More
Augmentation of DTR substation by new 11 kV, 3-ph, 400 A, 3 Pin type, Vertical Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

248

-

-

... More
Augmentation of DTR substation by new 22 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type (as desired by DISCOM), Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

50

-

-

... More
11kV, 200 A, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.

128

-

-

... More
22 kV, 3-ph, Drop Out fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings

50

-

-

... More
Conversion of existing LT bare conductor line with following arrangements using new areal bunched XLPE cable,tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, 16 mm dia MS nuts & bolts, pole clamps, spring loaded bus bar suitable for single phase and three phase systems etc. as required as per technical specification, approved drawings and scope of work:

-

-

-

... More
AERIAL BUNCHED XLPE CABLE 3 X 70+50+16 SQ.MM

-

-

-

... More
Laying, Installtion of Suspension & Tension assembly etc., Sagging of LT AB Cable of size: 3 X 70+50+16 sqmm, jointing and termination kits etc. complete

31

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

620

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

600

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

160

-

-

... More
Erection of LT Distibution box complete

160

-

-

... More
Augmentation of 33/11 KV Fully outdoor type substation

-

-

-

... More
Erection of 33/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type Power Transformer along with transformer oil, Buchholtz relay, breather, OTI & WTI, Marshalling Box, Conservator tank, oil level indicator, valves, 2 sets of 50x8 mm GS Neutral Earthing strips {(with braided conductor on bushing end), isolating link, isolation with insulators}, Vent explosion plug, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, LV/HV bushing etc as required as per technical specifications, approved drawings and scope of the work.

-

-

-

... More
3.15 MVA without tap changer

2

-

-

... More
6.30 MVA with off load tap changer

8

-

-

... More
10.0 MVA with on load tap changer

3

-

-

... More
Erection of 33KV gantries structure and equipment structure for mounting Isolators and post insulators.

1

-

-

... More
Erection of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker along with 36kV, 1-Phase, 25kA/3 seconds, 200-100/5-5 Amps or 300-150/5-5 Amps 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1-phase CTs), Jumpers, earthing, supporting structures, bi- metallic clamps, permanent maintenance platform, marshalling box etc required as per technical specifications, scope of works and approved drawings

8

-

-

... More
Erection of 33kV, Indoor, Control & Relay panel along with E/F & O/C relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc as per approved drawings, specifications and scope of works controlling:

-

-

-

... More
33 kV feeder pannel

2

-

-

... More
Power transformer Pannel (with differential & REF protection)

9

-

-

... More
Erection of 36kV, 1250A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated motorised isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings

8

-

-

... More
Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester with Surge Counter, mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware etc as required as per technical specifications, approved drawings and scope of the works.

48

-

-

... More
Erection of 9kV, 10kA, 1-ph Station Class Lightening Arrester with mounting platform, jumpering from bus bar, earthing connection using 50x6mm GS flat, hardware, etc as required as per technical specifications, approved drawings and scope of the works.

36

-

-

... More
Erection of 12 kV Indoor type control and relay panel as per technical specifications, approved drawings and scope of works:

-

-

-

... More
Indoor type control and relay panel for 11kV, 3phase, 1250 A VCB (Transformer Breaker) consisting of CT ------, PT-----A-meter, volt-meter, Relays & accessories complete as per specifications for transformer breaker protection

10

-

-

... More
Indoor type control and relay panel for 11 KV 3 phase, 1250 A VCB (Feeder Breakers) consisting of CT ------ A-meter, volt-meter, Relays, energy meter (TVM) & accessories complete as per specifications for feeder breaker protection

29

-

-

... More
12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 600-300/5-5 or 300-150/5-5 -3 Nos indoor type Current Transformer, indoor mounting type control panel for bus coupler, control cabling between VCB and indoor control panel and required accessories, bi-metallic clamps, A-meter, volt-meter, 3- phase electronic energy meter, Relay & accessories complete as per specifications for bus coupler protection

4

-

-

... More
Erection of 30 V, 100 AH Pb Acid battery, battery stand made of teak wood duly painted with anti rusting paint, battery insulators, inter-battery wiring using 30 sqmm, 1.1 kv, copper single core multi strand cable, terminal connectors, & all other accessories and connectors and 30V, 40 Amp. (or as per State practice) Float-cum-Boost Battery Charger with six wave rectification for 440 V, 3 phase, 50 Hz AC Input Supply as per technical specifications, approved drawings and scope of works

5

-

-

... More
Erection of 415 V, ACDB along with three phase-neutral voltmeter, three phase ammeter and Selector switches, 200 Amps TPN switch fuse unit as incomer, 32 Amps TPN switches as outgoing feeders suited for number of control panels, nos of VCB kiosk panel, having 20% spare outgoing feeders, mounting arrangements etc as per technical specifications, approved drawings and scope of works.

