Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Machinery and Tools
Eprocure
Opening Date4 Dec 2023
Closing Date16 Dec 2023
Tender Amount₹ 79,95,000 
Notes
Download

Costs

Summary

Replacement Of Old Pumping Machinery Various Water Supply Schemes And Automation Under Ghumarwin Constituency In Tehsil Ghumarwin Distt Bilaspur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and fixing double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm. G.I strips and G.I wire as per IS: 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

-

-

-

... More
Providing and installation of VFD Starter for centrifugal pump with SCADA based Automation

-

-

-

... More
Supply , Installation, Testing and Commissioning of Energy Saving Variable Frequency Starter Panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the suitable rating . Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted with Surge Suppressor Device suiatble to protect against class-1 & 2 surges.

1

-

-

... More
Energy Saving Variable Frequency Starter of suitable rating . Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to monitor & control the frequecy of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: JSV Approved

1

-

-

... More
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc. with RS 485 communication Make:- L&T/Conserve/Schnieder

1

-

-

... More
Main incomer MCCB of suitable capacity of L&T / Schnieder /ABB /Siemens make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

1

-

-

... More
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.

1

-

-

... More
LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc.

1

-

-

... More
Selector Switch for Auto and Manual Operation

1

-

-

... More
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should be proper protection in case of any voltage surge and distortions.

2

-

-

... More
Control Transformer Make: JSV Approved

1

-

-

... More
Power and Control Wiring and Busbar

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.

1

-

-

... More
Power quality monitoring & controlling relay with Control Contactor to safeguard the Electronic & Electric elements

1

-

-

... More
Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KItKat fuses of HPSEB Make: Siemens/Schnieder/L&T/reputed approved make

1

-

-

... More
Supply Installation, Testing and Commissioning of PLC Control Panel with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Siemens/Allen Bredley/reputed approved make

1

-

-

... More
Electronic relay card 8 channel

1

-

-

... More
SMPS 4.5 Amps to energise PLC system

1

-

-

... More
HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make: Bechoff Automation/Roackwell/ reputed approved make

1

-

-

... More
Control MCB for Automation System

1

-

-

... More
Level Sensor to indicate the water level of tank remotely

2

-

-

... More
Shielded Data Cable for Communication of Level Sensor with PLC

1

-

-

... More
Supply of Mobile App (Android/IOS) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users. Make: JSV Approved

1

-

-

... More
Cloud GateWay for Data Clouding to Server

1

-

-

... More
SCADA software to be installed in Laptop/PC to remotely monitor and control the operation of pumps and also to analysis the pump start and stop history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, THD etc Make JSV Approved

1

-

-

... More
Cloud Space for data storage at cloud/server

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
The automation shall alos including provision for depecting the electrical consumption along with amount analugus/ equivaleint to bill generated by HPSEBL.( Note : If any item is missing in pannel board of pump/PLC/ automation required to make the system functional will have to be executed in the above cost and two years maintenance cost is included in the cost of pannel board of pump & automation)

1

-

-

... More
LWSS Bum Pantehra 2nd phase (Karnghui) Providing & Installation of horizontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in series of kirloskar /mather and plat /KSB/crompton make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers of suitable alloys, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to squirrel cage drip proof induction motor of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:- Discharge:-5.89 LPS per set, Total dynamic head :- 214.34 metre,Residual head:- 3 metres, Dia of Rising Main:- 80 mm , Length of Rising Main:- 1460 Rmt, Pumping Hours:- 8 hours, Coupling and base plate :- 1 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade. Suction left (-) tve

80

-

-

... More
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:-Suction pipe 100 mm dia M.C Minimum length= 5 metre Delivery pipe 65 mm dia M.C Minimum length= 10 metre Common header 80 mm dia M.C Minimum length = 10 metre The GMS tube confirming to IS :- 1239-1979 part-I Medium class flanged with MS flanges of table 5 in suction pipe and heavy class flanged with MS flanges of table 17 in delivery side and common header.

