Himachal Pradesh Irrigation And Public Health Department Tender

Bidassist allows us to explore new opportunities across the whole world so as to support the growth of the business. It is designed in such a manner that if we need any kind of information about any government e-tender the Himachal Pradesh government has posted on its website, Bidassist provides the same in a very hassle-free manner. As BidAssist is designed as a very user-friendly website which helps us find the specific Himachal Pradesh etender we are looking for.

Himachal Pradesh Irrigation And Public Health Department - HPIPH Tender

Works
Civil And Construction
Machinery and Tools
Water Storage And Supply
Eprocure
Opening Date15 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 11,71,56,635 
Notes
Download

Costs

Summary

Providing Water Treatment Plant To Various Wss For Improving The Quality Of Water Under Shahpur Assembly In Tehsil Shahpur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Design, construction , testing and commissioning of R.C.C trench weir in M 30 grade cement concrete across various Khads as per site condition of 25 meter length and height including depth above and below the natural bed level of khad to obtain required discharge as per proper design requirment including the cost of site development, excavation, cutting and dewatering etc in all kinds of soil. The structural design of trench weir shall strictly confirm to relevent of BIS code and specification. (Refer data sheet No. 1A, 1B and 1C)

3

-

-

... More
Pump House- Survey , Designing, Constructing, Testing & Commissioning (to be approved by the comptent authority) of pump House at following Location including all allied Civil Works , external Electrical work wiring, Sanitary work, excavation in foundation in all kinds of soils, C/O Toilets, C/O Septic Tanks of capacity for required users, internal and external solar powered Street lighting, external landscaping, dewatering including MS rail along longitudinal wall of approved ISI make electrically operated alongwith all alied accessories and painting with asian apex ultima with priming coat and wall putty and fire fighting system complete including site development as directed engineer in charge. the contractor shall provide 3 sets of approved drawing with design and one soft copy to the department complete within all leads and lifts. (Refer data Sheet No. 3)

-

-

-

... More
Pump house at Chari 1 Nos. 62.95 Sqm.

62.95

-

-

... More
Pump house at Rehlu 1 Nos. 62.95 Sqm.

62.95

-

-

... More
Pump house at Salol 1 Nos. 62.95 Sqm.

62.95

-

-

... More
JE Office Cum Quarter- Survey , Designing, Constructing, Testing & Commissioning (to be approved by the comptent authority) of JE office Cum Quarter at Salol Location including all allied Civil Works , external Electrical work wiring, Sanitary work, excavation in foundation in all kinds of soils, C/O Toilets, C/O Septic Tanks of capacity for required users, internal and external solar powered Street lighting, external landscaping,, freniture items reputed / JSV approved make and boundary wall and painting with asian apex ultima with priming coat and wall putty and fire fighting system complete including site development as directed engineer in charge. the contractor shall provide 3 sets of approved drawing with design and one soft copy to the department complete within all leads and lifts.

-

-

-

... More
JE office Cum Quarter at Salol 1 Nos. 85.00 Sqm.

85

-

-

... More
Providing and laying cement concrete 1:4:8 (1 cement: 4sand: 8graded stone agg. 40mm nominal size)and curing complete excluding cost of form work in foundation and plinth within all leads and lifts.

10.04

-

-

... More
Providing and laying cement concrete work 1:2:4 (cement 2sand 4 graded stone aggregate 20mm thick nominal size)and curing complete excluding cost or form work and reinforcement for reinforced work in : foundation & footing basis of columns and the like & mass concrete with in all leads and lifts.

25.91

-

-

... More
In walls any thickness but not less then 0.10 mtrs thickness)i/c attached pillaster buttresses plinth and string courses etc.from top of foundation upto floor two level complete within all leads and lifts.

35.14

-

-

... More
Providing form work with steel plates 3.15mm thick welded with angles iron in frame 30x30x5mm so as to give a fair finish i/c centring, shuttering,strutting and propping etc. with wooden batten and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.height of propping and centring below supporting removal of the same for insitu work in:-Vertical surfaces such as walls(any thickness)bartitions and the like i/c attached,pillasters plinth and string courses and the like within all leads and lifts.

165.44

-

-

... More
Providing mild/ tor steel reinforcement for RCC work I/c bending ,binding and placing in position complete upto floor two level.

3921.81

-

-

... More
Steel work welded in built up sections,trusses and framed work,including cutting ,hoisting ,fixing in position and applying a priming coat of red lead paint:- In grafting, framed, guards, bars, ladders, railing, brackets & similar work within all leads and lifts.