2

-

-

... More
Erection of ACSR Conductor for Bus-Bars & Jumpers/Droppers/Terminations including hardware fittings, hardware, T-claimp, X-arms etc. .

1

-

-

... More
Erection of Earthing & Grounding conductor for each sub-station including GI flat for ground mat 65 x 8 mm, 50 x 6 mm Galvanized GI flat (risers) and 25mm dia GI rod 3 m long for earth mat

1

-

-

... More
Erection of 25mm dia GI rod 3 m long for earth mat

70

-

-

... More
Erection of 50 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover, placed on GI frame, bantonide powder and other accessories complete as per technical specification or Power Transformer Neutral, Station Transformer Neutral and Lightening Arresters direct earthing.

54

-

-

... More
Erection of 33 KV Post insulators along with Strurcture, suitable hardware & accessories suitable for Panther/Dog conductors as per approved drawings & specifications.

3

-

-

... More
Laying and Termination of Control cables of following sizes including their termination materials like glands, lugs etc. complete.

-

-

-

... More
2 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

150

-

-

... More
12 Core 4.0 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

330

-

-

... More
10 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

100

-

-

... More
12 Core 2.5 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

800

-

-

... More
2 Core 4.0 sqmm armoured, stranded copper conductor, PVC insulated and PVC sheathed cable

20

-

-

... More
1 Core 240 sqmm XLPE Cable FRLS

2.5

-

-

... More
Erection of 11 kV Isolator motorised (12 kV, 630A, 25 kA with Earthswitch outdoor)

17

-

-

... More
Erection of steel tubular poles 11 mtr long viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms ,Insulators etc. Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

6

-

-

... More
Erection of 33kV bay viz X-Arms, Nut & Bolts, Bus-bar, Insulators tension and string type i/c erection of conductor, PG Clamps etc.complete job.

1

-

-

... More
Sub Station Automation System ( SCADA) i/c ADSS OFC 06 Pair /12 Core (about 3.5 Km) with necessary hardware and software and any modification/retro-fitting in existing control and monitoring system of 33KV/11KV switch gears and equipments, UPS having capacity of 02 KVA with 1 hour Battery backup for complete control, monitoring and data logging of 33/11KV Sarabai sub-station from 33/11KV Bhuntar Sub-Station

1

-

-

... More
Erection of New 11KV HT Line

-

-

-

... More
Support for 11 KV overhead line as per technical specification, approved drawings and scope of work

-

-

-

... More
Erection of steel tubular pole 10/11 mtr long for HT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and fixing of Insulators, knee bracing set, X-bracing set , Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete in all respect (Punching of the poles is stricitly not allowed)

5150

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) i/c jumpering etc. Complete

1097.94

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

7272

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

3980

-

-

... More
Laying, stringing , sagging & binding of GI wire 8SWG

365.98

-

-

... More
Erection of 11 kV, 3-ph,400 A, 3 Pin type, Vertical Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

436

-

-

... More
11kV, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.

196

-

-

... More
Erection of New 22KV HT Line

-

-

-

... More
Support for 22KV overhead line as per technical specification, approved drawings and scope of work

-

-

-

... More
Erection of steel tubular pole 11 mtr long for HT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and fixing of Insulators, knee bracing set, X-bracing set , Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete in all respect (Punching of the poles is stricitly not allowed)

1320

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) i/c jumpering etc. Complete

267

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

1760

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

970

-

-

... More
Laying, stringing , sagging & binding of GI wire 8SWG

89

-

-

... More
Erection of 11 kV, 3-ph,400 A, 3 Pin type, Vertical Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings

91

-

-

... More
11kV, 3-ph Drop Out fuse assembly including insulators and mounting arrangements, jumpering from bus bar, hardware, etc as required as per technical specifications, approved drawings and scope of the works.

91

-

-

... More
Augmentation / Reconductoring of LT Lines -1 phase to 3-phase with 50 Sq. mm Rabbit conductor

-

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

515

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) i/c jumpering etc. Complete

443.4

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

440

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

102

-

-

... More
Augmentation / Reconductoring of LT Lines -2phase to 3-phase with 50 Sq. mm Rabbit conductor

-

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

125

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) i/c jumpering etc. Complete

57.57

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

115

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

27

-

-

... More
Reconductoring of LT Lines -1 phase 2 wire with 50 Sq. mm Rabbit conductor ( 1phase 2 wire = 45 kms) by dismantling of old conductor i/c rolling of conductor & lift all dismantled material from site of work to concerned divisional store

-

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

90

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) i/c jumpering etc. Complete