1

-

-

... More
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. Motor side: suitable capacity Min length = 20 mtrs. Supply side: suitable capacity Min. length =10 mtrs.

-

-

-

... More
Providing and fixing double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm. G.I strips and G.I wire as per IS: 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

-

-

-

... More
Providing and instalation of VFD Starter for centrifugal pump with SCADA based Automation

-

-

-

... More
Supply , Installation, Testing and Commissioning of Energy Saving Variable Frequency Starter Panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the suible rating . Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted with Surge Suppressor Device suiatble to protect against class-1 & 2 surges. Make: Aarmation Electric/Tricolite/L S Controls/Adlec

1

-

-

... More
Energy Saving Variable Frequency Starter of suitable rating. Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to monitor & control the frequecy of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: JSV Approved

1

-

-

... More
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc. with RS 485 communication Make:- L&T/Conserve/Schnieder

1

-

-

... More
Main incomer MCCB of suitable capacity of L&T / Schnieder/ABB/Siemens make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

1

-

-

... More
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.

1

-

-

... More
LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc.

1

-

-

... More
Selector Switch for Auto and Manual Operation

1

-

-

... More
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should be proper protection in case of any voltage surge and distortions.

2

-

-

... More
Control Transformer Make: JSV Approved

1

-

-

... More
Power and Control Wiring and Busbar

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.

1

-

-

... More
Power quality monitoring & controlling relay with Control Contactor to safeguard the Electronic & Electric elements

1

-

-

... More
Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KItKat fuses of HPSEB Make: Siemens/Schnieder/L&T/reputed approved make

1

-

-

... More
Supply Installation, Testing and Commissioning of PLC Control Panel with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Siemens/Allen Bredley/reputed approved make

1

-

-

... More
Electronic relay card 8 channel

1

-

-

... More
SMPS 4.5 Amps to energise PLC system

1

-

-

... More
HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make: Bechoff Automation/Roackwell/ reputed approved make

1

-

-

... More
Control MCB for Automation System

1

-

-

... More
Level Sensor to indicate the water level of tank remotely

2

-

-

... More
Shielded Data Cable for Communication of Level Sensor with PLC

1

-

-

... More
Supply of Mobile App (Android/IOS) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users. Make: JSV Approved

1

-

-

... More
Cloud GateWay for Data Clouding to Server

1

-

-

... More
SCADA software to be installed in Laptop/PC to remotely monitor and control the operation of pumps and also to analysis the pump start and stop history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, THD etc Make JSV Approved

1

-

-

... More
Cloud Space for data storage at cloud/server

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
The automation shall also including provision for depecting the electrical consumption along with amount analugus/ equivaleint to bill generated by HPSEBL.(Note:If any item is missing in pannel board of pump/PLC/ automation required to make the system functional will have to be executed in the above cost and two years maintenance cost is included in the cost of pannel board of pump & automation.)

1

-

-

... More
LWSS Badog Badon Providing & Installation of horizontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in Kirloskar/KSB/ mather Platt make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers of suitable alloys, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to squirrel cage drip proof induction motor of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:- Discharge:-5.06 LPS per set, Total dynamic head :- 308.76 metre, Residual head:- 3 metres, Dia of Rising Main:- 80 mm , Length of Rising Main:- 2100 Rmt, Pumping Hours:- 8 hours, Coupling and base plate :- 1 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade. Suction lift (+)ve

120

-

-

... More
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:- Suction pipe 80 mm dia M.C Minimum length= 5 metre Delivery pipe 65 mm dia M.C Minimum length= 10 metre Common header 80 mm dia M.C Minimum length = 10 metre The GMS tube confirming to IS :- 1239-1979 part-I Medium class flanged with MS flanges of table 5 in suction pipe and heavy class flanged with MS flanges of table 17 in delivery side and common header.

1

-

-

... More
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.Motor side: suitable capacity Min length = 20 mtrs. Supply side: suitable capacity Min. length =10 mtrs.