104.32

-

-

... More
Demolition above G.L upto floor two level including stacking of servicable material and disposal of unservicable material within 20 meter leads and including cutting the necessary reinforcement and seperating from R.C.C work/R.B/ Stone Work as per entire satisfaciton of the Engineer - in - Charge.

-

-

-

... More
Rubble Masonary in Cement Motor

22.8

-

-

... More
Brick Work

20.82

-

-

... More
Slab

6.84

-

-

... More
Pumping Machinery Centrifugal :- Supply, Installation, Testing and commissioning of star rated energy efficient horizontal spindle , Horizontal / Radial split casing.end suctions (back pull out arrangement single double multistage cuntrifugal pump suitable "for operation, in parallel of recommended make such as Maker and platt/KSB/Kirloskar/Jyoti/Beaconweir BS&BE confirming toBIS-1520-1980 with upto date ammendments suaitable of lifting clear water for under mentioned characteristics with bronze with priming funels, casing ring and shift slvves of bronze/steel, shaft of SS: 410/AIS 1431 Chrom in plated with cast iron casing coupled directly through a flexible coupling on a Common MS base plate to squirrel cage screen protected drip proof induciton motor/TEFC/CCA of standard make such as Krloskar/Bhel/Crompton/NGEF/GEC/Siemens/Jyoti/ the power of electirc motor/motors should be at least (+) 10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10 % and (-)15 % of the duty point head. the motor/Motors should be as per IS 325-1978 with upto date ammendments read with IS 900-1972 . the starting current of the motor shall be limited to not more than 4.5 to 5 times of full load current. (Refer data sheet No. 4)

-

-

-

... More
Stage 1st ( From Pump House to MST) , Discharge of each working pump = 42.09 LPS, Total Head = 100.57 Mtrs, Numbers of Pumps CIW +IS

1

-

-

... More
Pumping Machinery Centrifugal :- Supply, Installation, Testing and commissioning of star rated energy efficient horizontal spindle , Horizontal / Radial split casing.end suctions (back pull out arrangement single double multistage cuntrifugal pump suitable "for operation, in parallel of recommended make such as Maker and platt/KSB/Kirloskar/Jyoti/Beaconweir BS&BE confirming toBIS-1520-1980 with upto date ammendments suitable for lifting clearwater, for under mentioned characteristics with bronze priming funels, casing ring and shift slvves of bronze/steel, shaft of SS: 410/AIS 1431 Chrom in plated with cast iron casing coupled directly through a flexible coupling on a Common MS base plate to squirrel cage screen protected drip proof induciton motor/TEFC/CCA of standard make such as Krloskar/Bhel/Crompton/NGEF/GEC/Siemens/Jyoti/ area . the power of electirc motor/motors should be at least (+) 10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10 % and (-)15 % of the duty point head. the motor/Motors should be as per IS 325-1978 with upto date ammendments read with IS 900-1972 . the starting current of the motor shall be limited to not more than 4.5 to 5 times of full load current. (Refer data Sheet No. 4)

-

-

-

... More
Stage 1st ( From Pump House to MST) , Discharge of each working pump = 1.23 LPS, Total Head = 201.57 Mtrs, Numbers of Pumps (1 W +1 S)

1

-

-

... More
Pumping Machinery Centrifugal :- Supply, Installation, Testing and commissioning of star rated energy efficient horizontal spindle , Horizontal / Radial split casing.end suctions (back pull out arrangement single double multistage cuntrifugal pump suitable "for operation, in parallel of recommended make such as Maker and platt/KSB/Kirloskar/Jyoti/Beaconweir BS&BE confirming toBIS-1520-1980 with upto date ammendments suitable for lifting clearwater, for under mentioned characteristics with bronze priming funels, casing ring and shift slvves of bronze/steel, shaft of SS: 410/AIS 1431 Chrom in plated with cast iron casing coupled directly through a flexible coupling on a Common MS base plate to squirrel cage screen protected drip proof induciton motor/TEFC/CCA of standard make such as Krloskar/Bhel/Crompton/NGEF/GEC/Siemens/Jyoti/ area . the power of electirc motor/motors should be at least (+) 10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10 % and (-)15 % of the duty point head. the motor/Motors should be as per IS 325-1978 with upto date ammendments read with IS 900-1972 . the starting current of the motor shall be limited to not more than 4.5 to 5 times of full load current. (Refer data Sheet No. 4)

-

-

-

... More
Stage 1st ( From Pump House to MST) , Discharge of each working pump = 2.63 LPS, Total Head = 103.06 Mtrs, Numbers of Pumps (1 W +1 S)

1

-

-

... More
Excavation in foundation trenches etc. lift upto 1.50 mtrs. stacking the excavated soil lnot more than 3 mtrs. Clear from the edge of the excavation and then returning the stacked soil in 15 cm layers, when required into plinth sides of foundations etc. Consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth with in the lead of 20 mtrs. Pick work & jumper work 50% as per direction of Engineer-in-Charge with in all leads and lifts .