90.9

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

70

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

10

-

-

... More
Reconductoring of LT Lines -3 phase 4 wire with 50 Sq. mm Rabbit conductor by dismantling of old conductor i/c rolling of conductor & lift all dismantled material from site of work to concerned divisional store

-

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms and Shackle Insulators, Filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

162

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/3.35 mm (50mm2) i/c jumpering etc. Complete

206.04

-

-

... More
Laying, stringing , sagging & binding with Insulator of ACSR rabbit conductor of size 6/1/4.72 mm (100mm2) i/c jumpering etc. Complete

121.2

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

145

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

55

-

-

... More
Cabling of LT line with AB Cable

-

-

-

... More
Laying, Installtion of Suspension & Tension assembly etc., Sagging of LT AB Cable of size: 3 X 95 sqmm, jointing and termination kits etc. complete

43.94

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

870

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

870

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

174

-

-

... More
Erection of LT Distibution box complete

500

-

-

... More
Erection of IPC

2000

-

-

... More
Erection of PVC 3.5 Core 16 sqmm

3

-

-

... More
LT ,AB Cable 3x185 Sq. mm {additional 1% sagging & wastage)

-

-

-

... More
Laying, Installtion of Suspension & Tension assembly etc., Sagging of LT AB Cable of size:3x185 Sq. mm, jointing and termination kits etc. complete

22.73

-

-

... More
Erection of steel tubular pole 9mtr long (Single pole) for LT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

743

-

-

... More
Erection of Stay Set LT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

743

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

270

-

-

... More
Erection of LT Distibution box complete

380

-

-

... More
Erection of IPC

1440

-

-

... More
Erection of PVC 3.5 Core 16 sqmm

2.55

-

-

... More
HT ,AB Cable 3x95 Sq. mm {additional 1% sagging & wastage)

-

-

-

... More
Laying, Installation of Suspension & Tension assembly etc., Sagging of 11 kV HT ,AB Cable 3x95 Sq. mm, jointing and termination kits etc. complete

6.97

-

-

... More
Laying, Installation of Suspension & Tension assembly etc., Sagging of 22 kV HT ,AB Cable 3x95 Sq. mm, jointing and termination kits etc. Complete

13.13

-

-

... More
Erection of steel tubular pole 9mtr long for HT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

660

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

230

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

660

-

-

... More
HT XLPE Cable 3x120 Sq. mm {additional 1% sagging & wastage)

-

-

-

... More
Laying, installation of Suspension & Tension assembly etc., Sagging of HT XLPE Cable 3x120 Sq. mm, jointing and termination kits etc. complete

2.02

-

-

... More
Erection of steel tubular pole 9mtr long for HT Line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & XLPE cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

66

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

66

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

66

-

-

... More
Erection of Steel Rope for holding of XLPE Cable 3x120 sqmm alongwith fixing clamps and allied material.

2.02

-

-

... More
HT AB Cable on poles [Size: (3x185 Sq, mm ) {additional 1% sagging & wastage)

-

-

-

... More
Laying, Installation of Suspension & Tension assembly etc., Sagging of 11 kV HT ,AB Cable 3x185 Sq. mm, jointing and termination kits etc. complete

27.27

-

-

... More
Laying, Installation of Suspension & Tension assembly etc., Sagging of 22 kV HT ,AB Cable 3x185 Sq. mm, jointing and termination kits etc. complete

20.2

-

-

... More
Erection of steel tubular pole 9mtr long for HT line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & AB cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

1551

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

1551

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

1551

-

-

... More
HT AB /xlpe Cable on poles [Size: (3x240 Sq, mm ) {additional 1% sagging & wastage)

-

-

-

... More
Laying, installation of Suspension & Tension assembly etc., Sagging of HT XLPE Cable 3x240 Sq. mm, jointing and termination kits etc. complete

4.04

-

-

... More
Erection of steel tubular pole 9mtr long for HT Line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & XLPE cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

132

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

132

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

132

-

-

... More
Erection of Steel Rope for holding of XLPE Cable 3x240 sqmm alongwith fixing clamps and allied material.

4.04

-

-

... More
New HT line on 11mts. Steel tublar pole with 11 kV XLPE Cable 3x185 Sq. mm as per Scope of Work

-

-

-

... More
Laying, installation of Suspension & Tension assembly etc., Sagging of HT XLPE Cable 3x185 Sq. mm, jointing and termination kits etc. complete

27.27

-

-

... More
Erection of steel tubular pole 9mtr long for HT Line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Erection of X-arms & XLPE cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

891

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

891

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

891

-

-

... More
Erection of Steel Rope for holding of XLPE Cable 3x185 sqmm alongwith fixing clamps and allied material.