-

-

-

... More
Providing and fixing double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm. G.I strips and G.I wire as per IS: 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

-

-

-

... More
Providing and instalation of VFD Starter for centrifugal pump with SCADA based Automation

-

-

-

... More
Supply , Installation, Testing and Commissioning of Energy Saving Variable Frequency Starter Panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the suitable rating . Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted with Surge Suppressor Device suiatble to protect against class-1 & 2 surges. Make: Aarmation Electric/Tricolite/L S Controls/Adlec

1

-

-

... More
Energy Saving Variable Frequency Starter of 60 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to monitor & control the frequecy of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: JSV Approved

1

-

-

... More
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc. with RS 485 communication Make:- L&T/Conserve/Schnieder

1

-

-

... More
Main incomer MCCB of suitable capacity of L&T / Schnieder/ABB/Siemens make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

1

-

-

... More
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.

1

-

-

... More
LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc.

1

-

-

... More
Selector Switch for Auto and Manual Operation

1

-

-

... More
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should be proper protection in case of any voltage surge and distortions.

2

-

-

... More
Control Transformer Make: JSV Approved

1

-

-

... More
Power and Control Wiring and Busbar

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.

1

-

-

... More
Power quality monitoring & controlling relay with Control Contactor to safeguard the Electronic & Electric elements

1

-

-

... More
Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KItKat fuses of HPSEB Make: Siemens/Schnieder/L&T/reputed approved make

1

-

-

... More
Supply Installation, Testing and Commissioning of PLC Control Panel with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Siemens/Allen Bredley/reputed approved make

1

-

-

... More
Electronic relay card 8 channel

1

-

-

... More
SMPS 4.5 Amps to energise PLC system

1

-

-

... More
HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make: Bechoff Automation/Roackwell/ reputed approved make

1

-

-

... More
Control MCB for Automation System

1

-

-

... More
Level Sensor to indicate the water level of tank remotely

2

-

-

... More
Shielded Data Cable for Communication of Level Sensor with PLC

1

-

-

... More
Supply of Mobile App (Android/IOS) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users. Make: JSV Approved

1

-

-

... More
Cloud GateWay for Data Clouding to Server

1

-

-

... More
SCADA software to be installed in Laptop/PC to remotely monitor and control the operation of pumps and also to analysis the pump start and stop history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, THD etc Make JSV Approved

1

-

-

... More
Cloud Space for data storage at cloud/server

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
The automation shall alos including provision for depecting the electrical consumption along with amount analugus/ equivaleint to bill generated by HPSEBL. (Note:If any item is missing in pannel board of pump/PLC/ automation required to make the system functional will have to be executed in the above cost and two years maintenance cost is included in the cost of pannel board of pump & automation.)

1

-

-

... More
LWSS DIARA:Providing & Installation of horizontal spindle horizontal split casing / end suctions (back pull out arrangement ) single /double/multistage centrifugal pump or combination of pump in Mather Platt /Kirloskar /KSB make as per BIS 1520-1980 with up to date amendments, read with IS:9137-1978 or latest edition suitable for lifting clear water . The pump should be fitted with bronze impellers of suitable alloys, priming funnels , casing rings, shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on MS/ Cast steel base plate ( base plate to be provided from the manufacturer,s of the pumping unit only) to squirrel cage drip proof induction motor of standard make such as Kirloskar/Crompton/ BHEL confirming to BIS 9238-1979 latest with up to date amendments and suitable for operation on 400 (+/-) 10% volts, 50 cycles / second, three phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of + 10% and - 15% of the duty point head. The motor should be as per IS 325-1978 with up to date amendments.The pump set should suitable for operation on data given below:- Discharge:- 4.66 LPS per set, Total dynamic head :- 185.52 metre,Residual head:- 3 metres, Dia of Rising Main:- 80 mm , Length of Rising Main:- 2100 Rmt, Pumping Hours:- 8 hours, Coupling and base plate :- 1 sets, Turbidity :- less than 50 NTU, Temprature 20 degree to 45 degree centigrade. Suction Lift (+) ve