5335.99

-

-

... More
Laying jointing and testing of bevelled ended G.I. pipe (medium class )with circumfernital butt welded joints (94%) and GI flenged Joints by electric arc welding thickness shall be equal to pipe wall thickness ) and testing of G.I. pipe of following dia confirming to ISI 1239-1990 (with upto date ammendments) having wall thickness as specfied below capable of with standing required test pressure including manufacturing and fabrication of reducers/ tapers all short pipes required degree of bends etc . as per site requirement, made from parent tubes and earth work in trenches and the work of providing flanges i/c nats, bolts, gaskets will measured and paid separtely. The welding electrodes shall be as per IS: 814 of Advani oerlikon/L&T of ISI marked make . The rates also including entire carriage of material flushing cleaning and hydraulic testing of pipes D.P. test of butt welded joints complete in all respect and to the best satisfaction and direction of Engineer-in-Charge complete within all leads and lifts. (Refer data Sheet No. 6)

-

-

-

... More
125 mm dia

5760

-

-

... More
100 mm dia

1800

-

-

... More
65 mm dia

1560

-

-

... More
40 mm dia

1290

-

-

... More
Providing, Laying , jointing & testing of MSERW pipe 250mm dia ( Zinc Coated) conforming to BIS /ISO 3183-2007 of steel grade L-290 with circumfrential butt welded joints by electrical arc welding with minimum two layers /passes of weld capable to with stand required test pressure (minimum welding thickness shall be equal to pipe wall thickness in a random length of 5.5 to 6.5 meters ( having pipe diameter, wall thickness weight & frange table as specified below ) including manufacturing and fabrication of reducers/tapers, all short pieces, bends of required degrees as per site requirements made from parent tubes. The laying of pipe shall also include intermediate flanged joints spaced at an interval of 3rd pipe length or where ever required as per direction of the Engineer- in- charge duly welded in three layers ( two at outer & one on inner face) and all operations such as cutting , welding, jointing, fabrication of bends, tees i.e. lowering & laying in excavated trenches to ensure required level i/c flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer-in-Charge ( Earth work in trenches and the cost of providing flanges i/c nuts & bolts & gasket will be measured and paid for seperately). The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe and the pipes shall be factory galvanized ( Zinc coating both inside and outside ) as per relevant IS standard and the damaged portion of the pipes and specials ( if damaged during laying, jointing & operation of pipe) made from the parent tube, shall be provided anti corrosive bituminious paint over a priming coat as per AWWA specification C-203 -1978 . the welding electrod shall be as per IS 814 of Advani Oerlikon / L&T or ISI marked make . The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing. DP test of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer-in-Charge with in all leads and lifts. Note Negetive Tolerance of wall thickness should not be nore than +/-3%. (4.80 mm thick) Refer Data Sheet No. 5

3000

-

-

... More
Providing, fixing, MS flanges confirming to IS-6392-1971 (Latest with upto date ammendments) specified welding both sides of flanges according to relevant standered i/c nuts bolts and rubbur sheet washer confirming to IS 1367-1981 and carriage of material with in all leads and lifts.

-

-

-

... More
250 mm dia (T-17)

5

-

-

... More
250 mm dia (T-11)

15

-

-

... More
250 mm dia (T-5)

10

-

-

... More
125 mm dia (T-5)

42

-

-

... More
125 mm dia (T-17

10

-

-

... More
100 mm dia (T-5)

18

-

-

... More
65mm dia (T-17)

13

-

-

... More
40 mm dia (T-28)

8

-

-

... More
40 mm dia (T-17)

5

-

-

... More
Providing and fixing of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I. double flanged swing check type reflux valve having bypass arrangement of class PN 1.6 confirming to BS 1868(API-600) (latest edition) to be provided on delivery side) of size one step higher than the delivery size of pump conforming to 5312 -1984 and shall be suitable for withstanding nominal seat pressure of 21__ kg/cm².

-

-

-

... More
40 mm dia (T-28)

1

-

-

... More
65 mm dia (T-17)

1

-

-

... More
Providing and Fixing of Screwed type Cast Iron Air valve of 40mm dia (Single ball type) of leader make confirming to BIS 1452-90 with upto date ammendments as per class PN 10 to with stand the seat pressure 11.22 Kg/Cm Square in raising main or as of latest ammendments in all respect and to the eintire satisfaction of the engineer-in-charge complete within all leads and lifts.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.