27.27

-

-

... More
New 33KV HT line on 11mts. Steel tublar pole with XLPE Cable 1x300 Sq. mm as per Scope of Work

-

-

-

... More
Erection of 33 kV XLPE Cable on poles [Size: (1x300 mm²) viz Laying, installation of Suspension & Tension assembly etc., Sagging of HT XLPE Cable 1x300 Sq. mm, jointing and termination kits etc. complete

16.16

-

-

... More
Erection of steel tubular pole 11 mtr long for HT Line viz digging of pit, Drilling of holes in X-arms, Erection of pole, Cutting, fabrication and drilling of holes in X-Arms and X-Bracing Sets, fixing of X-Arms, fixing of Insulator & XLPE cable fitting, filling of pit & ramming , painting of pole & filling of concrete in RCC muff complete (Punching of the poles is stricitly not allowed)

132

-

-

... More
Erection of Stay Set HT (Digging of pit, fixing of stay rod, filling of pit , nozzeling & tighting)

264

-

-

... More
Erection of Earthing set (Digging of pit, fixing of GI wire to the earth system & filling of pit)

132

-

-

... More
Erection of Steel Rope for holding of XLPE Cable 1x300 sqmm alongwith fixing clamps and allied material.

16.16

-

-

... More
Civil Works

-

-

-

... More
CONSTRUCTION OF FOUNDATION FOR 6.30 MVA TO 10 MVA, 3.15MVA TO 6.3MVA 33/11 KV POWER TRANSFORMER, R.S. JOIST FOUNDATION, FIRE WALL /BAFFLE WALL, EXTENSION OF BUILDING WORKS, OIL SUMP, FOUNDATION & FENCING FOR 250KVA TO 630KVA DTRs, CABLE TRENCHES, DRAINAGE WORK FOUNDATION FOR VCBs & APPROACH ROAD.

-

-

-

... More
Earth work in excavation/cutting in all respect by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.

1457.98

-

-

... More
Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site:-

9

-

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

8.57

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:- 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size).

85.74

-

-

... More
Stone soling

54.32

-

-

... More
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.

41.6

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size).

51.53

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size).

38.29

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :-

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete.

659.12

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers.

46.07

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

30.24

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

8.57

-

-

... More
Edges of slabs and breaks in floors and walls: Under 20 cm. wide.

4881.44

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

2.25

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1844.34

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size).

886.51

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

4282.6

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).

47.64

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Hot rolled deformed bars.

60799.9

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).

9.85

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size).

3.02

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.

69576.66

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes for blow holes in fire protection wall complete in all respect.75/50 mm diameter.

25.2

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 20 mm to 40 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

13.45

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

34.8

-

-

... More
P/f GI pipes complete with GI fittings including trenching anf refilling etc . 100 mm dia nominal bore

182.4

-

-

... More
P/f GI pipes complete with GI fittings including trenching anf refilling etc :- 80mm dia nominal bore

25

-

-

... More
R.C.C. Hume pipe 225 mm dia.

120

-

-

... More
Providing and fixing B.G. (Broad Gauge) Rail as per IRS( Indian Railway Standard )

208

-

-

... More
Supplying and stacking at site:- Bajri Spreading of stone aggregate 40 mm thick.

231.9

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand).

288.72

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).

675.54

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : - Cement mortar 1:4 (1 cement : 4 coarse sand).

13.21

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Sal wood.

0.44

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-incharge. Second class teak wood 35 mm thick shutters.

8.39

-

-

... More
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws:- 35 mm thick shutters , with ISI marked M.S. pressed butt hinges bright finished of required size, Second class teak wood.

5.87

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.

88.8

-

-

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

48

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix:- 1:4 (1 cement: 4 fine sand).

1676.17

-

-

... More
20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand).

93.48

-

-

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand).

35.12

-

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge (SOMANY MAKE).In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand):-Acid and alkali resistant tile.

22.41

-

-

... More
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand):- Acid and alkali resistant tile Cement Slurry.

2.93

-

-

... More
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :3000X16 mm.

100

-

-

... More
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :

-

-

-

... More
200x10 mm

8

-

-

... More
150X10 mm

44

-

-

... More
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete.

-

-

-

... More
125 mm

111

-

-

... More
100 mm

28

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper.

4

-

-

... More
Providing and fixing bright finished brass hard drawn hooks and eyes :150 mm.

11

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

124.79

-

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work.

124.79

-

-

... More
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.

93.48

-

-

... More
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture.

12.21

-

-

... More
Painting with oil type wood preservative of approved brand and manufacture :New work (two or more coats).

31.56

-

-

... More
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture.

31.56

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws.

33.96

-

-

... More
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type.

24

-

-

... More
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.100 mm.

24

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.