60

-

-

... More
Providing and fixing double flanged GMS piping network for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as rappers, flanges, rubber gaskets minimum 3 mm in thickness as per IS 2712-1979, nuts and bolts as per IS:1364-1983, bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as per drawing up to 5 metre away from the outer wall of pump houses. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated.The size of various components are as under:- Suction pipe 100 mm dia M.C Minimum length= 5 metre Delivery pipe 65 mm dia M.C Minimum length= 10 metre Common header 80 mm dia M.C Minimum length = 10 metre The GMS tube confirming to IS :- 1239-1979 part-I Medium class flanged with MS flanges of table 5 in suction pipe and heavy class flanged with MS flanges of table 17 in delivery side and common header.

1

-

-

... More
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/ make from metre of HPSEB to MCB and from MCB to bus bar switch and starter including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.Motor side: suitable capacity Min length = 20 mtrs. Supply side: suitable capacity Min. length =10 mtrs. Providing and fixing double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx3mm. G.I strips and G.I wire as per IS: 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.

-

-

-

... More
Providing and instalation of VFD Starter for centrifugal pump with SCADA based Automation

-

-

-

... More
Supply , Installation, Testing and Commissioning of Energy Saving Variable Frequency Starter Panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the suitable rating . Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted with Surge Suppressor Device suiatble to protect against class-1 & 2 surges. Make: Aarmation Electric/Tricolite/L S Controls/Adlec

1

-

-

... More
Energy Saving Variable Frequency Starter of suitable rating. Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to monitor & control the frequecy of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: JSV Approved

1

-

-

... More
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc. with RS 485 communication Make:- L&T/Conserve/Schnieder

1

-

-

... More
Main incomer MCCB of suitable capacity of L&T / Schnieder/ABB/Siemens make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).

1

-

-

... More
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.

1

-

-

... More
LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc.

1

-

-

... More
Selector Switch for Auto and Manual Operation

1

-

-

... More
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should be proper protection in case of any voltage surge and distortions.

2

-

-

... More
Control Transformer Make: JSV Approved

1

-

-

... More
Power and Control Wiring and Busbar

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.

1

-

-

... More
Power quality monitoring & controlling relay with Control Contactor to safeguard the Electronic & Electric elements

1

-

-

... More
Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KItKat fuses of HPSEB Make: Siemens/Schnieder/L&T/reputed approved make

1

-

-

... More
Supply Installation, Testing and Commissioning of PLC Control Panel with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Siemens/Allen Bredley/reputed approved make

1

-

-

... More
Electronic relay card 8 channel

1

-

-

... More
SMPS 4.5 Amps to energise PLC system

1

-

-

... More
HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make: Bechoff Automation/Roackwell/ reputed approved make

1

-

-

... More
Control MCB for Automation System

1

-

-

... More
Level Sensor to indicate the water level of tank remotely

2

-

-

... More
Shielded Data Cable for Communication of Level Sensor with PLC

1

-

-

... More
Supply of Mobile App (Android/IOS) with User ID and Password to monitor and control the pumping operation from Mobile for 3 users. Make: JSV Approved

1

-

-

... More
Cloud GateWay for Data Clouding to Server

1

-

-

... More
SCADA software to be installed in Laptop/PC to remotely monitor and control the operation of pumps and also to analysis the pump start and stop history logging, fault status, fault history, Power Quality Parameters like PF, Current, Voltage, KWH, THD etc Make JSV Approved

1

-

-

... More
Cloud Space for data storage at cloud/server

1

-

-

... More
Installation, Commissioning and Software Development

1

-

-

... More
The automation shall alos including provision for depecting the electrical consumption along with amount analugus/ equivaleint to bill generated by HPSEBL.(Note:If any item is missing in pannel board of pump/PLC/ automation required to make the system functional will have to be executed in the above cost and two years maintenance cost is included in the cost of pannel board of pump & automation.)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.